• Title/Summary/Keyword: Acoustic detection

Search Result 700, Processing Time 0.027 seconds

A Study on the transducer development and multi-point signal and its directivity detection of FBG(Fiber Bragg Grating) hydrophone (FBG(Fiber Bragg Grating) 하이드로폰의 트랜스듀서 개발과 다중점 신호 검출 및 지향성에 관한 연구)

  • 김경복
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9B
    • /
    • pp.1551-1562
    • /
    • 2000
  • In the using of FBG developed in home land, we designed and manufactured three types of FBG sound transducers the first in Korea. On FBG transducers manufactured we made an demonstrated on respective frequency response peculiarties in the water and analyzed the special characters. As the experimental result on frequency response peculiarities, we made t possible underwater acoustic detection on C type to maximum 18kHz, And for the purpose of realization on multi-point signal detection on wide scope in the water, in the using of WDM(Wavelength Division Multiplexing) method and passive band-pass filter system, established arrays system and succeeded in multi-point underwater acoustic signal detection to the frequency 1.3KHz out of the two B type FBG transducers. Additionally, it would be possible directivity detection for the objects of its source as the intensity of detection signal varies with the sound source's direction and angle. From now on we prepared a new moment on the practical used study on FBG hydrophone.

  • PDF

Surface Crack Detection in Compression of Pre Heat-Treated Steel (ESW90) Using an Acoustic Emission Sensor (음향방출센서를 이용한 선조질강(ESW90)의 압축실험에서의 표면 균열 발생 검출)

  • Lee, J.E.;Lee, J.M.;Joo, H.S.;Seo, Y.H.;Kim, J.H.;Kim, S.W.
    • Transactions of Materials Processing
    • /
    • v.29 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • In the design of the metal forming processes, various types of ductile fracture criteria are used to predict crack initiation and to fabricate metallic products without any defects. However, the quantitative measurement method for determination of crack initiation is insufficient. It is very difficult to detect crack initiation in ductile metals with excellent deformability because no significant load drop is observed due to crack generation. In this study, the applicability of acoustic emission sensors, which are commonly used in facility diagnostics, to measure crack initiation during the metal forming process was analyzed. Cylindrical notch specimens were designed using the finite element method to induce a premature crack on the surface of pre heat-treated steel (ESW90) material. In addition, specimens with various notch angles and heights were prepared and compression tests were carried out. During the compression tests, acoustic emission signal on the dies and images of the surface of the notch specimen were recorded using an optical camera in real time. The experimental results revealed that the acoustic emission sensor can be used to detect crack initiation in ductile metals due to severe plastic deformation.

A Study on Non-acoustic Stealth Techniques of Submarine (잠수함의 비음향 스텔스 기법에 관한 연구)

  • Choi, Chang-Mook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1330-1334
    • /
    • 2012
  • The submarines reach their weakest point when they sail on the surface to operate snorkel and periscope. At this period, however, there lies a high possibility that the submarines are detected by non-acoustic sensors such as radars, IR signatures, and human observations. In this paper, the non-acoustic stealth was adopted on the mast and periscope of submarines so as to overcome their vulnerability of being easily detected in this given situation. First of all, the non-acoustic detection sensors were investigated and the stealth methods were analyzed. And multi-layered structures consisting of RAM layer, IR layer, and Camouflage layer were proposed on the surface of the submarine. As a results, multi-layered structure was suggested with 3~5 mm of a magnetic material such as ferrite for RAM layer, 1~2 mm of ceramic or nickel for IR layer, and sea-blue paint for Camouflage layer.

A study of noise source identification on plate excited structure borne sound by acoustic intensity method (음향인텐시티법에 의한 고체진동 가진판의 소음원 검출에 관한 연구)

  • 오재응;김상헌;홍동표;이찬홍
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.43-55
    • /
    • 1986
  • In the studies of noise reduction, it is important to know the generation mechanism of noise in order to identify the noise source. The relation between the structural vibration and the radiated sound is very complex and so this paper deals with a simplified radiation model that was originally developed as a verification tool for the acoustic intensity measurement procedure. As the first step for the identification of the noise source, this study deals with the noise evaluation by measuring sound pressure. On the next step, the acoustic radiational pattern is determined by the acoustic intensity method and this paper established that the acoustic intensity method is effective on the detection of noise. In the study, furthermore, the method could be used to predict the change in the sound radiational characteristics with the attachment of absorber and could be used in determining the attachment position.

  • PDF

The Acoustic Vibration Properties for Chicken Eggs (계란의 음향진동 특성)

  • 최완규;조한근
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.293-300
    • /
    • 2002
  • Surface crack detection is an important aspect in the quality control process of egg markets. The acoustic vibration of an egg could be used as a critical factor in evaluating the eggshell quality. The mode shape indicates the egg vibration behavior at different locations with respect to the input impulse and provides important information for the optimum sensor location to obtain the desired acoustic measurements. Theoretical analysis and experimental measurements were conducted to determine the acoustic vibration modes in eggs. The resonant fiequencies of the first and second resonance mode of intact eggs were found to be distributed between 2kHz and 7kHz range. The measured mode shapes of an egg were similar to theoretical shapes of homogeneous, elastic spheres. An elliptical deformation at the equator ring of the egg was observed. The frequency peak of this mode was dominantly present in the frequency spectrum of an intact egg impacted at its sharp position. The mode shapes related to the first resonant frequency of an egg shelved that the optimum location for the measuring sensor was the 180 degrees position. A optimum location for the egg support was found to be the 90 degrees position having the smallest vibration magnitude.

A Study On the Diagnosis Breakdown Using Fractal Characteristics and the Method of Acoustic Emission in Low Density Polyethylene (프랙탈 특성과 음향방출 계측법을 이용한 LDPE 시료에서의 트리잉 파괴진단에 관한 연구)

  • Yoon, H.J.;Park, J.J.;Shin, S.J.;Choi, J.K.;Kim, S.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1758-1760
    • /
    • 1997
  • Automatic detection system to detect acoustic emission pulse and fractal dimension were developed, to observe tree deterioration phenomena in LDPE. The purpose of our work are to use acoustic emission system and fractal dimension and to investigate the treeing phenomena in polymeric insulation under applied AC voltage 11[kV] with an artificial needle-shaped void(1.5[mm]) using the above system. We analyzed and phase angle-acoustic emission pulse amplitude-deterioration time ($\Phi$-AEA-t) pattern and phase angle-acoustic emission pulse number-deterioration time($\Phi$-AEN-t) pattern using statistical operators such as skewness, fractal dimension. In this paper show that the correlation of $\Phi$-AEA-t, $\Phi$-AEN-t, fractal dimension using regression analysis by the method of least squares can be used to predict the breakdown just before the breakdown occurs.

  • PDF

Development of a Diagnostic Algorithm with Acoustic Emission Sensors and Neural networks for Check Valves

  • Seong, Seung-Hwan;Kim, Jung-Soo;Hur, Seop;Kim, Jung-Tak;Park, Won-Man
    • Nuclear Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.540-548
    • /
    • 2004
  • Check valve failure is one of the worst problems in nuclear power plants. Recently, many researches have been based on new technology using accelerometers and ultrasonic and magnetic flux detection have been carried out. Here, we have suggested a method that uses acoustic emission sensors for detecting the failures of check valves through measuring and analyzing backward leakage flow, a system that works without disassembling the check valve. For validating the suggested acoustic emission sensor methodology, we designed a hydraulic test loop with a check valve. We have assumed in this study that check valve failure is caused by disk wear or by the insertion of a foreign object. In addition, we have developed diagnostic algorithms by using a neural network model to identify the type and size of the failure in the check valve. Our results show that the proposed diagnostic algorithm with acoustic emission sensors is a good solution for identifying check valve failure without necessitating any disassembly work.

A Study on HVDC Underwater Cable Monitoring Technology Based on Distributed Fiber Optic Acoustic Sensors (분포형 광섬유 음향 센서 기반 HVDC 해저케이블 모니터링 기술 연구)

  • Youngkuk Choi;Hyoyoung Jung;Huioon Kim;Myoung Jin Kim;Hee-Woon Kang;Young Ho Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.199-206
    • /
    • 2023
  • This study presents a novel monitoring technique for underwater high-voltage direct current (HVDC) cables based on the Distributed Acoustic Sensor (DAS). The proposed technique utilizes vibration and acoustic signals generated on HVDC cables to monitor their condition and detect events such as earthquakes, shipments, tidal currents, and construction activities. To implement the monitoring system, a DAS based on phase-sensitive optical time-domain reflectometry (Φ-OTDR) system was designed, fabricated, and validated for performance. For the HVDC cable monitoring experiments, a testbed was constructed on land, mimicking the cable burial method and protective equipment used underwater. Defined various scenarios that could cause cable damage and conducted experiments accordingly. The developed DAS system achieved a maximum measurement distance of 50 km, a distance measurement interval of 2 m, and a measurement repetition rate of 1 kHz. Extensive experiments conducted on HVDC cables and protective facilities demonstrated the practical potential of the DAS system for monitoring underwater and underground areas.