• Title/Summary/Keyword: AE parameters

Search Result 416, Processing Time 0.02 seconds

Quantifying Uncertainty of Calcium Determination in Infant Formula by AAS and ICP-AES (AAS 및 ICP-AES에 의한 조제분유 중 칼슘 함량 분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.701-710
    • /
    • 2004
  • Uncertainty was quantified to evaluate calcium determination result in infant formula with AAS (Atomic Absorption Spectrometry) and ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometry). Uncertainty sources in measurand, such as sample weight, final volume of sample, sample dilution and the instrumental result were identified and used as parameters for combined standard uncertainty based on the GUM (Guide to the expression of uncertainty in measurement) and Draft EURACHEM/CITAC Guide. Uncertainty components of each sources in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, standard material molecular weight, standard solution concentration, standard solution dilution factor, sample dilution factor, calibration curve, recovery, instrumental precision, reproducibility, and stability, Each uncertainty components were evaluated by uncertainty types and included to calculate combined uncertainty. The kinds of uncertainty sources and components in the analytical method by AAS and ICP-AES were same except sample dilution factor for AAS. The analytical results and combined standard uncertainties of calcium content were estimated within the certification range $(367{\pm}20\;mg/100g)$ of CRM (Certified Reference Material) and were not significantly different between method by AAS followed by ashing and method by ICP-AES followed by acid digestion as $359.52{\pm}23.61\;mg/100g\;and\;354.75{\pm}16.16\;mg/100g$, respectively. Identifying uncertainty sources related with precision, repeatability, stability, and maintaining proper instrumental conditions as well as personal proficiency was needed to reduce analytical error.

HYDROLYTIC DEGRADATION OF POSTERIOR RESIN RESTORATIVE MATERIALS (구치부 레진 수복 재료의 가수분해)

  • Yang, Kuy-Ho;Park, Mi-Ran;Choi, Nam-Ki;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.673-682
    • /
    • 2001
  • The use of resin composites has continued to increase over the last several years. In spite of their growing popularity, composites continue to exhibit a number of undesirable characteristics. One of the major deficiencies of composite restorative resins is their inadequate resistance to wear. Of the multitude of factors that have been associated with wear, subsurface degradation within the restoration is considered to be one. The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. This solution with a high concentration of hydroxyl ions is a convenient medium for accelerated degradation of silane coupling and filler particles. The brands studies were Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) and Synergy(Coltene, Swiss). Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters : (a) mass loss(%)-determined from pre-and post-exposed specimen weights : (b) Si loss(ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation $depth({\mu}m)$-measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. Mass loss of Synergy was $1.24{\pm}0.002%$, it was the highest, there was no significant difference among the materials. 2. The degree of degradation layer depth of Synergy was $107.83{\pm}2.52{\mu}m$, it was the highest, there was no significant difference among any other materials than Synergy. 3. There was no difference among the four materials in Si loss. 4. The correlation coefficient between mass loss and degradation depth was relatively high(r=0.06, p<0.05). 5. There was no coefficient correlation between Si loss and mass loss, the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler.

  • PDF

Preparation of $SrTiO_3$ Thin Film by RF Magnetron Sputtering and Its Dielectric Properties (RF 마그네트론 스퍼터링법에 의한 $SrTiO_3$박막제조와 유전특성)

  • Kim, Byeong-Gu;Son, Bong-Gyun;Choe, Seung-Cheol
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.754-762
    • /
    • 1995
  • Strontium titanate(SrTiO$_3$) thin film was prepared on Si substrates by RF magnetron sputtering for a high capacitance density required for the next generation of LSTs. The optimum deposition conditions for SrTiO$_3$thin film were investigated by controlling the deposition parameters. The crystallinity of films and the interface reactions between SrTO$_3$film and Si substrate were characterized by XRD and AES respectively. High quality films were obtained by using the mixed gas of Ar and $O_2$for sputtering. The films were deposited at various bias voltages to obtain the optimum conditions for a high quality file. The best crystallinity was obtained at film thickness of 300nm with the sputtering gas of Ar+20% $O_2$and the bias voltage of 100V. The barrier layer of Pt(100nm)/Ti(50nm) was very effective in avoiding the formation of SiO$_2$layer at the interface between SrTiO$_3$film and Si substrate. The capacitor with Au/SrTiO$_3$/Pt/Ti/SiO$_2$/Si structure was prepared to measure the electric and the dielectric properties. The highest capacitance and the lowest leakage current density were obtained by annealing at $600^{\circ}C$ for 2hrs. The typical specific capacitance was 6.4fF/$\textrm{cm}^2$, the relative dielectric constant was 217, and the leakage current density was about 2.0$\times$10$^{-8}$ A/$\textrm{cm}^2$ at the SrTiO$_3$film with the thickness of 300nm.

  • PDF

Quality characteristics of distilled spirits by different nuruk-derived yeast (누룩 유래 효모의 종류에 따른 증류주의 품질 특성)

  • Lee, Ae-Ran;Kang, Sun-Hee;Kim, Hye-Ryun;Lee, Jang-Eun;Lee, Eun-Jung;Kim, Tae-Wan
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.383-389
    • /
    • 2017
  • This study aimed to select a yeast strain for optimizing the quality of distilled spirits. The brewing and distilling properties of 4 KFRI (Korea Food Research Institute) yeasts (Y88-4, Y98-4, Y172-6, Y192-4) and 2 industry yeasts (C1, C2) were compared. For investigating the possibility of using these strains on an industrial scale, diverse analytical methods were applied to assess parameters associated with distilled spirit quality such as alcohol content, pH, total acidity, and soluble solid content. After 11 days of fermentation, the alcohol strength obtained using six yeast strains reached 13.9-16.4% (v/v), while pH was 3.9-4.0, and total acid was 0.40-0.52%. To compare GC-MSD Volatile flavor components, all the distilled spirit samples were diluted to 20% (v/v) alcohol strength. Seven fusel alcohols, 26 esters, 2 acids, and 3 miscellaneous compounds were detected in the distilled spirits. Y88-4 had the most abundant volatile flavor component and scored the highest overall preference in sensory evaluation. After analyzing the various properties of yeasts, strain Y88-4 was finally selected as the best strain for producing distilled spirits.

Pharmacokinetics of amoxicillin trihydrate in cultured eel Anguilla japonica by single oral and intravenous administrations (Amoxicillin trihydrate의 단독 경구투여 및 정맥투여에 따른 뱀장어, Anguilla japonica 체내 약물동태학적 특성)

  • Jeon, Eun-Ji;Seo, Jeong-Soo;Kim, Jin-Do;Jung, Sung-Hee;Kim, Myoung-Sug;Hwang, Jee-Youn;Park, Myoung-Ae;Jee, Bo-Young;Kim, Jin-Woo;Kim, Yi-Cheong
    • Journal of fish pathology
    • /
    • v.23 no.3
    • /
    • pp.357-367
    • /
    • 2010
  • The pharmacokinetic properties of amoxicillin trihydrate (Amox) were studied after single oral administration and single intravenous injection to cultured eel, Anguilla japonica, respectively (average $220{\pm}10\;g$, $28{\pm}1^{\circ}C$). Plasma samples were taken at 3, 5, 10, 15, 24, 30, 48, 96 and 144 h post-dose. The kinetic profile of absorption, distribution and elimination of Amox in plasma were analyzed fitting to a two-compartment model by WinNonlin program. In oral dosage of 40 and 80 mg/kg body weight, the peak plasma concentrations of Amox, which attained at 3~12 h post-dose, were 3.4 and $3.3\;{\mu}g/ml$, respectively. In intravenous injection with 1 mg/kg, the peak plasma concentrations of Amox, which attained at 9 h post-dose, was $7.2\;{\mu}g/ml$. The following parmeters were calculated for a single oral dosage of 40 and 80 mg/kg body weight, respectively: AUC (the area under the concentration-time curve)= 464 and $667\;{\mu}g{\cdot}h/ml$; $T_{max}$ (time for maximum concentration)= 2.1 and 3.6 h; $C_{max}$ (maximum concentration)= 3.04 and $3.4\;{\mu}g/ml$. Following intravenous injection at 1 mg/kg, this parameters were AUC= $748\;{\mu}g{\cdot}h/ml$; $C_{max}=4.2\;{\mu}g/ml$. The apparent oral bioavailability at 40 and 80 mg/kg were 1.6 and 1.1%, respectively. Despite using the trihydrate form of amoxicillin, the oral bioavailability was low in eel.

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.