• Title/Summary/Keyword: A-Scan

Search Result 4,823, Processing Time 0.057 seconds

Boundary Scan Test Methodology for Multiple Clock Domains (다중 시스템 클럭 도메인을 고려한 경계 주사 테스트 기법에 관한 연구)

  • Jung, Sung-Won;Kim, In-Soo;Min, Hyoung-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1850-1851
    • /
    • 2007
  • To the Boundary Scan, this architecture in Scan testing of design under the control of boundary scan is used in boundary scan design to support the internal scan chain. The internal scan chain has single scan-in port and single scan-out port that multiple scan chain cannot be used. Internal scan design has multiple scan chains, those chains must be stitched to form a scan chain as this paper. We propose an efficient Boundary Scan test structure for multiple clock testing in design.

  • PDF

Efficient Test Data Compression and Low Power Scan Testing in SoCs

  • Jung, Jun-Mo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.25 no.5
    • /
    • pp.321-327
    • /
    • 2003
  • Testing time and power consumption during the testing of SoCs are becoming increasingly important with an increasing volume of test data in intellectual property cores in SoCs. This paper presents a new algorithm to reduce the scan-in power and test data volume using a modified scan latch reordering algorithm. We apply a scan latch reordering technique to minimize the column hamming distance in scan vectors. During scan latch reordering, the don't-care inputs in the scan vectors are assigned for low power and high compression. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases.

  • PDF

Test Methodology for Multiple Clocks in Systems (시스템 내에 존재하는 다중 클럭을 제어하는 테스트 기법에 관한 연구)

  • Lee, Il-Jang;Kim, In-Soo;Min, Hyoung-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1840-1841
    • /
    • 2007
  • To the Boundary Scan, this architecture in Scan testing of design under the control of boundary scan is used in boundary scan design to support the internal scan chain. The internal scan chain has single scan-in port and single scan-out port that multiple scan chain cannot be used. Internal scan design has multiple scan chains, those chains must be stitched to form a scan chain as this paper. We propose an efficient Boundary Scan test structure for multiple clock testing in design.

  • PDF

Bone Marrow Immunoscintigraphy for the Detection of Skeletal Metastasis in Malignant Tumors: A Comparison with $^{99m}Tc$-MDP Bone Scan (악성종양에서 골수면역신티그라피를 이용한 골수전이의 평가 : $^{99m}Tc$-MDP 뼈스캔과의 비교)

  • Lee, Kyung-Han;Choi, Chang-Woon;Bang, Yung-Jue;Chung, Jun-Key;Chung, Hong-Keun;Lee, Myoung-Chul;Kim, Byoung-Kook;Kim, Noe-Kyeong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.89-97
    • /
    • 1994
  • Although bone scan is a highly sensitive test for detecting bone metastasis, its findings are often limited in specificity and cannot be used for assessing the bone marrow. Bone marrow scintigraphy may provide useful information but previous experience with radiolabelled colloid has been disappointing. Recently, $^{99m}Tc$ labeled anti-granulocyte monoclonal antibody (anti-NCA-95 MAb) has been introduced as a new bone marrow imaging agent. To evaluate the usefulness of $^{99m}Tc$ anti-NCA MAb bone marrow scans for detecting skeletal metastasis, bone marrow scans of 44 malignant tumor patients were evaluated and compared with bone scan findings. Bone scan showed abnormal lesions in 26(59%) cases, and 18 of these patients also had an abnormal bone marrow scan. Seven of the 8 patients who had normal bone marrow scan despite bone scan lesions were confirmed to be free from metastasis. There was one case with a marrow defect despite normal bone scan but the presence of metastasis was not determined due to loss of follow up. Bone scan demonstrated a total of 64 lesions while bone marrow scan showed 38 lesions. Fifty percent (32/64) of the bone scan lesions had matching marrow defects while the remaining 50% did not. Most of these non matched lesions were suggested to be nonspecific lesions such as rib fractures or degenerative change. Meanwhile bone marrow scan was able to detect 6 new lesions not detected by bone scan, bit metastasis in each lesion was not confirmed. Bone marrow scan was also helpful in assessing equivocal bone scan lesions to be of metastatic nature in 10 patients by demonstrating a matched marrow defect. Thus $^{99m}Tc$ anti-NCA MAb bone marrow scan can help exclude metastasis in patients with nonspecific bone scan lesions and may be able to detect metastatic lesions not seen with bone scan. It appears useful as a complementary study to bone scan in evaluating malignant tumor patients.

  • PDF

A New Scan Partition Scheme for Low-Power Embedded Systems

  • Kim, Hong-Sik;Kim, Cheong-Ghil;Kang, Sung-Ho
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.412-420
    • /
    • 2008
  • A new scan partition architecture to reduce both the average and peak power dissipation during scan testing is proposed for low-power embedded systems. In scan-based testing, due to the extremely high switching activity during the scan shift operation, the power consumption increases considerably. In addition, the reduced correlation between consecutive test patterns may increase the power consumed during the capture cycle. In the proposed architecture, only a subset of scan cells is loaded with test stimulus and captured with test responses by freezing the remaining scan cells according to the spectrum of unspecified bits in the test cubes. To optimize the proposed process, a novel graph-based heuristic to partition the scan chain into several segments and a technique to increase the number of don't cares in the given test set have been developed. Experimental results on large ISCAS89 benchmark circuits show that the proposed technique, compared to the traditional full scan scheme, can reduce both the average switching activities and the average peak switching activities by 92.37% and 41.21%, respectively.

  • PDF

Sensitivity of Dimercaptosuccinic Acid(DMSA) Renal Scan in Children with Acute Pyelonephritis (급성 신우신염 환아들의 나이에 따른 Dimercaptosuccinic Acid Renal Scan 민감도)

  • Jang Kyung-Ah;Yang Jeong-A;Hah Tae-Sun;Park Hye-Won;Lee Jun-Ho
    • Childhood Kidney Diseases
    • /
    • v.7 no.1
    • /
    • pp.38-43
    • /
    • 2003
  • Purpose : Accurate diagnosis of acute pyelonephritis(APN) using clinical and laboratory parameters is often difficult in children. Clinical and experimental studies have demonstrated that renal scarring can be prevented or diminished by early diagnosis and aggressive treatment of acute pyelonephritis. dimercaptosuccinic acid(DMSA) renal scan has been reported to be useful in children for confirmation of the diagnosis of acute pyelonephritis. An analysis was undertaken to correlate the clinical and laboratory manifestations of APN With the results of the DMSA renal scan in different age groups. Methods : We determined the sensitivity of DMSA renal scan in febrile urinary tract infections(UTI) in two groups according to age : group I in less than 2 years; group II in older than 2 years. During the period March 2001 through September 2002, 67 children presented with febrile UTIs. All patients had DMSA renal scan done in the acute period, 55 had voiding cystourethrography(VCUG) and 66 had renal ultrasonogram(RUS) done. Results : There were no significant difference between the two groups in DMSA renal scan (P>0.05). But, in group I sensitivity of DMSA renal scan was 47%; in group II sensitivity of DMSA renal scan was 70%. The grade of reflux correlated with a positive DMSA renal scan. Vesicoureteral reflux did not correlate with age. RUS did not correlate with a positive DMSA renal scan in any age group. Abnormality of RUS did not correlate with age. Conclusion : At present, we believe that DMSA renal scan is the prevailing method in differention of the APN. In addition, it is not invasive and less costly. Even though there is no statistical difference in the sensitivity of DMSA renal scan between young and older children, we can observe that in the younger group, the sensitivity of DMSA renal scan seemed to be lower(47%).

  • PDF

Improvement Of Address Voltage Margin for Slope Overlapped Scan Method in AC-PDP (AC-PDP 어드레스 전압마진 개선을 위한 Slope Overlapped Scan Method 구현)

  • Kim, Tae-Gyun;Lim, Beong-Ha;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.460-461
    • /
    • 2008
  • A new AC-PDP driving method was proposed to reduce the address period. The overlapped scan method can reduce the address period. However, this method has a narrow address voltage margin compared with conventional scan method in this paper, Slope overlapped scan method is presented. The proposed new overlapped scan method allows wider address voltage margin than conventional overlapped scan method.

  • PDF

A Low Power scan Design Architecture (저전력을 고려한 스캔 체인 구조 변경)

  • Min, Hyoung-Bok;Kim, In-Soo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.7
    • /
    • pp.458-461
    • /
    • 2005
  • Power dissipated during test application is substantially higher than power dissipated during functional operation which can decrease the reliability and lead to yield loss. This paper presents a new technique for power minimization during test application in full scan sequential circuits. This paper shows freezing of combinational logic parts during scan shift operation in test mode. The freezing technique leads to power to minimization. Significant power reduction in the scan techniques is achieved on ISCAS 89 benchmarks.

A Study on the Performance Analysis of an Extended Scan Path Architecture (확장된 스캔 경로 구조의 성능 평가에 관한 연구)

  • 손우정
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 1998
  • In this paper, we propose a ESP(Extended Scan Path) architecture for multi-board testing. The conventional architectures for board testing are single scan path and multi-scan path. In the single scan path architecture, the scan path for test data is just one chain. If the scan path is faulty due to short or open, the test data is not valid. In the multi-scan path architecture, there are additional signals in multi-board testing. So conventional architectures are not adopted to multi-board testing. In the case of the ESP architecture, even though scan path is either short or open, it doesn't affect remaining other scan paths. As a result of executing parallel BIST and IEEE 1149.1 boundary scan test by using the proposed ESP architecture, we observed that the test time is short compared with the single scan path architecture. By comparing the ESP architecture with single scan path responding to independency of scan path, test time and with multi-scan path responding to signal, synchronization, we showed that the architecture has improved results.

  • PDF

Efficient Test Data Compression and Low Power Scan Testing for System-On-a-Chip(SOC) (SOC(System-On-a-Chip)에 있어서 효율적인 테스트 데이터 압축 및 저전력 스캔 테스트)

  • Park Byoung-Soo;Jung Jun-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.1
    • /
    • pp.229-236
    • /
    • 2005
  • Testing time and power consumption during testing System-On-a-Chip (SOC) are becoming increasingly important as the IP core increases in a SOC. We present a new algorithm to reduce the scan-in power and test data volume using the modified scan latch reordering. We apply scan latch reordering technique for minimizing the hamming distance in scan vectors. Also, during scan latch reordering, the don't care inputs in scan vectors are assigned for low power and high compression. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases.

  • PDF