• Title/Summary/Keyword: Accuracy test

Search Result 4,891, Processing Time 0.033 seconds

[Retraction] Characteristics and Optimization of Platycodon grandiflorum Root Concentrate Stick Products with Fermented Platycodon grandiflorum Root Extracts by Lactic Acid Bacteria ([논문 철회] 반응표면분석법을 이용한 젖산발효 도라지 추출물이 첨가된 도라지 농축액 제품의 최적화 연구)

  • Lee, Ka Soon;Seong, Bong Jae;Kim, Sun Ick;Jee, Moo Geun;Park, Shin Young;Mun, Jung Sik;Kil, Mi Ja;Doh, Eun Soo;Kim, Hyun Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.11
    • /
    • pp.1386-1396
    • /
    • 2017
  • The purpose of this study was to determine the optimum Platycodon grandiflorum root concentrate (PGRC, $65^{\circ}Brix$), fermented P. grandiflorum root extract by Lactobacillus plantarum (FPGRE, $2^{\circ}Brix$), and cactus Chounnyouncho extract (Cactus-E, $2^{\circ}Brix$) for preparation of PGRC stick product with FPGRE using response surface methodology (RSM). The experimental conditions were designed according to a central composite design with 20 experimental points, including three replicates for three independent variables such as amount of PGRC (8~12 g), FPGRE (0~20 g), and Cactus-E (0~20 g). The experimental data for the sensory evaluation and functional properties based on antioxidant activity and antimicrobial activity were fitted with the quadratic model, and accuracy of equations was analyzed by ANOVA. For the responses, sensory and functional properties showed significant correlation with contents of three independent variables. The results indicate that addition of PGRC contributed to increased bitterness and acridity based on the sensory test and antimicrobial activity, addition of FPGRE contributed to increased antioxidant activity and antimicrobial activity, and addition of Cactus-E contributed to increased fluidity based on the sensory test, antioxidant activity, and antimicrobial activity. Based on the results of RSM, the optimum formulation of PGRC stick product was calculated as PGRC 8.456 g, FPGRE 20.00 g, and Cactus-Ex 20.00 g with minimal bitterness and acridity, as well as optimized fluidity, antioxidant activity, and antimicrobial activity.

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

A Comparison of Discriminating Powers between 13 Microsatellite Markers and 37 Single Nucleotide Polymorphism Markers for the Use of Pork Traceability and Parentage Test of Pigs (돼지 개체식별 및 친자감별을 위한 13 microsatellite marker와 37 single nucleotide polymorphism marker 간의 효율성 비교)

  • Lee, Jae-Bong;Yoo, Chae-Kyoung;Jung, Eun-Ji;Lee, Jung-Gyu;Lim, Hyun-Tae
    • Journal of agriculture & life science
    • /
    • v.46 no.5
    • /
    • pp.73-82
    • /
    • 2012
  • Allele information from the analysis of the 13 microsatellite (MS) markers, were classified into the $F_0$, $F_1$ and $F_2$ generations, and probabilities of the same individual emergency in each generation was calculated. As a result, the 13 MS markers showed an estimate of $3.84{\times}10^{-23}$ on the premise of the randomly mated group of $F_2$, which implies that the same individuals may emerge by the use of 37 kinds of SNP markers. In this study, the experimental pigs were intercross between only 2 breeds (Korean native pig and Landrace). In addition, the success rate of paternity tests was analyzed on the whole group, by the use of the 13 MS markers and 37 SNP markers. As regards the exclusionary power of the second parent ($PE_{pu}$), MS markers and SNP markers showed 0.97897 and 0.99149, respectively. In relation to the parent exclusion power of both parent (PE), MS markers and SNP markers showed 0.99916 and 0.99949, respectively. In the case of the estimate to identify parental candidates that had the highest probability ($PNE_{pp}$), the two showed 1.00000 all. The Korean pig industry tends to mass produce hogs with limited numbers of alleles in limited parents. Such being the case, there is a need to organize a marker, for which it is imperative to find markers with high efficiency and high economic feasibility of the characteristics of DNA markers, sample size, the accuracy and expenses of genotyping cost, the manageability of data and the compatibility among analysis systems.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Development of Analytical Method for Ergot Alkaloids in Foods Using Liquid Chromatoraphy-Tandem Mass Spectrometry (LC-MS/MS를 이용한 식품 중 맥각 알칼로이드 시험법 개발)

  • Chun, So Young;Chong, Euna;Lee, Bomnae;Kwon, Jin-Wook;Park, Hye Young;Kim, Sheenhee;Gang, Giljin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.158-169
    • /
    • 2019
  • Ergot alkaloids are mycotoxin produced by fungi of the Claviceps genus, mainly by Claviceps purpurea in EU. Recently obtained informations indicates necessity for control the ergot in imported grains. Recent occurrence data of ergot alkaloids from EU countries indicate the necessities of management and control these toxins from the imported grains like rye, wheat, oat etc. The aim of this study is to optimize the liquid chromatography-tandem mass spectrometry method for determination of ergot alkaloids (ergometrine, ergosine, ergotamine, ergocornine, ergocryptine, ergocristine and their epimers (-inines) from grain and grain-based food. The test method was optimized by extracting the sample with acetonitrile containing 2 mM ammonium carbonate, purification with Mycosep cartridge, and instrumental analysis by LC-MS/MS using Syncronis C18 column. The standard calibration curves showed linearity with correlation coefficents; $R^2$ >0.99. Mean recoveries ranged from 72.0 to 111.3% at three different fortified levels (20, 50, and $100{\mu}g/kg$). The correlation coefficient expressed as precision was within the range of 1.9-12.9%. The limit or quantifications (LOQ) ranged from 0.012 to $0.058{\mu}g/kg$. The developed analytical method met the criteria of AOAC Int. and CAC validation parameters like accuracy and sensitivity. As a result, it was confirmed that the test method developed in this study is suitable for the simultaneous analysis of six species of ergot alkaloid from grains and grain products.

Work Environment Measurement Results for Research Workers and Directions for System Improvement (연구활동종사자 작업환경측정 결과 및 제도개선 방향)

  • Hwang, Je-Gyu;Byun, Hun-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.342-352
    • /
    • 2020
  • Objectives: The characteristics of research workers are different from those working in the manufacturing industry. Furthermore, the reagents used change according to the research due to the characteristics of the laboratory, and the amounts used vary. In addition, since the working time changes almost every day, it is difficult to adjust the time according to exposure standards. There are also difficulties in setting standards as in the manufacturing industry since laboratory environments and the types of experiments performed are all different. For these reasons, the measurement of the working environment of research workers is not realistically carried out within the legal framework, there is a concern that the accuracy of measurement results may be degraded, and there are difficulties in securing data. The exposure evaluation based on an eight-hour time-weighted average used for measuring the working environment to be studied in this study may not be appropriate, but it was judged and consequently applied as the most suitable method among the recognized test methods. Methods: The investigation of the use of chemical substances in the research laboratory, which is the subject of this study, was conducted in the order of carrying out work environment measurement, sample analysis, and result analysis. In the case of the use of chemical substances, after organizing the substances to be measured in the working environment, the research workers were asked to write down the status, frequency, and period of use. Work environment measurement and sample analysis were conducted by a recognized test method, and the results were compared with the exposure standards (TWA: time weighted average value) for chemical substances and physical factors. Results: For the substances subject to work environment measurement, the department of chemical engineering was the most exposed, followed by the department of chemistry. This can lead to exposure to a variety of chemicals in departmental laboratories that primarily deal with chemicals, including acetone, hydrogen peroxide, nitric acid, sodium hydroxide, and normal hexane. Hydrogen chloride was measured higher than the average level of domestic work environment measurements. This can suggest that researchers in research activities should also be managed within the work environment measurement system. As a result of a comparison between the professional science and technology service industry and the education service industry, which are the most similar business types to university research laboratories among the domestic work environment measurements provided by the Korea Safety and Health Agency, acetone, dichloromethane, hydrogen peroxide, sodium hydroxide, nitric acid, normal hexane, and hydrogen chloride are items that appear higher than the average level. This can also be expressed as a basis for supporting management within the work environment measurement system. Conclusions: In the case of research activity workers' work environment measurement and management, specific details can be presented as follows. When changing projects and research, work environment measurement is carried out, and work environment measurement targets and methods are determined by the measurement and analysis method determined by the Ministry of Employment and Labor. The measurement results and exposure standards apply exposure standards for chemical substances and physical factors by the Ministry of Employment and Labor. Implementation costs include safety management expenses and submission of improvement plans when exposure standards are exceeded. The results of this study were presented only for the measurement of the working environment among the minimum health management measures for research workers, but it is necessary to prepare a system to improve the level of safety and health.

A COVID-19 Diagnosis Model based on Various Transformations of Cough Sounds (기침 소리의 다양한 변환을 통한 코로나19 진단 모델)

  • Minkyung Kim;Gunwoo Kim;Keunho Choi
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.3
    • /
    • pp.57-78
    • /
    • 2023
  • COVID-19, which started in Wuhan, China in November 2019, spread beyond China in 2020 and spread worldwide in March 2020. It is important to prevent a highly contagious virus like COVID-19 in advance and to actively treat it when confirmed, but it is more important to identify the confirmed fact quickly and prevent its spread since it is a virus that spreads quickly. However, PCR test to check for infection is costly and time consuming, and self-kit test is also easy to access, but the cost of the kit is not easy to receive every time. Therefore, if it is possible to determine whether or not a person is positive for COVID-19 based on the sound of a cough so that anyone can use it easily, anyone can easily check whether or not they are confirmed at anytime, anywhere, and it can have great economic advantages. In this study, an experiment was conducted on a method to identify whether or not COVID-19 was confirmed based on a cough sound. Cough sound features were extracted through MFCC, Mel-Spectrogram, and spectral contrast. For the quality of cough sound, noisy data was deleted through SNR, and only the cough sound was extracted from the voice file through chunk. Since the objective is COVID-19 positive and negative classification, learning was performed through XGBoost, LightGBM, and FCNN algorithms, which are often used for classification, and the results were compared. Additionally, we conducted a comparative experiment on the performance of the model using multidimensional vectors obtained by converting cough sounds into both images and vectors. The experimental results showed that the LightGBM model utilizing features obtained by converting basic information about health status and cough sounds into multidimensional vectors through MFCC, Mel-Spectogram, Spectral contrast, and Spectrogram achieved the highest accuracy of 0.74.

Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique (영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.297-307
    • /
    • 2010
  • Recently, maintenance engineering and technology for civil and building structures have begun to draw big attention and actually the number of structures that need to be evaluate on structural safety due to deterioration and performance degradation of structures are rapidly increasing. When stiffness is decreased because of deterioration of structures and member cracks, dynamic characteristics of structures would be changed. And it is important that the damaged areas and extent of the damage are correctly evaluated by analyzing dynamic characteristics from the actual behavior of a structure. In general, typical measurement instruments used for structure monitoring are dynamic instruments. Existing dynamic instruments are not easy to obtain reliable data when the cable connecting measurement sensors and device is long, and have uneconomical for 1 to 1 connection process between each sensor and instrument. Therefore, a method without attaching sensors to measure vibration at a long range is required. The representative applicable non-contact methods to measure the vibration of structures are laser doppler effect, a method using GPS, and image processing technique. The method using laser doppler effect shows relatively high accuracy but uneconomical while the method using GPS requires expensive equipment, and has its signal's own error and limited speed of sampling rate. But the method using image signal is simple and economical, and is proper to get vibration of inaccessible structures and dynamic characteristics. Image signals of camera instead of sensors had been recently used by many researchers. But the existing method, which records a point of a target attached on a structure and then measures vibration using image processing technique, could have relatively the limited objects of measurement. Therefore, this study conducted shaking table test and field load test to verify the validity of the method that can measure multi-point displacement responses of structures using image processing technique.

Deep Learning-based Fracture Mode Determination in Composite Laminates (복합 적층판의 딥러닝 기반 파괴 모드 결정)

  • Muhammad Muzammil Azad;Atta Ur Rehman Shah;M.N. Prabhakar;Heung Soo Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.4
    • /
    • pp.225-232
    • /
    • 2024
  • This study focuses on the determination of the fracture mode in composite laminates using deep learning. With the increase in the use of laminated composites in numerous engineering applications, the insurance of their integrity and performance is of paramount importance. However, owing to the complex nature of these materials, the identification of fracture modes is often a tedious and time-consuming task that requires critical domain knowledge. Therefore, to alleviate these issues, this study aims to utilize modern artificial intelligence technology to automate the fractographic analysis of laminated composites. To accomplish this goal, scanning electron microscopy (SEM) images of fractured tensile test specimens are obtained from laminated composites to showcase various fracture modes. These SEM images are then categorized based on numerous fracture modes, including fiber breakage, fiber pull-out, mix-mode fracture, matrix brittle fracture, and matrix ductile fracture. Next, the collective data for all classes are divided into train, test, and validation datasets. Two state-of-the-art, deep learning-based pre-trained models, namely, DenseNet and GoogleNet, are trained to learn the discriminative features for each fracture mode. The DenseNet models shows training and testing accuracies of 94.01% and 75.49%, respectively, whereas those of the GoogleNet model are 84.55% and 54.48%, respectively. The trained deep learning models are then validated on unseen validation datasets. This validation demonstrates that the DenseNet model, owing to its deeper architecture, can extract high-quality features, resulting in 84.44% validation accuracy. This value is 36.84% higher than that of the GoogleNet model. Hence, these results affirm that the DenseNet model is effective in performing fractographic analyses of laminated composites by predicting fracture modes with high precision.

Accuracy of bite registration according to the buccal bite scan range of intra-oral scanner (구강 스캐너의 협측 교합 스캔 부위에 따른 교합 인기의 정확도)

  • Tae-sung Kwon;Dae-hyun Kim;Min-su Kim;Dong-jun Song;Joo-Hun Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.3
    • /
    • pp.125-134
    • /
    • 2024
  • Purpose: The aim of this study was to determine which scan range would provide the most accurate bite registration when performing a bite scan after scanning an upper and lower arch using an intraoral scanner. Materials and Methods: The occlusal contact points were recorded using articulating paper for 30 adults, and the results of various ranges of buccal bite scan were compared based on this. Buccal bite scan of 5 ranges (1st premolar to 2nd premolar, 1st premolar to 1st molar, 1st premolar to 2nd molar, 2nd premolar to 1st molar, and canines to another side canine of the maxillary teeth) was performed, and then the buccal bite scan file was used in a CAD program to confirm the occlusal area in the scan file through data editing and alignment, leaving the buccal area of the teeth. Afterwards, the degree of agreement between the occlusal contact points obtained from the articulating paper and the occlusal area obtained from the scan file was compared, and statistical analysis was performed using the homoscedastic T-test (α = 0.05). Results: The alignment success and alignment failure rates among each group were 77.23% and 40.85% in canine to another side canine, 68.23% and 28.89% in bilateral first premolar to second premolar, 63.76% and 29.97% in bilateral first premolar to first molar, 61.31% and 32.04% in bilateral first premolar to second molar, 67.55% and 27.46% in second premolar to first molar. The results of the anterior scan of both canines showed higher alignment success and failure rates compared to the scan results of all maxillary posterior teeth. In the alignment success rate, statistical significance was not found depending on the scan range of the posterior teeth, but in comparing the results of the posterior teeth and both canines, statistical significance was observed except for the scan results of the second premolar to the first molar. There was no statistical significance in the alignment failure rate depending on the scan range of the posterior teeth, and statistical significance was observed in the results of the posterior teeth and both canines. Conclusion: When taking a buccal bite scan, in the case of scanning the anterior teeth, more occlusal area appear than when scanning the posterior teeth, and in the case of scanning the posterior teeth, there is no significant difference in the bite registration depending on the scan range.