• 제목/요약/키워드: Acceleration section

검색결과 206건 처리시간 0.024초

새만금지역에서 GIS를 이용한 광역액상화 판정 (Liquefaction Judgement on Saemangeum with GIS)

  • 송병웅;김건호;유진호;김홍택
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.49-59
    • /
    • 2010
  • Earthquake-induced liquefaction on saturated loose sand is well known in the world. Since Saemangeum Dike Project has a plan to be reclaimed with dredged sand on wide river, possibility of liquefaction should be checked. Section Dongjin5 was selected to evaluate possibility of liquefaction. Estimating method follows as 1) determination of PL value with SPT results, passing curve, and soil properties, 2) prediction for maximum earthquake acceleration, 3) calculation for FL value on depth with Korean specification for highway bridges, 4) visualization for possibility of liquefaction on all of project area with GIS 5) comparison with Japanese specification for highway bridges, Youd and Idriss method, and Andrus and Stokoe II method for verification, 6) ascertainment for the potential liquefaction with cyclic triaxial test. 7) establishing for countermeasure if needed. From the results, even though most of area covered with sand, no potential liquefaction exists except some areas. Those need to soil improvement with grout or attaching measurement on substructure.

  • PDF

대용량 동기 발전 전동기의 회생 제동 제어 알고리즘에 관한 연구 (A Study of Regeneration Breaking Control Algorithm for Wounded-field Synchronous Motor Drive)

  • 류호선;이주현;임익헌;박요집;강윤종;김장목
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.104-112
    • /
    • 2006
  • 대용량 동기 발전 전동기 운전에는 주로 사이리스터를 이용한 정지형 주파수 변환장치(SFC static Frequency Converter)시스템이 널리 사용되고 있다. 본 논문에서는 기술적인 언급이 거의 되어있지 않은 회생 제동 시스템의 개선된 제어 알고리즘을 제시하였다. 기술적 언급이 없기 때문에 실제 구동되고 있는 양수 발전소의 실측 파형을 분석하여 알고리즘을 도출하였으며 이로 인해 기존의 회생제동 제어에서 사용되었던 전압센서가 필요 없게 되어 경제적인 절감 효과를 유발하고 또한 제어요소의 간략화로 제어의 강인성을 확보하였다. 그리고 실험을 통하여 실효성 및 타당성을 검증하였다.

반사균열 저감을 위한 Saw and Seal 공법의 줄눈재 평가 및 효과에 관한 연구 (A Study on Sealant Evaluation and Effectiveness of Saw and Seal Method for Reducing Reflection Cracking)

  • 서용환;서영찬;배종오;전범준
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.73-81
    • /
    • 2012
  • PURPOSES : The purpose of this study is to select the proper sealing method and to see the performance of the saw and seal method for concrete rehabilitation based on accelerated pavement testings and lab tests. METHODS : Two accelerated pavement testings were conducted. One is to select proper sealing method of the asphalt joints and the other is to see the performance of the saw and seal method. Lab tests were conducted to select proper sealing method and a test section was constructed to see the field performance. RESULTS : The result of the first accelerated pavement testing indicated that the adhesive preformed sealants showed good performance when asphalt layer was rutted and in terms preventing from water infiltration. The second acceleration test indicated that the saw and seal method using the adhesive preformed sealant showed much better performance than the control. In the lab test bitumen, rubber and epoxy showed good performance as the adhesive. CONCLUSIONS : Saw and Seal method using the adhesive preformed sealant would markedly reduce the joint damage on the asphalt overlay.

A Design of Optimal Interval between Armatures in Long Distance Transportation PMLSM for End Cogging Force Reduction

  • Park, Eui-Jong;Jung, Sang-Yong;Kim, Yong-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.361-366
    • /
    • 2016
  • Although the permanent magnet linear synchronous motor is a motor useful for transportation systems thanks to its high speed, high acceleration and deceleration, the linear motor generally has armatures installed on the full length of the transport path. It results in the increase in material costs and manufacturing time. As a means to solve this problem a stationary discontinuous armature system is suggested. However, it involves the following two issues. The first issue is it is impossible to control the mover in the section where any armature is not installed as armatures are distributed. The second one is increasing cogging force due to the ends of the armatures. Therefore, this study aims to solve these problems by adjusting intervals between armatures to control the mover anywhere, and to design the interval between armatures optimally to minimize the end cogging force. The suitable distance was deduced. It addressed the problems and showed suitability for long distance transportation PMLSM.

한국형 틸팅열차 운행 중 운전 모드에 따른 고조파 분석 및 평가에 관한 연구 (A Study on Harmonic Analysis and Evaluation According to Operating Mode During Operation of the Tilting Train Express)

  • 강철;임재찬;허재선;김재철;이수길;한성호
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.416-421
    • /
    • 2009
  • Recently, the new Korean Tilting Train Express(TTX) which maintains a speed on the curve railway line is developed. Electric railways, including the TTX, have electrical problems that could bring about serious accidents. For such reasons, the electric railway's electrical problems, electrical harmonic and others, have been studied briskly. Thus, TTX's electrical problems also need leading studies because the new Korean TTX will operate earnestly in 2012. The results could be used hereafter diagnosis of it's components and train conditions. In the paper, electrical signals in TTX operation were measured to analyze electrical harmonic. In addition, after the electrical signals were measured to operating mode (coasting mode, acceleration mode and regenerative breaking mode) respectively in test section(Ho-nam line, Chung-buk line, Jung-ang line and Tae-baek line). The electrical harmonics considered operating modes triparted were analysed and evaluated.

Seismic responses of a metro tunnel in a ground fissure site

  • Liu, Nina;Huang, Qiang-Bing;Fan, Wen;Ma, Yu-Jie;Peng, Jian-Bing
    • Geomechanics and Engineering
    • /
    • 제15권2호
    • /
    • pp.775-781
    • /
    • 2018
  • Shake table tests were conducted on scaled tunnel model to investigate the mechanism and effect of seismic loadings on horseshoe scaled tunnel model in ground fissure site. Key technical details of the experimental test were set up, including similarity relations, boundary conditions, sensor layout, modelling methods were presented. Synthetic waves and El Centro waves were adopted as the input earthquake waves. Results measured from hanging wall and foot wall were compared and analyzed. It is found that the seismic loadings increased the subsidence of hanging wall and lead to the appearance and propagation of cracks. The values of acceleration, earth pressure and strain were greater in the hanging wall than those in the foot wall. The tunnel exhibited the greatest earth pressure on right and left arches, however, the earth pressure on the crown of arch is the second largest and the inverted arch has the least earth pressure in the same tunnel section. Therefore, the effect of the hanging wall on the seismic performance of metro tunnel in earth fissure ground should be considered in the seismic design.

플라스틱 호스 조립체의 가속수명시험 방법에 대한 연구 (A Study on Procedures of the Accelerated Life Testing for Hose Assemblies)

  • 이용범;김형의;김종기;박종호
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.79-85
    • /
    • 2004
  • There are several types of life test method for hose assemblies. The two major tests used for hose assemblies are impulse test and burst test. And magnification adjustment of impulse pressure, heating of testing oil and repetitive motions of bending and straightening of testing hose are also performed for accelerating the life. According to the manufacture process of hose and swaging process of fitting, there is a difference in the life of hose assemblies from minimum 7 times to maximum 40 times during the life test in the same functioning condition. Like this, the life test of hose which has a wide scope of life distribution gives a problem that observation should take a long time to find out the existence of the bursting from the beginning of the test to the completion of bursting of hose assemblies. Therefore, this research proposes a process of concentrating on the defective section of hose assemblies and maximizing the life acceleration by giving 'Knockdown stress' to hose assemblies just until before the hose assemblies get out of order.

  • PDF

인버터 고전압 전원공급장치를 이용한 펄스전원공급장치 연구 (Study of Pulse Generator used Inverter HV Power Supply)

  • 박성수;김상희;황정연;남상훈;이경태;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.64-67
    • /
    • 2004
  • The klystron-modulator(K&M) system of the Pohang Light Source(PLS) had been supplying high power microwaves for the acceleration of 2.5 GeV electron beams since October 2002. There are 12 sets of K&M systems to accelerate electron beams to 2.5GeV nominal beam energy. One module of the K&M system consists of an 80 MV S-band (2856 MHZ) klystron tube and the matching 200 MW modulator. In order to obtain electron beam of the consequently stability for linac, the pulse-to-pulse beam voltage regulation is less than $+/-0.5\%$. To get the reliable stability of the modulator which is less than $+/-0.5\%$, a charging section is improved in a modulator which has been operated with inverter power supply.

  • PDF

스테레오 PIV를 이용한 워터젯 흡입덕트 내부의 난류유동측정 (Stereoscopic PIV Measurement on Turbulent Flows in a Waterjet Intake Duct)

  • 권성훈;윤상열;전호환;김경천
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.612-618
    • /
    • 2004
  • Stereoscopic PIV measurements were made in the wind tunnel with the actual size waterjet model. The main wind tunnel provides the vehicle velocity while the secondary wind tunnel adjusts the jet issuing velocity. Experiments were performed at the range of jet to vehicle velocity ratio (JVR), 3.75 to 8.0 and the Reynolds number of 220,000 based on the jet velocity and the hydraulic diameter of the waterjet intake duct. Wall pressure distributions were measured for various JVRs. Three dimensional velocity fields were obtained at the inlet and outlet of the intake duct. It is found that severe acceleration is occurred at the lip region while deceleration is noticeable at the ramp side. The detailed three dimensional velocity fields can be used as the accurate velocity input for the CFD simulation. It is interesting to note that there are many different types of vortices in the instantaneous velocity field. It can be considered that those vortices are generated by the corner of rectangular section of the intake and Gortler vortices due to the curved wall. However, typical secondary flow with a pair of counter rotating vortex pair is clearly seen in the ensemble averaged velocity field.

복합재료 회전축의 진동 및 안정성 해석 (Vibration and Stability Analysis of Composite Spinning Shafts)

  • 서정석;안창기;박상윤;송오섭
    • 한국소음진동공학회논문집
    • /
    • 제25권7호
    • /
    • pp.510-517
    • /
    • 2015
  • The free vibration and stability analysis of a spinning composite shaft modelled as a thin-walled closed beam is performed for several design parameters, such as ply angle, aspect ratio, and spin speed. The governing equations of spinning shafts based on the Timoshenko beam theory are derived via Hamilton's variational principle. Coriolis acceleration and anisotropy of constituent materials are incorporated in the derivation. The equations of motion are then transformed to the standard form of an eigenvalue problem for free vibration and stability analysis. Analytical results both for uniform circular cylindrical shaft and rectangular cross-section shaft are obtained by using extended Galerkin method, and the results are compared with those from FEM ANSYS analysis for a verification.