An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement (PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구)

  • Choi, Inchan;Lee, Keeman;Juddoo, Mrinal;Masri, A.R.
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.

A Study on Acoustic and Vibratory Response of a MEMS Resonant Accelerometer (공진형 MEMS 가속도계의 음향가진 반응특성 연구)

  • Lee, Sang Woo;Lee, Hyung Sub;Yu, Myeong-Jong;Kim, Do Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1330-1336
    • /
    • 2015
  • It is necessary to study on acoustic and vibratory response of a MEMS resonant accelerometer before applying to military applications. In this paper, we analyze why the resonant accelerometer reacts to an acoustic wave and a high frequency vibration. And we describe experimental results on acoustic and vibratory response of the accelerometer. The accelerometer consists of a proof mass and a dual ended tuning fork. It is a differential resonant accelerometer with arranging a pair of accelerometers. The mode shape was analyzed to find out the input mode frequency by using a FEM simulation. Some experiments regarding the acoustic noise was carried out by using a tweeter and a microphone in the anechoic room. Results showed that the accelerometer reacted to the acoustic wave and vibration which had the input mode frequency as we had expected. We showed experimentally not only that the susceptibility of the accelerometer to an acoustic wave was 70 dB but also that the effectiveness of applying an acoustic absorber and a metal case was 20 dB, respectively. Also, we could minimize the vibratory response property of the accelerometer by installing a IMU with a silicone rubber mount pad.

Effects of changes in banner size on acoustic environments in multipurpose halls for broadcasting (방송용 다목적 홀에서 배너 가변에 따른 음향 환경 변화)

  • Park, Ho-Cheul;Seo, Rosa;Seo, Chun-Ki;Jeon, Jin Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.5
    • /
    • pp.558-567
    • /
    • 2019
  • When used for broadcasting, multipurpose halls need to accommodate various types of programs such as speeches, Korean traditional music, musicals, pop music, and concerts. Therefore, multipurpose halls must meet a wide range of electric and architectural acoustic demands. However, there are few ways to alter acoustic environments for multipurpose halls, given these different demands. The current study investigates the effects of banners on acoustic environments in the presence of an acoustic shell or electric acoustic system. The results indicate that the installation of a 15% banner of wall area could vary the range of reverberation time ($T_{30}$) by 0.12 s, EDT (Early Decay Time) by 0.15 s, clarity of music ($C_{80}$) by 0.76 dB, and clarity of speech ($D_{50}$) by 6.43 % under different measurement circumstances. A computer simulation that enlarges the banner size to 40 % of the wall area varies the reverberation time from 0.11 s to 0.55 s depending on the room environment.

Real time measurement of an acoustic stream by a visualization technique, PIV (PIV(Particle Imaging Velocimetry)에 의한 음향류의 실시간 가시화 계측)

  • 도덕희
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.239-242
    • /
    • 1998
  • A new real time sound field visualization technique is introduced in this study using PIV(Particle Imaging Velocimetry) technique. Small particles of which density is small enough to follow up the air flow are used for sound visualization. When the driving frequency is in the vicinity of the resonance frequency of the simplified 2-dimensional muffler system, an acoustic streaming is shown and of which velocity distribution is obtained through PIV technique. It is experimentally proved that the present technique is able to visualize and quantify the sound field's energy flow.

  • PDF

Comparison of Resonance Characteristics in FBAR Devices by Thermal Treatments

  • Mai Linh;Song Hae-il;Yoon Giwan
    • Journal of information and communication convergence engineering
    • /
    • v.3 no.3
    • /
    • pp.137-141
    • /
    • 2005
  • The paper presents some methods to improve characteristics of film bulk acoustic resonator (FBAR) devices. The FBAR devices were fabricated on Bragg reflectors. Thermal treatments were done by sintering and/or annealing processes. The measurement showed a considerable improvement of return loss $(S_{11})$ and quality factor $(Q_{s/p}).$ These thermal treatment techniques seem very promising for enhancing FBAR resonance performance.

About the simulation error which follows in input parameters research (입력 매개변수에 따른 시뮬레이션 오차에 관한 연구)

  • Kim, Tae-Hoon;Kim, Dong-Uk;Park, Kwang-Jin;Kong, Jeong-Chul;Bae, Dong-Myung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.308-314
    • /
    • 2011
  • The research which sees, the parameters inputs and acoustic measurement result in simulation error most on a large scale concreteness of 3D models which affect number of effective surface. Therefore DATA of above the comparison which will listen, analyzed and investigated.

  • PDF

Experimental Study on Signal Sensing of a High Sensitive Fiber Optic Hydrophone (실험을 통한 소형 고감도 광섬유 하이드로폰의 감지성능 연구)

  • 김정석;윤형규;설재수
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1152-1156
    • /
    • 1999
  • In this study, a fiber optic air-backed mandrel hydrophone has been constructed and performance of acoustic signal detection has been measured. The hydrophone is based on a Mach-Zehnder interferometer with 35 m of sensing fiber. The sensitivity is measured up to -128 dB re rad/$\mu$ Pa in range from 1.4 kHz to5 kHz. A system with this design of hydrophone may be applied to detect low frequency underwater acoustic signals.

  • PDF