• Title/Summary/Keyword: AC surface discharge

Search Result 154, Processing Time 0.025 seconds

Studies on Characteristics of a Superposition Type of Ozonizer with DC and AC Discharges (직.교류 중첩방전을 이용한 오존발생 특성 연구)

  • Hong, Hong-Sung;Wee, Sang-Bong;Ahn, Hee-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1626-1628
    • /
    • 2001
  • 본 연구는 AC 전원을 인가하여 좁은 전 극간격에서 고수율을 얻을 수 있는 연면방전방식 (Surface Discharge type)과 DC 전원을 인가하여 넓은 전극간격에서 저수율을 가지는 DC방전방식(DC Discharge type)을 중첩방전 할 수 있도록 중첩방전관을 설계 제작하여 각각 독립적인 방전방식을 적용하였을 때의 방전전압, 방전전류, 방전전력 및 오존생성농도를 실험적으로 조사하고, 두 방전방식을 동일공간에 중첩방전하여, 위 실험을 반복하고 중첩방전이 동일방전공간에 투입에너지 밀도를 높임으로써 방전특성 및 오존생성 특성을 비교 분석하였다.

  • PDF

The dependence of the electrical characteristics of MgO on temperature in an AC PDP

  • Ha, Chang-Hoon;Jeong, Dong-Chul;Kim, Joong-Kyun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.714-716
    • /
    • 2005
  • We studied the dependence of the electrical characteristics of MgO protecting layer on temperature in an AC PDP cell. Careful measurements of the surface resistance of MgO were performed for the temperature range from room temperature to $100^{\circ}C$ with and without the VUV illumination. Experimental results show that the resistivity is affected by not only the temperature but also VUV irradiation. The measurement of wall charge distribution and the address discharge delay time as to the temperature show that the resistivity change of MgO may affect the wall voltage and consequently the discharge delay time.

  • PDF

Design of Erase Waveform for Stabilizing Reset Discharge in Mid-gap AC Plasma Display Panels (중간간격을 갖는 교류형 플라즈마 디스플레이 표시기의 소거파형 연구)

  • Yoon, Su-Han;Seo, Jeong-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.993-998
    • /
    • 2011
  • In this paper we suggest new criteria for the classification of the electrode gap between common and scan electrodes. The electrode gap is categorized as a short, middle, and long gap according to the criteria. Among these structures, we focus on the erase waveform of a mid-gap structure. we report an unstable discharge arising from the erase ramp period in a mid-gap structure. Based on the Vt close curve, we analyze the unstable discharge at various conditions. Our analysis reveals that the unstable discharge is ignited between surface electrodes and caused by un-erased wall charges accumulated on the outer edges of electrodes. By reducing the voltage level of the last sustain pulse, the problem is solved.

Influence of Sustain Pulse-width on Electrical Characteristics and Luminous Efficiency in Surface Discharge of AC-PDP

  • Jeong, Yong-Whan;Jeoung, Jin-Man;Choi, Eun-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.276-279
    • /
    • 2005
  • Influences of sustain pulse-width on electrical characteristics and luminous efficiency are experimentally investigated for surface discharge of AC-PDP. A square pulse with variable duty ratio and fixed rising time of 300 ns has been used in the experiment. It is found that the memory coefficient is significantly increased at the critical pulse-width. And the wall charges and wall voltages as well as capacitances are experimentally measured by Q- V analysis method along with the voltage margin relation, in terms of the sustain pulse-width in the range of $1{\mu}s$ to $5{\mu}s$ under driving frequency of 10 kHz to 180 kHz. And the luminous efficiency is also experimentally investigated in above range of sustain pulse-width with driving frequency of 10 kHz to 180 kHz. It is noted that the luminous efficiency for 10 kHz and 180 kHz are 1.29 1m/W and 0.68 1m/W respectively, since the power consumption for 10 kHz is much less than that for 180 kHz. It has been concluded that the optimal sustain pulse-width is in the range of $2.5 {\~}4.5{\mu}s$ under driving frequency range of 10 kHz and 60 kHz, and in the range of $1.5 {\~} 2.5{\mu}s$ under driving frequency range of 120 kHz and 180 kHz based on observation of memory coefficient, and wall voltage as well as luminous efficiency.

A Study on the Glow Discharge Characteristics of MgO thin film prepared by Unbalanced Magnetron Sputtering (불평형 마그네트론 스파터링에 의해 형성된 MgO 박막의 글로우 방전특성에 관한 연구)

  • Kim, Young-Kee;Park, Jung-Tae;Ko, Kwang-Sic;Kim, Gyu-Seup;Park, Chung-Hoo;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2236-2238
    • /
    • 1999
  • This paper deals with the surface glow discharge characteristics and some physical properties of MgO thin films prepared by RF unbalanced magnetron sputtering(UBMS) in surface discharge type AC PDP. The minimum discharge voltage is obtained for the sample of substrate holder bias voltage -10V. The main factors that improves the discharge characteristics by applied bias voltage is considered to be due to the morphology changes or crystal structure of the MgO thin film by ion bombardment during deposition process Moreover, the anti-sputtering characteristics of MgO thin film by UBMS is more excellent than that of balanced magnetron sputtering(BMS) and E-beam evaporation method.

  • PDF

Optimization of Optical Transmittance in Plasma Display Panel (PDP의 광투과특성 최적화에 관한 연구)

  • 최규남
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.78-84
    • /
    • 1998
  • Refractive index was matched using the inhomogeneous dielectric layers to enhance the optical transmittance of surface discharge type AC PDP. The transmittance of upper panel which had two index-matched inhomogeneous dielectric layers was measured as 85%, and this result is regarded as 15% better transmittance than that of conventional structure, which is about 70%.

  • PDF

An Energy Recovery Circuit for AC Plasma Display Panel with Serially Coupled Load Capacitance-SER1

  • Yang, Jin-Ho;Whang, Ki-Woong;Kang, Kyoung-Ho;Kim, Young-Sang;Kim, Hee-Hwan;Park, Chang-Bae
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.63-67
    • /
    • 2001
  • The switching power loss due to the panel capacitance during sustain period in AC PDP driving system can be minimized by using the energy recovery circuits. We proposed a new energy recovery circuit, SER1 (Seoul national univ. Energy Recovery circuit 1st). The experimental results of its application to a 42-inch surface discharge type AC PDP showed superior performance of SER1 in energy recovery efficiency and low distortion voltage waveform. Energy recovery efficiency of SER1 was measured up to 92.3 %, and the power dissipation during the sustain period was reduced by 15.2 W in 2000 pulse/frame compared with serial LC resonance energy recovery circuit.

  • PDF

A Study on Improvement of the Performance of Pulsed AC Ion Bar (2) (바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (2))

  • Lee, Dong Hoon;Choi, Dong Soo;Kim, Sang Min;Park, Jin Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.40-45
    • /
    • 2014
  • In display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods. The most general type of ionization is called, "corona discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. continually "A study on the improvement of the performance of pulsed AC ion bar(1)", we have studied consecutive study to improve the current issue via appling "partition wall" at air nozzle surrounding. The results were that the charge decay time and the ion balance was maintained the satisfied range that was within 5 second and ${\pm}50$ V for a 180 days period of time. In additions, the contamination status on the electrode surface was investigated for a 180 days. The little particles was deposited on the electrode surface.

The Measurement of the Wall Charge on the Three Electrodes in the Addressing Period of ac PDP (AC PDP의 addressing 시 3전극 상에서의 벽전하량 계측)

  • Lee, Ki-Bum;Kim, Dong-Hyun;Kang, Dong-Sik;Park, Cha-Soo;Cho, Chung-Soo;Park, Chung-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.103-107
    • /
    • 2000
  • The relationships between driving voltage and the wall charge distribution in the address period of surface discharge type AC Plasma Display Panel have been investigated. The quantity of wall charge on each electrode are detected simultaneously from the electrode current after applying only one addressing discharge pulse. The wall charge Qy on the scan electrode Y is nearly the sum of Qx on the address electrode X and Qz on the sustain electrode Z. The Qy increased with the driving voltage regardless of the kind of electrode, whereas the address time Td decreased, Qz and Qy are increased considerably with the blocking voltage Vz, whereas Qx is decreased. The increase rate of Qx, Qy and Qz for increase in Vz was $-13{\times}10^{-2}$ (pc/Vz), and $60{\times}10^{-2}$ (pc/Vz) and $70{\times}10^{-2}$(pc/Vz), respectively.

  • PDF

Wall Charge Distribution In the Address Period of AC Plasma Display Panel (AC PDP의 addressing 기간중의 벽전하 분포에 관한 연구)

  • Lee, Ki-Bum;Kim, Dong-Hyun;Kang, Dong-Sik;Park, Chung-Hoo;Cho, Chung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1830-1833
    • /
    • 2000
  • The relationships between driving voltage and the wall charge distribution in the address period of surface discharge type AC Plasma Display Panel have been investigated. The quantity of wall charge on each electrode are detected simultaneously from the electrode current after applying only one addressing discharge pulse. The wall charge Qy on the scan electrode Y is nearly the sum of Qx on the address electrode X and Qz on the sustain electrode 2. The Qy increased with the driving voltage regardless of the kind of electrode, whereas the address time Td decreased, Qz and Qy are increased considerably with the blocking voltage Vz, whereas Qx is decreased. The increase rate of Qx, Qy and Qz for increase in Vz was $-13{\times}10^{-2}$(pc/Vz), and $60{\times}10^{-2}$(pc/Vz) and $70{\times}10^{-2}$(pc/Vz), respectively.

  • PDF