• 제목/요약/키워드: AFE(Active Front-End)

검색결과 15건 처리시간 0.019초

Stability and Performance Investigations of Model Predictive Controlled Active-Front-End (AFE) Rectifiers for Energy Storage Systems

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.202-215
    • /
    • 2015
  • This paper investigates the stability and performance of model predictive controlled active-front-end (AFE) rectifiers for energy storage systems, which has been increasingly applied in power distribution sectors and in renewable energy sources to ensure an uninterruptable power supply. The model predictive control (MPC) algorithm utilizes the discrete behavior of power converters to determine appropriate switching states by defining a cost function. The stability of the MPC algorithm is analyzed with the discrete z-domain response and the nonlinear simulation model. The results confirms that the control method of the active-front-end (AFE) rectifier is stable, and that is operates with an infinite gain margin and a very fast dynamic response. Moreover, the performance of the MPC controlled AFE rectifier is verified with a 3.0 kW experimental system. This shows that the MPC controlled AFE rectifier operates with a unity power factor, an acceptable THD (4.0 %) level for the input current and a very low DC voltage ripple. Finally, an efficiency comparison is performed between the MPC and the VOC-based PWM controllers for AFE rectifiers. This comparison demonstrates the effectiveness of the MPC controller.

PI Controlled Active Front End Super-Lift Converter with Ripple Free DC Link for Three Phase Induction Motor Drives

  • Elangovan, P.;Mohanty, Nalin Kant
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.190-204
    • /
    • 2016
  • An active front end (AFE) is required for a three-phase induction motor (IM) fed by a voltage source inverter (VSI), because of the increasing need to derive quality current from the utility end without sacrificing the power factor (PF). This study investigates a proportional-plus-integral (PI) controller based AFE topology that uses a super-lift converter (SLC). The significance of the proposed SLC, which converts rectified AC supply to geometrically proceed ripple-free DC supply, is explained. Variations in several power quality parameters in the intended IM drive for 0% and 100% loading conditions are demonstrated. A simulation is conducted by using MATLAB/Simulink software, and a prototype is built with a field programmable gate array (FPGA) Spartan-6 processor. Simulation results are correlated with the experimental results obtained from a 0.5 HP IM drive prototype with speed feedback and a voltage/frequency (V/f) control strategy. The proposed AFE topology using SLC is suitable for three-phase IM drives, considering the supply end PF, the DC-link voltage and current, the total harmonic distortion (THD) in supply current, and the speed response of IM.

공간벡터변조방식에 의한 AFE정류기의 전류제어 (Current Control for an AFE Rectifier Using Space Vector PWM)

  • 전철환;허재정;윤경국;유희한;김성환
    • 해양환경안전학회지
    • /
    • 제25권4호
    • /
    • pp.498-503
    • /
    • 2019
  • 해양산업분야에서는 극심한 대기오염으로 인하여 전기추진선박에 대한 관심이 높아지고 있다. 이로 인해 선내 전력품질의 저하를 개선하기 위한 연구가 활발히 진행되고 있다. 기존 DFE 정류기의 입력전류 고조파 함유량을 완화시키기 위해 수동형필터, 노치필터, 능동형필터 등을 이용한 다양한 방법이 등장하였다. 그 중에서도 능동필터의 일종인 AFE(Active Front End) 정류장치가 우수한 기술로써 평가받고 있다. 본 논문에서는 공간벡터변조에 의한 AFE정류장치의 전류제어방식을 제안하였다. 기존의 히스테리시스 방식, 삼각파 변조방식 및 공간벡터변조방식을 PSIM을 사용해 시뮬레이션을 수행하여 비교, 분석하였고, 그 결과 공간벡터변조방식이 구조가 간단하고 성능이 가장 우수함을 확인하였다.

Analog Frond-End 내장형 전력선 통신용 CMOS SoC ASIC (Full CMOS PLC SoC ASIC with Integrated AFE)

  • 남철;부영건;박준성;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제46권10호
    • /
    • pp.31-39
    • /
    • 2009
  • 본 논문은 전력선 통신용(PLC) SoC ASIC으로 내장된 Analog Front-end(AFE)를 바탕으로 낮은 소비 전력과 저 가격을 달성할 수 있었으며, CMOS공정으로 구현된 AFE와, 1.8V동작의 Core Logic구동용 LDO, ADC, DAC와 IO pad를 구동하기 위한 LDO로 구성되어 있다. AFE는 Pre-amplifier, Programmable gain Amplifier와 10bit ADC의 수신 단으로 구성되며, 송신 단은 10bit differential DAC, Line Driver로 구성되어 있다. 본 ASIC은 0.18 um 1 Poly 5 Metal CMOS로 구현 되었으며, 동작전압은 3.3 V단일 전원만 사용하였고, 이때 소모 전력은 대기 시에 30mA이며, 동작 시 전력은 300mA으로 에코 디자인 요구를 만족하게 하였다. 본 칩의 Chip size는 $3.686\;{\times}\;2.633\;mm^2$ 이다.

Electric Propulsion Naval Ships with Energy Storage Modules through AFE Converters

  • Kim, So-Yeon;Choe, Sehwa;Ko, Sanggi;Kim, Sungmin;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.402-412
    • /
    • 2014
  • This paper proposes a novel electric propulsion system for naval ships, which consists of Active Front End (AFE) converters directly connected to battery Energy Storage Modules (ESMs). Employing the proposed AFE converters with ESMs in the power systems of naval ships can enhance the reliability and quality of the electric power. Furthermore, the fuel-efficiency of the generator can be improved by a higher loading factor of the generator and its prime movers. The proposed AFE configuration does not require an additional dedicated DC/AC converter for the ESMs. Instead of that, the AFE converter itself can control the DC link voltage and the discharging and/or charging of the ESMs. A control scheme to achieve these control objectives is also presented in this paper. The overall power system, including the generators and electrical loads of a naval ship, is implemented by a small scaled Power Hardware-In-the-Loop (PHIL) simulator. Through this experimental setup, the proposed system configuration and the power control strategies are verified. It is shown that the fuel-efficiency and transient dynamics can be improved in the normal and contingency operation modes.

반도체 변압기용 AFE 정류기의 열해석 연구 (Thermal analysis of the active-front-end rectifier for solid-state-transformer applications)

  • 왕산산;강경필;백주원;김주용;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.435-436
    • /
    • 2017
  • This papaer is study on thermal analysis of the active-front-end(AFE) rectifier for solid-state-transformer(SST) applications. finite element analysis simulation model is combined by switching component model, power diode and heat-sink model. thermal model is calculated by computer program and feedback the result. using simulation result analysis switching loss and compare to thermal diffusion of the heat in the model for steady-state operation.

  • PDF

배전용 반도체 변압기 구현을 위한 SiC MOSFET 기반 전력변환회로 단위모듈 설계에 관한 연구 (Design and Implementation of a Power Conversion Module for Solid State Transformers using SiC MOSFET Devices)

  • 임정우;조영훈
    • 전력전자학회논문지
    • /
    • 제22권2호
    • /
    • pp.109-117
    • /
    • 2017
  • This paper describes the design and implementation of a unit module for a 10 kVA class 13.2 kV/220 V unidirectional solid-state transformer (SST) with silicon-carbide metal-oxide-semiconductor field-effect transistors. The proposed module consists of an active-front-end (AFE) converter to interface 1320 V AC voltage source to 2500 V DC link and an isolated resonant DC-DC converter for 500 V low-voltage DC output. The design approaches of the AFE and the isolated resonant DC-DC converters are addressed. The control structures of the converters are described as well. The experiments for the converters are performed, and results verify that the proposed unit module can be successfully adopted for the entire SST operation.

A Study on Application of Electric Propulsion System using AFE Rectifier for Small Coastal Vessels

  • Jeon, Hyeonmin;Kim, Seongwan;Kim, Jongsu
    • 해양환경안전학회지
    • /
    • 제24권3호
    • /
    • pp.373-380
    • /
    • 2018
  • The small coastal vessel registered in Korea, small coastal vessels with a gross tonnage of 10 tons or less account for 94.6 % and among them, aged vessels over 16 years age indicate 40.6 %. In order to reduce GHG emissions from small coast vessels, discussions are underway to replace aging ships' propulsion units with eco - friendly propulsion facilities, and the electric propulsion ship is emerging as one of the measures. The electric propulsion system using the DFE rectifier, which was applied in the conventional large commercial vessel, was effective in reducing the harmonics and improving the DC output voltage of the DC link stage, but it occupied a large volume and caused an increase in the overall system price. Therefore, in this paper, we propose an electric propulsion system using AFE rectifier with a small volume of system that can be applied to a small coastal vessel. In order to analyze the effectiveness of the overall system, the load profile was applied to obtain accurate and rapid speed tracking performance of the propulsion motor affected by the speed load. In addition, the power factor and total harmonic distortion factor of the voltage and current on the improved power output side are derived through simulation.

신경회로망을 적용한 직류배전시스템의 AFE 정류기 제어에 관한 연구 (Active Front End Rectifier Control of DC Distribution System Using Neural Network)

  • 김성완;전현민;김종수
    • 해양환경안전학회지
    • /
    • 제27권7호
    • /
    • pp.1124-1128
    • /
    • 2021
  • 선박으로부터 발생하는 배출가스에 대한 규제가 강화되고 이를 해결하기위한 대안으로 전기추진시스템의적용이 대형상선에서부터 중·소형선박에 이르기까지 그 사용이 증가되고있다. 전기추진시스템의 효율 향상을 위한 방법으로 발전원의 개선, 배터리·연료전지·태양광 등의 친환경 발전원의 시스템 연계 및 정류기, 전력변환장치, 추진전동기의 개발과 제어방식의 연구를 들 수 있다. 그 중 정류방식에 있어 상천이변압기과 다이오드를 이용하는 방식이 널리 사용되었으나, 직류배전을 이용한 친환경발전원의 계통 연계, 가변속 발전원의 사용, 중·소형 전기추진시스템의 적용을 통해 전력용 반도체 소자를 이용한 AFE정류기에 대한 수요가 증대되고 있다. 이러한 AFE 정류기를 제어하는 방식에 있어 기존의 비례적분제어기가 아닌 신경회로망을 이용한 방식을 본 연구에서는 제안하였다. 기존의 제어기 데이터를 활용하여 Matlab/Simulink를 통해 학습한 신경회로망제어기를 설계하고 PSIM을 통해 설계된 정류시스템에 신경회로망 제어기를 적용하여 부하변동에 따른 직류출력단의 파형과 역률 개선의 유효성을 확인하였다. 이는 공간이 협소한 중소형 친환경 선박의 정류시스템으로써 적용이 가능하다.

A study on the speed control of ship propulsion induction motor using improved AFE rectifier

  • HUR, Jae-Jung
    • 수산해양기술연구
    • /
    • 제56권1호
    • /
    • pp.71-81
    • /
    • 2020
  • This paper proposes a possibility of using active front-end rectifier with the SVPWM method for induction motor speed control, which is applicable to small electric propulsion boats. The proposed method can produce a more precise sinusoidal input current waveform and a higher power factor than conventional methods. Its speed, torque, input current, DC voltage, and load current control performance are similar to or better than those of conventional methods. Through computer simulations using the PSIM program, the validity of the proposed method was verified by comparing and analyzing the characteristics of the conventional methods and the proposed method.