• Title/Summary/Keyword: Accuracy Rate

Search Result 3,403, Processing Time 0.026 seconds

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

Estimation of Groundwater Recharge by Considering Runoff Process and Groundwater Level Variation in Watershed (유역 유출과정과 지하수위 변동을 고려한 분포형 지하수 함양량 산정방안)

  • Chung, Il-Moon;Kim, Nam-Won;Lee, Jeong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.19-32
    • /
    • 2007
  • In Korea, there have been various methods of estimating groundwater recharge which generally can be subdivided into three types: baseflow separation method by means of groundwater recession curve, water budget analysis based on lumped conceptual model in watershed, and water table fluctuation method (WTF) by using the data from groundwater monitoring wells. However, groundwater recharge rate shows the spatial-temporal variability due to climatic condition, land use and hydrogeological heterogeneity, so these methods have various limits to deal with these characteristics. To overcome these limitations, we present a new method of estimating recharge based on water balance components from the SWAT-MODFLOW which is an integrated surface-ground water model. Groundwater levels in the interest area close to the stream have dynamics similar to stream flow, whereas levels further upslope respond to precipitation with a delay. As these behaviours are related to the physical process of recharge, it is needed to account for the time delay in aquifer recharge once the water exits the soil profile to represent these features. In SWAT, a single linear reservoir storage module with an exponential decay weighting function is used to compute the recharge from soil to aquifer on a given day. However, this module has some limitations expressing recharge variation when the delay time is too long and transient recharge trend does not match to the groundwater table time series, the multi-reservoir storage routing module which represents more realistic time delay through vadose zone is newly suggested in this study. In this module, the parameter related to the delay time should be optimized by checking the correlation between simulated recharge and observed groundwater levels. The final step of this procedure is to compare simulated groundwater table with observed one as well as to compare simulated watershed runoff with observed one. This method is applied to Mihocheon watershed in Korea for the purpose of testing the procedure of proper estimation of spatio-temporal groundwater recharge distribution. As the newly suggested method of estimating recharge has the advantages of effectiveness of watershed model as well as the accuracy of WTF method, the estimated daily recharge rate would be an advanced quantity reflecting the heterogeneity of hydrogeology, climatic condition, land use as well as physical behaviour of water in soil layers and aquifers.

The Clinical Usefulness of Cystatin C in Evaluating Renal Function in Children with Various Renal Diseases (다양한 신질환을 가진 소아에서 Cystatin C 검사의 임상적 유용성)

  • Kim, Khi-Joo;Kim, Joung-A;Shin, Jae-Il;Hwang, You-Sik;Cheung, Il-Chun;Lim, Jong-Baeck;Lee, Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.161-167
    • /
    • 2007
  • Purpose : GFR(glomerular filtration rate) is a fundamental parameter in detecting renal impairment and predicts the progression of renal disease. Because serum creatinine has several disadvantages, serum cystatin C has been recently proposed as a new endogenous marker for GFR. We compared serum cystatin C with creatinine and creatinine clearance to investigate the clinical usefulness of cystatin C. Methods : We retrospectively analyzed 46 patients(60 case numbers) who had various renal diseases and classified them into 3 groups according to creatinine clearance(Group 1 : CrCl <40 mL/min/$1.73m^2$, Group 2 : CrCl 40-60 mL/min/$1.73m^2$, Group 3 CrCl >60 mL/min/$1.73m^2$). We measured serum creatinine, cystatin C and creatinine clearance and also analyzed the correlations among them. Results : Serum cystatin C and creatinine showed a similar correlation to creatinine clearance (r=0.685, r=0.640, respectively) and showed similar diagnostic accuracy in detecting decreased GFR(AUC, cystatin C 0.829 vs. creatinine 0.826, P=0.848). Serum cystatin C showed a greater sensitivity for detecting a decreased GFR than creatinine in Group 2 and 3(Group 1 : 100% vs. 100%, Group 2 : 70% vs. 35%, Group 3 : 46% vs. 15%). Conclusions : Serum cystatin C could be a useful endogenous marker for GFR and would be superior to serum creatinine in early detection of renal impairment in pediatric patients with renal diseases.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Monitoring of Malachite Green in Freshwater Fish using LC-MS/MS (LC-MS/MS를 이용한 담수 어류 중 말라카이트 그린 분석)

  • Choi, Hee-jin;Yuk, Dong-Hyun;Park, Young-Ae;Jung, Bo-Kyeng;Hong, Mi-Sun;Yoon, Yong-Tae;Yi, Hye-Jin;Kim, Youn-Cheon;Park, Sung-Kyu;Kim, Moo-Sang;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.1
    • /
    • pp.15-20
    • /
    • 2016
  • Malachite green was measured in 200 freshwater fish collected from local markets in Seoul using HPLC-DAD and LC-MS/MS. LC-MS/MS method was validated by linearity, accuracy, precision and limits of detection and quantification according to the CODEX's recommendation and HPLC-DAD method was applied according to the Food Code. Malachite green levels above the quantification limit of the LC-MS/MS were determined 18.5% (37) but just 1 fish was shown to contain malachite green by HPLC-DAD. Of 83 domestic fish, 21 fish were detected malachite green (25.3%). Of 117 fish from China, just 16 fish were detected malachite green (13.4%). In detection rate by species carp (35.0%), Crucian carp (30.4%), cat fish (28.0%), Korean bull head (23.8%), snake head (20.0%), eel (10.5%) and loach (7.8%) were in order. Especially, fish collected at summer were shown to contain malachite green frequently; the detection rate was 54.8%.

Water Quality in a Drainage System Discharging Groundwater from Sangdae-ri Water Curtain Cultivation Area near Musimcheon Stream, Cheongju, Korea (무심천 인근 상대리 수막재배지에서 지하수 사용 후 배출되는 최종 배수로 물의 수질 특성)

  • Moon, Sang-Ho;Kim, Yongcheol;Hwang, Jeong
    • Economic and Environmental Geology
    • /
    • v.48 no.5
    • /
    • pp.409-420
    • /
    • 2015
  • The Sangdae-ri riverside around Musimcheon stream, flowing through Gadeok-myon of Cheongju City, is one of the representative strawberry fields employing water curtain cultivation (WCC) in Korea. In this area, annual groundwater use for WCC has been calculated by a few methods. On the assumption that all the water flowing through the final ditch may be mostly composed of groundwater, the discharge rate in it can be used as a good proxy for assessing the groundwater use. However, in the study area, the final ditch was set up in an unpaved state near and parallel to Musimcheon stream. Under such circumstances, the drainwater is likely to be influenced by infiltration and/or inflow of nearby stream. Hence, we examined whether or not stream water has influenced water flowing out through the final ditch in respect of ion concentrations or field parameters such as T, pH and electrical conductivity (EC) values. The period of measuring field parameters and sample collection was from February 2012 through February 2015. The drainwater in the final ditch did not show the average quality of groundwater, but similar quality of stream water in respect of pH, EC, ion contents and water type. From this, it is suggested that measuring the flow rate of the final ditch should not be directly used for assessing groundwater use in the study area. In addition, because of its sensitivity to ambient temperature, water temperature proved not to be appropriate for estimating the interaction between ditch and stream. For accuracy, additional methods will be needed to calculate mixing ratios between stream and ground water within drainage system.

An Empirical Model for Forecasting Alternaria Leaf Spot in Apple (사과 점무늬낙엽병(斑點落葉病)예찰을 위한 한 경험적 모델)

  • Kim, Choong-Hoe;Cho, Won-Dae;Kim, Seung-Chul
    • Korean journal of applied entomology
    • /
    • v.25 no.4 s.69
    • /
    • pp.221-228
    • /
    • 1986
  • An empirical model to predict initial disease occurrence and subsequent progress of Alternaria leaf spot was constructed based on the modified degree day temperature and frequency of rainfall in three years field experiments. Climatic factors were analized 10-day bases, beginning April 20 to the end of August, and were used as variables for model construction. Cumulative degree portion (CDP) that is over $10^{\circ}C$ in the daily average temperature was used as a parameter to determine the relationship between temperature and initial disease occurrence. Around one hundred and sixty of CDP was needed to initiate disease incidence. This value was considered as temperature threshhold. After reaching 160 CDP, time of initial occurrence was determined by frequency of rainfall. At least four times of rainfall were necessary to be accumulated for initial occurrence of the disease after passing temperature threshhold. Disease progress after initial incidence generally followed the pattern of frequency of rainfall accumulated in those periods. Apparent infection rate (r) in the general differential equation dx/dt=xr(1-x) for individual epidemics when x is disease proportion and t is time, was a linear function of accumulation rate of rainfall frequency (Rc) and was able to be directly estimated based on the equation r=1.06Rc-0.11($R^2=0.993$). Disease severity (x) after t time could be predicted using exponential equation $[x/(1-x)]=[x_0/(1-x)]e^{(b_0+b_1R_c)t}$ derived from the differential equation, when $x_0$ is initial disease, $b_0\;and\;b_1$ are constants. There was a significant linear relationship between disease progress and cumulative number of air-borne conidia of Alternaria mali. When the cumulative number of air-borne conidia was used as an independent variable to predict disease severity, accuracy of prediction was poor with $R^2=0.3328$.

  • PDF

Investigation of Reliability of Automatic Cracked and Bloody Egg Detector (파각란 및 혈란 자동검란기기 검출 신뢰도 검증)

  • Noh, Jae Jung;Jeon, Seung Yeob;Park, Byeong Seck;Kim, Sun Man;Kim, Heui Soo;Kim, Hyun Joo;Jo, Cheorun
    • Food Science and Preservation
    • /
    • v.20 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • This study was conducted to investigate the reliability of automatic cracked and bloody egg detector according to the age of the hens and the level of the detector. The results of this study are expected to be helpful in the implementation of the Korean egg grading system, which is expected to improve egg quality for consumers. An official egg grader randomly selected 1,000 eggs for each experiment (total 36,000 eggs), ran them through the automatic detector, and conducted labor inspection using the eggs that were classified by the detector as cracked, bloody, and normal eggs. The results showed that more cracked eggs were laid by hens aged 40-60 weeks than by hens aged 30 weeks (p<0.05). Also, when the detector level increased from four to seven (i.e., when it became less sensitive), its cracked eggs detection rate dropped, and the total rate of cracked eggs was consistent after the labor inspection of the classified eggs. The automatic detector achieved over 97 percent accuracy. The bloody eggs constituted only 0.005 percent of all the samples, and all the detector-detected eggs were bloody eggs after the labor inspection of both the bloody and normal egg lines. Therefore, it can be concluded that the automatic cracked and bloody egg detector was reliable and can be used in the egg grading system. Considering that cracked eggs should be less than 9 percent of first-grade eggs in the present egg grading system, the use of an automatic crack detector may help provide better-quality eggs to consumers by producing less than 5.5 percent cracked eggs.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.