• Title/Summary/Keyword: ACI

Search Result 950, Processing Time 0.024 seconds

Experimental study on replaceable precast concrete beam-column connections

  • Seung-Ho Choi;Sang-Hoon Lee;Jae-Hyun Kim;Inwook Heo;Hoseong Jeong;Kang Su Kim
    • Earthquakes and Structures
    • /
    • v.26 no.1
    • /
    • pp.49-58
    • /
    • 2024
  • The purpose of this study was to develop a system capable of restoring the seismic performance of a precast concrete (PC) connection damaged by an earthquake. The developed PC connection consists of a top-and-seat angle, post-tensioning (PT) tendons, and U-shaped steel. The PC beam can be replaced by cutting the PT tendons in the event of damage. In addition, the seismic performance of the developed PC beam-column connection was evaluated experimentally. A PC beam-column connection specimen was fabricated, and a quasistatic cyclic loading test was conducted to a maximum drift ratio of 2.3%. Subsequently, the PC beam was replaced by a new PC beam, and the repaired PC connection was loaded to a maximum drift ratio of 5.1%. The structural performance of the repaired PC connection was then compared with that of the original PC connection. The difference in the load at the drift ratio of 2.3% between the original and the repaired PC specimens was only 0.2%. The residual drift ratio in the repaired PC specimen did not exceed 1.0% at the 2.0 % drift ratio cycles, which satisfies the life safety performance level specified in ACI 374.2R-13. When the developed PC connection system is used, structural performance can be restored by rapidly replacing the damaged elements.

Seismic and Blast Design of Industrial Concrete Structures with Precast Intermediate Shear Wall System (프리캐스트 중간전단벽 시스템이 사용된 콘크리트 산업 시설물의 내진 및 방폭설계)

  • Lee, Won-Jun;Kim, Min-Su;Kim, Seon-hoon;Lee, Deuckhang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.93-101
    • /
    • 2024
  • Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5Sy condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls' non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5Sy for the seismic design.

Evaluation of Emulative Level for Precast Moment Frame Systems with Dry Mechanical Splices by Using Nonlinear Dynamic Analysis (비선형동적해석을 통한 건식 기계적이음을 갖는 프리캐스트 모멘트 골조의 동등성 평가)

  • Kim, Seon-Hoon;Lee, Won Jun;Lee, Deuckhang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.85-92
    • /
    • 2024
  • This study presents code-compliant seismic details by addressing dry mechanical splices for precast concrete (PC) beam-column connections in the ACI 318-19 code. To this end, critical observations of previous test results on precast beam-column connection specimens with the proposed seismic detail are briefly reported in this study, along with a typical reinforced concrete (RC) monolithic connection. On this basis, nonlinear dynamic models were developed to verify seismic responses of the PC emulative moment-resisting frame systems. As the current design code allows only the emulative design approach, this study aims at identifying the seismic performances of PC moment frame systems depending on their emulative levels, for which two extreme cases were intentionally chosen as the non-emulative (unbonded self-centering with marginal energy dissipation) and fully-emulative connection details. Their corresponding hysteresis models were set by using commercial finite element analysis software. According to the current seismic design provisions, a typical five-story building was designed as a target PC building. Subsequently, nonlinear dynamic time history analyses were performed with seven ground motions to investigate the impact of emulation level or hysteresis models (i.e., energy dissipation performance) on system responses between the emulative and non-emulative PC moment frames. The analytical results showed that both the base shear and story drift ratio were substantially reduced in the emulative system compared to that of the non-emulative one, and it indicates the importance of the code-compliant (i.e., emulative) connection details on the seismic performance of the precast building.

The behavior of concrete filled steel tubular columns infilled with high-strength geopolymer recycled aggregate concrete

  • Rajai Z. Al-Rousan;Haneen M. Sawalha
    • Steel and Composite Structures
    • /
    • v.51 no.6
    • /
    • pp.661-678
    • /
    • 2024
  • The utilization of geopolymer recycled aggregate concrete (GRAC) as the infilled core of the concrete-filled steel tubular (CFST) columns provides superior economic and environmental benefits. However, limited research exists within the field of geopolymer recycled aggregate concrete considered a green and sustainable material, in addition to the limitation of the design guidelines to predict the behavior of such an innovative new material combination. Moreover, the behavior of high-strength concrete is different from the normal-strength one, especially when there is another material of high-strength properties, such as the steel tube. This paper aims to investigate the behavior of the axially loaded square high-strength GRACFST columns through the nonlinear finite element analysis (NLFEA). A total of thirty-two specimens were simulated using ABAQUS/Standard software with three main variables: recycled aggregate replacement ratio (0, 30, and 50) %, width-to-thickness ratios (52.0, 32.0, 23.4, and 18.7), and length-to-width ratio (3, 5, 9, and 12). During the analysis, the response in terms of the axial load versus the longitudinal strain was recorded and plotted. In addition, various mechanical properties were calculated and analyzed. In view of the results, it has been demonstrated that the mechanical properties of high-strength GRACFST columns such as ultimate load-bearing capacity, compressive stiffness, energy absorption capacity, and ductility increase with the increase of the steel tube thickness owing to the improvement of the confinement effect of the steel tube. In contrast, the incorporation of the recycled aggregate adversely affected the mentioned properties except the ductility, while the increase of the recycled aggregate replacement ratio improved the column's ductility. Moreover, it has been found that the increase in the length-to-width ratio significantly reduced both the failure strain and the energy absorption capacity. Finally, the obtained NLFEA results of the ultimate load-bearing capacity were compared with the corresponding predicted capacities by numerous codes. It has been concluded that AISC, ACI, and EC give conservative predictions for the ultimate load-bearing capacity since the confinement effect was not considered by these codes.

Shear performance of reinforced concrete beams with rubber as form of fiber from waste tire

  • Ali Serdar Ecemis;Emrah Madenci;Memduh Karalar;Sabry Fayed;Sabry Fayed;Yasin Onuralp Ozkilic
    • Steel and Composite Structures
    • /
    • v.51 no.3
    • /
    • pp.337-349
    • /
    • 2024
  • The growing quantity of tires and building trash piling up in landfills poses a serious threat to the stability of the ecosystem. Researchers are exploring ways to reduce and use such byproducts of the construction industry in an effort to promote greener building practices. Thus, using recycled crumb rubber from scrap tires in concrete manufacturing is important for the industry's long-term viability. This study examines the proportion of waste rubber in fiber form, specifically at weight percentages of 5%, 10%, and 15%. Moreover, the study examines the shear behavior of reinforced concrete beams. A total of twelve RC beam specimens, each sized 100 mm by 150 mm by 1000 mm (w × d × L), were constructed and positioned to the test. Various mixtures were designed with different levels of scrap tire rubber content (0%, 5%, 10%, and 15%) and Stirrup Vol. Ratio (2.10, 2.80, and 3.53) in reinforced concrete beams. The findings indicate that the inclusion of scrap rubber in concrete leads to a decrease in both the mechanical characteristics and weight of the material. This is mostly attributed to the lower strength and stiffness of the rubberized concrete. Furthermore, estimations generated by a variety of design codes were examined alongside the obtained data. In order to make a comparison between the estimates provided by the different codes such as ACI 318-14, CEB-FIB and Iranian national building codes, a calculation was done to determine the ratio of the experimental shear strength to the anticipated shear strength for each code.

Structural Performance of Mortar-filled Sleeve Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading (반복하중을 받는 SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음의 구조성능)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.180-192
    • /
    • 2008
  • The purpose of this research is to evaluate the structural performance of mortar-filled ductile cast iron sleeve splice developed for SD500 high-strength reinforcing bar under cyclic loading. The test variables adopted in this study are the development length of bar, compressive strength of mortar, bar size, sleeve types and others. In this research, it is showed that the mortar-filled sleeve splice for SD500 high-strength bar satisfied the structural performance required in ACI, AIJ code as well as domestic code. Also the results of experimental research presented in this paper provided basic engineering data for developing a reasonable design method of mortar-filled sleeve splice for SD500 high-strength reinforcing bar.

Development of Steel Pipe Splice Sleeve for High Strength Reinforcing Bar(SD500) and Estimation of its Structural Performance under Monotonic Loading (SD500 고강도 철근용 강관 스플라이스 슬리브 철근이음 개발 및 구조성능 평가)

  • Lee, Sang-Ho;Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.169-180
    • /
    • 2007
  • Among several splicing system of reinforcing bar, the grout-filled splice sleeve system has been applied widely. However, as the splice sleeve for high strength rebar as SD500 is not yet made in korea, the development of splice sleeve for high strength reinforcing bar are required as soon as possible. It is the purpose of this study to develop the steel pipe sleeve for high strength rebar as SD500 and estimate its structural performance by monotonic loading test. The experimental variables adopted in this study are the development length of rebars, types of sleeve etc. The results of this study showed that the developed steel pipe splice sleeve system for high strength reinforcing bar as SD500 retained the structural performance required in domestic, ACI and AIJ criteria. And it is considered that the study result presented in this paper can be helpful in developing reasonable design method of steel pipe splice sleeve system for high strength reinforcing bar as SD500.

Agency Costs of Clothing Companies with Famous Brand (유명 의류 상호 기업의 대리인 비용에 관한 연구)

  • Gong, Kyung-Tae
    • Management & Information Systems Review
    • /
    • v.36 no.4
    • /
    • pp.21-32
    • /
    • 2017
  • Motivated by the recent cases of negligent social responsibility as manifested by foreign luxury fashion brands in Korea, this study investigates whether agency costs depend on the sustainability of different types of corporate governance. Agency costs refer either to vertical costs arising from the relationship between stockholders and managers, or to horizontal costs associated with the potential conflicts between majority and minority stockholders. The firms with luxury fashion brand could spend large sums of money on maintenance of magnificent brand image, thereby increasing the agency cost. On the contrary, the firms may hold down wasteful spending to report a gaudily financial achievement. This results in mitigation of the agency cost. Agency costs are measured by the value of the principal component. First, three ratios are constructed: asset turnover, operating expense to sales, and earnings before interest, tax, and depreciation. Then, the scores of each of these ratios for individual firms in the sample are differenced from the ratios for the benchmark firm of S-OIL. S-OIL was designated as the best superior governance model firm for 2013 by CGS. We perform regression analysis of each agency cost index, luxury fashion brand dummy and a set of control variables. The regression results indicate that the agency costs of the firms with luxury fashion brand exceed those of control group in the fashion industry in the part of operating expenses, but the agency cost falls short of those of control group in the part of EBITD, thus the aggregate agency costs are not differential of those of the control group. In sensitivity test, the results are same that the agency cost of the firms are higher than those of the matching control group with PSM(propensity matching method). These results are corroborated by an additional analysis comparing the group of the companies with the best brands with the control group. The results raise doubts about the effectiveness of management of the firms with luxury fashion brand. This study has a limitation that the research has performed only for 2013 and this paper suggests that there is room for improvement in the current research methodology.

  • PDF

Influence of Column Aspect Ratio on the Hysteretic Behavior of Slab-Column Connection (슬래브-기둥 접합부의 이력거동에 대한 기둥 형상비의 영향)

  • Choi, Myung-Shin;Cho, In-Jung;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2007
  • In this investigation, results of laboratory tests on four reinforced concrete flat plate interior connections with elongated rectangular column support which has been used widely in tall residential buildings are presented. The purpose of this study is to evaluate an effect of column aspect ratio (${\beta}_c={c_1}/{c_2}$=side length ratio of column section in the direction of lateral loading $(c_1)$ to the direction of perpendicular to $c_1$) on the hysteretic behavior under earthquake type loading. The aspect ratio of column section was taken as $0.5{\sim}3\;(c_1/c_2=1/2,\;1/1,\;2/1,\;3/1)$ and the column perimeter was held constant at 1200mm in order to achieve nominal vertical shear strength $(V_c)$ uniformly. Other design parameters such as flexural reinforcement ratio $(\rho)$ of the slab and concrete strength$(f_{ck})$ was kept constant as ${\rho}=1.0%$ and $f_{ck}=40MPa$, respectively. Gravity shear load $(V_g)$ was applied by 30 percent of nominal vertical shear strength $(0.3V_o)$ of the specimen. Experimental observations on punching failure pattern, peak lateral-load and story drift ratio at punching failure, stiffness degradation and energy dissipation in the hysteresis loop, and steel and concrete strain distributions near the column support were examined and discussed in accordance with different column aspect ratio. Eccentric shear stress model of ACI 318-05 was evaluated with experimental results. A fraction of transferring moment by shear and flexure in the design code was analyzed based on the test results.

Oocyst Production and immunogenicity of Cryptosporidium baileyi in chickens and mallards (병아리 및 청둥오리에 있어서 닭와포자충의 오오시스트 배설상황과 면역원성)

  • Lee, Jae-Gu;Jang, Byeong-Gwi;Park, Bae-Geun
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.1
    • /
    • pp.45-54
    • /
    • 1995
  • Two-day-old chickens{\;}and{\;}mallards were orally inoculated with one of % doses varying from $2{\;}{\times}{\;}10^2{\;}to{\;}2{\;}{\times}{\;}10^6$ of C. bailevi oocysts per individual. Generally, the more oocysts Inoculated were, the longer the patent periods were, and the more oocysts shedding were. Meanwhile increasing the inoculative dose, the prepatent periods were shortened except that mallards inoculated with $2{\;}{\times}{\;}10^2and{\;}2{\;}{\times}{\;}10^3$ oocysts foiled to produce the oocysts. The more parasites involving oocysts appeared from the chicken in comparison to the mallard. In the chickens challenged with a single dose of $2{\;}{\times}{\;}10^6$ oocysts, a small number of oocysts were detected from feces on days 4-14 after challenge infection (ACI) in all of carrageenan administered groups and in the control groups inoculated with $2{\;}{\times}{\;}10^2{\;}and{\;}2{\;}{\times}{\;}10^3$ oocysts. In the mallards, a few oocysts were also recognized on days 5-15 ACI in all of carrageenan treated groups and in the control groups inoculated with $2{\;}{\times}{\;}10^2,{\;}2{\;}{\times}{\;}10^3{\;}and{\;}2{\;}{\times}{\;}10^4$ oocysts. Just prior to challenge infection, phagocytic activity of peritoneal macrophages (Me) and the number of peripheral Mc in both birds were significantly decreased in the carrageenan treated groups as compared to the control groups. Mild challenge inection in both birds denoted that the immunogenicity of C. bailelli to the birds was very strong, despite MB blocker carrageenan administration.

  • PDF