• Title/Summary/Keyword: Accelerated Degradation

Search Result 510, Processing Time 0.026 seconds

Analysis of Degradation Characteristics for Oil-Paper Insulation using Tan Delta Measurement (Tan Delta 측정을 이용한 유침 절연지의 열화특성 분석)

  • Kim, Jeong-Tae;Kim, Woo-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1518-1523
    • /
    • 2016
  • In this study, in order to understand the degradation characteristics of oil-paper insulation for power transformers and OF cables, tan delta was measured using cable model specimens with long-term accelerated thermal and electrical aging. In addition, to find out the degradation level due to the accelerated aging, tensile strengths of aged papers were measured. As a result, tan ${\delta}$ showed the characteristics of slight decrease at the first stage and then increase with the aging time, which could be analyzed due to the evaporation of remaining moisture and the change of aging rate with time. Also, the trend of tensile strengths with aging temperature and time was appeared to be exponentially decreased and by use of these data equivalent calculated lifetimes and accelerated aging factors were derived for each aging temperatures. After then, tan ${\delta}$ was analyzed with the equivalent operating years. For all different aging temperatures, the aged data were very well fit to the equivalent operating years and it is shown that tan ${\delta}$ was increased with the decrease of tensile strength.

Analysis of Alizarin Dye in Accelerated Degradation Conditions

  • Ahn, Cheunsoon
    • The International Journal of Costume Culture
    • /
    • v.7 no.1
    • /
    • pp.40-47
    • /
    • 2004
  • The purpose of this research was to examine the degradation rate of alizarin in accelerated degradation conditions using the GC-MS quantitative analysis. Alizarin dye solution (2.5 x 10/sup -3/ M conc.) were kept in 150℃ oven for total of 7 days and the degradation rate was examined each day. 2.5 × 10/sup -4/M conc. alizarin dye solution was mixed with H₂O₂ according to [H₂O₂]/[dye] ratio 40 and were kept under 365㎚ UV for 2 hours, analyzed after 0, 30, 60, 90, 120min using the GC-MS. Gas chromatogram showed alizarin peak at 9.96 - 10.13 min. retention time range and residual peaks in the wide range from 9.6 to 11.1 min. Oven degradation exhibited an initial decrease in the amount of alizarin, which was followed by increasing amount in 4/sup th/ day. The decrease in the alizarin was significantly shown by the 7/sup th/ day. Same pattern was also observed in the H₂O₂/UV/O₂ degradation samples and was verified ed by the UV-VIS spectra. The differences in the amount of alizarin between 1/sup st/ day and 4/sup th/ day samples, 4/sup th/ day and 7/sup th/ day samples, and Control and 7/sup th/ day samples of the oven degradation were significant at alpha .20.

  • PDF

Optimum Design of Accelerated Degradation Tests for Lognormal Distribution

  • Lee, Nak-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.1
    • /
    • pp.29-40
    • /
    • 1995
  • This paper considers the problem of optimally designing accelerated degradation tests in which the performance value of a specimen is measured only at one of three test conditions for a given exposure time. For the product having lognormally distributed performance, the optimum plan-low stress level and sample proportion allocated to each test condition - is obtained, which minimize the asymptotic variance of maximum likelihood estimator of a stated quantile at design stress. An illustrative example for the optimum plan is given.

  • PDF

A Study of Storage Life Estimation for Delay System in the Fuse of 81mm Illuminating Projectile (81미리 조명탄용 신관 KM84A1E1 지연제의 저장수명 예측 연구)

  • Chang, Il-Ho;Kim, Ji-Hoon;Lee, Woo-Chul;Back, Seung-Jun;Son, Young-Kap
    • Journal of Korean Society for Quality Management
    • /
    • v.40 no.3
    • /
    • pp.270-277
    • /
    • 2012
  • Purpose: In this paper, storage lifetime of delay system in the fuse of 81MM illuminating projectile is estimated. Methods: Accelerated degradation testings of tungsten delay system using both temperature and humidity stresses were performed, and then delay time increase of the systems were analyzed as degradation data based on distribution-based degradation processes. Results: The estimated storage lifetime of detonator is between 11.8 years and 17.6 years with each stress-life relationship. Conclusion: Comparing with field data, storage lifetime of 90% reliability is about 12 years.

A Study on the Analysis Method and Application of Accelerated Degradation Data (가속열화데이터 분석방법과 적용에 관한연구)

  • Kim, Jong-Gurl;Sung, Ki-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.407-417
    • /
    • 2011
  • 기술 발전 속도가 빨라짐에 따라 부품의 개발기간이 단축되고 있다. 더욱이 최근에는 제품들의 신뢰성이 향상되어 가속수명시험을 실시하더라도 규정된 시험 시간 동안 고장을 발견할 수 없는 경우가 많이 발생하고 있다. 또한 현업에서는 성능열화에 대한 관심이 높아지고 있으며 특히 친환경차에 대한 관심이 많아지면서 연료전지 및 납-배터리의 가속열화시험법개발에 많은 관심이 증대되고 있다. 만약 고장이 발생하지 않는다고 해서 더 가혹한 스트레스를 인가하면 전혀 다른 고장 메커니즘이 나타날 수 있기 때문에 시험의 목적을 달성하기 곤란해진다. 따라서 이런 단점을 보완하기 위해 시간에 따라 정해진 시간마다 열화 특성을 갖는 특성치를 측정하여 수명을 예측하거나 신뢰성을 평가하는 열화시험, 가속열화시험을 이용한다. 본 연구는 열화데이터 분석 방법을 정리하여 현업에 적용 가능한 분석 과정을 제안하고 향후 연료전지 및 납-배터리 가속열화시험 적용방향을 제시하고자 한다.

  • PDF

A Study of the Acclerated Degradation Phenomena on th Amorphous Silicon Thin Film Transistors with Multiple Stress (복합 스트레스에 의한 비정질 실리콘 박막 트랜지스터에서의 가속열화 현상 연구)

  • 이성규;오창호;김용상;박진석;한민구
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1121-1127
    • /
    • 1994
  • The accelerated degradation phenomena in amorphous silicon thin film transistors due to both electrical stress and visible light illumination under the elevated temperature have been investigated systematically as a function of gate bias, light intensity, and stress time. It has been found that, in case of electrical stress, the thrshold voltage shifts of a-Si:H TFT's may be attributed to the defect creation process at the early stage, while the charge trapping phenomena may be dominant when the stressing periods exceed about 2 hours. It has been also observed that the degradation in the device characteristics of a-Si:H TFT's is accelerated due to multiple stress effects, where the defect creation mechanism may be more responsible for the degradation rather than the charge trapping mechanism.

Accelerated Degradation Test of Electrolyte Membrane in PEMFC Stack (고분자 전해질 연료전지 스택에서 전해질막의 열화 가속시험)

  • Jeong, Jaejin;Lee, Sehoon;Lee, Hyeri;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.6-10
    • /
    • 2016
  • Until a recent day, degradation of PEMFC (Proton Exchange Membrane Fuel Cells) has been mainly studied in unit cell. But operation and degradation of real PEMFC going along in stack instead of unit cell. Therefore in this work, ADT (Accelerated Degradation Test) of PEMFC was done in stack and the result from stack's test was compared with that of unit cell. The polymer electrolyte membrane was degraded by repeated electrochemical and mechanical degradation method among several ADT methods. Current densities of MEA at 0.6V decreased in stack and unit cell, 28.4% and 27.8% respectively after ADT for 312 hours. Hydrogen crossover current densities of membrane increased in stack and unit cell, 16.8% and 15.2% respectively after ADT for 312 hours. The result of ADT in stack was similar that of ADT in unit cell, which showed that ADT method of unit cell was available to the stack.

Study for comparison of storage lifetimes estimation between constant and time-variant variance of degradation data (열화데이터의 등분산 가정에 따른 저장수명예측 비교 연구)

  • Back, Seungjun;Son, Youngkap;Park, Sanghyun;Lee, Munho;Kang, Insik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.154-156
    • /
    • 2017
  • Constant variance of degradation data over time has been generally assumed to estimate storage lifetime using destructive, accelerated degradation data over time. However, performance data of ammunitions deteriorate over time, and the standard deviation would tend to increase over time. This paper shows storage lifetime comparison results for constant variance and time-variant variance assumptions of degradation data over time, and proposes that time-variant variance assumption should be considered to increase accuracy in lifetime estimation.

  • PDF

Remaining useful life prediction for PMSM under radial load using particle filter

  • Lee, Younghun;Kim, Inhwan;Choi, Sikgyoung;Oh, Jaewook;Kim, Namsu
    • Smart Structures and Systems
    • /
    • v.29 no.6
    • /
    • pp.799-805
    • /
    • 2022
  • Permanent magnet synchronous motors (PMSMs) are widely used in systems requiring high control precision, efficiency, and reliability. Predicting the remaining useful life (RUL) with health monitoring of PMSMs prevents catastrophic failure and ensures reliable operation of system. In this study, a model-based method for predicting the RUL of PMSMs using phase current and vibration signals is proposed. The proposed method includes feature selection and RUL prediction based on a particle filter with a degradation model. The Paris-Erdogan model describing micro fatigue crack propagation is used as the degradation model. An experimental set-up to conduct accelerated life test, capable of monitoring various signals was designed in this study. Phase current and vibration data obtained from an accelerated life test of the PMSMs were used to verify the proposed approach. Features extracted from the data were clustered based on monotonicity and correlation clustering, respectively. The results identify the effectiveness of using the current data in predicting the RUL of PMSMs.

Accelerated Life Prediction of CPB(cold-pad-batch) Padder Roll Rubber to Chemical Degradation (CPB(Cold-Pad-Batch) 염색 패더롤 고무에서 화학적 노화로 인한 가속 수명예측)

  • Lim, Jee Young;Nam, Chang Woo;Lee, Woosung
    • Textile Coloration and Finishing
    • /
    • v.29 no.3
    • /
    • pp.155-161
    • /
    • 2017
  • In CPB(Cold-Pad-Batch) dyeing, the rubber of the padder roll is influenced by the heat, chemical and mechanical influences and thus aging of the padder roll rubber occurs. This study presents an accelerated thermal aging test of the CPB padder roll rubber with strong alkali conditions. Using Arrhenius formula of the various property values for the various aging temperatures($80^{\circ}C$, $90^{\circ}C$, $100^{\circ}C$) of the padder roll, the accelerated life predictions could be calculated. The threshold value of the property was set at different values. The hardness was set at the point where 5% degradation occurs based on the actual use conditions, and the tensile strength was set at the point where 50% degradation occurs based on the general life prediction standards. From the results of the different physical properties at differing temperatures, the Arrhenius plot could be obtained. Through the usage of the Arrhenius Equation, significant duration expectation could be predicted, and the chemical aging behavior of the CPB padder roll could be found at the arbitrary and actual temperatures.