• Title/Summary/Keyword: Abnormal condition

Search Result 709, Processing Time 0.025 seconds

A Study on the Electronic Ballast for Neon Lamp (네온 램프용 전자식 안정기에 관한 연구)

  • 강범석;김희준
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.314-318
    • /
    • 1998
  • This paper discusses the development of electronic ballast for neon lamp as an application of a zero voltage switching high frequency inverter. Abnormal increase of secondary voltage due to grounded fault or partial damage of serial arranged loads is clarified and the protection circuit for this abnormal voltage increase is proposed. Also stable lighting condition for removing the unstable characteristics due to different load conditions is proposed.

  • PDF

A study on waveforms with press conditions of Harness terminal (단자(Terminal) 압착조건에 따른 파형의 고찰)

  • Shin, Young-Lok;Yang, Yun-Suk;Kim, Chul-Han;SaGong, Geon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.172-175
    • /
    • 2000
  • The crimping connection is a permanent connection that maintains mechanical and electrical property for a long time by crimping two conductors. In this paper, we have done a basic study to decide normal or abnormal condition depending on crimping. Using PZT piezo-sensor, we have analyzed crimping waveforms according to the crimping height. And hence the normal or abnormal condition of crimping connections in real time could be decided by comparison of crimping waveforms in the cases of normal crimping, over crimping, under crimping and core omitting.

  • PDF

A Study on the Fault Diagnosis System for Combustion System of Diesel Engines Using Knowledge Based Fuzzy Inference (지식기반 퍼지 추론을 이용한 디젤기관 연소계통의 고장진단 시스템에 관한 연구)

  • 유영호;천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.42-48
    • /
    • 2003
  • In general many engineers can diagnose the fault condition using the abnormal ones among data monitored from a diesel engine, but they don't need the system modelling or identification for the work. They check the abnormal data and the relationship and then catch the fault condition of the engine. This paper proposes the construction of a fault diagnosis engine through malfunction data gained from the data fault detection system of neural networks for diesel generator engine, and the rule inference method to induce the rule for fuzzy inference from the malfunction data of diesel engine like a site engineer with a fuzzy system. The proposed fault diagnosis system is constructed in the sense of the Malfunction Diagnosis Engine(MDE) and Hierarchy of Malfunction Hypotheses(HMH). The system is concerned with the rule reduction method of knowledge base for related data among the various interactive data.

Diagnosing the Condition of Air-conditioning Compressors by Analyzing the Waveform of the Raw AE Signal

  • Kim Jeon-Ha;Lee Gam-Gyu;Kang Ik-Soo;Kang Myung-Chang;Kim Jeong-Suk
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.3
    • /
    • pp.14-17
    • /
    • 2006
  • To diagnosis abnormal compressor conditions in an air-conditioner, the acoustic emission (AE) signal, which is derived from wear condition, compressed air, and assembly error, was analyzed experimentally. Burst and continuous type AE signals resulted from metal contact and compressed air, and the raw AE signal of compressors was acquired in the production line. After extracting samples using waveforms, the Early Life Test (ELT) was conducted and the waveform was classified as normal or abnormal. Efficient parameters in the waveform pattern were investigated in time and frequency domains and a diagnosis algorithm for air-conditioners using Neural Network estimation is suggested.

Fault Detection System Development for a Spin Coater Through Vibration Assessment (스핀코터의 진동 평가를 통한 이상 검출 시스템 개발)

  • Moon, Jun-Hee;Lee, Bong-Gu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.47-54
    • /
    • 2009
  • Spin coaters are the essential instruments in micro-fabrication processes, which apply uniform thin films to flat substrates. In this research, a spin coater diagnosis system is developed to detect the abnormal operation of TFT-LCD process in real time. To facilitate the real-time data acquisition and analysis, the circular-buffered continuous data transfer and the short-time Fourier transform are applied to the fault diagnosis system. To determine whether the system condition is normal or not, a steady-state detection algorithm and a frequency spectrum comparison algorithm using confidence interval are newly devised. Since abnormal condition of a spin coater is rarely encountered, algorithm is tested on a CD-ROM drive and the developed program is verified by a function generator. Actual threshold values for the fault detection are tuned in a spin coater in process.

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

Cor Triatrium; A Classic Type and a Type Combibed with Atrial Septal Defect; Report of Two Cases (삼심방증 치험 2례)

  • 손제문
    • Journal of Chest Surgery
    • /
    • v.26 no.7
    • /
    • pp.543-547
    • /
    • 1993
  • Cor triatriatum is a rare entity of congenital heart disease characterized by the presence of a fibrousmuscular diaphragm that subdivides the left atrium into a proximal or "accessory" chamber and a distal or "true" left atrial chamber. In the other hand, cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. We experienced two cases of cor triatriatum. One of them was classical, and the other case was combined with atrial septal defect and all pulmonary veins were drained into the " common pulmonary venous chamber " which connected with right atrium and there was no direct communication between the accessory chamber and true left atrium. The abnormal diaphragms were excised and the atrial septal defect was repaired with pericardial patch in case II. The postoperative courses were not eventful and the patients were discharged with good result, and have been in good condition upto now.n good condition upto now.

  • PDF

Endoscopic features aiding the diagnosis of gastric mucosa-associated lymphoid tissue lymphoma

  • Park, Byung Sam;Lee, Si Hyung
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.85-91
    • /
    • 2019
  • The incidence of gastric mucosa-associated lymphoid tissue (MALT) lymphoma is increasing worldwide, but the diagnosis is difficult. Most patients are asymptomatic or complain of nonspecific gastrointestinal symptoms. As the endoscopic features of gastric MALT lymphoma are variable and nonspecific, the possibility of this condition may be overlooked during esophagogastroduodenoscopy, and it remain undiagnosed. Therefore, this condition needs to be considered when an abnormal mucosa is observed during this procedure. Biopsy performed during endoscopy is the primary diagnostic test, but false negative results are possible; large numbers of samples should be collected from both normal and abnormal mucosae. Endoscopic ultrasonography is useful to assess the depth of invasion and to predict the treatment response. After treatment, follow-up tests are required every 3 months until complete remission is achieved, and annually thereafter. Early diagnosis of gastric MALT lymphoma is difficult, and its diagnosis and follow-up require wide experience and competent endoscopic technique.

Implementation of a Black-Box Program Monitoring Abnormal Body Reactions (부정기적 발생 신체이상 모니터링 블랙박스 프로그램 구현)

  • Kim, Won-Jin;Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.671-677
    • /
    • 2012
  • A black-box program was implemented in order to monitor abnormal symptoms of human body irregularly occurring during sleep. The system consists of sensor probing body signals, auxiliary devices such as the alarm, lamp, network camera, and signal monitoring computer. Various types of sensors, PPG, ECG, EEG, temperature, respiration sensor, G-sensor, and microphone were used to more exactly identify the causes of abnormal symptoms. If a symptom occurs, the system records the patient's condition to provide information being utilized in the treatment. The sensors are attached on some locations of body being proper to check a specific type of abnormal reaction. Based on the normal range and type of measurement data, criteria of signal levels were set to distinguish abnormal reaction. An abnormal signal being probed, the program starts to operate the lamp, alarm, and network camera at the same time and stores the signal and video data.

PVC Classification by Personalized Abnormal Signal Detection and QRS Pattern Variability (개인별 이상신호 검출과 QRS 패턴 변화에 따른 조기심실수축 분류)

  • Cho, Ik-Sung;Yoon, Jeong-Oh;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1531-1539
    • /
    • 2014
  • Premature ventricular contraction(PVC) is the most common disease among arrhythmia and it may cause serious situations such as ventricular fibrillation and ventricular tachycardia. Nevertheless personalized difference of ECG signal exist, performance degradation occurs because of carrying out diagnosis by general classification rule. In other words, the design of algorithm that exactly detects abnormal signal and classifies PVC by analyzing the persons's physical condition and/or environment and variable QRS pattern is needed. Thus, PVC classification by personalized abnormal signal detection and QRS pattern variability is presented in this paper. For this purpose, we detected R wave through the preprocessing method and subtractive operation method and selected abnormal signal sets. Also, we classified PVC in realtime through QS interval and R wave amplitude. The performance of abnormal beat detection and PVC classification is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate the average of 98.33% in abnormal beat classification error and 94.46% in PVC classification.