• Title/Summary/Keyword: 6-Pole

Search Result 449, Processing Time 0.029 seconds

A Reduced Component count Single-stage Electrolytic Capacitor-less Interleaved Totem-pole On-board Battery Charger (적은 소자수를 갖고 전해커패시터가 없는 단일단 인터리브드 토템폴 전기자동차 탑재형 충전기)

  • Kim, Byeong-Woo;Cho, Woo-Sik;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.510-516
    • /
    • 2017
  • This paper proposes a single-stage interleaved totem-pole on-board battery charger with a simple structure and a reduced component count. Apart from achieving ZVS turn-on of all switches and ZCS turn-off of all diodes, this charger does not require an input filter due to its CCM operation and bulky electrolytic capacitors, which in turn result in a high power density. A single-stage power conversion technique is applied to the interleaved structure in order to achieve a high power density and high efficiency. A 2.5 kW prototype of the proposed charger is also built and tested to validate the proposed operation.

A Six Pole Permanent Magnet Biased Homopolar Magnetic Bearing with Fault-Tolerant Capability

  • Uhn Joo Na
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.2_1
    • /
    • pp.231-238
    • /
    • 2023
  • This paper develops the theory for a novel fault-tolerant, permanent magnet biased, 6-active-pole, homopolar magnetic bearing. The Lagrange Multiplier optimization with equality constraints is utilized to calculate the optimal distribution matrices for the failed bearing. some numerical examples of distribution matrices are provided to illustrate the new theory. Simulations show that very much the same dynamic responses (orbits or displacements) are maintained throughout failure events (up to any combination of 3 coils failed for the 6 pole magnetic bearing) while currents and fluxes change significantly. The overall load capacity of the bearing actuator is reduced as coils fail. The same magnetic forces are then preserved up to the load capacity of the failed bearing.

A New Model and Optimal Pole-Placement Control for the Suspension System of Macpherson Type (Macpherson형 현가장치의 새로운 모델링과 최적극배치 제어)

  • 홍금식;전동섭;김철민;유완석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.6
    • /
    • pp.713-721
    • /
    • 1998
  • In this paper a new modeling and an optimal pole-placement control for the suspension system of Macpherson type are investigated. The rotational motion of the unsprung mass is emphasized in the new modeling. The two generalized coordinates selected in the new model are the vortical displacement of sprung mass and the angular displacement of control arm. Both variables are measured from their static equilibrium points. It is shown that the conventional model is a special case of the new model since the transfer function of the new model coincides with that of the conventional one if the lower support point of the shock absorber is located at the mass center of the unsprung mass. It is also shown that the resonance frequencies of the new model agree better with experimental results. Therefore, the new model is more general in the sense that it Provides an extra degree of freedom in determining the plant model for control system design. An optimal pole-placement control which combines LQ control and pole-placement technique is applied to the new model. Simulations are provided.

  • PDF

France's Cluster Policy: the Competitiveness Pole (프랑스의 산업클러스터 정책 -경쟁거점($P{\hat{o}}le$ de $Comp{\acute{e}}titivit{\acute{e}}$)을 중심으로)

  • Jeong, Ok-Ju
    • Journal of the Korean association of regional geographers
    • /
    • v.12 no.6
    • /
    • pp.704-719
    • /
    • 2006
  • The study deals with the France's recent cluster policy represented by the Competitiveness Pole. As a national level cluster supporting policy driven by the central government, the Competitiveness Pole, called 'French cluster model', :is competitiveness-oriented, and principally based on three main factors: partnerships, R&D projects and international visibility. The Competitiveness Pole is also the fruit or a long time effort to establish a decentralized governance system, and it has a lot for Korea to benchmark its relevant policies. After reviewing the Local Production System that was put in place before the Competitiveness Pole, the study treats main aspects or Competitiveness Pole policy. It analyze, then, the significance or the policy in the trend or the overall territorial policy or the country. Lastly, the study provides some implications for Korean policies such as industrial clusters, the Enterprise City and Innovation City.

  • PDF

3-D Inversion of 3-D Synthetic DC Resistivity Data for Vein-type Ore Deposits (국내 맥상광체조사를 위한 3차원 전기비저항 모델링자료의 3차원 역산 해석)

  • Lee, Ho-Yong;Jung, Hyun-Key;Jeong, Woo-Don;Kwak, Na-Eun;Lee, Hyo-Sun;Min, Dong-Joo
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.699-708
    • /
    • 2009
  • Recently as the interest in the development of domestic ore deposits has increased, we can easily find some studies on exploration geophysics-based ore-deposit survey in literature. Based on the fact that mineralized zone are generally more conductive than surrounding media, electrical resistivity survey among several geophysical surveys has been applied to investigate metallic ore deposits. Most of them are grounded on 2-D survey. However, 2-D inversion may lead to some misinterpretation for 3-D geological structures. In this study, we investigate the feasibility of the 3-D electrical resistivity survey to 3-D vein-type ore deposits. We first simulate 2-D dipole-dipole survey data for survey lines normal to the strike and 3-D pole-pole survey data, and then perform 3-D inversion. For 3-D ore-body structures, we assume a width-varying dyke, a wedge-shaped, and a fault model. The 3-D inversion results are compared to 2-D inversion results. By comparing 3-D inversion results for 2-D dipole-dipole survey data to 3-D inversion results for 3-D pole-pole survey data, we could note that the 2-D dipole-dipole survey data yield better inversion results than the 3-D pole-pole data, which is due to the main characteristic of the pole-pole array. From these results, we are convinced that if we have certain information on the direction of the strike, it would be desirable to apply 2-D dipole-diple survey for the survey lines normal to the strike. However, in most cases, we do not have any information on the direction of the strike, because we already developed the ore deposit with the outcrops and the remaining ore deposits are buried under the surface. In that case, performing 3-D pole-pole electrical resistivity survey would be a reasonable choice to obtain more accurate interpretation on ore body structure in spite of low resolution of pole-pole array.

A Study on the Pole-Q Reduction of Chebyshev Function Using Trade-off (트레이드 오프를 이용한 Chebyshev 함수의 극점-Q 감소에 관한 연구)

  • 윤창훈;최석우
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.79-83
    • /
    • 2000
  • When passband ripple α/sub p/ and stopband attenuation α/sub s/ at the w/sub s/ where the stopband begins are specified in filter design, △α/sub s/ usually exceeds the specification by △α/sub s/ due to the necessity that the order n of the filter function be an integer. In this paper, we apply a trade-off method to remove the excess stopband attenuation △α/sub s/ for reducing the value of pole-Q and improving the characteristics of the Chebyshev filter function. We also apply the trade-off method of pole-Q reduction to the modified Chebyshev function, and then the 4 types of function have been analyzed to compare in frequency and time domain characteristics. The trade-off method reduces the pole-Q which influences the filter characteristics to maximum 49.6% without increase of the order n. Thus implies that they have the improved characteristics such as the reduced passband ripple and flatter delay characteristics as compared Chebyshev filter function before trade-off. And the unit step response shows shorter delay time and settling time in time domain performance.

  • PDF

원형도파관을 이용한 Ku-band BPF 설계

  • Jeon, Hyeong-Jun;Gang, Chang-Su
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1273-1278
    • /
    • 2005
  • In this thesis, a 2 stage 6-pole bandpass filter(BPF) is designed and implemented by using triple-mode cavity for satellite payload system. The BPF has a 100MHz bandwidth at the center frequency of 14.5GHz(Ku-band) and the response of the filter is the Chebyshev function. The cavity filter uses two orthogonal $TE_{113}$ modes and one $TM_{012}$ mode. The coupling between the adjacent cavityes(intercavity coupling) results in a Chebyshev response and is accomplished by only H-filed component of TE modes. The size and location of intercavity slot is determined by the coupling equation from E- and H-field of TE and TM resonant modes in circular cavity. The 2-stage 6-pole triple-mode cavity BPF has the insertion loss of 2.4dB and the reflection loss of 15dB in the passband. The triple-mode BPF proposed in this thesis can be used as channel filters for satellite payload system and can minimize filter assembly in general wireless communication system.

  • PDF

The Design of Ku-Band Cavity BPF (Ku-Band Cavity BPF설계)

  • Jeon, Hyung-Joon;Kang, Chang-Soo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.4
    • /
    • pp.69-76
    • /
    • 2005
  • In this paper, a 2 stage 6-pole bandpass filter(BPF) is designed and implemented by using triple-mode cavity for satellite payload system. The BPF has a 100MHz bandwidth at the center frequency of 14.5GHz(Ku-band) and the response of the filter is the Chebyshev function. The cavity filter uses two orthogonal $TM_{113}$ modes and one $TM_{012}$ mode. The coupling between the adjacent cavityes(intercavity coupling) results in a Chebyshev response and is accomplished by only H-filed component of If modes. The size and location of intercavity slot is determined by the coupling equation from E-and H-field of TE and TM resonant modes in circular cavity. The 2-stage 6-pole triple-mode cavity BPF has the insertion loss of 2.4dB and the reflection loss of 15dB in the passband. The triple-mode BPF proposed in this thesis can be used as channel filters for satellite payload system and can minimize filter assembly in general wireless communication system.

Seismic response of active or semi active control for irregular buildings based on eigenvalues modification

  • Pnevmatikos, Nikos G.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.647-664
    • /
    • 2014
  • A reduction of the response of irregular structures subjected to earthquake excitation by control devices equipped by suitable control algorithm is proposed in this paper. The control algorithm, which is used, is the pole placement one. A requirement of successful application of pole placement algorithm is a definition-selection of suitable poles (eigen-values) of controlled irregular structures. Based on these poles, the required action is calculated and applied to the irregular structure by means of control devices. The selection of poles of controlled irregular structure, is a critical issue for the success of the algorithm. The calculation of suitable poles of controlled irregular structure is proposed herein by the following procedure: a fictitious symmetrical structure is considered from the irregular structure, adding vertical elements, such as columns or shear walls, at any location where is necessary. Then, the eigen-values of symmetrical structure are calculated, and are forced to be the poles of irregular controlled structure. Based on these poles and additional damping, the new poles of the controlled irregular structure are calculated. By pole placement algorithm, the feedback matrix is obtained. Using this feedback matrix, control forces are calculated at any time during the earthquake, and are applied to the irregular structure by the control devices. This procedure results in making the controlled irregular structure to behave like a symmetrical one. This control strategy can be applied to one storey or to multi-storey irregular buildings. Furthermore, the numerical results were shown that with small amount of control force, a sufficient reduction of the response of irregular buildings is achieved.

A New Type of 5-Pole Low Pass Filter Using Defected Ground Structure (결함 접지 구조를 이용한 새로운 5-단 저역 통과 여파기)

  • Lim Jong-Sik;Kim Chul-Soo;Ahn Dal;Jeong Yong-Chae;Nam Sangwook;Kim Kwangsoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.594-602
    • /
    • 2005
  • In this paper, a new type of 5-pole low pass filter(LPF) having defected ground structure(DGS) and very wide transmission line elements is proposed. The previously presented design method of 3-stage LPF using DGS is generalized to design N-pole LPFs for $N\geq5$. As an example, a 5-pole LPF having DGS is designed and measured. The accurate curve-fitting method to determine the series inductors in the prototype filter, and ultimately the size of DGS is described. The proposed 5-pole LPF has transmission line elements with a very low impedance to realize the required shunt capacitance instead of open stubs. Therefore, open stub. Therefore, open stub, Tee-junction, Cross-junction, and high impedance line are not required for the proposed LPF, while they all have been essential in conventional LPFs.