• Title/Summary/Keyword: Abnormalities Detection

Search Result 192, Processing Time 0.023 seconds

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Depression and Executive Dysfunction in Stroke (뇌졸중에서 우울증과 실행기능부전에 대한 고찰)

  • Na, Kyoung-Sae;Kim, Shin-Gyeom;Lee, Soyoung Irene;Jung, Han-Yong
    • Korean Journal of Biological Psychiatry
    • /
    • v.19 no.4
    • /
    • pp.179-186
    • /
    • 2012
  • Depression and executive dysfunction are common neuropsychiatric sequelae of stroke. Patients with stroke are more predisposed to depression and executive dysfunction compared to patients with similar degree of physical disability. Both depression and executive dysfunction are also associated with poor prognosis such as high mortality and delayed recovery after stroke. Complex neurobiological and anatomical mechanisms are associated with the development of depression and executive dysfunction after stroke. Activation of pro-inflammatory cytokines is thought to be associated with onset of depression, whereas injuries in frontal-subcortical circuit are thought to be a link between depression and executive dysfunction. Early detection of depressive symptoms and both pharmacological and non-pharmacological treatment would be helpful. In this review paper, the authors investigated 1) biological and neuroanatomical substrate for poststroke depression and executive dysfunction, 2) the relationship and common etiopathology for poststroke depression and executive dysfunction, and 3) pharmacological and non-pharmacological treatment for poststroke depression. The contents of the paper are as follows : the prevalence, clinical manifestation, and biological etiology for poststroke depression, neuroanatomical abnormalities as a common etiological factor for depression and executive dysfunction, pharmacotherapy and non-pharmacological approach.

Advanced neuroimaging techniques for evaluating pediatric epilepsy

  • Lee, Yun Jeong
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.3
    • /
    • pp.88-95
    • /
    • 2020
  • Accurate localization of the seizure onset zone is important for better seizure outcomes and preventing deficits following epilepsy surgery. Recent advances in neuroimaging techniques have increased our understanding of the underlying etiology and improved our ability to noninvasively identify the seizure onset zone. Using epilepsy-specific magnetic resonance imaging (MRI) protocols, structural MRI allows better detection of the seizure onset zone, particularly when it is interpreted by experienced neuroradiologists. Ultra-high-field imaging and postprocessing analysis with automated machine learning algorithms can detect subtle structural abnormalities in MRI-negative patients. Tractography derived from diffusion tensor imaging can delineate white matter connections associated with epilepsy or eloquent function, thus, preventing deficits after epilepsy surgery. Arterial spin-labeling perfusion MRI, simultaneous electroencephalography (EEG)-functional MRI (fMRI), and magnetoencephalography (MEG) are noinvasive imaging modalities that can be used to localize the epileptogenic foci and assist in planning epilepsy surgery with positron emission tomography, ictal single-photon emission computed tomography, and intracranial EEG monitoring. MEG and fMRI can localize and lateralize the area of the cortex that is essential for language, motor, and memory function and identify its relationship with planned surgical resection sites to reduce the risk of neurological impairments. These advanced structural and functional imaging modalities can be combined with postprocessing methods to better understand the epileptic network and obtain valuable clinical information for predicting long-term outcomes in pediatric epilepsy.

Teeth discoloration during orthodontic treatment

  • Baik, Un-Bong;Kim, Hoon;Chae, Hwa-Sung;Myung, Ji-Yun;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.334-339
    • /
    • 2017
  • Objective: Teeth discoloration is a rare orthodontic complication. The aim of this study was to report the clinical progression of discoloration during orthodontic treatment. Methods: Discolored teeth, detected during orthodontic treatment between January 2003 and December 2012 by a single dentist using similar techniques and appliances, were analyzed. Results: The total number of teeth that showed discoloration was 28. Progression of discoloration was evaluated in only 24 teeth that were observed without any treatment. During the observation period, the discoloration "improved" in 8 of the 24 teeth (33.3%) and was "maintained" in 16 (66.6%). The electric pulp test performed at the time of initial detection of discoloration showed 14.3% positivity, which improved to 21.4% at the final follow-up. None of the initial and final follow-up radiographic findings showed any abnormalities. Conclusions: When teeth discoloration is detected during orthodontic treatment, observation as an initial management is recommended over immediate treatments.

Analysis of Factors Influencing on the Early Treatment of Children With Developmental Disability (발달장애아의 조기치료에 영향을 미치는 요인 분석)

  • Park, Hye-Jeong;Kim, Sun-Hye
    • Physical Therapy Korea
    • /
    • v.6 no.1
    • /
    • pp.47-61
    • /
    • 1999
  • The purpose of this study was to investigate factors influencing on the early treatment of children with developmental disability. Data was collected from 102 mothers of children with developmental disability who were treated at 4 rehabilitation facilities in Kyunggi-Do and Kangwon-Do. The results were as follows: 1) Of a total of 102, 63 children began to receive rehabilitation therapy during the period 0~12 months (early treatment group), 38 children after 1 year of age (delayed early treatment group). 2) There were statistically significant differences between the early treatment group and delayed early treatment group for prematurity, low birth weight, the time to discover developmental abnormalities, the time of first diagnosis, and first treatment (p<0.05). 3) There were no statistically significant differences in the two groups for level of education, economic status, risk factors (except prematurity and birth weight), home care, family's cooperation and commuting time (p>0.05). Based on this study, the important factors for early treatment were early detection, early diagnosis and constant follow-up for high-risk babies.

  • PDF

The Application of 3-dimensional Surface Imaging to the Early Detection of Sacroiliitis (3차원 영상기법을 이용한 천장골염의 조기 진단)

  • Jeon, Jae-Han;Kim, Seon-Il;Lee, Du-Su
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.235-242
    • /
    • 1993
  • In the early stage of sacroilitis, it is'difficult to detect sacroiliac(Sl) abnormalities by conventional plain X-ray even though there are characteristic symptoms of ankylosing spondylitis. 3 dimensional volume rendering from the CT image was performed to make an early de tection of the structural changes of Sl joint. 2 cases who had clinical impression of ankylosing spondylitis without sacroilitis in plane X-ray and 1 case of typical ankylosing spondylitis as well as 1 case of normal control were studied. The Sl Joints were separated and each joint surface of sacrum and ilium was independently reconstructed by a special 3D manipulation program. All 2 patiant who complained of inflammatory lower back pain with no abnormal findings in the plain X-ray showed structural changes in 3 dimensionally reconstructed surface Image of the Sl joint compared to the normal control. Authors tried several parameters, such as fourler analysis of each surface and the mean and variance of Sl joint gap. We couldn't tell the statistical significance because of the limited number of cases. However, the parameters showed difference according to the progression of disease.

  • PDF

Possible Abnormalities of Chimeric Chicken Caused by the Introduction of Exogenous Genes Into Chicken Embryos via Primordial Germ Cells (PGCs)

  • Ebara, Fumio;Fujihara, Noboru
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.11
    • /
    • pp.1514-1517
    • /
    • 2000
  • In chicken, exogenous genes introduced into germinal crescent region (GCR) of the early developmental stage, where primordial germ cells (PGCs) were concentrated, were successfully transferred to the gonads via PGCs. The foreign genes were also confirmed to be successfully incorporated into F1 and F2 generations. We tried to incorporate the exogenous genes into PGCs by lipofection, then the DNA mixture was injected into GCR at stage 3-5 or 9-11 of embryonic development (Hamburger and Hamilton, 1951). The manipulated eggs were incubated, and hatched chicks were reared until sexual maturation. F1 generation was obtained from the DNA-treated chicken (DNA-chicken) mated with normal birds. Furthermore, F2 generation was also obtained from the F1 chicken mated with normal birds. The transfer of introduced foreign genes were confirmed by marker gene detection methods and PCR analysis in the hatched chicks, F1 and F2 generations. However, in our experiments, DNA-chickens showed abnormal characteristics such as low egg production rate, abnormal appearance and decreased number of spermatozoa. In the case of F1 chicken, low egg production and the deterioration of sperm capacity for insemination in male chicken were observed.

Is the Loop Electrosurgical Excision Procedure Necessary for Minor Cervical Cytological Abnormalities?

  • Aksan-Desteli, Guldeniz;Gursu, Turkan;Baykal, Cem Murat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.305-308
    • /
    • 2014
  • Background: To investigate the indications of loop electrosurgical excision procedure (LEEP) and its overtreatment rates for the see and treat and three step strategies in cases of atypical squamous cells of undetermined cytology (ASC-US) and low grade intraepithelial neoplasia (LGSIL) cytology. Materials and Methods: We retrospectively analyzed colposcopy directed biopsy (CDB) and LEEP results of 176 paients with ASC-US or LGSIL cytologies who underwent colposcopic examination. Results: Initial cytologies were ASCUS in 120 women and LGSIL in 56. According to the see and treat approach immediate LEEP was performed for38 women. Among the remaining 138 women, LEEP was performed for 32 whose CDB results revealed CIN2/3 lesions. In the see and treat group the recognition of CIN2/3 was found to be 39.4%. The overtreatment rate was 60% as compared to 25% in the three step group. In CDB group detection of CIN 2 or greater lesions increased with 3 or more biopsies. Conclusions: In patients with ASC-US/LGSIL cytologies CDB should be performed before LEEP to prevent overtreatment, with attention to all suspected areas and more than 2 biopsies taken.

A design of BIST/BICS circuits for detection of fault and defect and their locations in VLSI memories (고집적 메모리의 고장 및 결함 위치검출 가능한 BIST/BICS 회로의 설계)

  • 김대익;배성환;전병실
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.10
    • /
    • pp.2123-2135
    • /
    • 1997
  • In this paepr, we consider resistive shorts on drain-source, drain-gate, and gate-source as well as opens in MOSFETs included in typical memory cell of VLSI SRAM. Behavior of memeory is observed by analyzing voltage at storage nodes of memeory and IDDQ(quiescent power supply current) through PSPICE simulation. Using this behavioral analysis, an effective testing algorithm of complexity O(N) which can be applied to both functional testing and IDDQ testing simultaeously is proposed. Built-In Self Test(BIST) circuit which detects faults in memories and Built-In Current Sensor(BICS) which monitors the power supply bus for abnormalities in quescent current are developed and imprlemented to improve the quality and efficiency of testing. Implemented BIST and BICS circuits can detect locations of faults and defects in order to repair faulty memories.

  • PDF

The Role of Functional Imaging Techniques in the Dementia (치매 환자에서 기능 영상법의 역할)

  • Ryu, Young-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.209-217
    • /
    • 2004
  • Evaluation of dementia in patients with early symptoms of cognitive decline is clinically challenging, but the need for early, accurate diagnosis has become more crucial, since several medication for the treatment of mild to moderate Alzheimer' disease are available. Many neurodegenerative diseases produce significant brain function alteration even when structural imaging (CT or MRI) reveal no specific abnormalities. The role of PET and SPECT brain imaging in the initial assessment and differential diagnosis of dementia is beginning to evolve vapidly and growing evidence indicates that appropriate incorporation of PET into the clinical work up can improve diagnostic and prognostic accuracy with respect to Alzheimer's disease, the most common cause of dementia in the geriatric population. in the fast few years, studios comparing neuropathologic examination with PET have established reliable and consistent accuracy for diagnostic evaluations using PET - accuracies substantially exceeding those of comparable studies of diagnostic value of SPECT or of both modalities assessed side by side, or of clinical evaluations done without nuclear imaging. This review deals the role of functional brain imaging techniques in the evaluation of dementias and the role of nuclear neuroimaging in the early detection and diagnosis of Alzheimer's disease.