The effect of diffusers on the measurement of sound absorption in a reverberation room

잔향실법 흡음률 측정에 미치는 확산체의 영향

  • 한희갑 ((주)KCC 중앙연구소 건축음향연구실) ;
  • 김경호 ((주)KCC 중앙연구소 건축음향연구실)
  • Published : 2006.05.01

Abstract

Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

Keywords