• 제목/요약/키워드: AC System

검색결과 2,745건 처리시간 0.026초

Frequency Stabilization Method for Grid Integration of Large-scale Centralized Wind Farms via VSC-HVDC Technology

  • Peng, Yanjian;Li, Yong;Liu, Fang;Xu, Zhiwei;Cao, Yijia
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.547-557
    • /
    • 2018
  • This work proposes a control method of frequency stabilization for grid integration of large-scale wind farms via the voltage source converter-based high-voltage direct current (VSC-HVDC) technology. First, the topology of grid integration of a large-scale wind farm via the VSC-HVDC link is provided, and simple control strategies for wind turbines, wind farm side VSC (WFVSC), and grid side VSC are presented. Second, a mathematical model between the phase angle of WFVSC and the frequency of the wind farm is established. The control principle of the large-scale wind power integrated system is analyzed in theory in accordance with the mathematical model. Third, frequency and AC voltage controllers of WFVSC are designed based on the mathematical model of the relationships between the phase angle of WFVSC and the frequency of the wind farm, and between the modulation index of WFVSC and the voltage of the wind farm. Corresponding controller structures are established by deriving a transfer function, and an optimization method for selecting the parameters of the frequency controller is presented. Finally, a case study is performed under different operating conditions by using the DIgSILENT/PowerFactory software. Results show that the proposed control method has good performance in the frequency stabilization of the large-scale wind power integrated system via the VSC-HVDC technology.

직물류 유물의 전시 및 보관환경 실태조사-대학박물관을 중심으로- (A Study on the Actual Conditions of Museum Environment for Old Textile Collections -Focused on university Museums-)

  • 배순화
    • 복식
    • /
    • 제34권
    • /
    • pp.109-120
    • /
    • 1997
  • The conservation of collections in muse-ums is an important aspect for our her-itage. The control of museum environment is a vital factor in the preservation of cool-lections. Inappropriate or fluctuating envi-ronmental conditions can cause irreparable damage to works of arts. In this research we investigated the ac-tual conditions of museum environment for old testiles using questionnaire and mea-sured dye fasing of old textiles on exhibi-tion for 2 months in a university museum the major results are as follows: 1. The control of temperature and rela-tive humidity is a vital factors I the preservation of old textiles in museum generally acceptable temperature and rel-ative humidity standards for old textiles are 18-23$^{\circ}C$ and 50-65% R. H and light level for textiles on exhibition should be limited to 30-50 lux. 2, In university museums the limate control system in exhibition and storage area is in an early stage. Therefore to minimize the deterioration of old textiles the best method of controlling the envi-ronment is to have centralized climate control system in sorage area as well as in display area. 3. Conservator is needed to maintain collections scientifically. Only professional conservator by combining scientific tech-nical and artistic training has the exper-tise needed to maintain the physical in-tegrity of old textiles. In order to solve the inferior environment of museums the staff should recognize the importance of the condition of exhibition and storage. 4. Old textiles are susceptible to damage by light and associated heat. Dyed textiles which have been exhibited under the light without any UV filter were faded notice-ably within two months of exhibition. Light levels for textiles on exhibition should be limited to 30-50 lux. It is de-sirable to use special light source that can absorb UV. and UV filter is also recom-mended to reduce photodegradation of old textiles.

  • PDF

Exit Beam Dose Profile을 이용한 3차원 보상체의 성능확인 (The Verification of Dosimetric Characteristics of the 3-D Compensator with the Exit Beam Dose Profile)

  • 이상훈;이병용;권수일;김종훈;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.3-17
    • /
    • 1996
  • 방사선 치료분야에서 선량 보상체가 널리 이용되고 있으나, 그 보상효과에 대한 확실한 검증 방법은 알려진 바가 거의 없다. 본 연구에서는 Missing Tissue 뿐 아니라, Internal Tissue Inhomogeneity 까지 고려한 3차원 보상체를 제작하고, Exit Beam Dose Profile의 측정값과 본 연구에서 고안한 방법으로 기대값을 구해 비교함으로써 보상체의 성능을 평가하고자 하였다. 환자정보는 CT Simulator를 사용하여 얻었고, 보상체 정보는 Render Plan 3-D Planning System을 통해 얻었다. Computer Controlled Milling Machine으로 알루미늄 보상체를 제작해서 보상체가 있는 경우와 없는 경우의 선량 프로파일을 측정하여 비교하였다. 측정은 폴리스티렌 팬톰 사이에 필름을 삽입하여 팬톰 내에서의 실제 선량 분포를 구하고, 필름 카셋트를 이용해서 Exit Beam Dose Profile 을 동시에 얻었다. Oblique Beam, Parallel Opposing Beam, Inhomogeneus Human Phantom에 대해 제작된 보상체가 각각 선량보상 효과가 잘 나타남을 볼 수 있었고, 이 연구에서의 성능확인 방법을 통해 보상체의 성능을 확인할 수 있었다.

  • PDF

원유의 위생학적 유질변동에 관한 연구 (세균수와 체세포수에 기초한 원유가격제 실시에 따라) (Studies on Variation of Hygienic Quality for Raw Milk (According to Milk Pricing Structure based on Total Bacterial Count & Somatic Cell Count))

  • 이성모;황현순;손봉환;윤화중
    • 한국동물위생학회지
    • /
    • 제17권3호
    • /
    • pp.208-226
    • /
    • 1994
  • From January to December 1993, 3,385 bulk milk samples were collected from 293 herds in Inchon area. Standard plate counts(SPC) and somatic cell counts(SCC) were performed by the method of milk collection, the situation of raising management and monthly. The results obtained are summarized as follows : 1, Annual average SPC and SCC were respectively 638,000 cfu /mm and 647,000 cells /mm. SPC showed an abrupt decrease from January-1,088,000 cfu /mm to December-279,000 cfu /mm, but SCC showed a slow change from January-1,017,000 cells /mm to December -673,000 cells /mm 2. Variation on milk quality(annual average SPC) was shown a wide difference between everyday collection-575,000 cfu /mm and every other day collection-1,243,000 cfu /mm ac-cording to frequency of milk collection from dairy farms. However, there was a little difference In SCC. 3. In the raising scale, average SPC were the lowest in 16~25mi1king cows, and average SCC were the lowest in above 25milking cows. 4. According to types of milking machine, average SPC and SCC of dairy farms that are equipped with pipeline system were respectively 361,000 cfu /mm and 591,000 cells /mm. Those of dairy farms with bucket system were 549,000 cfu /me and 559,000 cells /mm. 5. In the types of management, average SPC an SCC of dairy farms with hired herdsman were 288,000 cfu /mm and 559,000 cells /mm. Those of dairy farms with self-management were 526,000 cfu /mm and 568,000 cells /mm.

  • PDF

Hydraulic Behaviors of KSTAR PF Coils in Operation

  • Park, S.H.;Chu, Y.;Kim, Y.O.;Yonekawa, H.;Chang, Y.B.;Woo, I.S.;Lee, H.J.;Park, K.R.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.24-27
    • /
    • 2012
  • The superconducting coil system is one of the most important components in Korea Superconducting Tokamak Advanced Research (KSTAR), which has been operated since 2008. $Nb_3Sn$ and NbTi superconductors are being used for cable-in-conduit conductors (CICCs) of the KSTAR toroidal field (TF) and poloidal field (PF) coils. The CICCs are cooled by forced-flow supercritical helium about 4.5 K. The temperature, pressure and mass flow rate of the supercritical helium in the CICCs are interacting with each other during the operation of the coils. The complicate behaviors of the supercritical helium have an effect on the operation and the efficiency of the helium refrigeration system (HRS) by means of, for instance, pressure drop. The hydraulic characteristics of the supercritical helium have been monitored while the TF coils have stably achieved the full current of 35 kA. In other hands, the PF coils have been operated with various pulsed or bipolar mode, so the drastic changes happen in view of hydraulics. The heat load including AC loss on the coils has been analyzed according to the measurement. These activities are important to estimate the temperature margin in various PF operation conditions. In this paper, the latest hydraulic behaviors of PF coils during KSTAR operation are presented.

Characterization of Two Algal Lytic Bacteria Associated with Management of the Cyanobacterium Anabaena flos-aquae

  • Kim, Jeong-Dong;Lee, Choul-Gyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권5호
    • /
    • pp.382-390
    • /
    • 2006
  • Various microorganisms were isolated from the surface waters and sediments of eutrophic lakes and reservoirs in Korea to enable an investigation of bacteria having algal lytic activities against Anabaena flos-aquae when water blooming occurs and to study enzyme profiles of algal lytic bacteria. Two bacterial strains, AFK-07 and AFK-13, were cultured, characterized and identified as Acinetobacter johnsonii and Sinorhizobium sp., respectively. The A. johnsonii AFK-07 exhibited a high level of degradatory activities against A. flos-aquae, and produced alginase, caseinase, lipase, fucodian hydrolase, and laminarinase. Moreover, many kinds of glycosidase, such as ${\beta}-galactosidase,\;{\beta}-glucosidase,\;{\beta}-glucosaminidase,\;and\; {\beta}-xylosidase$, which hydrolyzed ${\beta}-O-glycosidic$ bonds, were found in cell-free extracts of A. johnsonii AFK-07. Other glycosidases such as ${\alpha}-galactosidase,\;{\alpha}-N-Ac-galactosidase,\;{\alpha}-mannosidase,\; and\;{\alpha}-L-fucosidase$, which cleave ${\alpha}-O-glycosidic$ bonds, were not identified in AFK-07. In the Sinorhizobium sp. AFK-13, the enzymes alginase, amylase, proteinase (caseinase and gelatinase), carboxymethyl-cellulase (CMCase), laminarinase, and lipase were notable. No glycosidase was produced in the AFK-13 strain. Therefore, the enzyme system of A. johnsonii AFK-07 had a more complex mechanism in place to degrade the cyanobacteria cell walls than did the enzyme system of Sinorhizobium sp. AFK-13. The polysaccharides or the peptidoglycans of A. flos-aquae may be hydrolyzed and metabolized to a range of easily utilized monosaccharides or other low molecular weight organic substances by strain AFK-07 of. A. johnsonii, while the products of polysaccharide degradation or peptidoglycans were more likely to be utilized by Sinorhizobium sp. AFK-13. These bacterial interactions may offer an alternative effective approach to controlling the water choking effects of summer blooms affecting our lakes and reservoirs.

고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수 (Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter)

  • 김광태
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.35-43
    • /
    • 2005
  • 종래의 컨버터-인버터 전력변환 시스템에서 do-link를 제거하여 보다 효과적인 인버터를 만들기 위하여 매트릭스 컨버터에 관하여 연구를 하고자 한다. 따라서 매트릭스 컨버터는 에너지를 저장하는 능동소자를 갖지 않는 장점이 있으나 전원이 스위치를 통하여 직접 부하에 연결되므로 전원의 리플과 노이즈가 그대로 부하에 전달되는 결점을 갖는다. 매트릭스 컨버터는 전원을 부하에 대하여 정현적으로 스위칭해야 되며, 한편 이러한 노이즈를 제거 및 보상하는 특성과 함께 역율문제도 함께 해결해야 한다. 본 연구에서는 종래의 제시된 방법에 비하여 제어어시간을 단축시킨 제어함수를 제시한다. 제시된 제어함수는 전원에 포함된 리플과 노이즈를 스위칭하는 과정에서 자동으로 보상하며 역율 1이되게 스위칭한다. 시뮬레이션 결과와 실험결과를 함께 제시한다.

Hexose Uptake and Kinetic Properties of the Endogenous Sugar Transporter(s) in Spodoptera frugiperda Clone 21-AE Cells

  • Lee Chong-Kee
    • 대한의생명과학회지
    • /
    • 제11권3호
    • /
    • pp.327-332
    • /
    • 2005
  • Sf21 cells become popular as the host permissive cell line to support the baculovirus AcNPV replication and protein synthesis. The cells grow well on TC-100 medium that contains $0.1\%$ D-glucose as the major carbon source, strongly suggesting the presence of endogenous glucose transporters. However, unlike human glucose transporters, very little is known about the characteristics of the endogenoussugar transporter(s) in Sf21 cells. Thus, some kinetic properties of the sugar transport system were investigated, involving the uptake of 2-deoxy-D-glucose (2dG1c). In order to obtain a true measure of the initial rate of uptake, the uptake of $[^3H]2dGlc$ from both low $(100{\mu}M)$ and high (10 mM) extracellular concentrations was measured over periods ranging from 30 sec to30 min. The data obtained indicated that the uptake was linear for at least 2 min at both concentrations, suggesting that measurements made over a 1min time course would reflect initial rates of the jexpse uptake. To determine $K_m\;and\;V_{max}$ of the endogenous glucose transporter(s) in Sf21 cells, the uptake of 2dG1c was measured over a range of substrate concentrations $(50{\mu}M\~10mM)$ 2dG1c uptake by the Sf21 cells appeared to involve both saturable and non-saturable (or very low affinity) components. A saturable transport system for 2dG1c was relatively high, the $K_m$ value for uptake being < 0.45 mM. The $V_{max}$ value obtained for 2dG1c transport in the Sf21 cells was about 9.7-folds higher than that reported for Chinese hamster ovary cells, which contain a GLUT1 homologue. Thus, it appeared that the transport activity of the Sf21 cells was very high. In addition, the Sf21 glucose transporter was found to have very low affinity for cytochalasin B, a potent inhibitor of human erythrocyte glucose transporter

  • PDF

Non-LOCA 인허가 해석용 TASS 코드의 개발 (Development of TASS Code for Non-LOCA Safety Analysis Licensing Application)

  • Yoon, Han-Young;Auh, Geun-Sun;Kim, Hee-Cheol;Kim, Joon-Sung;Park, Jae-Don
    • Nuclear Engineering and Technology
    • /
    • 제27권1호
    • /
    • pp.53-66
    • /
    • 1995
  • 현재 사용중인 Non-LOCA 해석용 인허가 코드들은 특정한 형태의 가압경수로에 맞게 짜여진 것들이어서 모든 형태의 가압 경수로에 적용할 수 있는 범용 코드의 개발이 필요한 실정이다. 이를 위하여 한국원자력연구소에서는 웨스팅하우스 및 CE형 발전소에 공히 적용할 수 있는 과도현상 해석 코드인 TASS 로드를 개발하고있다. 이 TASS 코드는 실시 간 보다 빠르게 핵증기계통에 대한 모의 계산을 수행하며 대화식의 입출력을 통하여 사용자가 원하는 과도현상을 정확히 모사할 수 있다. 본 논문에서는 웨스팅하우스형 발전소에 대하여 TASS 코드를 적용하여 Non-LOCA 인허가 해석을 하기 위한 검증을 위해, 교류 전원 상실사고와 부하상실사고에 대하여 발전소 실측자료와의 비교계산을 수행하였고 주급수관 파단사고, 펌프축 고착사고, 증기발생기 세관 파열사고 및 주증기관 파단사고들에 대하여 대형코드인 RELAP5 /MOD3 코드와의 비교계산을 수행하였다.

  • PDF

만성폐쇄성폐질환 동물모델에 대한 射干湯 및 구성약물의 효과 (Effects of Sagan-tang and individual herbs on COPD Mice Model)

  • 한종민;양원경;김승형;박양춘
    • 대한한의학방제학회지
    • /
    • 제23권2호
    • /
    • pp.171-187
    • /
    • 2015
  • Objective This study aimed to evaluate the effects of Sagan-tang (SGT) on COPD mouse model. Methods The study was carried out by two ways (in vitro, in vivo). In vitro RAW264.7 cells (mouse macrophage) were used and analysed by flow cytometry, ELISA, Western blot. In vivo LPS and CSS challenged mice were used and its BALF had been analysed by cytospin image, FACS, ELISA, lung tissue by real-time PCR. Results In vitro, SGT maintained 80-100% rate of viablilty on 10 ~ 500 ㎍/㎖ concentration. In ELISA analysis with RAW264.7 cells, SGT significantly decreased NO over 30 ㎍/㎖. In flow cytometry, SGT 100 ㎍/㎖ dosage group displayed a tendency for decrease ROS. In Western blot analysis, SGT 100 ㎍/㎖ dosage group decreased NF-κB. In ELISA analysis, SGT significantly decreased TNF-α, IL-6 over 200 ㎍/㎖. In vivo SGT 200 ㎎/㎏ dosage group, application of SGT significantly decreased increase of neutrophils, TNF-α, IL-6 in BALF, muc5AC, TGF-β, TNF-α, expression of mRNA in lung tissue and histological lung injury. Conclusion This Study suggests usability of SGT for COPD patients by controlling lung tissue injury.