• Title/Summary/Keyword: Absorption test

Search Result 1,424, Processing Time 0.031 seconds

Percutaneous Absorption of Ascorbic acid Dipalmitate in Various Ointment Bases (아스코르빈산 디팔미테이트의 경피흡수에 미치는 연고기제의 영향)

  • Moon, Yong-Koo;Lee, Wan-Ha
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.2
    • /
    • pp.97-101
    • /
    • 1991
  • Six different O/W cream bases containing 4% ascorbic acid dipalmitate and two different O/W cream bases containing 1% ascorbic acid were prepared. Percutanceous absorption of ascorbic acid as well as safety were determined using rabbits. The stability of the creams was also tested at room temperature. Ascorbic acid concentrations in urines varied depending on the characteristics of cream bases used. The absorption of ascorbic acid was increased and sustained with the cream bases containing branched chain esters of fatty acid instead of natural oils used currently. The excretion level of ascorbic acid in urine was high with the cream base including nonionic surfactants and a small quantity of natural oils. The creams containing nonionic surfactants showed excellent stability, while those containing anionic surfactants were not stable in terms of pH, odor and coloring test at room temperature during six months. But, the two creams containing ascorbic acid were unstable. All the cream bases tested showed good safety.

  • PDF

Evaluation of water absorption and thermal insulation properties of flooring board (플로어링보드의 흡수성 및 단열성 평가)

  • Park, Cheul-Woo;Lim, Nam-Gi;Lee, Dong-Gun;Jo, Young-Bin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.178-179
    • /
    • 2021
  • Comparing the absorption volume of test pieces immersed over time in room temperature moisture with weight, WF absorbed about 40% more than PLAIN, and PLAIN stopped absorbing after 10 minutes, but WF continued to absorb. It is thought that the woven fabric layer of the core material continued to absorb moisture. In the heat transfer test, the test piece to which only WF was applied had a temperature difference of about 2℃ compared to PLAIN, and when the insulating liquid was sprayed, there was a difference in heat transfer properties of up to 5℃. This is judged to have low heat transfer properties of the basic woven fabric, but the heat insulating liquid also further reduces heat transfer properties.

  • PDF

A study of Physical Characteristic on Machun Building Stone (마천석재의 물리적 특성에 관한 연구)

  • 양해승;김종인;최한규
    • Explosives and Blasting
    • /
    • v.22 no.2
    • /
    • pp.45-54
    • /
    • 2004
  • Samples examined in this study were acquired from Machun building stone, Dukwoo building stone in Kyungnam province The aim of this study is to examine physical features of Machun rock from specific gravity, porosity. absorption, point load test. triaxial compressive test, Brazilian test, petrology test, and chemical analysis test.

Heavy Metal Absorption Properties of Sulfonated Polyethylene Terephthalate (Sulfonated Polyethylene Terephthalate의 중금속 흡착능)

  • Kang, Young-Goo;Kim, Dong-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.92-97
    • /
    • 2003
  • The purpose of this study is heavy metal absorption of recycled PET(poly ethylene terephatalate) NWF(non woven faric). The results of test are summarized as follows; Heavy metal abworption rates in Ni ions were higher then Zn and Cu ions, whereas heavy metal absorption rates by sulfonation times were not different. The heavy metal absorption times have a higher tendency from 60 min to 120 min. There were significant negative correlations among the amount used CSA(Chloro Sulfuric Acid) and the amount of absorption Zn(r = -0.33784, p < 0.05), Cu(r = -0.61177, p < 0.01) ions, whereas correlations between heavy metal absorption rates and sulfonation times were not significant. There were significant positive correlations among the amount of absorption Zn ions and the amount of absorption Ni(r = 96475, p < 0.014), Cu(r = 0.51614, p < 0.01) ions, likewise the positive correlations between the amount of absorption N ions and the amount of absorption Cu(r = 0.54766) ions were significant(p < 0.01).

A Study on the Diagnosis for Water Absorption of Generator Stator Windings (발전기 고정자 권선의 흡습 진단)

  • Bae Y.C.;Kim H.S.;Lee D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.297-298
    • /
    • 2006
  • Water leak for the water-cooled generator stator windings affects seriously the availability and the reliability of power plants. Generally, water absorption test is conducted in the power plant during outage in order to confirm if leak part is in the bars or not. In this paper, it is described that the capacitance of winding bars is measured by using the developed water absorption instrument system and the water absorption of winding bars is evaluated by using the stochastic methods. The good results by proposed diagnosis technique can be got. It is expected that the reliability of diagnosis for water absorption is increased if the proposed methods are applied to evaluate the water absorption of stator winding bars.

  • PDF

The effect of diffusers on the measurement of sound absorption in a reverberation room (잔향실법 흡음률 측정에 미치는 확산체의 영향)

  • Han, Hee-Kab;Kim, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

Comparison of Absorption Coefficient according to Test Methods (시험방법에 따른 흡음률 비교)

  • Lee, J.W.;Gu, J.H.;Park, H.K.;Kang, Dae-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.373-378
    • /
    • 2007
  • Today, the use of the sound absorptive material is increasing to improve the room acoustics in the auditorium and music hall, etc. Usually, the sound absorption materials have been used to enhance the performance of a noise barrier and improve the room acoustics in construction site. Generally, the sound absorbtion coefficients are the most important factor reflecting the sound absorbtion performance. There are two methods to measure the sound absorption coefficient. The first one is the reverberation room method, and the second is the impedance tube method. In this study, we measure the sound absorbtion coefficients using these two methods, and then we compared the results of the sound absorbtion coefficients to look into the difference of results between reverberation room method and impedance tube method. Also we compared the results of the sound absorbtion coefficients with respect to the size of sample and the volume of reverberation room. From the experiment, we could see that the sound absorbtion coefficients are measured equally for different sample size. But the sound absorbtion coefficients are measured differently according to test methods and test conditions.

Development of Al Crash Box for High Crashworthiness Enhancement (고충돌에너지 흡수용 알루미늄 크래쉬박스 개발)

  • Yoo, J.S.;Kim, S.B.;Lee, M.Y.;Huh, H.
    • Transactions of Materials Processing
    • /
    • v.17 no.3
    • /
    • pp.182-188
    • /
    • 2008
  • Crash box is one of the most important automotive parts for crash energy absorption and is equipped at the front end of the front side member. The specific characteristics of aluminum alloys offer the possibility to design cost-effective lightweight structures with high stiffness and excellent crash energy absorption potential. This study deals with crashworthiness of aluminum crash box for an auto-body with the various types of cross section. For aluminum alloys, A17003-T7 and A17003-T5, the dynamic tensile test was carried out to apply for crash analysis at the range of strain from 0.003/sec to 200/sec. The crash analysis and the crash test were carried out for three cross sections of rectangle, hexagon and octagon. The analysis results show that the octagon cross section shape with A17003-T5 has higher crashworthiness than other cross section shapes. The effect of rib shapes in the cross section is important factor in crash analysis. Finally, new configuration of crash box with high crash energy absorption was suggested.

Reliability Evaluation of Hardness and Impact Absorption Energy of Tempered Structure Steel SCM435 (뜨임한 구조용강 SCM435의 경도 및 충격 흡수에너지에 대한 신뢰성 평가)

  • Yun, Seo-Hyun;Gu, Se-Hun;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.681-688
    • /
    • 2019
  • SM45C steel, which is widely used for mechanical structure, was carburized at 870℃ for 4 hours and tempered at 300℃ and 400℃ for 1, 3 and 6 hours. The tempered materials were evaluated for tensile test, hardness test and impact test. In particular, the hardness and the absorption energy were evaluate the reliability by the Weibull statistical analysis. 300℃-1h specimen is considered to be the best heat treatment condition in the tensile stress and the observation of fracture surface. 300℃-1h specimen showed larger shape and scale parameter than the other specimens, and Rockwell hardness variance was small and showed the best characteristics. 400℃-3h specimen showed larger shape and scale parameter than the other specimens, the dispersion of impact absorption energy is small, and showed excellent characteristics.

Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments (다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석)

  • No, Min Hyung;Park, Jea Hong;Seo, Chang Won;Sung, Jung Gon;Yun, Duk Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.399-407
    • /
    • 2022
  • Energy absorption facilities installed on roads should follow the performance standards of the real-car crash test of 'Installation and Maintenance Guidelines for Roadside Safety Facilities'. However, due to different installation conditions, such as differing structure widths on roads, some energy absorption facilities do not provide adequate performance. In order to apply varied environments on roads, an energy absorption structure was designed in this study with 150 mm height and four layers of W-shape guardrail at 200 mm intervals, and the performance was verified using LS-DYNA computer simulation. Through a real-car crash test, the performance of the facility designed by LS-DYNA was tested and was found to meet the performance of the CC2 category for crash cushions. The conclusion of the comparison demonstrates that the simulation and the real-car crash tests are both significant.