• Title/Summary/Keyword: ACH(Air Change Rate/Hour)

Search Result 13, Processing Time 0.024 seconds

Night Purge Evaluation Using the RTS-SAREK in Office Buildings (RTS-SAREK을 이용한 사무용 건물의 나이트 퍼지 성능 평가)

  • Shin, Dongshin;Park, Sungkeun;Park, Youngsoo;Park, Jisu;Lee, Jinyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.633-638
    • /
    • 2015
  • This study evaluates the capacity of night purging in office buildings to reduce the cooling load. RTS-SAREK is used to estimate the performance of night purging on the steady state. To overcome steady state RTS program limitations, we added unsteady heat transfer equations. When the ACH (Air Change per Hour) increases, the wall temperature decreases in both the steady and unsteady states. The unsteady heat transfer rate is different from the steady transfer rate, which validates the unsteady calculation. When ACH is low, the heat transfer rate increases continuously with time. When ACH becomes higher, the heat transfer rate increases and decreases with time. When ACH is quite high, there exists a large difference in the heat transfer rate between the steady and unsteady calculations, which emphasizes the importance of the unsteady calculation.

Analysis of Airtightness and Air Leakage of Wooden Houses in Korea

  • Kim, Sejong;Chang, Yoon-Seong;Park, Joo-Saeng;Shim, Kug-Bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.828-835
    • /
    • 2017
  • Airtightness of buildings is one of critical aspects of its energy performance. To build up references of airtightness of wooden houses built in Korea, blower door tests have been carried out in 42 houses since 2006. Causes of air leakage were investigated recently. The average value of air change rate was $3.7h^{-1}$ for light frame house and $5.5h^{-1}$ for post-beam construction at ACH50 (air change per hour at 50 Pa air pressure difference). Foam type insulation was more advantageous in ensuring building airtightness than glass fiber batt. Airtightness of wooden houses which were constructed after 2010 was improved to have less than $1.5h^{-1}$ of ACH50, threshold for application of artificial air change. The average air change rate of CLT (cross laminated timber) houses showed the lowest value, $1.1h^{-1}$, among the tested structures.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.

Development of an Infiltration and Ventilation Model for Predicting Airflow Rates within Buildings (빌딩 내의 공기유동량 예측을 위한 누입 및 환기모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.23 no.2
    • /
    • pp.207-218
    • /
    • 2014
  • A ventilation model was developed for predicting the air change per hour(ACH) in buildings and the airflow rates between zones of a multi-room building. In this model, the important parameters used in the calculation of airflow are wind velocity, wind direction, terrain effect, shielding effect by surrounding buildings, the effect of the window type and insect screening, etc. Also, the resulting set of mass balance equations required for the process of calculation of airflow rates are solved using a Conte-De Boor method. When this model was applied to the building which had been tested by Chandra et al.(1983), the comparison of predicted results by this study with measured results by Chandra et al. indicated that their variations were within -10%~+12%. Also, this model was applied to a building with five zones. As a result, when the wind velocity and direction did not change, terrain characteristics influenced the largest and window types influenced the least on building ventilation among terrain characteristics, local shieldings, and window types. Except for easterly and westerly winds, the ACH increased depending on wind velocity. The wind direction had influence on the airflow rates and directions through openings in building. Thus, this model can be available for predicting the airflow rates within buildings, and the results of this study can be useful for the quantification of airflow that is essential to the research of indoor air quality(temperature, humidity, or contaminant concentration) as well as to the design of building with high energy efficiency.

A CFD Simulation Study on the Isolation Performance of a Isolation Ward (CFD를 이용한 격리병동의 격리성능 검토)

  • Sohn, Deokyoung;Kwon, Soonjung;Choi, Yunho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Purpose: In this study, we performed ventilation simulations for a standard isolation ward including three intensive care rooms, one anteroom(buffer room), and its recommended ventilation equipments. The purpose of this study is to predict outflow of pathogenic bacteria from patient breath to verify the reliability and the safety of the isolation ward. Methods: We suppose three scenarios of the movement of medical staff. The leakage of patient's breath to out of the ward is predicted in these scenarios using CFD simulations. Results: The patient's breath leakage rate to out of the ward in scenario 1 according to room air changes per hour(ACH : 6 and 12) is predicted to be 0.000057% and 0.00002%, respectively. The patient's breath leakage rate to out of the ward in scenario 2 according to room air changes(ACH : 6 and 12) is predicted to be 0.00063% and 0.00019%, respectively. The patient's breath leakage rate to out of the ward in scenario 3, which is the worst case(6 room air changes) is predicted to be 0.1%. Implications: Through the ventilation simulation like that in this study, the reliability and the safety on isolation performance of various plan of isolation ward are predicted quantitatively.

Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools (초·중·고등학교의 이산화탄소 농도 및 환기량 평가)

  • Choe, Youngtae;Heo, Jung;Park, Jinhyeon;Kim, Eunchae;Ryu, Hyoensu;Kim, Dong Jun;Cho, Mansu;Lee, Chaekwan;Lee, Jongdae;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.3
    • /
    • pp.344-352
    • /
    • 2020
  • Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction (고기밀 고단열 주택의 기밀성능에 관한 실험적 연구)

  • Shin, U-Cheul;Yoon, Jong-Ho;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

Analysis on Ventilation Performance of Natural Ventilation Systems in Multi-Family Housing Using Blower Door Test (Blower Door Test를 이용한 공동주택 자연환기시스템의 환기성능 분석)

  • Kim, Min Seok;Auh, Jin Sun;Hong, Goopyo;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.129-134
    • /
    • 2016
  • Today, natural ventilation systems are widely applied in multi-family housing. However, studies using the wind data trend line of the blower door test are insufficient. Purpose: Through this study, we will propose a computational method about ventilation performance of natural ventilation systems by conducting blower door test. Method: First, we sealed the gaps between the main systems including the natural ventilation system and conducted the blower door test. Next, the natural ventilation system was opened, the blower door test was conducted, and the difference in air flow rate between when closed and when opened was checked. Blower door test was carried out with a pressure difference of 50 Pa. Result: Therefore, the ventilation performance of the natural ventilation system was checked by drawing a trend line using the data to calculate the air flow rate at 2 Pa of the natural ventilation equipment standard pressure difference.

실내사무환경에서의 환경성담배연기(ETS) 중 지표물질에 관한 연구

  • Ha, Gwon-Cheol;Baek, Nam-Won;Park, Dong-Uk;Yun, Chung-Sik
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.154-159
    • /
    • 2005
  • The markers for Environmental Tobacco Smoke(ETS) a.e necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment. The purpose of this research is to evaluate Indoor environment using the concentration of ETS and the correlations between markers(RSP, nicotine, 3-EP) and environmental conditions(smoking density, ventilation rate). The mean ACH(air change per hour) in smoking rooms showed non-compliance with ASHRAE standard value. The concentrations of RSP, 3-EP, nicotine showed log-normal distributions, and became different statistically depending on smoking condition(p<0.01). The geometric mean concentration of RSP in smoking room was 441.7 ${\mu}g/m^3$ that is far exceeded environmental standard(150 ${\mu}g/m^3$). The correlation coefficients between RSP and SI, 3-EP and SI, and Nicotine and SI were 0.67, 0.84, 0.74 respectively. The correlation coefficient between nicotine and 3-EP, Nicotine and RSP, and RSP and 3-EP were 0.76, 0.78, 0.57 respectively.

  • PDF

A Study of the Indoor Air Quality Improvement for Large Scale Assembly Facilities (건축물의 대공간 집회시설의 실내공기질 개선방안에 관한 연구)

  • Lim, Tae-Sub;Kang, Seung-Mo
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.4
    • /
    • pp.183-190
    • /
    • 2011
  • Lately majority of churches have preferred to enlarge their worship area to both horizontal and vertical axis. According to expand their area which brings more devotees to the limited service area. Transform from a small church into a large church is no longer unprecedented issue in South Korea. As the size of church getting bigger, many unexpected issues become matters. One of the significant problem is that the number of people have experienced either fall a sleep or feel a doziness during their service period. Due to the limited condition for the specific building type such as religion facility(church), IAQ improvements is seriously concerned. Therefore, we are going to examine by using simulation tool, CF, a difference of ventilation efficiency about the location and number of windows, and find the best way of the ventilation efficiency in a multi-stories type church by changing the exhaust pipes location and size. Furthermore, in this thesis, by changing a ceiling height from the existing building to confirm that $CO_2$ have been satisfied for both the ventilation efficiency and IAQ.