• Title/Summary/Keyword: A body shape index

Search Result 191, Processing Time 0.032 seconds

Estimation of Computed Tomography Dose in Various Phantom Shapes and Compositions (다양한 팬텀 모양 및 재질에 따른 전산화단층촬영장치 선량 평가)

  • Lee, Chang-Lae
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • The purpose of this study was to investigate CTDI (computed tomography dose index at center) for various phantom shapes, sizes, and compositions by using GATE (geant4 application for tomographic emission) simulations. GATE simulations were performed for various phantom shapes (cylinder, elliptical, and hexagonal prism PMMA phantoms) and phantom compositions (water, PMMA, polyethylene, polyoxymethylene) with various diameters (1-50 cm) at various kVp and mAs levels. The $CTDI_{100center}$ values of cylinder, elliptical, and hexagonal prism phantom at 120 kVp, 200 mAs resulted in 11.1, 13.4, and 12.2 mGy, respectively. The volume is the same, but $CTDI_{100center}$ values are different depending on the type of phantom. The water, PMMA, and polyoxymethylene phantom $CTDI_{100center}$ values were relatively low as the material density increased. However, in the case of Polyethylene, the $CTDI_{100center}$ value was higher than that of PMMA at diameters exceeding 15 cm ($CTDI_{100center}$ : 35.0 mGy). And a diameter greater than 30 cm ($CTDI_{100center}$ : 17.7 mGy) showed more $CTDI_{100center}$ than Water. We have used limited phantoms to evaluate CT doses. In this study, $CTDI_{100center}$ values were estimated and simulated by GATE simulation according to the material and shape of the phantom. CT dosimetry can be estimated more accurately by using various materials and phantom shapes close to human body.

Hatching Rate of Eggs, and Growth of Larvae and Juveniles from Selected Olive Flounder, Paralichthys olivaceus (선발 육종된 넙치, Paralichthys olivaceus의 부화율 및 자치어 성장)

  • Min, Byung-Hwa;Lee, Jeong-Ho;Noh, Jae-Koo;Kim, Hyun-Chul;Park, Choul-Ji;Choi, Sang-Jun;Myeong, Jeong-In
    • Development and Reproduction
    • /
    • v.13 no.4
    • /
    • pp.239-247
    • /
    • 2009
  • Hatching rate, larval deformation and growth rate of selected olive flounder (Paralichthys olivaceus) for rapid growth were compared to those of the unselected fish. Fish were spawned on the same day and cultured under the similar conditions. The selected fish had a significantly higher eggs hatching rate, and lower larval deformation. The selected fish grew significantly faster, and at the end of the experiment (8 weeks after hatching) averaged 50.49${\pm}$2.67 mm in total length, 16.30${\pm}$0.08 mm in body height, and 1.036${\pm}$0.118 g in weight, compared to 40.55${\pm}$3.13 mm, 13.50${\pm}$0.96 mm, and 0.557${\pm}$0.073 g for unselected fish, respectively. The selected fish had a significantly higher body shape index, however lower condition factor than the unselected fish. The results of the present study demonstrate that the selected fish of the olive flounder for rapid growth had superior growth and improved body shape.

  • PDF

A Comparative Study of Food Habits and Body Satisfaction of Middle School Students According to Clinical Symptoms (일부 남녀 중학생의 건강 관련 임상증상에 따른 식습관과 체헝관심도에 관한 연구)

  • Sung, Chung-Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.202-208
    • /
    • 2005
  • This study was conducted to examine the food habits, knowledge of nutrition and actual conditions of food ingestion of adolescent middle school students according to questionnaire answers. Questionnaires were completed by 524 students, divided into a healthy group (n=289) and an unhealthy group (n=235) according to clinical signs. Further questions were asked of the two groups in the areas of food habits, knowledge of nutrition and nutritional attitude. The results were as follows: Mean age of all subjects was 14, heights for male and female students were 162.0 em, and 157.2 cm, weights were 53.4 kg, and 49.4, respectively. Heights and weights of male students were greater than those of female students. The body mass index (BMI) for male and female students was 20.3 kg/$m^2$ and 20.0 kg/$m^2$, respectively, and all data were within normal ranges. There were no significant differences in mean age, height, weight, and BMI between the healthy and unhealthy groups. There was no significant difference in body image recognition between the two groups, although the ratio of dissatisfaction with their own body shape was significantly higher in the female unhealthy group (46.1%), than in the female healthy group (33.0%) (p<0.05). In the area of the struggle to control body weight during the previous year, the female unhealthy group (59.4%) was higher than the female healthy group (38.4%) (p<0.01). There was no significant difference in the scores between the two groups in the areas of knowledge of nutrition and the nutritional attitude. Meal frequency and meal patterns were showed that having breakfast less than 4x/week was significantly higher in the female unhealthy group (44.0%), than in the female healthy group (30.7%) (p<0.01). Meal frequency for suppers<4x/week showed that the female unhealthy group (18.8%) was also higher than the female healthy group (10.7%). Therefore, the unhealthy group exhibited a higher pattern of missing both breakfast and supper. The male unhealthy group (16.7%) dined out more frequently than the male healthy group (12.3%) (p<0.01), and female unhealthy group also indulged in snacking significantly more frequently than the female healthy group. The unhealthy group also ate only 1 item for meals more frequently than the healthy group and no significant difference. The conclusion of this study is that adolescent Korean middle school students, who showed a higher incidence of clinical symptoms, representing an unhealthy status, missed breakfast and supper, and dined out and indulged in snacking more frequently. Their quality of breakfast and satisfaction of body image were also lower than the healthy group. These results indicated that there is a high correlation between a Korean adolescent's health status, food habits and body image satisfaction. It is recommended that a more intense program of nutritional education and monitoring be introduce into the current Korean middle-school system in order to optimally support and maximize the health potential of the current population of Korean student.

A study on food behavior to related health and daily food intakes of female dormitory students according to BMI (체격지수에 따른 기숙사 여대생의 건강과 관련된 식행동과 영양소 섭취량에 대한 연구)

  • 강금지
    • Korean journal of food and cookery science
    • /
    • v.17 no.1
    • /
    • pp.43-54
    • /
    • 2001
  • This study was to investigate the behavior related to health, food habits, food consumption pattern and nutrient intakes of female students who residing in dormitory(self cooking) according to BMI(Body Mass Index). This study was carried out by questionnaired on June, 2000. Three hundred nine students were answered. The results were as follows: 1. The means of height, weight and BMI were 162.37$\pm$4.36cm, 52.48$\pm$5.54kg and 19.89$\pm$1.89. Under 20 of BMI among students were 53.1% and 20-25 of BMI were 46.9% of students. 2. In the self recognition of body shape, 63.4% of under weight subjects answered that their weight were normal. 73.1% of normal weight regard themselves more obese than their actual body shape normally shows. 51.2% of under weight subjects had attempted to control their weight. This results suggest that their weight control attempts were unnecessary. 3. 81.4% of subjects were answered irregular meals regardless BMI. 89.6% of subjects skipped breakfast. The main reasons were due to lack of time or not to eat proper food. Under weight subjects had less snack than normal weight subjects did(p '||'&'||'lt; 0.05). Normal weight subjects had more bun and cake than under weight subjects(p '||'&'||'gt; 0.05). 4. The consumption of vegetables and fruits were low regardless BMI. Mean energy, protein, Fe, Vit A, B$_1$, B$_2$, niacin, Vit C were above 75% of RDA, except calcium, in subjects. This study suggest that a comprehensive nutrition education program is need for college student in dormitory to improve their eating habits about skipping meal and breakfast and to increase the consumption of vegetables and fruits.

  • PDF

Sexual Maturity and Gonadal Development of Slime Flounder, Microstomus achne (찰가자미, Microstomus achne의 성성숙과 생식소발달)

  • Byun, Soon-Gyu;Kim, Sung-Yeon;Kim, Jin-Do;Lee, Bae-Ik;Lee, Jong-Ha;Han, Kyeong-Ho;Jeong, Min-Hwan
    • Korean Journal of Ichthyology
    • /
    • v.23 no.3
    • /
    • pp.179-186
    • /
    • 2011
  • Slime flounder, Microstomus achne is distributed in the coastal waters of Korea, west sea of Japan, BoHai, Yellow sea and East china sea. They are mainly caught by bottom trawl net during winter, from December to March. Sexual maturation of slime flounder were investigated using samples collected from commercial catch in the southern coast of Korea from November, 2006 to March, 2007. The ovary of the slime flounder is a conical bag in shape and is bilateral structure develops lengthily from the posterior of the abdomen to the end of the anal fin. The testis also is bilateral in structure, usually located in small size in the abdomen. In females, the gonadosomatic index (GSI) were peaked in January (12.46), then decreased rapidly thereafter. Female GSI values plummeted to 2.72 in March just after spawning. Male GSI values were peaked in December (2.46) before in the spawning season, then decreased slowly thereafter. The reproductive cycle would be classified into three successive developmental stages : maturation stage (November to January), ripe and spawning stage (December to February), degenerative and resting stage (February to March). Relationships between the fish sizes in total length (TL) and the number of ovarian eggs (F), the body weights (BW) and the number of ovarian eggs were indicated by the exponential equation respectively: F=29.027TL-767.8 (r$^2$=0.7686), F=0.3998BW+24.288 (r$^2$=0.8919).

Examination of Economic Performance of Egg Type Breeder Lines for the Selection of Fowl-Typhoid Resistant Breed (가금티푸스 저항성 계통 선발을 위한 산란종계의 경제능력 검정에 관한 연구)

  • Han, Sung-Wook;Lee, Bong-Duk;Jeon, Ik-Soo
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.70-77
    • /
    • 2001
  • A preliminary experiment was conducted to produce fowl-typhoid resistant egg type breeds, using three brown egg layer breeders (ISA, Hyline, and Lohman) and two white egg layer breeders (ISA and Lohman). Various economic parameters were measured from day-old to mature stages using parent stocks of each breed. No significant difference in viabilities of mature hens from 34 to 66 wk of ages was found between brown(93.3%) and white(93.5%) egg layer breeders (P>0.05). Also, there was no difference in viabilities of mature cockerels. Although not significant, the mature body weights of brown egg layer breeders tended to be heavier than those of the white egg layer breeders both in hens and cockerels. No difference in feed intakes of mature brown and white hens were detected. Ages of sexual maturity of white and brown egg layer hens were 147.7 and 140.5 d, respectively (P<0.05). Egg production of white egg layer hens during 23-66 weeks age was significantly higher than their counterpart (81.4% vs. 75.0%). Comparisons of Haugh Unit, egg shape index, yolk color, and egg weight between brown and white eggs were not significantly different; however, the brown eggshells were thicker and stronger than those of white eggs (P<0.05).

  • PDF

Zooplankton Community as an Indicator for Environmental Assessment of Aquatic Ecosystem: Application of Rotifer Functional Groups for Evaluating Water Quality in Eutrophic Reservoirs (동물플랑크톤 군집의 수생태계 환경 평가 지표 활용: 부영양화 저수지 수질 평가를 위한 윤충류 기능성 그룹의 적용)

  • Oh, Hye-Ji;Chang, Kwang-Hyeon;Seo, Dong-Il;Nam, Gui-Sook;Lee, Eui-Haeng;Jeong, Hyun-Gi;Yoon, Ju-Duk;Oh, Jong Min
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.6
    • /
    • pp.404-417
    • /
    • 2017
  • In this study, we analyzed response patterns of rotifer community to eutrophic state, and estimated the applicability of rotifer community as an environmental indicator for highly eutrophicated reservoirs. In order to evaluate the relationships among spatial and temporal distributions and the water quality of rotifer community, we selected the Jundae Reservoir and Chodae Reservoir in Chungcheongnam-do, Korea, which are geographically adjacent but have different water quality, particularly in their eutrophic states. For the analyses on their correlations, monthly survey of water quality and rotifer community, was conducted from April to November 2013 in both reservoirs. The rotifer community was divided into different compositions of functional groups as well as species. Functional groups were classified according to the structure and shape of trophi which can represent feeding behavior of rotifer genus. To reflect ecological characteristics of species, body size and habitat preferences were also considered. Species-based composition did not show a consistent tendency with water quality parameters related with eutrophication. On the contrary, functional group composition showed relatively clear group-specific patterns, increasing or decreasing according to the parameters. The results suggest the possible application of rotifer functional group composition as an indicatorforthe lentic systems, especially hyper-eutrophicated reservoirs. The present study can suggest the applicability based on the field observations from the limited time scale and sites, and further studies on feeding behavior of the rotifer functional group and its interactions with environmental variables are necessary for the further application.

Research of Chemical Properties of Soil and Growth Characteristics of Panax ginseng under Organic and Conventional Cultivation Systems in Korea (국내 유기와 관행 재배 인삼의 토양화학성과 생육 특성 조사)

  • Lim, Jin-Soo
    • Korean Journal of Organic Agriculture
    • /
    • v.24 no.3
    • /
    • pp.435-451
    • /
    • 2016
  • The objective of the present study was to perform a comparative analysis of the chemical properties of the cultivation site soil and growth characteristics of organically and conventionally cultivated ginseng (Panax ginseng C. A. Meyer). Organically and conventionally cultivated ginseng samples (4-, 5-, and 6-year-old) were collected from 52 fields at 14 locations throughout Korea. The samples were collected over three years from 2013 to 2015, with the collection period between October and November of each year. In order to increase the yield of organically cultivated ginseng, the amount of nutrients was increased to match that of the conventional cultivation system, which highlights the need for proper management in accordance with the standards for chemical properties of soil. Growth duration of organic ginseng was ${\geq}60days$ shorter than that of conventional ginseng and its average yield per 1ha was 60% than that of conventional ginseng. Root weight of organically cultivated ginseng was approximately 54% that of conventionally cultivated ginseng. Rhizome diameter and body shape index of organically cultivated ginseng were lower than those of conventionally cultivated ginseng, indicating that organically cultivated ginseng was thinner and longer than conventionally cultivated ginseng. Root length was greater in 5-year-old conventionally cultivated ginseng with a low percentage of paddy-upland rotation fields. The number of rootlets was lower in 5- and 6-year-old organically cultivated ginseng with a high percentage of direct seeding cultivation. Dry weight was distinctly lower in 5- and 6-year-old organically cultivated ginseng with early defoliation than that of conventionally cultivated ginseng. Incidences of notched belly and root rot tended to be higher in conventional cultivation, with the incidence of notched belly being distinctly higher in 4- and 6-year-old roots and root rot being more prevalent in 5- and 6-year-old roots. Red discoloration and eelworm damage, which are highly affected by soil moisture, were most common in the organically cultivated 4-year-old roots. Organically cultivated ginseng showed early defoliation than conventionally cultivated ginseng, as a result, its yield and weight were low, while the incidence of physiological disorders was low. In order to increase the yield of organically cultivated ginseng, studies on cultivation technology that can overcome early defoliation, as well as soil moisture management that can minimize physiological disorders, are required.

The Effects of Chest Injury in the Early Deaths of Trauma Patients (외상에 의한 초기 사망에서 흉부손상에 대한 고찰)

  • Lee Dong Hoon;Cho Dai Yun;Kim Chan Woong;Sohn Dong Suep
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.127-133
    • /
    • 2006
  • Background: In the studies of the distribution of time to death in trauma patients, the early deaths within several hours after injury were a large component of total trauma deaths. Due to the development of trauma system, overall mortality of trauma was decreased, but trauma is still the major cause of deaths. Material and Method: From January 1994 to December 2003, trauma patients who had been admitted and had expired at tertiary hospital were enrolled. There was a total of 400 cases, a retrospective study was done to determine the distribution of trauma mortality according to the part of the body that were severely injured part and compared the difference between early deaths within 6 hours and late deaths after 6 hours. We also analysed the risk factors of early deaths due to trauma. Result: In severe injury to the head and abdomen, the distribution of mortality was bimodal. But, in severe chest injuries, the distribution was log-shape and most early deaths were almost of trauma related. The average of GCS were 5.86$\pm$4.15 for the early deaths and 8.24$\pm$5.02 for the late deaths (p < 0.05). The AIS of thorax were 2.66$\pm$1.87 for the early deaths and 1.55$\pm$1.76 for late deaths. The risk factors for early mortality were non-EMS transportation (odds ratio 3.474), high AIS (odds ratio 1.491) and GCS (odds ratio 0.859). Conclusion: In trauma patients, the causes of early mortality were severe brain injury and massive hemorrhage. Also severe chest injuries were the major cause of the early deaths in truama. Early diagnosis of chest injury can frequently be missed in the acute trauma setting. Therefore, high index of suspicion, a careful examination, and aggressive surgical treatment are important in multiple trauma patients.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF