• 제목/요약/키워드: Accelerated Deterioration Test

검색결과 118건 처리시간 0.035초

PL법 대응을 위한 전력케이블의 열 충격 및 절연파괴 특성 (The Properties of Breakdown and Test for Resistance to Cracking of Power Cable for PL Countermeasure)

  • 김영석;송길목;김선구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.349-352
    • /
    • 2007
  • It is impossible to database(DB) the patterns of cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to nicking of cable below the 22.9kV class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). First of all, set the cable in the thermal stress instrument, temperature changed from -20 degree to 120 degree. After thermal stress, we observed a surface crack of cable through microscope and carried out AC withstand voltage test.

  • PDF

PEMFC 고분자막의 화학적 내구성 평가시간 단축 (Reducing the Test Time for Chemical Durability of PEMFC Polymer Membrane)

  • 오소형;조원진;임대현;유동근;박권필
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.333-338
    • /
    • 2021
  • 대형 상용차용 PEMFC 스택 내구성은 승용차용보다 5배 이상 되어야 한다. 승용차용 PEMFC 고분자막의 화학적 가속 내구성 평가(AST)를 대형 상용차용에 그대로 적용하면 AST 시간이 2,500시간 이상이 되는 문제점이 있다. DOE(Department of Energy)의 AST 시간을 단축시키기 위해 Cathode 가스로 공기대신 산소를 사용하여 고분자막의 화학적 내구성을 평가하였다. 본 연구에서는 Nafion XL을 고분자막으로 사용해 OCV, 90 ℃, RH 30%, H2 (Anode), 공기 또는 산소조건으로 가속 내구성을 평가하였다. DOE 내구 목표 기준 중 Short 저항 감소가 제일 빨리 나타났다. 공기대신 산소를 사용함으로써 전극 열화의 영향을 적게 받으면서, 고분자막의 열화 속도를 가속화시켜 고분자막 내구성 평가시간을 절반 이하로 단축시켰다.

가속열 노화로 열화된 탄성받침 고무재료의 전단 특성(1): 천연고무 (Shear Characteristics of Elastomeric Bearing Rubber Deteriorated by Accelerated Heat Aging(1): Natural Rubber)

  • 선창호;김익현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.95-102
    • /
    • 2021
  • 유연한 고무재료를 사용하는 탄성받침은 최근 교량의 내진보강용으로 많이 적용되고 있다. 그러나 다양한 요인에 의하여 고무재료의 노화가 진행되고 이로 인해 탄성받침의 전단강성에 변화가 생기고 이는 교량의 내진성능에 영향을 미친다. 천연고무를 대상으로 노화촉진시간과 노출시간을 변수로 하여 노화촉진시험을 수행하여 전단특성의 변화를 분석하였다. 노화가 진행될수록(노화촉진온도 및 노출시간이 증가할수록) 최대전단응력과 전단변형율은 감소한다. 또한 동일한 전단변형률에서 전단강성이 크게 증가한다. 이는 고무재료가 경화됨을 의미하며 탄성받침의 내진성능이 저하되는 것을 암시한다.

플라스틱 소재의 탈변색 열화 메커니즘 분석 (A Study for Degradation Mechanism of Plastic Materials)

  • 윤형준;정원욱;변두진;최기대
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권4호
    • /
    • pp.173-181
    • /
    • 2007
  • Out door exposure to daylight and weather climate conditions can cause adverse effect on the properties of automotive plastic materials. The effects of sunlight exposure, especially ultra violet (UV) radiation, can break down the chemical bonds in a polymeric material. This degradation process is called photo-degradation and ultimately leads to color changes, cracking, chalking, the loss of physical properties and deterioration of other properties. To explore the effect of sunlight exposure on the automotive materials, this study investigated photo-oxidation degree and surface property change of molding parts by analytical methods. For the further study, accelerated weathering test methods are proposed, which can correlate with out door weathering, to predict long term performance of automotive plastic materials.

  • PDF

고무댐에 적용하기 위한 유리섬유보강 복합재료 클랩핑 플레이트의 내구 특성 (Durability Characteristics of Glass Fiber Reinforced Polymer Composite Clapping Plates for Application of Rubber Dam)

  • 이정우;박찬기;김종옥;이승기;김필식
    • 한국농공학회논문집
    • /
    • 제53권5호
    • /
    • pp.17-23
    • /
    • 2011
  • Steel clapping plate is used to connecting rubber body in rubber dam. However, once the steel clapping plate corrodes, it may cause faults, such as the same problems experienced by typical reinforcing steel. This study evaluated the applicability of glass fiber reinforced polymer composite(GFRP) clapping plate as a substitute for steel clapping plate. Absorption and load test were conducted to evaluate the decrease in durability of GFRP clapping plate exposed to deterioration environments. In the durability test results, the absorption rate of GFRP clapping plate was appeared as 0.6~1.0% in 50 day of immersion time. Also, the fracture load decreased with accelerated degradation environment exposure. Moreover, the absorption rate in GFRP clapping plate increased as degradation progressed, reducing the fracture load.

전륜 Insulator 이음 개선을 위한 강건 구조 방안 연구 (A Study On The Robust Structure For Improvement of Front Insulator Noise Improvement)

  • 이상종
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권3호
    • /
    • pp.197-206
    • /
    • 2017
  • Purpose: Clarify the cause of the noise by the front wheel strut insulator, which is located in close proximity to the driver's seat. Methods: The improvement mechanism was confirmed through failure analysis and reproduction test of the joint generation mechanism. In addition, the main factors were analyzed through principal test. Results: This paper describes the mechanism of occurrence of noise due to deterioration and hardness increase of rubber, deformation on severe road surface, foreign matter and water inflow in cold weather. Conclusion: We found that the insulator and body deformation can be minimized without increasing the thickness of the body and the insulator and reinforcing the body by dispersing the input load by applying load distribution structure instead of the local forming structure of the insulator in the insulator robust structure.

서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

포름알데히드에 의한 전통직물의 손상 특성 (Damage Characteristics of Korean Traditional Textiles by Formaldehyde)

  • 김명남;임보아;이선명
    • 보존과학회지
    • /
    • 제30권4호
    • /
    • pp.353-364
    • /
    • 2014
  • 포름알데히드는 전시 수장 공간에서 농도와 발생빈도가 높아 전통직물(천연염색)에 대한 손상 개연성이 있다. 본 연구는 견, 면, 모시, 삼베의 무염색, 천연염색(적색, 황색, 청색, 흑색) 시편을 대상으로 포름알데히드 0.5, 1, 10, 100, 500ppm 농도에서의 손상, 손상농도 500ppm에서 온습도 조건에 따른 손상과 열화상태에서의 손상을 광학적, 화학적, 물리적 측정방법으로 평가하였다. 이 결과, 포름알데히드 농도 500ppm에서 일부 직물의 색차, 변퇴색등급, 포름산이온 농도, pH가 변화하였으며, 고온 고습조건($30^{\circ}C$, 80%), 고습조건($25^{\circ}C$, 80%)에서는 색차, 변퇴색등급, 포름산이온 농도가 2배 가중되었다. 그러나, 열화직물은 열화정도, 열화 생성물질로 인해 포름알데히드에 의한 손상변화가 미미하였다. 이를 통해 포름알데히드에 의한 전통직물의 손상, 손상농도, 손상가중 조건, 열화상태에서의 손상을 확인하였으며, 포름알데히드는 적색직물의 황변, 열화직물의 황변 탈색, 포름산은 전체직물의 탈색에 영향을 미치는 것으로 나타났다.

침투성 알칼리성부여제 도포에 의한 중성화된 콘크리트의 알칼리성 회복성능에 관한 실험적 연구 (An Experimental Study on the Alkali-Recovery Performance of Impregnating Alkalization Agent for Deteriorated Concrete by Carbonation)

  • 김무한;강석표;유재강;권영진
    • 콘크리트학회논문집
    • /
    • 제13권1호
    • /
    • pp.9-15
    • /
    • 2001
  • 콘크리트 구조물의 성능저하는 여러 성능저하 요인들의 상호작용에 의해 발생한다. 특히 중성화는 시간의 경과에 따라 증가하는 대표적인 성능저하기구로 알려져 있다. 최근 들어 중성화 메카니즘에 관한 기초적인 연구와 더불어 중성화로 성능저하된 구조물의 내구성 증진을 위한 공법 및 기술개발이 활발히 진행중이다. 이에 본 논문에서는 기존에 제안되고 있는 중성화 단계에 따른 보수공법을 바탕으로 중성화된 콘크리트에 침투성 알칼리성부여제를 도포함에 따른 알칼리성 회복성상과 표면피복재의 종류에 따른 알칼리성 유지성능을 정량적으로 비교.분석하였다. 본 실험결과 알칼리성부여제를 토포함에 의해 촉진중성화에 의해 pH가 저하된 콘크리트의 알칼리성 회복성능을 확인 할 수 있었으며, 알칼리성부여제 도포후 표면피복재에 따라 콘크리트의 알칼리성 유지성능은 큰 차이를 나타내는 것으로 나타났다.

TGA를 이용한 Chlorinated Poly Vinyl Chloride(CPVC)의 활성화 에너지 평가 (Evaluation of the Activation Energy of Chlorinated Poly Vinyl Chloride (CPVC) Using Thermogravimetric Analysis)

  • 박형주
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2019
  • 열중량 분석법(TGA)을 이용하여 소방용 합성수지 배관으로 사용되는 CPVC의 활성화 에너지를 측정하였다. 열중량 분석법을 이용한 활성화 에너지는 Kissinger method와 Flynn-Wall-Ozawa method를 이용하여 계산하였다. 활성화 에너지를 계산한 결과 Kissinger method에 의해 128.07 kJ/mol, Flynn-Wall-Ozawa method에 의해 145.60 kJ/mol로 나타났다. Kissinger method와 Flynn-Wall-Ozawa method에 의해 계산된 활성화 에너지의 차이는 해석 방법이 다르다는 점을 감안했을 때 큰 차이가 없다고 판단된다. 향후 가속열화을 이용한 열적 열화평가 및 공기오븐노화시험을 통한 CPVC의 연소특성을 시험하고, 수명을 예측하고자 한다.