• Title/Summary/Keyword: AGC

Search Result 279, Processing Time 0.029 seconds

PID Control with Fuzzy Compensation for Electric Power Generation Unit (보상형 퍼지알고리즘을 이용한 전력발전기의 PID 제어)

  • Hak Roh, Lee
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.217-220
    • /
    • 2004
  • Controller that is designed in this paper is form that apply PID controller about Fuzzy algorithm. Fuzzy Controller that using this paper is can speak that compensation style fuzzy controller as form to solidify action of PID controller for plant. This is not form that autotuning the each PID coefficient. We Apply and examined the response character to AGC(Automatic Generation Control) system using designed controller.

  • PDF

Design and Fabrication of RF Receiver Module for IMT-2000 Handset (IMT-2000 단말기용 RF 수신모듈 설계 및 제작)

  • 황치전;이규복;박인식;박규호;박종철
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.817-820
    • /
    • 1999
  • In this paper, we describes RF receiver module for IMT-2000 handset with 5MHz channel bandwidth. The fabricated RF receiver module consists of Low Noise Amplifier-, RF SAW filter, Down-converter, IF SAW filter, AGC and PLL Synthesizer. The NF and IIP3 of LNA is 0.8㏈, 3㏈m at 2.14㎓, conversion gain of downconverter is l0㏈, dynamic range of AGC is 80㏈, and phase noise of PLL is -100 ㏈m, at 100KHz. The receiver sensitivity is -110㏈m, adjacent channel selectivity is -48㏈m.

  • PDF

Development of Displacement Measuring Sensor for Roll Eccentricity Contro1 at Hot Strip Mill (롤 편심제어를 위한 편심 측정장치 개발)

  • 전종학
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.167-167
    • /
    • 2000
  • This study aims at the development of REC sensor causing the gauge error in the hot strip rolling process, and the improvement of the hydraulic AGC (Automatic Gauge Control) system. The gauge error outbreaks from the various reasons, however, mainly the roll eccentricity is considered to cause a such kind of error. In the study, the REC (Roll Eccentricity Control System) sensor is designed using sensor An On - line test of the system shows the comprehensive effects of controlling the gauge error of the hot strip. On - Line test shows the possibility of enhancing the accuracy for gauge.

  • PDF

Design of an 8-bit 230MSPS Analog Flat Panel Interface for TFT-LCD Driver (TFT-LCD 드라이버를 위한 8-bit 230MSPS Analog Flat Panel InterFACE의 설계)

  • Yun, Seong-Uk;Im, Hyeon-Sik;Song, Min-Gyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • In this paper, an Analog Flat Panel interface(AFPI) which supports for UXGa(Ultar extended Graphics Array)-Compatible TFT LCD Driver is designed. The Proposed AFPI is composed of 8-b ADC, Automatic Gain Control(AGC), Low-Jitter PLL. In order to obtain a high speed and low power consumption, an efficient architecture of 8-bit ADC is proposed, whose FR(Folding Rate) is 8, NFB(Number of Folding Block) is 2, and IR (Interpolating Rate) is 16. We can get high SNDR by adopting distributed track and hold circuits. Also a programmable AGC which is possible to control gain and clamp, and a low-jitter PLL are proposed. The chip has been fabricated with 0.25${\mu}{\textrm}{m}$ 1-poly S-metal n-well CMOS technology. The effective chip area is 3.6mm $\times$ 3.2mm and it dissipates about 602㎽ at 2.5V power supply. The INL and DNL are within $\pm$ 1LSB. The measured SNDR is about 43㏈, when the input frequency is 10MHz at 200MHz clock frequency.

A case study of advanced gastric cancer patient with metastasis to liver (간전이를 동반한 진행성 위암 환자 1례(例)에 대한 임상보고(臨床報告))

  • Song Kee-Cheol;Choi Byung-Lyul;An Jung-Jo;Lim Seung-Min;Kim Man-Ho;Lee Ji-Young;Yoo Hwa-Seung;Cho Jung-Hyo;Lee Yeon-Weol;Son Chang-Gue;Cho Chong-Kwan;Kim Yeon-Jin
    • The Journal of Internal Korean Medicine
    • /
    • v.24 no.4_2
    • /
    • pp.1067-1074
    • /
    • 2003
  • Objectives : This study was designed to evaluate the effects of traditional oriental therapies(TOT) on advanced gastric cancer(AGC) patient with metastasis to liver. Methods : We retrospectively analyzed the medical record of a case of AGC patient in stage IV with metastasis to liver who had been treated with TOT for 5 months continuously in East-West Cancer Center of Oriental Hospital of Daejeon University from 5 March 2003 through 22 July 2003. Results : After treated with TOT for the 5 months, most of symptoms were disappeared or improved and tumor size was decreased on abdominal CT compared with the previous result. The hematological results and tumor markers were not increased. Conclusions : From the above results, it could be suggested that TOT have effects on improving symptoms and quality of life as a supportive or curative therapy for AGC patients.

  • PDF

Online Automatic Gauge Controller Tuning Method by using Neuro-Fuzzy Model in a Hot Rolling Plant

  • Choi, Sung-Hoo;Lee, Young-Kow;Kim, Sang-Woo;Hong, Sung-Chul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1539-1544
    • /
    • 2005
  • The gauge control of the fishing mill is very important because more and more accurately sized hot rolled coils are demanded by customers recently. Because the mill constant and the plasticity coefficient vary with the specifications of the mill, the classification of steel, the strip width, the strip thickness and the slab temperature, the variation of these parameters should be considered in the automatic gauge control system(AGC). Generally, the AGC gain is used to minimize the effect of the uncertain parameters. In a practical field, operators set the AGC gain as a constant value calculated by FSU (Finishing-mill Set-Up model) and it is not changed during the operating time. In this paper, the thickness data signals that occupy different frequency bands are respectively extracted by adaptive filters and then the main cause of the thickness variation is analyzed. Additionally, the AGC gain is adaptively tuned to reduce this variation using the online tuning model. Especially ANFIS(Adaptive-Neuro-based Fuzzy Interface System) which unifies both fuzzy logics and neural networks, is used for this gain adjustment system because fuzzy logics use the professionals' experiences about the uncertainty and the nonlinearity of the system. Simulation is performed by using POSCO's data and the results show that proposed on-line gain adjustment algorithm has a good performance.

  • PDF

Wear, microleakage and plastic deformation of an implant-supported chair-side bar system

  • Mehl, Christian Johannes;Steiner, Martin;Ludwig, Klaus;Kern, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2015
  • PURPOSE. This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+$M{\acute{e}}taux$, Switzerland). MATERIALS AND METHODS. Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, ${\alpha}{\leq}.05$). RESULTS. All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION. Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.

Time Pickoff method using an Automatic Gain Control (자동 이득 조절(AGC) 기반의 Time pickoff 회로)

  • Lim, Han-Sang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.80-85
    • /
    • 2011
  • A time-pickoff circuit used for time measurement suffers from a timing error due to the dependence of the generation time of a timing pulse on the size of the input signal, i.e., time walk. In this study, a time-pickoff method, which employs an automatic gain control (AGC) circuit, is proposed for reducing the timing error. The AGC circuit is added to the input of the comparator, and it renders the sizes of input signals of the comparator relatively uniform. The performance of the proposed time-pickoff method is analyzed using the SPICE simulation, and experiments are performed to confirm the analytical results. The measured time walk is reduced to 2.000 ns by 65% for input signals with a dynamic range of 20 dB as compared to a typical leading-edge discriminator.

A CMOS RF Power Detector Using an AGC Loop (자동 이득제어 루프를 이용한 CMOS RF 전력 검출기)

  • Lee, Dongyeol;Kim, Jongsun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.101-106
    • /
    • 2014
  • This paper presents a wide dynamic range radio-frequency (RF) root-mean-square (RMS) power detector using an automatic gain control (AGC) loop. The AGC loop consists of a variable gain amplifier (VGA), RMS conversion block and gain control block. The VGA exploits dB-linear gain characteristic of the cascade VGA. The proposed circuit utilizes full-wave squaring and generates a DC voltage proportional to the RMS of an input RF signal. The proposed RMS power detector operates from 500MHz to 5GHz. The detecting input signal range is from 0 dBm to -70 dBm or more with a conversion gain of -4.53 mV/dBm. The proposed RMS power detector is designed in a 65-nm 1.2-V CMOS process, and dissipates a power of 5 mW. The total active area is $0.0097mm^2$.

Prognostic Impact of Extended Lymph Node Dissection versus Limited Lymph Node Dissection on pN0 Proximal Advanced Gastric Cancer: a Propensity Score Matching Analysis

  • Park, Sung Hyun;Son, Taeil;Seo, Won Jun;Lee, Joong Ho;Choi, Youn Young;Kim, Hyoung-Il;Cheong, Jae-Ho;Noh, Sung Hoon;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.212-224
    • /
    • 2019
  • Purpose: Splenic hilar lymph node dissection (LND) during total gastrectomy is regarded as the standard treatment for proximal advanced gastric cancer (AGC). This study aimed to investigate whether splenic hilar LND or D2 LND is essential for proximal AGC of pT2- 4aN0M0 stage. Materials and Methods: Data of curative total gastrectomies (n=370) performed from 2000 to 2010 for proximal AGC of pT2-4aN0 stage were retrospectively reviewed. Clinicopathological characteristics and long-term outcomes were compared using propensity score matching between patients who underwent splenectomy (n=43) and those who did not (n=327) and between patients who underwent D2 LND (n=122) and those who underwent D1+ LND (n=248). Results: Tumors of larger size and a more advanced T stage and significantly lower overall and relapse-free survival (P<0.001) were observed in the splenectomy group than in the 2 spleen-preserving groups. Before propensity score matching, worse overall and relapse-free survival (P<0.001) was observed in the splenectomy group than in the non-splenectomy group. After matching, although the overall survival became similar (P=0.123), relapse-free survival was worse in the splenectomy group (P=0.021). Compared with D1+ LND, D2 LND had no positive impact on the overall (P=0.619) and relapse-free survival (P=0.112) after propensity score matching. Conclusions: Splenic hilar LND with or without splenectomy may not have an oncological benefit for patients with pathological AGC with no LN metastasis.