• Title/Summary/Keyword: Acoustic Load

Search Result 274, Processing Time 0.023 seconds

Damage Detection of Fiber-Metal Laminates Under Axial and Indentation Load (섬유-금속 적층판의 인장 및 압입 하중에서의 손상감지)

  • Yang, Yoo-Chang;Han, Kyung-Seop
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.370-375
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile and indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

A Study on the Determination of Source Location in the Failure for Brittle Material (취성재료의 파괴과정에서 A.E.에 의한 파괴원 위치 결정에 관한 연구)

  • An, Byung-Kook;Lim, Han-Uk;Lee, Sang-Eun
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.197-208
    • /
    • 1999
  • The process of localization of cracks and movement of the fracture process zone(FPZ) was studied using the acoustic-emission(AE) techniques. The rate of AE events and sources of AE activity were studied for mortar and rock specimens loaded in uniaxial compression. A series of transducers could be used to detect and AE activity. Based on the time differences between detection of the event at different transducers, source of AE activity could be detected. The rate of AE events increased sharply before peak load. The highest rate occurred just after peak load was attained. The effective crack length estimated from the modified linear-elastic fracture mechanics seemed consistent with the optical and AE measurements.

  • PDF

Damage and Failure Detection of Fiber-Metal Laminates Under Indentation Load (섬유-금속 적층판의 압입 하중에서의 손상 및 파손 검출)

  • 양유창;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.42-45
    • /
    • 2003
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Indentation test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

Evaluation of Fracture Behavior of High Tension Steel by AE Amplitude Distribution (AE 진폭분포를 이용한 고장력강의 파괴특성평가)

  • Seo, Jeong-Won;Seok, Chang-Seong;Kim, Yeong-Jin;Park, Ji-U
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.5 s.98
    • /
    • pp.175-185
    • /
    • 1999
  • Acoustic emission(AE) measurement was carried out to evaluate the fracture behavior of high tension steel. Fracture toughness $K_{AE}$ could be determined reasonably by using the load value corresponding to an abrupt change of the accumulated AE counts AE emitted from the test specimens. AE characteristics of the base metal, the weld metal and the heat-affected zone could be distinguished using a constant value b which represented the AE amplitude distribution, Consequently the structure integrity can be evaluated by variation of the constant b at the load level. In addition it was found that AE signals due to crack growth have high amplitude but low rise time and duration.

  • PDF

Failure behaviors of C/C composite tube under lateral compression loading

  • Gao, Yantao;Guan, Yuexia;Li, Ke;Liu, Min;Zhang, Can;Song, Jinliang
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1822-1827
    • /
    • 2019
  • Mechanical responses and failure behaviors of advanced C/C composite tube are very important for structural component design in nuclear reactor. In this study, an experimental investigation was conducted to study mechanical properties of C/C composite tube. Quasi-static compression loading was applied to a type of advanced composite tube to determine the response of the quasi-static load displacement curve during progressive damage. Acoustic emissions (AE) signals were captured and analyzed to characterize the crack formation and crack development. In addition, the crack propagation of the specimens was monitored by imaging technique and failure mode of the specimen was analyzed. FEM is appled to simulate the stress distribution. Results show that advanced C/C composite tube exhibits considerable energy absorption capability and stability in load-carrying capacity.

Design of Capacitive Displacement Sensor and Gap Measurement with High Precision Using Surface Acoustic Wave Device (표면 탄성파 장치를 응용한 용량 성 변위센서의 설계 및 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.5
    • /
    • pp.437-443
    • /
    • 2010
  • SAW device is widely used as band pass filters, chemical or physical sensors, and actuators. In this paper, we propose the capacitive gap measurement system with high precision using SAW device. The research process is mainly composed of theoretical and experimental part. In the theoretical part, equivalent circuit model was used to predict the SAW response by the change of load impedance. In the experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance to check the feasibility as a sensor unit. After that, experimental setup to measure and adjust the gap was made and the SAW response by the change of gap which caused the capacitance change was measured. Finally, resolution and stroke was decided compared with the signal change and basic measurement noise level.

The Bending Strength and Acoustic Emissions Properties of Sloped Finger-Jointed Rhus Verniciflua (옻나무 경사핑거접합재의 휨강도와 AE 특성)

  • 변희섭;김사익
    • Journal of the Korea Furniture Society
    • /
    • v.10 no.2
    • /
    • pp.73-78
    • /
    • 1999
  • This paper describes the relationship between the bending strength properties of sloped finger-jointed woods and the acoustic emissions(AEs) generated during the test. Rhus verniciflua pieces were cut in sloped-finger types and glued with three kinds of adhesives(polyvinyl acetate, polyvinyl-acryl acetate and oilic urethane resin). The slope ratios of finger joints were 0, 1.0, 1.5, and 2.0. The AE cumulative event count and cumulative count were measured during the bending test. The results were as follows: The lower the bending strength(load) was, the generation time of AE event count got and the higher the increasing rate of AE event count became in the sloped finger-jointed specimens bonded with polyvinyl acetate, polyvinyl-acryl acetate oilic urethane resin adhesives. Therefore, the slope from load-AE cumulative event count was very steep. The patterns of AE event count and count were very similar. The relationship between the MOR and the AE parameter from load and AE cumulatve event count in the early stage of the sloped finger-jointed specimens bonded with polyvinyl acetate, polyvinyl-acryl and oilic urethane resin adhesives was much greater than that between the MOE and the MOR. Therefore, the AE signals obtained during bending test are useful for estimating the strength of sloped finger-jointed Rhus verniciflua specimens.

  • PDF

Surface Crack Detection in Compression of Pre Heat-Treated Steel (ESW90) Using an Acoustic Emission Sensor (음향방출센서를 이용한 선조질강(ESW90)의 압축실험에서의 표면 균열 발생 검출)

  • Lee, J.E.;Lee, J.M.;Joo, H.S.;Seo, Y.H.;Kim, J.H.;Kim, S.W.
    • Transactions of Materials Processing
    • /
    • v.29 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • In the design of the metal forming processes, various types of ductile fracture criteria are used to predict crack initiation and to fabricate metallic products without any defects. However, the quantitative measurement method for determination of crack initiation is insufficient. It is very difficult to detect crack initiation in ductile metals with excellent deformability because no significant load drop is observed due to crack generation. In this study, the applicability of acoustic emission sensors, which are commonly used in facility diagnostics, to measure crack initiation during the metal forming process was analyzed. Cylindrical notch specimens were designed using the finite element method to induce a premature crack on the surface of pre heat-treated steel (ESW90) material. In addition, specimens with various notch angles and heights were prepared and compression tests were carried out. During the compression tests, acoustic emission signal on the dies and images of the surface of the notch specimen were recorded using an optical camera in real time. The experimental results revealed that the acoustic emission sensor can be used to detect crack initiation in ductile metals due to severe plastic deformation.

Acoustic emission behavior during fatigue crack propagation in 304 Stainless steel (피로균열진전에 따른 304 강의 음향방출 거동)

  • Oh, Kwang-Hwan;Jung, Chang-Kyu;Yang, Yoo-Chang;Han, Kyung-Seop
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.213-219
    • /
    • 2003
  • Acoustic emission behavior during fatigue crack growth test was investigated under various loading condition. To describe the acoustic emission activity, counts rate (d/dn) was related with SIFR (stress intensity factor range, K). Results indicated that SIFR could be divided into two parts according to its relationship with counts rate. For $K<25_{MPa\sqrt{m}}$, counts rate was increased as the SIFR increased. However, for values greater than $25_{MPa\sqrt{m}}$ , decreasing behavior was shown. This behavior of counts rate corresponding SIFR was keeping the same trend regardless of load range or crack length. Acoustic emission response to the single overload was sudden drop and slow recovery in counts rate like crack growth retardation. Under variable loading condition, counts rate of each loading block was same as that of constant amplitude loading. Overall experimental data was somewhat scattered since sensitive characteristics of acoustic emission method. However, these empirical relations indicated that counts rate was uniquely correlate with single parameter, SIFR.

  • PDF

Acoustic Emission Characteristics of Notched Aluminum Plate Repaired with a Composite Patch (복합재 패치로 보수된 노치형 알루미늄 합금 평판의 음향방출 특성)

  • Yoon, Hyun-Sung;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.53-61
    • /
    • 2011
  • Edge notched A16061-T6 aluminum was repaired with a GFRP composite patch as a function of the number of stacking, Damage progress of specimen for tension load has been monitored by acoustic emission(AE), AE energy rate, hit rate, amplitude, waveform and 1st peak frequency distribution were analyzed. Fracture processes were classified into Al cracking, Fiber breakage, Resin cracking and Delamination. Displacement of a specimen can be divided into Region I, II and ill according to acoustic emission characteristics. Region II where the patch itself was actually fractured was focused on to clarify the AE characteristics difference for the number of stacking.