• Title/Summary/Keyword: AGC

Search Result 279, Processing Time 0.023 seconds

Characterization of Nonaflatoxigenic Aspergillus flavus/oryzae Strains Isolated from Korean Traditional Soybean Meju

  • Sang-Cheol Jun;Yu-Kyung Kim;Kap-Hoon Han
    • Mycobiology
    • /
    • v.50 no.6
    • /
    • pp.408-419
    • /
    • 2022
  • Filamentous fungi that could be classified into Aspergillus flavus/oryzae were isolated from traditionally fermented meju commercially available in Korea. The samples were analyzed for aflatoxin B1 and ochratoxin A contamination by HPLC; however, no toxin was detected. In addition, fungal and bacterial metagenomic sequencing were performed to analyze the microbial distribution in the samples. The results revealed that the distribution and abundance of fungi and bacteria differed considerably depending on the production regions and fermentation conditions of the meju samples. Through morphological analysis, ITS region sequencing, and assessment of the aflatoxin-producing ability, a total of 32 A. flavus/oryzae strains were identified. PCR analysis of six regions with a high mutation frequency in the aflatoxin gene cluster (AGC) revealed a total of six types of AGC breaking point patterns. The A. flavus/oryzae strains did not exhibit the high amylase activity detected in the commercial yellow koji strain (starter mold). However, their peptidase and lipase activities were generally higher than that of the koji isolates. We verified the safety of the traditionally fermented meju samples by analyzing the AGC breaking point pattern and the enzyme activities of A. flavus/oryzae strains isolated from the samples. The isolated strains could possibly be used as starter molds for soybean fermentation.

Analysis of the cause of dose delivery errors due to changes in abdominal gas volume during MRgART pancreatic cancer (췌장암 MRgART시 복부가스용적 변화에 의한 선량전달오류 원인 분석)

  • Ha, Min Yong;Son, Sang Jun;Kim, Chan Yong;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.73-83
    • /
    • 2020
  • Purpose: The purpose of this study is to confirm the matching of the electron density between tissue and gas due to variation of abdominal gas volume in MRgART (Magnetic Resonance-guided Adaptive Radiation Therapy) for pancreatic cancer patients, and to confirm the effect on the dose change and treatment time. Materials and Methods: We compared the PTV and OAR doses of the initial plan and the AGC(Abdominal gas correction) plans to one pancreatic cancer patient who treated with MRgART using the ViewRay MRIdian System (Viewray, USA) at this clinic. In the 4fx AGC plans, Beam ON(%) according to the patient's motion error was checked to confirm the effect of abdominal gas volume on treatment time. Results: Comparing the Initial plan with the average value of AGC plan, the dose difference was -7 to 0.1% in OAR and decreased by 0.16% on average, and in PTV, the dose decreased by 4.5% to 5.5% and decreased by 5.1% on average. In Adaptive treatment, as the abdominal gas volume increased, the Beam ON(%) decreased. Conclusion: Abdominal gas volume variation causes dose change due to inaccurate electron density matching between tissue and gas. In addition, if the abdominal gas volume increases, the Beam ON(%) decreases, and the treatment time may increase due to the motion error of the patient. Therefore, in MRgART, it is necessary to check the electron density matching and minimize the variability of the abdominal gas.

A Fully Digital Automatic Gain Control System with Wide Dynamic Range Power Detectors for DVB-S2 Application (넓은 동적 영역의 파워 검출기를 이용한 DVB-S2용 디지털 자동 이득 제어 시스템)

  • Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.58-67
    • /
    • 2009
  • This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25 dB to the desired level within $10{\mu}s$. It is implemented in a $0.18{\mu}m$ CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8 nV/$\sqrt{Hz}$ input referred noise, and 5-dBm $IIP_3$ at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100 MHz input.

A Clinical Study on Binaural Hearing Aid (양이 보청효과에 관한 연구)

  • 김기령;김영명;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.9.2-9
    • /
    • 1978
  • Monaural and binaural hearing aid performance under quiet and noisy conditions were compared in regard to (1) the degree of hearing impairment, (2) the symmetry of pure tone audiogram, (3) the automatic gain control of the hearing aid. (4) hearing impairement with recruitment and, word discrimination ability. Performance using binaural hearing aids was consistently superior to that using monaural hearing aids. The results were as follows. 1. Speech detection thresholds were enhanced by a mean of 4.25dB when tested with danavox 747 PP stereo type hearing aid and by a mean of 4.12 dB when tested hearing aids connected seperately to the right and left ears. 2. Binaurally tested speech reception thresholds were superior to monaurally tested thresholds by a mean of 3.56dB when tested in quiet and by a mean of 5.56dB when tested in noise. 3. Binaurally tested word discrimination scores were also superior by a mean of 17.09% in quiet and by a mean 19.63% in noise. 4. Both SRT and word discrimination scores were performed best by subjects with moderately-severe impairement. The performance by one mildly impaired subject was the poorest of all performances. The levels of performance order were; moderately-severe loss, severe loss. moderate loss and mild loss. 5. The data obtained using AGC aids when compaired with that of linear amplification show that when AGC aids were worn in both ears. the results were very poor but when one AGC aid was worn in one ear and linear amplification in the other. the results were good. 6. The advantages of binaural hearing aids were obvious even in cases 1) with great diferences in hearing thresholds between right and left ears, 2) when the subject was unable to discriminate words without vision and. 3) when the subject had extreme recruitme t phenomenon.

  • PDF

Computer-Aided Optimal Design of Color TV Circuits (디지털 컴퓨터에 의한 칼라 TV의 최적 설계방식 연구)

  • 김덕진;박인갑
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.6
    • /
    • pp.52-65
    • /
    • 1978
  • Computer-aided design of color TV circuits has been tried using circuit analysis programs. Due to the complexity of colorplexed composite video signals of the color TV, conventional methods are difficult to apply in the color TV circuit design. This paper describes how to design Y video circuit, chroma cicruit, AGC circuit, and sync separator circuit of color TV using analysis programs.

  • PDF

A Study on the Position Detection Device for a Hybrid Type Linear Pulse Motor (HB형 LPM의 위치검출장치에 관한 기초연구)

  • 신춘식;김남호;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 1996
  • In recent years, as the electonic industry has become more advanced, the LPM(Linear Pulse Motor) has appeared in a wide range of applications because of easier control, operation by open-loop control, high positioning accuracy, and retrieval of position or velocity data by the input pulses. In this study, we deal with the development of a position detection device attached to a hybrid LPM in our laboratory. Precise position detection signals could be sensed by the synchronous rectifier method from the LPM stator scale. In addition, we can keep the amplitude constant by using an AGC(Automatic Gain Control) circuit. Experimental results show that the position data is good enough to perform the LPM position control.

  • PDF

Noise Automatic Gain Control to Stabilize Radar Performance (레이다 성능 안정화를 위한 잡음 AGC)

  • Kim, Kwan-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.132-137
    • /
    • 2007
  • The dynamic range of the radar which uses digital signal processors is limited by ADC(Analog-to-Digital Converter). That parameter and ADC loss depend on the noise level of radar receiver. In order to stabilize the performance of radar systems, it is necessary to maintain the noise level constantly. This paper presents the noise AGC(Automatic Gain Control) concept that can keep the noise level constantly and proves that the concept is acceptable through the hardware test and evaluation.

A Design of Variable Attenuator for MMIC using Slot in the Ground Plane (접지면의 슬롯을 이용한 마이크로파 집적회로용 가변 감쇠기의 설계)

  • 김기래
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1109-1114
    • /
    • 2003
  • In this paper, the electric characteristic of the SGPS with slot in the ground plane is similar to the parallel resonant circuit. When the slot length in SGPS is equal to the half wavelength of specific frequency, the characteristic of SGPS represent the large attenuation at the specific frequency. We found out the relation between attenuation and resistor on the slot in SGPS and we designed the variable attenuator for MMIC using the variable resistor. This attenuator can be applied to AGC circuit in transceiver if the PIN diode is used replace for resistor.