• Title/Summary/Keyword: AC impedance spectroscopy

Search Result 104, Processing Time 0.027 seconds

A Review of Ac-impedance Models for the Analysis of the Oxygen Reduction Reaction on the Porous Cathode Electrode for Solid Oxide Fuel Cell

  • Kim, Ju-Sik;Pyun, Su-Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.106-114
    • /
    • 2005
  • This article covers the theoretical ac-impedance models for the analysis of oxygen reduction on the porous cathode electrode f3r solid oxide fuel cell (SOFC). Firstly, ac-impedance models were explained on the basis of the mechanism of oxygen reduction, which were classified into the rate-determining steps; (i) adsorption of oxygen atom on the electrode surface, (ii) diffusion of adsorbed oxygen atom along the electrode surface towards the three-phase (electrode/electrolyte/gas) boundaries, (iii) surface diffusion of adsorbed oxygen atom m ixed with the adsorption reaction of oxygen atom on the electrode surface and (iv) diffusion of oxygen vacancy through the electrode coupled with the charge transfer reaction at the electrode/gas interface. In each section for ac-impedance model, the representative impedance plots and the interpretation of important parameters attributed to the oxygen reduction reaction were explained. Finally, we discussed in detail the applications of the proposed theoretical ac-impedance models to the real electrode of SOFC system.

Impedance Spectroscopy of ${\pi}$-Conjugated Organic Materials

  • Kim, Seong-Hyun;Chu, Hye-Yong;Zyung, Taeh-Young;Yang, Yong-Suk
    • ETRI Journal
    • /
    • v.26 no.2
    • /
    • pp.161-166
    • /
    • 2004
  • AC electrical properties of organic light-emitting diodes with poly(2-methoxy-5-(2'-ethyl-hexyloxy)-1,4-phenylenevinylene) (MEH-PPV), poly[2,5-bia(dimethyloctylsilyl)-1,4-phenylenevinylene] (BDMOS-PPV), and tris-(8-hydroxyquinolate)-aluminum $(AlQ_3)$ as light-emitting materials are studied. The frequency-dependent real and imaginary parts of impedance were fitted using an equivalent circuit. We found that the conduction mechanism is a space-charge limited current with exponential trap distribution.

  • PDF

Characterizing the ac-dc-ac Degradation of Aircraft and Vehicle Organic Coatings using Embedded Electrodes

  • Bierwagen, Gordon P.;Allahar, Kerry N.;Su, Quan;Victoria, Johnston-Gelling
    • Corrosion Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.261-268
    • /
    • 2007
  • Embedded sensors were used as an in-situcorrosion-sensing device for aircraft and vehicular structures protected by organic coatings. Results are presented changes associated with a standard Airforce aircraft coating and a standard Army vehicle coating were monitored by embedded sensors. These coatings consisted of a polyurethane topcoat and an epoxy primer, however are formulated to provide different characteristics. The ac-dc-ac testing method was used to accelerate the degradation of these coatings while being immersed in a NaCl medium. Electrochemical impedance spectroscopy and electrochemical noise measurement experiments were used to monitor the induced changes. A comparison of the results between coatings subjected to the ac-dc-ac exposure and coatings subjected to only constant immersion in the NaCl medium is presented. The results were used to demonstrate the effectiveness of the ac-dc-ac method at accelerating the degradation of an organic coating without observably changing the normal mechanism of degradation. The data highlights the different features of the coating systems and tracks them while the coating is being degraded. The aircraft coating was characterized by a high-resistant topcoat that can mask corrosion/primer degradation at the primer/substrate interface whereas the vehicle coating was characterized by a low-resistant topcoat with an effective corrosion inhibiting primer. Details of the ac-dc-ac degradation were evaluated by using an equivalent circuit to help interpret the electrochemical impedance data.

Relative Comparison of Cathode Polarizations in Solid Oxide Fuel Cells Using the Spreading Concept in AC 2 Point Impedance Spectroscopy

  • Lee, Byung-Kook;Kim, Eui-Hyun;Hwang, Jin-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • A modified two-point impedance spectroscopy technique exploits the geometric constriction between an electrolyte and a cathode with an emphasis on semispherical-shaped electrolytes. The spatial limitation in the electrolyte/electrode interface leads to local amplification of the electrochemical reaction occurring in the corresponding electrolyte/electrode region. The modified impedance spectroscopy was applied to electrical monitoring of a YSZ ($Y_2O_3$-stabilized $ZrO_2$)/SSC ($Sm_{0.5}Sr_{0.5}CoO_3$) system. The resolved bulk and interfacial component was numerically analyzed in combination with an equivalent circuit model. The effectiveness of the "spreading resistance" concept is validated by analysis of the electrode polarization in the cathode materials of solid oxide fuel cells.

Study on Evaluation of Degrease Performance on the Interface between Oil and Alloy (탈지 정도에 대한 방청유-금속 계면의 영향성 평가)

  • Choi, Wonyoung;Kim, Moonsu;Yoo, Hyeonseok;Song, Yeongyun;Jeong, Yong-Gyun;Choi, Jinsub
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.371-379
    • /
    • 2021
  • The use of anti-corrosive oil (AC) is inevitable for production of industrial steels to prevent corrosion. The AC is degreased before application of steels, which crucially effects on final products, such as automobile, electricity etc. However, qualitative/quantitative evaluation of degreasing performance are steal insufficient. In this study, degreasing performance of anti-corrosive oil on steel have been studied through X-ray photon spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). Commercial automotive steels (AMS) are coated with 4 different anti-corrosive oils (namely AC1-AC4). In XPS, intensity of C1s peak remained after degreasing indirectly indicates incomplete degreasing. Thus, higher C1s peak intensity means less effective degreasing by degreasing agent. peak intensity of C1s peak shows opposite tendency of peak intensity of O1s. We found that EIS analysis is not applicable to mild steel (such as AMS1) due to corrosion during measurement. However, alloy steel can be fully analyzed by EIS and XPS depth profile.

Impedance Spectroscopy Study of TiO$_2$ added SnO$_2$ (TiO$_2$가 첨가된 SnO$_2$의 Impedance Spectroscopy에대한 연구)

  • 최우성;박춘배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.277-279
    • /
    • 1996
  • A.C. and D.C. characteristic of TiO$_2$ added SnO$_2$ are investigated to study the electrical properties. The electrical inductivity increases as TiO$_2$content increase. The doer effect of TiO$_2$ is crucial role for the increase of electrical conductivity. The frequency-dependent ac inductivity increases with the increase of TiO$_2$ contents at low frequency region. However, at high frequency region, the difference of ac conductivity is very small. Impedance spectrums are consist of the one semicircle. Therefore, the sizes of semicircle decreases with increasing the TiO$_2$ contents.

  • PDF

Monitoring of Degradation Process of Commercial ME Tapes under High Humidity Environment by AC Impedance Techniques

  • Take, Seisho;Shimanuki, Akiko;Itoi, Yasuhiko;Okuyama, Masaru
    • Corrosion Science and Technology
    • /
    • v.3 no.5
    • /
    • pp.194-197
    • /
    • 2004
  • The corrosion resistance of several kind of ME (Metal Evaporated) tape has been investigated both in mild sulfuric acid solution and NaCl solution by electrochemical impedance spectroscopy. It was found that the degradation of ME tapes was accelerated with increasing the concentration of sulfuric acid. There was no significant change in corrosion resistance when the concentration of NaCl was under 3.5 wt%. However, the impedance value decreased when the concentration of NaCl was up to 10 wt%. The degradation of backside of ME tapes was also investigated by AC impedance measurements. The results showed that the impedance behavior of backside plastic film changed with the concentration of sulfuric acid even at the beginning of immersion, implying the changing of the permeability for the backside of ME tapes. It was also found that the corrosion resistance of DVC (Digital Video Cassette) ME tape was better that that of Hi-8mm ME tapes in sulfuric acid solutions. Also, the backside of DVC ME tape showed better water resistance than that of Hi8 ME tapes.

Characterization of a LSCF/GDC Cathode Composite in Solid Oxide Fuel Cells Using Impedance Spectroscopy

  • Hwang, Jin-Ha;Lee, Byung-Kook
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.12 s.283
    • /
    • pp.793-799
    • /
    • 2005
  • A composite cathode of LSCF$(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3)\;and\;GDC\; (Gd_2O_3-doped\;CeO_2:Ce_{0.9}Gd_{0.1}O_{1.95_})$ was characterized in terms of an electrode response, using a point contact in an Yttria-Stabilized Zirconia (YSZ) electrolyte incorporated into AC two-point impedance spectroscopy. The point-contacted configuration amplifies the responses occurring near the YSZ/cathode interface through the aligned point contact on the planar LSCF/GDC electrode. The point contact interface increases the bulk resistance allowing the estimation of the point contact geometry and resolving the electrode-related responses. The resultant impedance spectra are analyzed through an equivalent circuit model constructed by resistors and constant phase elements. The bulk responses can be resolved from the electrode-related portions in terms of spreading resistance. The electrode-related polarizations are measured in terms of temperature and oxygen partial pressure. The modified impedance spectroscopy is discussed in terms of methodology and analytical aspects, toward resolving the electrode-polarization issues in solid oxide fuel cells.

AC dielectric response of poly(p-phenylenevinylene) light emitting devices (주파수 의존성에 따른 고분자 LED의 유전 분산 거동에 관한 연구)

  • 이철의;김세헌;장재원;김상우
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.149-152
    • /
    • 2000
  • AC impedance measurements on poly-p-phenylenevinylene (PPV) LEDs in the frequency range between 10 Hz and 10$\^$6/ Hz were carried out. The complex-plane impedance spectra indicate that PPV devices can be represented by equivalent circuits that corresponds to the bulk and interfacial regions at high and low frequencies, respectively. As a result of complex impedance analysis through the separation of bulk and interfacial region impedances, increase of forward bias in Al/PPV/ITO devices gave rise to relative decrease of the interfacial region impedance. Above the electric field of 10$\^$6/ V/cm the PPV device showed a space charge limited current (SCLC) conduction. The dependence of the transport mechanism and dielectric properties on the applied bias voltage is discussed.

  • PDF

Impedance spectroscopy for lifetime analysis of OLED

  • Yoon, Chul-Oh;Kim, Hyun-Chul;Yi, Seok-Kyung;Kong, Ung-Gul;Lee, Nam-Heon;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.137-140
    • /
    • 2002
  • The frequency response analysis of complex impedance spectra using small perturbation ac impedance spectroscopy is an informative method of OLED performance characterization and lifetime analysis. Using simple RC equivalent circuit mode,l macroscopic nonliniear transport properties of semiconductive emission/transport layers can be analyzed and parameterized. We present the bias voltage dependence and aging effect in impedance spectra measured from an ITO/CuPC/TPD/$Alq_3$/LiF/Al OLED device, and discuss possible failure mechanism based on impedance model parameters.

  • PDF