• 제목/요약/키워드: A B and C scan images

검색결과 31건 처리시간 0.025초

수동형 Stainless Steel, Nickel-Titanium 및 엔진 구동형 Nickel-Titanium File의 근관형성 능력에 관한 비교 연구 (A STUDY ON COMPARISON OF STAINLESS STEEL, NICKEL-TITANIUM HAND, NICKEL-TITANIUM ENGINE-DRIVEN FILE INSTRUMENTATION USING COMPUTED TOMOGRAPHY)

  • 이황;임미경;이건일;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.391-400
    • /
    • 1998
  • The aim of this study was to determine the shaping ability of stainless-steel K file (S-S K file), nickel-titanium K file (Ni-Ti K file) and engine driven nickel-titanium file (Quantec file) in resin simulated root canal. Computed tomography was used to evaluate the change of the root canal morphology. Thirty nine resin simulated root canal were divided into four groups (A:12, B:12, C:12, D:3). Resin simulated canals were scanned by computed tomography before instrumentation (1st C-T scan). Canals were instrumented using step back preparation technique with S-S K file in group A and Ni-Ti K file in group B. Group C was prepared with engine driven Ni-Ti file. Group D was uninstrumented to compare the 1st C-T scan images with 2nd C-T scan images of root canal. Instrumented canals were again scanned using computed tomography (2nd C-T scan), and reformated images of the uninstrumented canals were compared with images of the instrumented canals. In the sections of 2mm and 6mm from the apex, Quantec file caused significantly less canal transportation than S-S K file and Ni-Ti K file (p<0.05). Quantec file produced more centered than S-S K file and Ni-Ti K file in the sections of 2mm and 4mm from the apex (p<0.05). There was no significant difference in the removed volume of canals among the each groups (p>0.05). However the removed canal volume from the apex to 5mm were significantly higher than them from 5mm to 1mm (p<0.05) in each groups. Under the conditions of this study, preparation with Quantec file was more effective and produce more appropriate canal shapes than S-S K file and Ni-Ti K file.

  • PDF

핵발전소 증기발생기의 초음파 비파괴 평가를 위한 영상처리 소프트웨어 개발 (Development of Image Processing Software for UT-NDE of Steam Generator of Nuclear Power Plant)

  • 이영석;남명우
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.226-231
    • /
    • 2007
  • 본 논문은 핵발전소의 초음파 비파괴 평가를 수행하기 위하여 구현된 초음파 신호 분석 소프트웨어에 관한 것이다. 구현된 소프트웨어는 1차원 초음파 신호뿐만 아니라 이를 가공하여 B, C 및 D 스캔 영상으로의 확장이 가능하고 각 스캔 영상으로부터 의미 있는 파라메터를 측정할 수 있는 기능을 갖추고 있다. 구현된 소프트웨어는 이미 알고 있는 시편의 결함에 적용하여 프로그램의 정확성을 검증하였다.

  • PDF

유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가 (Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery)

  • 최영재;권대철
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.92-98
    • /
    • 2016
  • 신호증강효과기법을 이용한 자기공명혈관술에서 뇌동맥을 half scan factor에 따른 절반스캔과 완전스캔의 영상을 평가하는데 목적으로 한다. 뇌혈관성 질환이 없는 환자(n = 30)를 대상으로 절반스캔과 완전스캔 하였고, 뇌동맥의 관심영역을 세 영역(C1, C2, C3)에서 7~8 mm의 범위로 설정하였다. MIP로 재구성한 영상으로 신호강도를 SNR(signal to noise ration), PSNR(peak signal noise to ratio), RMSE(root mean square error), MAE(mean absolute error)을 산출하고 paired t-test를 이용하여 통계분석 하였다. 스캔시간은 절반스캔(4분 53초), 완전스캔(6분 04초)이었다. 뇌혈관의 모든 ROI의 평균 측정 범위(7.21 mm)이었고, 첫번째 C1의 SNR은 완전스캔(58.66 dB), 절반스캔(62.10 dB)이었고, 양의 상관관계($r^2=0.503$)이고, 두 번째 C2의 SNR은 완전스캔(70.30 dB), 절반스캔(74.67 dB)이고 양의 상관관계($r^2=0.575$)이었다. 세 번째 C3의 완전스캔 SNR(70.33 dB), 절반스캔 SNR (74.64 dB)로 양의 상관관계를 ($r^2=0.523$)로 분석되었다. 절반스캔과 완전스캔의 비교에서 SNR($4.75{\pm}0.26dB$), PSNR($21.87{\pm}0.28dB$), RMSE($48.88{\pm}1.61$)이었고 MAE($25.56{\pm}2.2$)로 산출되었다. SNR은 두 검사 스캔에서 통계학적으로 유의하지 않았고 (p-value > .05) 영상의 질에서는 많은 차이가 없어 완전스캔을 사용하였을 때보다 적은 시간이 소요되는 절반스캔을 적용하여 검사하여도 된다.

A SOURCE EXTRACTION METHOD FOR THE AKARI MID-IR FAINT SOURCE CATALOGUE

  • Nakamichi, Keichiro;Ishihara, Daisuke;Kaneda, Hidehiro;Oyabu, Shinki;Kondo, Toru;Amatsutsu, Tomoya;Sano, Hidetoshi;Onaka, Takashi
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.29-31
    • /
    • 2017
  • We plan to produce a faint source catalogue from the AKARI mid-infrared (IR) all-sky diffuse maps. In the publicly-available AKARI mid-IR point source catalogue (PSC), sources were extracted from single-scan images, and confirmed by using the other scan images. By stacking multiple scan images, we can detect fainter sources which are not listed in the PSC. We optimized the source extraction process using a $6^{\circ}{\times}6^{\circ}C$ area around the star-forming region, Cepheus B. Then, we divided the all-sky data into three seasonal images, and checked the positions and the fluxes of the detected sources on the images. As a result, our new source extraction method works well; 90% of the sources are also identified in the WISE catalogue. In this method, we obtain the detection limit twice deeper than that of the PSC. The number of sources increases by a factor of 2, as compared with the PSC.

다중 Echo를 이용한 Single Scan Inhomogeneity Field Mapping (Sine Scan Inhomogeneity Field Mapping using Multiple Echo)

  • 김치영;한수영;정관진;오창현;이윤;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.307-308
    • /
    • 1998
  • In this paper, we describe a field measurement technique using multiple gradient echo method. For this purpose, 3 differential phase map is used between two images obtained in a single scan. The phase map is further processed to unfold phase folding (2n $\pi$). The inhomogeneity map is used to correct image distortion along readout gradient direction. Some experimental results obtained at 1.0 Tesla whole body MR system are shown with the proposed technique.

  • PDF

테라헤르츠파를 이용한 풍력터빈 블레이드 NDE 탐상 평가기법 (NDE Inspecting Techniques for Wind Turbine Blades Using Terahertz Waves)

  • 임광희;김선규;정종안;조영태;우용득
    • 공학기술논문지
    • /
    • 제11권4호
    • /
    • pp.245-251
    • /
    • 2018
  • Terahertz waves (T-ray) was extensively studied for the NDE (nondestructive evaluation) of characterization of trailing edges for a use of turbines composed with composite materials. The used NDE system were consisted of both CW(Continuous wave) and TDS (Time domain spectroscopy). The FRP composites were utilized for two kinds of both trailing edges of wind energy (non-conducting polymeric composites) and carbon fiber composites with conducting properties. The signals of T-ray in the TDS (Time domain spectroscopy) mode resembles almost that of ultrasound waves; however, a terahertz pulse could not penetrate a material with conductivity unlike ultrasound. Also, a method was suggested to obtain the "n" in the materials, which is called the refractive index (n). The data of refractive index (n) could be solved for the trailing edges. The trailing edges were scanned for characterization and inspection. C-scan and B-scan images were obtained and best optimal NDE techniques were suggested for complicated geometry samples by terahertz radiation. Especially, it is found that the defect image of T-ray corresponded with defect locations for the trailing edges of wind mill.

Image Data Interpolation Based on Adaptive Triangulation

  • ;이정식;황재정
    • 한국통신학회논문지
    • /
    • 제32권8C호
    • /
    • pp.696-702
    • /
    • 2007
  • This paper proposes a regional feature preserving adaptive interpolation algorithm for natural images. The algorithm can be used in resolution enhancement, arbitrary rotation and other applications of still images. The basic idea is to first scan the sample image to initialize a 2D array which records the edge direction of all four-pixel squares, and then use the array to adapt the interpolation at a higher resolution based on the edge structures. A hybrid approach of switching between bilinear and triangulation-based interpolation is proposed to reduce the overall computational complexity. The experiments demonstrate our adaptive interpolation and show higher PSNR results of about max 2 dB than other traditional interpolation algorithms.

Digital Shade Analysing System을 이용한 상악 유절치의 색조에 대한 연구 (STUDY ON THE COLORS OF PRIMARY INCISORS USING DIGITAL SHADE ANALYSING SYSTEM)

  • 오민형;이광희;라지영;김대업
    • 대한소아치과학회지
    • /
    • 제33권3호
    • /
    • pp.429-437
    • /
    • 2006
  • 치과치료에서의 심미성 회복에 대한 환자들의 요구는 점차 커지는 추세이며 이러한 치아의 심미적 치과치료에 대한 요구는 영구치에 국한된 것이 아니라 최근에는 유치에서의 심미치료도 중요하게 여겨지고 있다. 치아의 심미성을 결정하는 많은 요소들 중에서 색상과 관련해서는 치과재료의 발달과 함께 많은 변화가 있는 분야이다. 본 연구는 상악 유절치의 색조특성을 분석하고자 digital shade analysis system의 일종인 $ShadeScan^{TM}$ system(Cynovad, Canada)을 이용하여 건강한 상악 유절치의 색조를 분석하였다. 1. 치경부에서는 D2와 D3가 많이 분포되어 있었으며 모든 치아에서 D2가 가장 높은 빈도수를 보였다. 2. 중앙부에서는 C1, D2, B1이 대부분을 차지하였으며 상악 좌측 유측절치를 제외한 나머지 치아에서 C1이 가장 높은 빈도를 보였고 상악 좌측 유측절치는 D2가 가장 높은 빈도를 보였다. 3. 절단부에서는 A2가 대부분을 차지하였으며 다음으로 D2가 많았다. 모든 치아에서 A2가 가장 높은 빈도를 보였으며 다른 부위에 비하여 색조가 A2에 편중되는 경향을 보였다.

  • PDF

초음파 비파괴 검사를 위한 영상처리 소프트웨어 개발 (Development of Image Processing Software for Ultrasonic NDE)

  • 박진홍;남명우;이영석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.459-460
    • /
    • 2007
  • In this paper, we describe a development of ultrasonic nondestructive evaluation software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. And it can analyze the size and the location of internal cracks using 2D image. To do such, we obtain raw data from specimens of real pipeline of power plants, and get the crack points using LPF and differential method from obtained ultrasonic 1-dimensional data. The results of applications showed that the developed software provided accurate images of cracks on various specimens.

  • PDF

핵발전소 증기발생기의 초음파 비파괴 평가를 위한 영상처리 소프트웨어 개발 (Development of Image Processing S/W for UT-NDE of Steam Generator of Nuclear Power Plant)

  • 이영석
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2006년도 춘계학술발표논문집
    • /
    • pp.217-222
    • /
    • 2006
  • This paper describes a development of ultrasonic examination analysis software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. This software provides the information of shape, depth, size and position of flaws. To do such, we obtain raw data from specimens and/or real pipeline of power plants and, modify the obtained ultrasonic 1-dimensional data according to prepared software design schedule. The developed analysis software is applied to specimens containing various flaws with known dimensions. The results of applications showed that the developed software provided accurate and enhanced images of flaws on various specimens.

  • PDF