• Title/Summary/Keyword: AS wire

Search Result 3,140, Processing Time 0.037 seconds

A Study on the Sensing Function of Amorphous Magnetostrictive Wire (아몰퍼스 자왜 와이어의 센싱기능에 관한 연구)

  • 조남희;신용진;서강수;임재근;문현욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.89-92
    • /
    • 1996
  • In this paper, we mention the study on the sensing function of amorphous magneto- striction wire with about 125${\mu}{\textrm}{m}$$\Phi$ in diameter. The wire in fabricated by using injection and quenching method under the high speed rotating water flow. The wire\`s compotion is (Fe$_{75}$ $Co_{25}$)$_{77}$Si$_{8}$B$_{15}$ , and generates sharp Matteucci voltage by large Barkhausen jump effect even the weak magnetic field. In this study, we don\`t use pick-up coil. Instead, we apply external magnetic field of 3.6Oe in the direction orthogonal to the wire. Then, we detect Matteucci voltage of 1.lmV to both side of 20cm amorphous-wire. Thus, we find that the fabricated wire has the function necessary as the high sensitive sensor material.l.al.l.

  • PDF

FRICTIONAL FORCES BETWEEN ORTHODONTIC WIRE AND BRACKET UNDER ARTIFICIAL SALIVA (인공타액하에서 교정선과 Bracket간의 마찰력에 대한 연구)

  • Ko, Jeong-Seok;Yang, Kyu-Ho
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.55-63
    • /
    • 1988
  • It has been suggested that the frictional force between bracket and arch wire may impede the tooth movement. The present study was aimed to compare and analyze the effect of wire size, type of ligation, and duration of ligation on the magnitude of frictional force between cobalt chromium wire and stainless steel bracket under the artificial saliva. The results were as follows: 1. Type of ligation and size of wire were the main influencing factor on the level of friction. 2. Stainless steel ligature generated higher frictional forces than elastomeric module. 3. The rectangular wire consistently exhibited more frictional force values than round wires, while there was no significant difference between frictional forces of round wires. 4. In elastic ligature, frictional force decreased with time. 5. Artificial saliva had no significant influence on the frictional force between cobalt chromium wire and bracket.

  • PDF

Characteristics of Bi2212 Round-wire Depending on Heat Treatment Condition (열처리조건에 따른 Bi-2212 라운드형 선재의 특성)

  • Lee Nam-Il;Jang Gun-Eik;Oh Sang-Su;Ha Dong-Woo;Kim Sang-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.3
    • /
    • pp.1-4
    • /
    • 2006
  • The characteristics of Bi2212 round wire was systematically studied depending on different heat treatment conditions. Initial wire was drawn after routine PIT (Powder In Tube) process. The wire was divided into 3 pieces with 10 cm in length and 2.5 mm in diameter. 3 wires were pre-heat treated separately by different heat treatment schedules, heated in air and nitrogen atmosphere and centrifugally melted. Pre-heated wires were annealed at $845^{\circ}C$ for 40 hours in oxygen atmosphere. SEM results indicate that all pre-heated wires showed highly oriented microstructure. However the wire by centrifugally melted process showed higher density and better electric properties as compared with 2 other wires pre-heated in air and nitrogen atmosphere. The critical current of a centrifugally melted wire was about 18 A in 77 K.

Physiological Reaction to Brassiere Use (브래지어의 착용에 따른 인체 생리반응)

  • Lee, So-Young
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.4
    • /
    • pp.132-142
    • /
    • 2013
  • This study has evaluated the physiological reaction to wearing brassiere as well as the sensations that the wearer feels in order to understand the effect of brassiere use on the human body. Six healthy women in their twenties were used as subjects and the experiment measured the difference in their S.C.L, Skin Temperature, B.V.P and Pulse. The measurements were made in the following conditions: Women not wearing any brassiere, women wearing sports brassiere, and the women wearing wire brassiere. The results showed significant differences in the following areas. 1. S.C.L was found to be the highest when they didn't wear any brassiere, followed by when they wore wire-brassiere and then sports brassiere. 2. The Skin Temperature was found to be the highest when they wore wire-brassiere, followed by when they wore sports brassiere and when they didn't wear any of them. In particular, when they wore sports brassiere, the B.V.P was found to be the highest when they wore none of them, fir skin temperature dropped as time passed. 3.ollowed by when they wore sports brassiere and then wire brassiere. When they wore sports brassiere, they had irregular blood-flow. 4. Pulse was found to be the highest when they didn't wear any of them, followed by when they wore sports brassiere and then wire brassiere. 5. Those who didn't wear any brassiere felt the most chill, followed by those wearing wire brassiere and then sports brassiere. The moisture level was found to be the highest when they wore sports brassiere, followed by when they wore wire brassiere and then when they wore none of them. Comfort level was found to be the best with no brassiere, followed by wire brassiere and then sports brassiere.

Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires (전기장판 열선 결함에 의한 전기화재 원인분석)

  • Song, J.Y.;Sa, S.H.;Nam, J.W.;Kim, J.P.;Cho, Y.J.;Oh, B.Y.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

An Experimental Study on the Fracture Characteristics of Wire Ropes (와이어 로프의 파단특성에 관한 실험적 연구)

  • 김종현;이근오;태순호
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.3-10
    • /
    • 1994
  • This study examines fracture characteristics of wire rope of 6$\times$37+FC 14mm B degree, Which has been widely used for the strength support for machinery, cranes and shipping. The examination Is based on the fellowing experimental conditions. Firstly, this study analyzes the effect of the strength of wlre rope. When number of broken wires is occuring at the level of 5%, 10% and 15% degree respectively in the following two cases:1) Case of broken down to each strand equally. 2) Case of broken down to one strand only. Secondly, this study analyzes the effect of corrosion on the strength of wire rope. Corrosion times are 72hours, 144hours and 216hours corrosion respectively under following conditions. 1) Case of only a corrosion without wire breaking. 2) Case of corrosion after 5% degree wire breaking to each strand equally. Some outcomes of these experiment are as follows. 1) From the of tension test, We can find that the ratio of strength reduction case of wire broke down to one strand concentrically is greater than that ratio case of broke down to each strand equally. 2) From the corrosion test, We can also find that the ratio of strength reduction case of corroded after 5% degree wire breaking to each strand equally Is greater than that ratio case of corroded without wire breaking. 3) After comparing theoretical fracture load of wires with experimental fracture load of wires, we can find the fracture load of the case of broken down to each strand equally is most similar to theoretical fracture load. 4) It is proposed that safety rules on wire rope in the Industrial safety and healthy labor of law have to change “breaking over 10% of number of wires in one strand of wire rope(excluded filler wire )”has to be replaced by“breaking over 10% of number of all wires in all strand of wire rope(excluded filler wire)”

  • PDF

Development of Accessories for 345kV XLPE Cable with Small Size Conductor (345kV XLPE 소도체 Cable용 접속함의 개발)

  • Kim, H.J;Kim, K.Y;Park, J.K.;Song, J.H.;Shin, H.D.;Park, K.L.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1775-1777
    • /
    • 2004
  • Taihan Electric Wire Co. developed accessories(PJ, EB-G, EB-A, EB-O) for 345kV XLPE $1C{\times}600mm^2$ cable as a small size conductor cable, after installed 345kV XLPE $1C{\times}600mm^2$ cable, PJ and EB-G on Youngseo${\sim}$Youngdeungpo project KEPCO planed in 2003. All of 345kV XLPE $1C{\times}600mm^2$ cable Accessories are finished the type tests successfully. Straight joint as a Prefabricated Joint(PJ) had shorter the days of assembling than those of TMJ used on the 154kV XLPE Cable. Particularly, the use of clean booth to prevent the dusts and the penetration of water also had made the quality of jointing improved.

  • PDF

Development of Real-time Remote Detection System for Crane Wire Rope Defect (크레인 와이어 로프의 실신간 원격 결함탐지 시스템 개발)

  • Lee Kwon Soon;Suh Jin Ho;Min Jeong Tak;Lee Young Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • The wire rope of container crane is a important component to container transfer system and is used in a myriad of various applications such as elevator, mine hoist, construction machinery, and so on. If it happen wire rope failures in operating, it may lead to the safety accident and economic loss, which is productivity decline, competitive decline of container terminal, etc. To solve this problem, we developed the active and portable wire rope fault detecting system. The developed system consists of three parts that are the fault detecting, signal processing, and remote monitoring part. All detected signal has external noise or disturbance according to circumstances. Therefore we applied to discrete wavelet transform to extract a signal from noisy data that was used filter. As experimental result, we can reduce the expense for container terminal because of extension of exchange period of wire rope for container crane and this system is possible to apply in several fields to use wire rope.

Effects of Wire speed Fluctuation on Arc Stability in GMA Welding (GMAW에서 와이어 송급속도의 변동이 아크안정성에 미치는 영향에 관한 연구)

  • 신현욱;최용범;성원호;장희석
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.85-102
    • /
    • 1995
  • Weld quality of GMA welding processes is closely related to arc stability. Although many researches on arc stability have been performed, real-time estimation of arc stability has not been attempted. For instance, Mita proposed a off-line statistical method in which short circuiting and arcing time, and voltage and current wave forms were sampled to assess arc stability. But this method is not suitable to assess arc stability for GMA welder which employ inverter power source due to its controlled current and voltage wave forms. In this paper, the relationship between are stability and wire feed rate fluctuation is analyzed to propose new criterion for inverter power source. When arc voltage and arc current and arcing time are analyzed, we can assess arc stability only for short circuit transfer mode. When wire feed rate is analyzed, we can estimate arc stability udner the condition of spray transfer mode as well. Hence, the wire feed rate is chosen for monitoring process variable to cover possible metal transfer modes in GMAW. Through this research, it has been identified that arc stability in GMA welding processes is closely related to wire fed rate. When inverter power source is used, conventional statistical method of estimating arc stability, such as Mita index, is no longer valid due to its controlled voltage and current wave forms. Arc stability has been also examined in phase plane diagram.

  • PDF

Fabrication of Cu-Zn Alloy Nano Powders by Wire Explosion of Electrodeposited Wires (도금선재의 전기선폭발을 이용한 Cu-Zn 합금 나노분말 제조)

  • Kim, Won-Baek;Park, Je-Shin;Suh, Chang-Yeul;Lee, Jae-Chun;Oh, Yong-Jun;Mun, Jeong-Il
    • Journal of Powder Materials
    • /
    • v.14 no.1 s.60
    • /
    • pp.38-43
    • /
    • 2007
  • Cu-Zn alloy nano powders were fabricated by the electrical explosion of Zn-electroplated Cu wire along with commercial brass wire. The powders exploded from brass wire were composed mainly of ${\alpha},{\beta},\;and\;{\gamma}$ phases while those from electroplated wires contained additional Zn-rich phases as ${\varepsilon}$, and Zn. In case of Zn-elec-troplated Cu wire, the mixing time of the two components during explosion might not be long enough to solidify as the phases of lower Zn content. This along with the high vapor pressure of Zn appears to be the reason for the observed shift of explosion products towards the high-Zn phases in electroplated wire system.