• 제목/요약/키워드: Abnormal voltage

검색결과 192건 처리시간 0.027초

PVDF 필름의 압전정효과에 관한 연구 (Study on the Piezoelectric Direct Effect of PVDF Film)

  • 이용국;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제13권9호
    • /
    • pp.786-790
    • /
    • 2000
  • This paper is concerned on the theoretical and experimental approaches of direct piezoelectric effect in the PVDF film. When a cantilever structure of PVDF film is bended by the external force, electric charges are concentrated on the electrode surface of the film due to the direct piezoelectric effect, and output voltage is induced from the terminals of the film. In this paper, a symbolic equation between the external force and the output voltage was introduced. Moreover, the theoretical output voltages were compared with the experimental results by falling balls, which were agreed well each other. This results can be useful in a warning system of abnormal pulse rate and breathing, and in detecting impact force and/or mechanical energy using bending of PVDF film.

  • PDF

발전용 밸브누설 실시간 감시기술 연구 (Study on the Real-Time Leak Monitoring Technique for Power Plant Valves)

  • 이상국
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

벅-타입 능동 전력 디커플링을 위한 가변 스텝을 적용한 최적 보상 이득 알고리즘 (The Optimal Compensation Gain Algorithm Using Variable Step for Buck-type Active Power Decoupling Circuits)

  • 백기호;김승권;박성민
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.121-128
    • /
    • 2018
  • This work proposes a simple control method of a buck-type active power decoupling circuit that can minimize the ripple values in the dc link voltage. The proposed method utilizes a simplified duty calculation method and an optimal compensation gain tracking algorithm with variable-step approach. Thus, the dc link voltage ripple can be effectively reduced through the proposed method along with rapid response in tracking the optimum compensation gain. Moreover, the proposed method has better dynamic responses in the load fluctuation or abnormal situation. MATLAB/Simulink simulation and hardware-in-the-loop-simulation(HILS)-based experimental results are presented to validate the effectiveness of the proposed control method.

전철용 보호계전기 시스템에 관한 연구 (A Study on Railway Electric Traction Protection System)

  • 이희용;김왕곤;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1390-1395
    • /
    • 2004
  • Recently, the load increasement and new regenerative systems of electrified railway system make it a difficult to distinguish between the load current and fault current. The failure of traction system perhaps causes over-current to flow. The high current can collapse other railway systems. If failures of the traction system takes place, the failures are detected and protected lest it should provoke high current flow. The over current from such a traction system failure permit to charge high tension voltage and produces high temperature arc, voltage instability, current cutting, and break down railway systems. The traction system failures detect and the system has to immediately cut off from over-current flow. To isolate the failure, the system can distinguish failure current from current flows. It forces us to adapt such as a new intelligent protection system. The protective system in traction system play a role of detecting and isolating failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

점화플러그의 점화특성에 관한 실험적 연구 (An Experimental Study on the Ignition Characteristic of Ignition Plug)

  • 심상철;조태영;정병국;송규근;정재연;김형곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2088-2093
    • /
    • 2004
  • Harmful elements from the exhaust gases are caused by incomplete combustion of mixture inside the engine cylinder and this abnormal combustion like misfire or partial burning is the direct cause of the air pollution and engine performance degradation. In this study, I obtain the shapes of spark, voltage and current generated when changing the experimental parameters such as grounded electrode shapes, electrode gap and the material of center electrodes. After that, I produce ignition energy by using the voltage and current and classify ignition energy into capacitive discharge energy and inductive discharge energy.

  • PDF

A Method for Indentifying Broken Rotor Bar and Stator Winding Fault in a Low-voltage Squirrel-cage Induction Motor Using Radial Flux Sensor

  • Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.666-670
    • /
    • 2011
  • In this paper, a method for detecting broken rotor bar and stator winding fault in a low voltage squirrel-case induction motor using an air-gap flux variation analysis is proposed to develop a simple and low cost diagnosis technique. To measure the leakage flux in radial direction, a radial flux sensor is designed as a search coil and installed between stator slots. The proposed method is able to identify two kinds of motor faults by calculating load condition of motors and monitoring abnormal signals those are related with motor faults. Experimental results obtained on 7.5kW three-phase squirrel-cage induction motors are discussed to verify the performance of the proposed method.

배전선로에서의 조가선 차폐 효과 연구 (A Study on a Shielding Effect of the Messenger Wires in Distribution Lines)

  • 김인수;한웅;여상민;김철환;원봉주;임용훈
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발- (Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings -)

  • 정민화;조용상;윤동진;권오양
    • 비파괴검사학회지
    • /
    • 제16권3호
    • /
    • pp.155-161
    • /
    • 1996
  • 회전 기계의 저어널 베어링 상태를 음향 방출(AE) 기술을 활용하여 감시하기 위한 진단 시스템을 개발하였다. AE 기술은 베어링 시스템에 있어서 비정상 상태를 탐지하기 위하여 이용된다 모의 저어널 베어링시스템을 이용한 실험과 실제 발전 설비에 대한 적용 시험의 결과로부터 AE 신호 파라메타 중에서 rms voltage가 가장 유효한 것으로 판명되었으며, 이러한 연구 결과를 토대로 하여 진단 시스템의 알고리즘과 판단 기준들이 설정되었다. 베어링 진단 시스템은 AE 센서 및 전치앰프로 구성된 신호 감지부, AE rms voltage를 측정하기 위한 rms-to-DC 변환 회로부로 구성된 신호 처리부, A/D 변환기를 이용하여 rms voltage 신호를 PC에 연결해 주는 인터페이스부, 베어링 상태 보기와 진단 프로그램을 포함하는 그래픽 디스플레이 및 소프트웨어부의 4부분으로 구성된다.

  • PDF

GMAW 품질분석을 위한 신호처리 방법에 관한 연구 (A study on the welding current and voltage signal processing method for the quality evaluation of robotic GMAW)

  • 홍우헌;류정탁
    • 한국산업정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.25-31
    • /
    • 2014
  • GMAW(Gas metal arc welding) 방법은 높은 용착률과 낮은 비용으로 인해 제조 산업분야에서 폭넓게 사용되고 있다. 이 용접방법은 제조 산업분야에서 높은 생산력을 유지하는데 바탕이 되고, 자동화 설비 또는 로봇을 이용한 용접에 적합하다. 용접전압과 전류는 용접비드에 많은 영향을 미친다. 그럼에도 불구하고 용접 전압과 전류는 용접 조건과 사용자 환경에 따라 그 변화가 심하고 예측이 불가능하다. 이 값들을 직접 용접 상태 검출에 사용할 수 없기 때문에 적절한 데이터 분석 기법이 사용되어야 한다. 본 논문에서는 용접 중에 측정된 전압과 전류 데이터에 대하여 이동평균필터를 적용하였다. 그 결과 정상용접 상태의 전압 및 전류의 신호특성과 비정상용접 상태의 전압 및 전류 신호의 특성을 구분할 수 있었으며 이를 통해 용접 상태 검출이 가능하게 되었다.

교류 발전기용 하이브리드 자동 전압 조정기 개발 (Development of Hybrid AVR for Alternator)

  • 양근호
    • 융합신호처리학회논문지
    • /
    • 제16권4호
    • /
    • pp.182-188
    • /
    • 2015
  • 아날로그 AVR은 부하의 변동에 따라 전압이 비정상상태가 되었다가 다시 정상상태로 돌아가는데 걸리는 시간이 빠른 장점이 있다. 하지만 아날로그 AVR은 부하 변동에 따른 전압변동이 크다는 문제가 있다. 디지털 AVR의 전압변동률은 매우 안정적이지만, 불안정상태에서 안정한 정상상태로 회복하는데 걸리는 시간인 시정수가 아날로그 AVR에 비해 매우 길다. 따라서 부하변동이 매우 큰 상황에서 불안정한 출력성능을 나타낸다. 본 논문에서는 두 AVR의 혼합된 형태를 가지며 빠른 시정수와 안정된 전압조정 능력을 갖는 하이브리드 AVR을 제안한다. 개발된 하이브리드 AVR의 경우 부하에 따른 전압 변동이 1[%] 이내로 안정적이며, 전압 안정률도 개선되었다. 또한 아날로그 AVR 수준의 빠른 시정수를 나타내었다. 따라서 본 연구를 통해서 개발된 하이브리드 AVR은 산업현장에서 다양한 용도의 전원공급장치로 활용될 수 있다.