• Title/Summary/Keyword: AP position

Search Result 188, Processing Time 0.029 seconds

PTV Margins for Prostate Treatments with an Endorectal Balloon (전립선 암의 방사선치료 시 직장 내 풍선삽입에 따른 계획표적부피마진)

  • Kim, Hee-Jung;Chung, Jin-Beom;Ha, Sung-Whan;Kim, Jae-Sun;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.166-176
    • /
    • 2010
  • Purpose: To determine the appropriate prostate planning target volume (PTV) margins for 3-dimensitional (3D) conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) patients treated with an endorectal balloon (ERB) under our institutional treatment condition. Materials and Methods: Patients were treated in the supine position. An ERB was inserted into the rectum with 70 cc air prior to planning a CT scan and then each treatment fraction. Electronic portal images (EPIs) and digital reconstructed radiographs (DRR) of planning CT images were used to evaluate inter-fractional patient's setup and ERB errors. To register both image sets, we developed an in-house program written in visual $C^{++}$. A new method to determine prostate PTV margins with an ERB was developed by using the common method. Results: The mean value of patient setup errors was within 1 mm in all directions. The ERB inter-fractional errors in the superior-inferior (SI) and anterior-posterior (AP) directions were larger than in the left-right (LR) direction. The calculated 1D symmetric PTV margins were 3.0 mm, 8.2 mm, and 8.5 mm for 3D CRT and 4.1 mm, 7.9 mm, and 10.3 mm for IMRT in LR, SI, and AP, respectively according to the new method including ERB random errors. Conclusion: The ERB random error contributes to the deformation of the prostate, which affects the original treatment planning. Thus, a new PTV margin method includes dose blurring effects of ERB. The correction of ERB systematic error is a prerequisite since the new method only accounts for ERB random error.

An investigation Of IntraFraction Motion Correction For Lung Stereotactic Body Radiation Therapy By Using IntraFraction Cone Beam Computed Tomography (폐암 환자의 정위적 체부 방사선 치료 시 IntraFraction CBCT를 이용한 치료 중 자세 오차 교정에 대한 고찰)

  • Song, Hyeong Seok;Cho, Kang Chul;Park, Hyo Kuk;Yoon, Jong Won;Cho, Jung Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Purpose: The purpose is to correct for position errors caused by long treatment times. By correcting the target motion that can occur during lung SBRT using IntraFraction CBCT. Methods and materials: We analyzed retrospectively the IFM data of 14 patients with two treatment arc in the treatment plan for lung cancer with stereotactic radiotherapy. An IntraFraction Motion was applied to the Arccheck phantom to acquire the Gamma index data. Results : IntraFraction Motion during the first treatment arc is in the left-right(LR), superiorinferior(SI), anterior-posterior(AP) directions were $0.16{\pm}0.05cm$, 0.72 cm(max error), $0.2{\pm}0.14cm$, 1.26 cm, $0.24{\pm}0.08cm$, 0.82 cm and rotational directions was $0.84{\pm}0.23^{\circ}$, $2.8^{\circ}$(pitch), $0.72{\pm}0.23^{\circ}$, $2.5^{\circ}$(yaw), $0.7{\pm}0.19^{\circ}$, $2^{\circ}$(roll). IntraFraction Motion during the second treatment arc is in the LR, SI, AP directions were $0.1{\pm}0.04cm$, 0.37 cm, $0.14{\pm}0.17cm$, 2 cm, $0.12{\pm}0.04cm$, 0.5 cm and rotational directions was $0.45{\pm}0.12^{\circ}$, $1.3^{\circ}$, $0.37{\pm}0.1^{\circ}$, $1^{\circ}$, $0.35{\pm}0.1^{\circ}$, $1.2^{\circ}$. Gamma index pass rates were $82.64{\pm}10.51%$, 48.4 %. Conclusions : In this study, we examined the validity of IntraFraction Motion correction in lung SBRT and the efficiency of IntraFraction CBCT. Due to the nature of SBRT treatment, IFM may increase due to the increased treatment time. It is believed that the increase in IFM with the increase in treatment time can be improved with the use of FFF Beam and additional position correction using CBCT during treatment.

Wireless LAN-based Vehicle Location Estimation in GPS Shading Environment (GPS 음영 환경에서 무선랜 기반 차량 위치 추정 연구)

  • Lee, Donghun;Min, Kyungin;Kim, Jungha
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.1
    • /
    • pp.94-106
    • /
    • 2020
  • Recently, the radio navigation method utilizing the GPS(Global Positioning System) satellite information is widely used as the method to measure the position of objects. As GPS applications become wider and fields based on various positioning information emerge, new methods for achieving higher accuracy are required. In the case of autonomous vehicles, the INS(Inertial Navigation System) using the IMU(Inertial Measurement Unit), and the DR(Dead Reckoning) algorithm using the in-vehicle sensor, are used for the purpose of preventing degradation of accuracy of the GPS and to measure the position in the shadow area. However, these positioning methods have many elements of problems due not only to the existence of various shaded areas such as building areas that are continually enlarged, tunnels, underground parking lots and but also to the limitations of accumulation-based location estimation methods that increase in error over time. In this paper, an efficient positioning method in a large underground parking space using Fingerprint method is proposed by placing the AP(Access Points) and directional antennas in the form of four anchors using WLAN, a popular means of wireless communication, for positioning the vehicle in the GPS shadow area. The proposed method is proved to be able to produce unchanged positioning results even in an environment where parked vehicles are moved as time passes.

The Effect of Moosim-Gi-Gong Doinbeop on Treatment of Low Back Pain (무심기공 도인법이 요통치료에 미치는 효과)

  • Jang, Sang Chul;Chong, Myong Soo;Pi, Chien Mei;Ahn, Hun Mo;Lee, Jae Heung;Roh, Ju Hee;Bae, Jae Ryong
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.18 no.1
    • /
    • pp.1-26
    • /
    • 2018
  • The objective of this study is to verify the effects of Moosim-Gi-Gong Doinbeop on low back pain targeting low back pain patients hospitalized in Korean medicine hospitals. For the study, 44 adult female and male patients hospitalized with low back pain at M Korean Medicine Hospital and H Korean Medicine Hospital located in Gimpo, Gyeonggi Province were recruited. The subjects had a temperature difference between left and right 湧泉(KI1) of over 0.5℃ through infrared thermographic imaging, and 23 of them were classified in the control group for retrospective analysis based on the test records. Infrared thermographic imaging, X-ray pelvic AP view - standing position, a sit-and-reach test and a VAS survey were employed for detection, and IBM SPSS Statistics 24 for the statistical process. The results were rounded down to three decimal places as in an average±standard deviation, and the significance level was 0.05 to be evaluated significant if p<0.05. The result of the study is as follows: 1. In the comparison between before and after conducting Moosim-Gi-Gong Doinbeop, the meaningful difference was shown in the experimental group in all indicators. But Indicators except for the temperature difference between right and left 湧泉(KI1)(difference between before and after) and In displaced pelvic correction indicators on the X-ray showed a significant difference in the control group. 2. As for the variation widths of the experimental group and the control group, the former showed significant temperature differences between 印堂(EX-HN3) and 關元(CV4) and right and left 湧泉(KI1); difference variations of anteflexion; and changes in PI and In displacement on the X-ray. 3. As for changes in the experimental group according to demographic characteristics, gender, age and degree of obesity did not show significant differences in all indicators. However, those who experienced back pain for more than six months in the experimental group showed the biggest body temperature differences between 印堂(EX-HN3) and 關元(CV4), while other indicators had no significant difference. As a result, patients who received Korean medicine treatment showed relieved back pain and improvement in pelvic correction and sports activity; however, those who got Moosim-Gi-Gong Doinbeop together showed more clearer improvement effects in pelvic correction and sports activity.

Localization using Neural Networks and Push-Pull Estimation based on RSS from AP to Mobile Device (통신기지국과 모바일장치간의 수신신호강도를 기반으로 하는 신경망과 푸쉬-풀 평가를 이용한 위치추정)

  • Cho, Seong-Jin;Lee, Sung-Young
    • The KIPS Transactions:PartD
    • /
    • v.19D no.3
    • /
    • pp.237-246
    • /
    • 2012
  • Although the development of Global Positioning System (GPS) are more and more mature, its accuracy is just acceptable for outdoor positioning, not positioning for the indoor of building and the underpass. For the positioning application area for the indoor of building and the underpass, GPS even cannot achieve that accuracy because of the construction materials while the requirement for accurate positioning in the indoor of building and the underpass, because a space, a person is necessary, may be very small space with several square meters in the indoor of building and the underpass. The Received Signal Strength (RSS) based localization is becoming a good choice especially for the indoor of building and the underpass scenarios where the WiFi signals of IEEE 802.11, Wireless LAN, are available in almost every indoor of building and the underpass. The fundamental requirement of such localization system is to estimate location from Access Point (AP) to mobile device using RSS at a specific location. The Multi-path fading effects in this process make RSS to fluctuate unpredictably, causing uncertainty in localization. To deal with this problem, the combination for the method of Neural Networks and Push-Pull Estimation is applied so that the carried along the devices can learn and make the decision of position using mobile device where it is in the indoor of building and the underpass.

Effect of Internal Circuit Faults of Non-reference Type APS Malfunction on Commercial and Tactical Vehicles (참조센서가 없는 상용/전술차량용 APS내부 회로 불량이 오작동에 미치는 영향)

  • Jo, Yong Jin;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.163-170
    • /
    • 2016
  • In the condition of electronic controlled acceleration system, APS Sensor is the only and the most important parts to reflect the will of driver. Especially, the non-reference type APS is the critical part of this system. It can't provide the cross-reference values and it will make the vehicle goes into the 'NMC(Non-moveable condition)' or 'Limp-home mode' on the malfunction situation easier. If the situation is happened, it's very dangerous condition for the drivers, soldiers and war material systems of battlefield. The electronic control is not a necessary system for the tactical vehicles. The tactical vehicles must be prepared the manual control system independently from the electronic control system to escape, save and rescue the soldier's life and war materials. Therefore it was studied the water-penetrated broken APS output. If the output value was changed without driver's will, even the cross-reference type APS, it will effect the uncontrollable engine RPM changing or the performance down on limp-home mode. It means the manual control system of tactical vehicle is needed for any kinds of APS.

The Study of Grashey Method Viewing the Glenohumeral(shoulder) Joint (어깨관절의 접시오목을 나타내는 Grashey법에 대한 연구)

  • Lee, Jaeseob;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.331-335
    • /
    • 2015
  • Consideration of Glenohumeral joint's image with the Changed Body angle of the Glenohumeral joint's Oblique Position in Erect Position. Glenohumeral joint's of Grashey method is a shoulder oblique method available to view the shoulder joint. Grashey method projects AP view of the Glenohumeral joint's so that the Humerus head's subluxation or joint degeneration can be easily visualized. However in this view, the patients, erect position, have to keep their body obliquely. Oblique position is will be needed to get the good quality Glenohumeral joint's view. Therefore, we thought of examining a method which shows the Glenohumeral joint's well by angling the patient one side upward in erect position. For this study, total 20 subject with no history of neurological or psychiatric illness, were recruited for examinations. They consisted of 13 mails and 7 femails, Statistic group analysis was performed with ANOVA test. Score of the evaluation of the expects were $30^{\circ}$ at $0.40{\pm}0.499$, $35^{\circ}$ at $1.34{\pm}0.657$, $40^{\circ}$ at $1.84{\pm}0.573$, $45^{\circ}$ at $0.76{\pm}0.649$, and they were significant(P<0.05). The degree of $40^{\circ}$ views were shown to yield good quality shoulder oblique images.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

THE CORRELATION BETWEEN CRANIAL BASE SIZE, SHAPE AND HEAD POSTURE, AND THE POSITION OF MAXILLO-FACIAL STRUCTURES (두개저의 크기, 형태 및 두부자세와 악안면구조의 위치적 상관관계)

  • Hong, Yong-Seok;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.743-760
    • /
    • 1997
  • This study was done to evaluate the correlations between the size, the form of the cranial base, head posture and the horizontal and vertical position of craniofacial structures. For this purpose, 100 cephalometric radiographs were taken from the sample composed of 51 male and 49 female, 12 measurement criteria and 37 reference points were established and digitized, then calculation was performed for the values of measurement variables and the horizontal and vertical position of reference points. The correlations be4ween them were analyzed statistically and mean facial diagrams were constructed and compared with the selected groups which were composed of 10 Samples each as large and small group from the measurement value. The following results were obtained: 1. The angles n-s-ba and n-s-ar as variables for the ion of cranial base correlated highly to the horizontal and vertical position of reference points in the cervical column with statistical significance($0.1\%$ level). 2. The angles n-s-ba and n-s-ar as variables for the form of cranial base correlated to the horizontal position of the reference points in the facial structure with statistical significance($1\%$ level), but not to the vertical position of them($5\%$ level). 3. The length n-s, s-ba, and n-ar as variables for the size of cranial base were correlated th the position of craniofacial structures in various ways, but in general, highly correlated to the horizontal and vertical position of midfacial structures around the teeth and alveolar area. 4. the angle NSL/CVT and NSL/OPT as postural variables tot the inclination of cranial base and cervical column were correlated to the horizontal position of the craniofacial structures with statistical significance($1\%$ level), but not to the vortical position of them($5\%$ level). 5. The angle OPT/HOR and CVT/HOR as postural variables lot the inclination of cranial base and true horizontal line were not correlated to the horizontal and vertical position of the craniofacial structures with statistical significance($5\%$ level). 6. The correlation between the measurement variables and horizontal and vortical positions of the reference poits in soft tissue were shown as similar to the related hard tissue points.

  • PDF

Case study of application on pelvic manipulation which low back pain patient in unilateral weight bearing due to pelvic imbalance (골반 불균형에 의한 편측체중지지 요통환자의 골반도수교정 적용사례)

  • Kim, Han-Il;Kim, Sang-Su;Kim, Gee-Sun;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Purpose: to recognized that influence of decrease low back pain, change pelvic structure and balance control on unilateral weight bearing after application on pelvic manipulation which low back pain patient in unilateral weight bearing due to pelvic imbalance. Methods: The patient with low back pain in unilateral weight bearing due to pelvic imbalance was 39year female. one subject received intervention of pelvic manipulation on sidelying position and reaching exercise on sitting position which during 2 weak at the 3 time per a weak, each 30 minutes. outcomes measured were Facia l Action Coding System(FACS), Radiograph(Lumbar-Spine Anteroposterior AP.), Pressure Scan. Results: The results of this study were summarized below : 1. FACS score were Pre: min.4 - max.6 and Post: min.2 - max.4. 2. Radiograph measured Ilium width were Pre: Lt.14cm, Rt.12.7cm and Post: Lt.13.4cm, Rt.13cm which discrepancy of Ilium height were Pre: 1cm and Post: 0.2cm. 3. Pressure scan measured Pre: Lt. 36.8%, Rt.40.2% and Post: Lt.41.3%, Rt.36.2%. Conclusion: Pelvic manipulation applied a patient with low back pain in unilateral weight bearing due to pelvic imbalance suggest that can decrease low back pain, change pelvic structure and balance control on unilateral weight bearing.

  • PDF