• 제목/요약/키워드: Absolute marginal discrepancy

검색결과 15건 처리시간 0.021초

도재용 코발트-크롬 금속관의 변연적합도 비교 (Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown)

  • 전병욱;김부섭
    • 대한치과기공학회지
    • /
    • 제37권2호
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown

  • Ji, Min-Kyung;Park, Ji-Hee;Park, Sang-Won;Yun, Kwi-Dug;Oh, Gye-Jeong;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.271-277
    • /
    • 2015
  • PURPOSE. This study was to evaluate the marginal fit of two CAD-CAM anatomic contour zirconia crown systems compared to lithium disilicate glass-ceramic crowns. MATERIALS AND METHODS. Shoulder and deep chamfer margin were formed on each acrylic resin tooth model of a maxillary first premolar. Two CAD-CAM systems (Prettau$^{(R)}$Zirconia and ZENOSTAR$^{(R)}$ZR translucent) and lithium disilicate glass ceramic (IPS e.max$^{(R)}$press) crowns were made (n=16). Each crown was bonded to stone dies with resin cement (Rely X Unicem). Marginal gap and absolute marginal discrepancy of crowns were measured using a light microscope equipped with a digital camera (Leica DFC295) magnified by a factor of 100. Two-way analysis of variance (ANOVA) and post-hoc Tukey's HSD test were conducted to analyze the significance of crown marginal fit regarding the finish line configuration and the fabrication system. RESULTS. The mean marginal gap of lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) was significantly lower than that of the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) (P<.05). Both fabrication systems and finish line configurations significantly influenced the absolute marginal discrepancy (P<.05). CONCLUSION. The lithium disilicate glass ceramic crown (IPS e.max$^{(R)}$press) had significantly smaller marginal gap than the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia). In terms of absolute marginal discrepancy, the CAD-CAM anatomic contour zirconia crown system (ZENOSTAR$^{(R)}$ZR translucent) had under-extended margin, whereas the CAD-CAM anatomic contour zirconia crown system (Prettau$^{(R)}$Zirconia) and lithium disilicate glass ceramic crowns (IPS e.max$^{(R)}$press) had overextended margins.

Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study

  • Woo, Hyun-Wook;Cho, Sung-Am;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.128-131
    • /
    • 2018
  • PURPOSE. This study aimed to evaluate the marginal discrepancy of full-arch frameworks in implant-supported prostheses fabricated using pre-sintered soft alloy (PSA). MATERIALS AND METHODS. Full-arch metal frameworks were fabricated on the edentulous implant model using casting alloy (CA), fully-sintered hard alloy (FHA), and PSA (n = 4 in each group). To evaluate the misfit of the framework to the abutments, the absolute marginal discrepancy (AMD) values of the frameworks were measured in cross-sectional images that had been drawn as part of the triple-scan protocol. The AMD values were compared among the tested alloy groups using the Kruskal-Wallis test, with a post hoc Mann-Whitney U test (${\alpha}=.05$). RESULTS. The FHA and PSA groups showed lower marginal discrepancies than the CA group (P<.001). However, the FHA group did not differ significantly from the PSA group. CONCLUSION. Soft alloy milling is comparable to hard alloy milling, and it is more precise than casting in terms of the marginal fit of implant-supported, full-arch prostheses.

Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy

  • Kim, Mijoo;Kim, Jaewon;Mai, Hang-Nga;Kwon, Tae-Yub;Choi, Yong-Do;Lee, Cheong-Hee;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.280-285
    • /
    • 2019
  • PURPOSE. The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS. Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (${\alpha}=.05$). RESULTS. Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION. The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

A COMPARISON OF THE FIDELITY BETWEEN VARIOUS CORES FABRICATED WITH CAD/CAM SYSTEMS

  • Park, Sun-Hee;Lee, Kyu-Bok
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.269-279
    • /
    • 2008
  • STATEMENT OF PROBLEM: Recently, various all-ceramic crowns fabricated with CAD/CAM systems have come into wide use in dental clinic. However, there are only few domestic studies on CAD/CAM restorations. PURPOSE: Purpose of this study was to compare the fidelity (absolute marginal discrepancy and internal gap) between various cores fabricated with different CAD/CAM systems (Procera system, Lava system, Cerec inLab system) and conventional metal cast core. MATERIALS AND METHODS: 10 cores per each system were fabricated. The absolute marginal discrepancies were measured using measuring microscope and digital counter. The internal gaps were calculated using a silicone paste. The results were statistically analyzed using the one-way ANOVA test and Tukey's HSD test. RESULTS: Within the limits of this study the results were as follows. 1. The absolute marginal discrepancies were $32.5{\pm}3.7\;{\mu}m$ for metal cast core, $72.2{\pm}7.0\;{\mu}m$ for Procera core, $40.8{\pm}5.4\;{\mu}m$ for Lava core, and $55.3{\pm}8.7\;{\mu}m$ for Cerec inLab core. The internal gaps were $38.4{\pm}5.7\;{\mu}m$ for metal cast core, $71.4{\pm}5.3\;{\mu}m$ for Procera core, $45.9{\pm}7.3\;{\mu}m$ for Lava core, and $51.8{\pm}6.2\;{\mu}m$ for Cerec inLab core. 2. The fidelity of metal cast core showed the smallest gaps, followed by Lava core, Cerec inLab core, and Procera core. CONCLUSION: The fidelities of 4 core groups were all within the clinically acceptable range ($120\;{\mu}m$).

Fitting accuracy of ceramic veneered Co-Cr crowns produced by different manufacturing processes

  • von Maltzahn, Nadine Freifrau;Bernhard, Florian;Kohorst, Philipp
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권2호
    • /
    • pp.100-106
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to evaluate the fitting accuracy of single crowns made from a novel presintered Co-Cr alloy prepared with a computer-aided design and computer-aided manufacturing (CAD/CAM) technique, as compared with crowns manufactured by other digital and the conventional casting technique. Additionally, the influence of oxide layer on the fitting accuracy of specimens was tested. MATERIALS AND METHODS. A total of 40 test specimens made from Co-Cr alloy were investigated according to the fitting accuracy using a replica technique. Four different methods processing different materials were used for the manufacture of the crown copings (milling of presintered (Ceramill Sintron-group_cer_sin) or rigid alloy (Tizian NEM-group_ti_nem), selective laser melting (Ceramill NPL-group_cer_npl), and casting (Girobond NB-group_gir_nb)). The specimens were adapted to a resin model and the outer surfaces were airborne-particle abraded with aluminum oxide. After the veneering process, the fitting accuracy (absolute marginal discrepancy and internal gap) was evaluated by the replica technique in 2 steps, before removing the oxide layer from the intaglio surface of the crowns, and after removing the layer with aluminum oxide airborne-particle abrasion. Statistical analysis was performed by multifactorial analysis of variance (ANOVA) (α=.05). RESULTS. Mean absolute marginal discrepancy ranged between 20 ㎛ (group_cer_npl for specimens of Ceramill NPL) and 43 ㎛ (group_cer_sin for crowns of Ceramill Sintron) with the oxide layer and between 19 ㎛ and 28 ㎛ without the oxide layer. The internal gap varied between 33 ㎛ (group_ti_nem for test samples of Tizian NEM) and 75 ㎛ (group_gir_nb for the base material Girobond NB) with the oxide layer and between 30 ㎛ and 76 ㎛ without the oxide layer. The absolute marginal discrepancy and the internal gap were significantly influenced by the fabrication method used (P<.05). CONCLUSION. Different manufacturing techniques had a significant influence on the fitting accuracy of single crowns made from Co-Cr alloys. However, all tested crowns showed a clinically acceptable absolute marginal discrepancy and internal gap with and without oxide layer and could be recommended under clinical considerations. Especially, the new system Ceramill Sintron showed acceptable values of fitting accuracy so it can be suggested in routine clinical work.

MAD/MAM을 이용한 치과용 지르코니아 코어의 변연 적합도 (Marginal fidelity of zirconia core using MAD/MAM system)

  • 강동림;심준성;문홍석;이근우
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.1-7
    • /
    • 2010
  • 연구 목적: 본 연구에서는MAD/MAM 시스템으로 제작된 지르코니아 코어를 통상적인 방법으로 제작된 금속-도재관 코어와 CAD/CAM 시스템으로 제작된 코어와의 변연부 적합도를 비교 분석해 보고자 한다. 연구 재료 및 방법: 레진치를 전부 도재관 제작을 위한 형태로 삭제하고, 이를 복제하여 석고 모형을 제작하였다. 석고 모형에 대해 금속-도재관, CAD/CAM ($Cercon^{(R)}$), 3종의 MAD/MAM 시스템 ($Ceramill^{(R)}$, $Rainbow^{(TM)}$, $Zirkonzhan^{(R)}$)으로 각각 10개의 코어를 제작하였다. 제작된 코어를 다이에 합착하여 광학 현미경 상에서 50배율로 변연 간격을 관찰, 계측하였다. 측정된 결과는 one-way ANOVA test로 분석하고, Tukey's HSD test로 사후검정 하였다. 결과: 각 시스템에서 변연 간격의 평균과 표준 편차는 금속-도재관 코어 $51.97{\pm}23.38{\mu}m$, $Cercon^{(R)}$ $62.16{\pm}25.88{\mu}m$, $Ceramill^{(R)}$ $67.64{\pm}40.38{\mu}m$, $Rainbow^{TM}$ $125.07{\pm}42.19{\mu}m$, $Zirkonzhan^{(R)}$ $105.02{\pm}44.61{\mu}m$로 측정되었다. 결론: 금속-도재관 코어나 CAD/CAM에 비해 MAD/MAM 방식으로 제작된 코어의 변연 간격이 큰 것으로 나타났다 (P < .05). MAD/MAM 시스템 내에서도 $Ceramill^{(R)}$, $Zirkonzhan^{(R)}$, $Rainbow^{TM}$ 순으로 변연 간격이 작은 것으로 측정되었으며, 이중 $Ceramill^{(R)}$은 CAD/CAM 시스템인 $Cercon^{(R)}$과 변연 간격에 유의차가 없었다.

FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES

  • Hwang Jung-Won;Yang Jae-Ho;Lee Sun-Hyung
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.641-658
    • /
    • 2001
  • All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at $55^{\circ}$ at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at ${\times}50$ power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram($112{\mu}m$) exhibited significantly greater marginal discrepancy than In Ceram ($97{\mu}m$), and IPS Empress 2 ($94{\mu}m$) at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and accept able marginal fit values to allow clinical application.

  • PDF

디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가 (Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner)

  • 이종원;박지만
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.210-217
    • /
    • 2016
  • 목적: 본 연구의 목적은 실제 환자에서 디지털 구강스캐너로 모형 없이 제작한 보철물의 변연 및 내면 적합도를 평가하는 것이다. 대상 및 방법: 전향적 임상시험으로 시행한 본 예비 연구는 총 11개의 수복물을 대상으로 하였다. 구강스캐너(TRIOS, 3shape, Copenhagen, Denmark)로 디지털 구강인상을 채득한 후, 캐드 디자인 및 밀링 가공 과정을 통해 전부지르코니아 수복물을 제작하였다. 완성된 지르코니아관을 환자 구강 내에 시적하였고, 레플리카 술식으로 보철물-지대치 복제물을 얻었다. 이를 근원심, 협설 방향으로 잘라 변연오차, 변연간극과 축벽부, 선각부, 교합면부의 내면간극을 측정하였다. 통계처리는 Kruskal-Wallis 검정과 Mann-Whitney U 검정을 이용하여 통계적 유의성을 분석하였다(${\alpha}=.05$). 결과: 복제물을 통한 적합도 분석 결과, 근원심, 협설 절편 사이에는 통계적으로 유의한 차이가 없었다(P>.05). 변연간극에 불일치가 있었으며, 변연 오차가 변연간극 보다 컸다(P<.01). 결론: 본 연구의 한계 내에서, 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 적합도는 임상적으로 허용할만한 결과를 보였다. 그러나 지르코니아관의 변연부위가 과풍융되는 경향이 있었으므로 주의 깊은 임상 적용 및 추적 연구가 요구된다.

서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성 (Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods)

  • 조영범;정재헌;김희중
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.366-376
    • /
    • 2013
  • 구강내 스캔(Group 1), 모델 광학 스캔(Group 2)과 모델 접촉식 스캔(Group 3)방식으로 각각 zirconia 코핑을 제작하여 광학 현미경으로 적합성을 관찰하였다. 측정항목은 변연오차(absolute marginal discrepancy;AMD), 변연간극(marginal gap; MG), 측방간격(gap of axial wall; GA), 선각간격(gap of line angle; GL)와 교합간격(gap of occusal surface; GO)이었으며, 결과는 아래와 같았다. 1. Group 1, Group 2, Group 3의 평균 AMD는 각 각 $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$이고, Group1, Group 2, Group 3의 MG는 각 각 $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$였다. AMD와 MG는 각 그룹에서 통계학적으로 유의한 차이를 보여주지 않았다(Anova test, P>0.05). 2. Group 2의 GA가 Group 1과 Group 3에 비해 통계학적으로 유의하게 적은 수치를 나타내었다(Anova test, P<0.05). 3. Group 1의 GL과 GO가 다른 그룹에 비해 통계학적으로 높은 수치를 나타내었다(Mann-whitney test(P<0.05). 세 가지 스캔 방식으로 제작된 zirconia 코핑은 세라믹 보철의 가장 중요한 평가 요소인 AMD와 MG에서 서로 통계학적 차이를 보이지 않았다.