• Title/Summary/Keyword: Absorption performance

Search Result 1,481, Processing Time 0.025 seconds

Capture of Carbon Dioxide Emitted from Coal-Fired Power Plant Using Seawater (해수를 이용한 석탄 화력발전소의 이산화탄소 포집 연구)

  • Han, Sang-Jun;Kim, Dae-Kyeong;Lee, Jae-Hee;Park, Sang-Hyeok;Wee, Jung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.340-349
    • /
    • 2013
  • The present paper investigates the availability of seawater as the absorbents to capture carbon dioxide ($CO_2$) emitted from the coal fired power plant (CFPP). For the purpose of the study, readily obtainable alkali materials in CFPP such as coal fly ash (FA), NaOH and $Ca(OH)_2$ are added to seawater to prepare the absorbents and their $CO_2$ capture performances are discussed. FA can be effectively used the additives to increase $CO_2$ capture capacity of seawater to a some extent. This is ascribed that some alkali components in FA are leached into seawater and they contribute to $CO_2$ capture in the solution. However, their leaching amount and rate are restricted by the various ions in seawater. The performance of NaOH added seawater is even lower than that of NaOH added water because $OH^-$ is substantially consumed on $Ma(OH)_2$ production prior to carbonation. $CO_2$ absorption capacity of $Ca(OH)_2$ added seawater is slightly larger than that of $Ca(OH)_2$ added water. This is because that $Ca^{2+}$ which originally present in raw seawater can participate in carbonation reaction.

Bioequivalence of MelaxTM Capsule to MobicTM Capsule (Meloxicam 7.5 mg) (모빅 캡슐(멜록시캄 7.5 mg)에 대한 멜락스 캡슐의 생물학적동등성)

  • Lee, Ye-Rie;Yeom, Seung-Bock;Ko, Youn-Jung;Ko, Jung-Kil;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.413-418
    • /
    • 2004
  • A bioequivalence of $Melax^{TM}$ capsules (Chong Kun Dang Pharm., Korea) and $Mobic^{TM}$ capsules (Boehringer Ingelheim Korea) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Single 15 mg dose of meloxicam of each medicine was administered orally to 24 healthy male volunteers. This study was performed in a $2\;{\times}\;2$ crossover design. Concentrations of meloxicam in human plasma were monitored by a high-performance liquid chromatography. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 72 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Melax^{TM}/Mobic^{TM}$ were 0.95 - 1.04 and 0.98 - 1.14, respectively. This study demonstrated a bioequivalence of $Melax^{TM}$ and $Mobic^{TM}$ with respect to the rate and extent of absorption.

The development of the Ionizer using clean room (청정환경용 정전기 제거장치 개발)

  • Jeong, Jong-Hyeog;Woo, Dong Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.603-608
    • /
    • 2018
  • Although the voltage-applied discharge method is most widely used in the semiconductor and display industries, periodic management costs are incurred because the method causes defects due to the absorption of ambient fine dust and causes emitter tip contamination due to the discharge. The emitter tip contamination problem is caused by the accumulation of fine particles in ambient air due to the corona discharge of the ionizer. Fuzzy ball generation accelerates the wear of the emitter tip and deteriorates the performance of the ionizer. Although a mechanical cleaning method using a manual brush or an automatic brush is effective for contaminant removal, it requires management of additional mechanical parts by the user. In some cases, contaminants accumulated in the emitter may be transferred to the wafer or product. In order to solve this problem, we developed an ionizer for a clean environment that can remove the pencil-type emitter tip and directly ionize the surrounding gas molecules using the tungsten wire located inside the ion tank. As a result of testing and certification by the Korea Institute of Machinery and Materials, the average concentration was $0.7572particles/ft^3$, the decay time was less than two seconds, and the ion valance was 7.6 V, which is satisfactory.

Bioequivalence of Daewoong AlendronateTM Tablet to FosamaxTM Tablet (Sodium Alendronate 70 mg) (포사맥스 정(알렌드론산나트륨 70 mg)에 대한 대웅 알렌드로네이트 정 70 mg의 생물학적동등성)

  • Lee, Ye-Rie;Jung, Sun-Koung;Yang, Seoung-Kwon;Choi, Ki-Ho;Shin, Yong-Chul;Jeon, Hyeong-Gyu;Kang, Seung-Woo;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.137-142
    • /
    • 2006
  • A bioequivalence of Daewoong $Alendronate^{TM}$ (Daewoong Pharmaceutical Co., Ltd., Korea) and $Fosamax^{TM}$ tablets (MSD Korea) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). A single 70 mg dose of sodium alendronate of each medicine was administered orally to 56 healthy male volunteers. This study was performed in a $2\;{\time}\;2$ crossover design. Concentrations of alendronate in the urine were monitored by a high-performance liquid chromatography (HPLC). $A_{et}$ (cumulative urinary excreted amount from time 0 to last sampling interval) was calculated by the accumulation of the urinary excreted alendronate. $U_{max}$ (maximum urinary excretion rate) and $T_{max}$ (time to reach $U_{max}$) were compiled from the urinary excretion rate - time data. Analysis of variance was performed using logarithmically transformed $A_{et}$ and $U_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $A_{et}$ and $U_{max}$ for Daewoong $Alendronate^{TM}/Fosamax^{TM}$ were 0.89-1.12 and 0.82-1.02, respectively. This study demonstrated the bioequivalence of Daewoong $Alendronate^{TM}$ and $Fosamax^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of NimegenTM Soft Capsule to RoAccutane® Soft Capsule (Isotretinoin 10 mg) (로아큐탄 연질캡슐(이소트레티노인 10 mg)에 대한 니메겐 연질캡슐의 생물학적동등성)

  • Yang, Seung-Kwon;La, Sook-Ie;Chang, Kyu-Young;Lee, Yun-Young;Yoon, Mi-Kyeong;Lew, Soo-Hyun;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.4
    • /
    • pp.255-261
    • /
    • 2007
  • A bioequivalence study of $Nimegen^{TM}$ soft capsule (Medica Korea Pharma. Co., Ltd.) to $RoAccutane^{(R)}$ soft capsule (Roche Korea Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Thirty healthy male Korean volunteers received each medicine at the isotretinoin dose of 60 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of isotretinoin were monitored by a high performance liquid chromatography (HPLC) for over a period of 48 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48 hr) was calculated by the linear trapezoidal rule method. $C_{MAX}$ (maximum plasma drug concentration) and $T_{MAX}$ (time to reach $C_{MAX}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{MAX}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{MAX}$ ratio for $Nimegen^{TM}/RoAccutane^{(R)}$ were $log0.860{\sim}log0.98\;and\;log0.85{\sim}log1.00$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Nimegen^{TM}\;and\;RoAccutane^{(R)}$ with respect to the rate and extent of absorption.

Bioequivalence of PirosTM Tablets to ActosTM Tablets (Pioglitazone HCl 15 mg) (액토스TM정(염산 피오글리타존 15 mg)에 대한 피로스TM정의 생물학적 동등성)

  • Kang, Jong-Min;Lee, Myung-Jae;Seo, Ji-Hyung;Choi, Sang-Jun;Lee, Jin-Sung;Ryu, Ju-Hee;Tak, Sung-Kwon;Yim, Sung-Vin;Hong, Seung-Jae;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • The purpose of the present study was to evaluate the bioequivalence of two pioglitazone HCl tablets, $Actos^{TM}$, tablets (Lilly Korea. Ltd., Korea) as a reference drug and $Piros^{TM}$, tablets (Reyon Pharm. Co., Ltd., Korea) as test drug, according to the guideline of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received one tablet containing pioglitazone HCl 15 mg in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of pioglitazone were monitored for over a period of 36 hr after administration by using a high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The area under the plasma concentration-time curve from time zero to 36 hr ($AUC_{0-36hr}$), maximum plasma drug concentration ($C_{max}$) and time to reach $C_{max}$ ($T_{max}$) were complied from the plasma concentration-time data. Analysis of variance (ANOVA) test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_{0-36hr}$ and $C_{max}$. The 90% confidence intervals of the $AUC_{0-36hr}$ ratio and the $C_{max}$ ratio for $Piros^{TM}$/$Actos^{TM}$. were log 0.8753-log 1.1286 and log 0.8669-log 1.1734, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25, recommended by KFDA. In all of these results, we concluded that the $Piros^{TM}$. tablet was bioequivalent to the $Actos^{TM}$. tablet, based on the rate and extent of absorption.

Bioequivalence of MeloxifenTM Capsule to MobicTM Capsule(Meloxicam 7.5 mg) (모빅캡슐(멜록시캄 7.5mg)에 대한 멜록시펜캡슐의 생물학적 동등성)

  • Lee, Jin-Sung;Tak, Sung-Kwon;Seo, Ji-Hyung;Kang, Jong-Min;Ryu, Ju-Hee;Yim, Sung-Vin;Hong, Seung-Jae;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.457-463
    • /
    • 2009
  • The purpose of the present study was to evaluate the bioequivalence of meloxicam capsule, $Mobic^{TM}$ capsule( Boehringer Ingelheim Ltd., Korea) as a reference drug and $Meloxifen^{TM}$ capsule (Kukje Pharma Ind. Co., Ltd., Korea) as a test drug, according to the guidelines of Korea Food and Drug Administration(KFDA). Thirty two healthy male Korean volunteers received capsule containing meloxicam 7.5 mg in a $2{\times}2$ crossover study. There was a one-week above washout period between the doses. Plasma concentrations of meloxicam were monitored for over a period of 72 hr after administration by using a high performance liquid chromatography-tandem mass spectrometer(LC-MS/MS). $AUC_t$(the area under the plasma concentration-time curve from time zero to 72 hr), $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were complied from the plasma concentration-time data. Analysis of variance(ANOVA) test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and $C_{max}$. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Meloxifen^{TM}/Mobic^{TM}$ were log 0.8605-log 0.9847 and log 0.9765-log 1.1503, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25, recommended by KFDA. In all of these results, we concluded that $Meloxifen^{TM}$ capsule was bioequivalent to $Mobic^{TM}$ capsule, based on the rate and extent of absorption.

Techno-economic Comparison of Absorption and Adsorption Processes for Carbon Monoxide (CO) Separation from Linze-Donawitz Gas (LDG) (Linze-Donawitz 가스로부터 일산화탄소(CO) 분리를 위한 흡수 및 흡착공정에 대한 기술경제성 비교)

  • Lim, Young-Il;Choi, Jinsoon;Moon, Hung-Man;Kim, Gook-Hee
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.320-331
    • /
    • 2016
  • Linze-Donawitz gas (LDG) adjunctively produced in the steel mill contains over 60% of CO. Two processes that recover high purity CO from LDG were considered: COSORB and CO-Pressure swing adsorption (PSA). This study aimed to decide which one is more economically feasible than the other by techno-economic analysis (TEA). From the technical point of view of TEA, the process flow diagram (PFD) was constructed, the mass and energy balances were calculated, and the equipment type and size were determined in order to estimate the total capital investment (TCI) and the total production cost (TPC). From the economic point of view of TEA, economic performance such as return on investment (ROI) and payback period (PBP) was evaluated, and the sensitivity analysis was carried out to identify key factors influencing ROI and PBP. It was found that CO-PSA is more economically feasible due to higher ROI and lower PBP. The CO price highly influenced ROI and PBP.

The Effects of functional foot orthotics on the balance according to Foot Shape (기능성 발보조기의 족부형태별 균형유지에 미치는 영향)

  • Chai, S.W.;Park, K.Y.;Kim, Y.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • The functional loot orthoses, when wearing shoes, are in the direct contact with bottom of foots to improve and recover the correctness of abnormal lower limb musculoskeletal imbalance and the primary role of foot and also, it can act to keep the balance and weight of body and support the weakened region, so that it is very helpful to keep body balance for the standing position. In this paper, it was researched that foot orthoses which is accommodable for the function of impact absorption including the gait stability affect on the balanced performances of body in according to the formation and the material of foot part. Taking into account the balanced performances by using the sway velocity, the estimation and comparison of the effects on the balanced performances by each formation and material for foot orthoses was evaluated into significant values(p<0.006) in only the eye-opening posture with Firm state, In this posture, the static process performed by each foot formation reveals in order of normal foot(p<0.010), flat foot(p<0.000) and hollow foot(p<0.003) and then, on the base of each formation of foot part, the result that analyze the effects of the materials of foot orthoses on the balance performance appeared showing that soft materials is more effective on the normal foot and, on the other hand, rigid materials is more effective in balancing on flat foot and hollow foot.

Toxicokinetics of rifapentine in beagle dogs (Beagle dog에 있어서 rifapentine의 독성동태연구)

  • Shin, Ho-chul;Lee, Hye-suk;Cha, Shin-woo;Han, Sang-seop;Roh, Jung-ku;Kim, Jin-suk;Lee, Won-chang
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.4
    • /
    • pp.815-822
    • /
    • 1995
  • The toxicokinetics of rifapentine was studied after an oral administration to beagle dogs. High-performance liquid chromatography(HPLC) using column-switching technique was performed to determine the serum concentrations of rifapentine. The pharmacokinetic profiles of rifapentine were analysed using one-compartment open model. Following a single oral administration of 10mg/kg, pharmacokinetic parameters were determined as follows: maximum serum concentration($C_{max}$), $28.90{\mu}g/ml$; maximum concentration time($T_{max}$), 3.7hr; elimination half-life($t_{1/2}$, 4.7hr; area under the curve(AUC), $339.0{\mu}g{\cdot}hr/ml$; volume of disiribution/bioavailability (Vd/F), 0.21 l/kg; lag time, 24min; absorption rate constant($k_a$), $0.445hr^{-1}$; elimination rate constant($k_{el}$), $0.148hr^{-1}$. After 6 month multiple oral doses of 10mg/kg/day, parameters were as follows: $C_{max}$, $34.40{\mu}g/ml$; $T_{max}$, 2.6hr; $t_{1/2}$, 6.7hr; AUC, $391.3{\mu}g{\cdot}hr/ml$; Vd/F, 0.291/kg; $k_a$, $0.976hr^{-1}$; $k_{el}$, $0.104hr^{-1}$. The consistant kinetic parameters after a single and multiple oral administration show that there was no accumulation of rifapentine after 6 month oral administration. We also simulated the concentration of rifapentine after oral multiple administration of 10 and 50mg/kg/ day, based on the parameters obtained form the single administration. The measured serum concentrations of rifapentine were well fitted to the simulated results. The simulated results show that rifapentine readily reaches to steady-state after about 3 doses and the steady-state serum concentrations($C_{ss}$) are fluctuated in between $2.2{\sim}25.2{\mu}g/ml$, and $10.6{\sim}125.2{\mu}g/ml$ at the doses of 10 and 50mg/kg/day, respectively.

  • PDF