• Title/Summary/Keyword: Abnormal voltage

Search Result 193, Processing Time 0.024 seconds

Study on the Piezoelectric Direct Effect of PVDF Film (PVDF 필름의 압전정효과에 관한 연구)

  • 이용국;한득영
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.9
    • /
    • pp.786-790
    • /
    • 2000
  • This paper is concerned on the theoretical and experimental approaches of direct piezoelectric effect in the PVDF film. When a cantilever structure of PVDF film is bended by the external force, electric charges are concentrated on the electrode surface of the film due to the direct piezoelectric effect, and output voltage is induced from the terminals of the film. In this paper, a symbolic equation between the external force and the output voltage was introduced. Moreover, the theoretical output voltages were compared with the experimental results by falling balls, which were agreed well each other. This results can be useful in a warning system of abnormal pulse rate and breathing, and in detecting impact force and/or mechanical energy using bending of PVDF film.

  • PDF

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

The Optimal Compensation Gain Algorithm Using Variable Step for Buck-type Active Power Decoupling Circuits (벅-타입 능동 전력 디커플링을 위한 가변 스텝을 적용한 최적 보상 이득 알고리즘)

  • Baek, Ki-Ho;Kim, Seung-Gwon;Park, Sung-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.121-128
    • /
    • 2018
  • This work proposes a simple control method of a buck-type active power decoupling circuit that can minimize the ripple values in the dc link voltage. The proposed method utilizes a simplified duty calculation method and an optimal compensation gain tracking algorithm with variable-step approach. Thus, the dc link voltage ripple can be effectively reduced through the proposed method along with rapid response in tracking the optimum compensation gain. Moreover, the proposed method has better dynamic responses in the load fluctuation or abnormal situation. MATLAB/Simulink simulation and hardware-in-the-loop-simulation(HILS)-based experimental results are presented to validate the effectiveness of the proposed control method.

A Study on Railway Electric Traction Protection System (전철용 보호계전기 시스템에 관한 연구)

  • Lee, Hee-Yong;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1390-1395
    • /
    • 2004
  • Recently, the load increasement and new regenerative systems of electrified railway system make it a difficult to distinguish between the load current and fault current. The failure of traction system perhaps causes over-current to flow. The high current can collapse other railway systems. If failures of the traction system takes place, the failures are detected and protected lest it should provoke high current flow. The over current from such a traction system failure permit to charge high tension voltage and produces high temperature arc, voltage instability, current cutting, and break down railway systems. The traction system failures detect and the system has to immediately cut off from over-current flow. To isolate the failure, the system can distinguish failure current from current flows. It forces us to adapt such as a new intelligent protection system. The protective system in traction system play a role of detecting and isolating failure points. In this paper, we proposed intelligent algorithm for discriminating normal and abnormal situation instead of the system being operated abnormally.

  • PDF

An Experimental Study on the Ignition Characteristic of Ignition Plug (점화플러그의 점화특성에 관한 실험적 연구)

  • Sim, Sang-Cherl;Cho, Tae-Young;Jung, Byoung-Koog;Song, Kyu-Keun;Jung, Jea-Youn;Kim, Hyung-Gon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2088-2093
    • /
    • 2004
  • Harmful elements from the exhaust gases are caused by incomplete combustion of mixture inside the engine cylinder and this abnormal combustion like misfire or partial burning is the direct cause of the air pollution and engine performance degradation. In this study, I obtain the shapes of spark, voltage and current generated when changing the experimental parameters such as grounded electrode shapes, electrode gap and the material of center electrodes. After that, I produce ignition energy by using the voltage and current and classify ignition energy into capacitive discharge energy and inductive discharge energy.

  • PDF

A Method for Indentifying Broken Rotor Bar and Stator Winding Fault in a Low-voltage Squirrel-cage Induction Motor Using Radial Flux Sensor

  • Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.666-670
    • /
    • 2011
  • In this paper, a method for detecting broken rotor bar and stator winding fault in a low voltage squirrel-case induction motor using an air-gap flux variation analysis is proposed to develop a simple and low cost diagnosis technique. To measure the leakage flux in radial direction, a radial flux sensor is designed as a search coil and installed between stator slots. The proposed method is able to identify two kinds of motor faults by calculating load condition of motors and monitoring abnormal signals those are related with motor faults. Experimental results obtained on 7.5kW three-phase squirrel-cage induction motors are discussed to verify the performance of the proposed method.

A Study on a Shielding Effect of the Messenger Wires in Distribution Lines (배전선로에서의 조가선 차폐 효과 연구)

  • Kim, In-Soo;Han, Woong;Yeo, Sang-Min;Kim, Chul-Hwan;Weon, Bong-Ju;Lim, Yong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.431-436
    • /
    • 2009
  • As the telecommunication lines bring into widespread use, one of the most important aspects related to power distribution systems is effectively to evaluate the effect on the telecommunication lines from power lines. One of the efficient methods to evaluate the effect is to measure the induced voltage of a telecommunication line as a result of a ground-loop. If the power lines cause high induced voltage, the ground reference in the telecommunication lines is no longer a stable potential, so signals may ride on the noise. A ground loop is common wiring conditions where a ground current may take more than one path to return to the grounding electrode at the arrangement between the power lines and telecommunication lines. When a multi-path connection between the power lines and telecommunication line circuits exists, the resulting arrangement is known as a ground loop. Whenever a ground loop exists, there are potential for damages or abnormal operations of the telecommunication lines. The power lines can induce the voltage on the communication line. The effects can be calculated by considering the inductances and capacitances. However, if we assume that there are only power lines, it doesn't have a practical meaning because there are conductors with other purpose in the neighborhood of the lines. If we consider that case, we need more complex system. Therefore we suggest more complex system considering the conductors with other purpose in the neighborhood of the lines. The neutral wires and the overhead ground wires are considered for calculating the induced voltage. We assume that there are the messenger wires beside the power line as a result of increased use of them. The main purpose of this paper is a study on a shielding effect of messenger wires in the distribution lines. EMTP(Electro-Magnetic Transients Program) program is used for the induced voltage calculation.

Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings - (음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발-)

  • Chung, Min-Hwa;Cho, Yong-Sang;Yoon, Dong-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.155-161
    • /
    • 1996
  • For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program.

  • PDF

A study on the welding current and voltage signal processing method for the quality evaluation of robotic GMAW (GMAW 품질분석을 위한 신호처리 방법에 관한 연구)

  • Hong, Woo Heon;Ryu, Jeong Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.6
    • /
    • pp.25-31
    • /
    • 2014
  • Gas metal arc welding (GMAW) is currently the most widely used arc welding processes in the industry because of its high metal deposition rate, flexibility and low cost. It is attractive for high-productivity manufacturing applications and is well suited to automatic or robotic welding. Welding voltage and current have a significant impact on the weld bead. However, welding voltage and current are changed variously according to welding condition and user environment, and prediction is impossible. To determine the welding conditions, the welding current and voltage are applied to the appropriate data analysis techniques. In this paper, we used the moving average filter to the welding voltage and current data, and normal and abnormal welding waves were distinguished.

Development of Hybrid AVR for Alternator (교류 발전기용 하이브리드 자동 전압 조정기 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.182-188
    • /
    • 2015
  • An analog AVR has an advantage of short time constant, time to revert again from the abnormal state to a stable one depending on the voltage fluctuations of the load. But the Analog AVR has a disadvantage of large voltage variation according to the load fluctuation. Voltage regulation for digital AVR is very stable, but the time constant is very long compared to that of an analog AVR. Therefore, it indicates that the digital AVR shows unstable output performance in a very large load variations. In this paper, a mixed form of an analog AVR and a digital AVR is proposed. An implemented hybrid AVR has fast time constant and stable voltage regulation capability. Hybrid AVR voltage variations in the load is stable within 1[%] and the voltage stability is also improved. It also showed fast time constant to the level of the analog AVR. Thus hybrid AVR developed in this paper can be used as a power supply for a variety of uses in industry.