• Title/Summary/Keyword: 6 MV photon

Search Result 234, Processing Time 0.02 seconds

A Study on Developing Customized Bolus using 3D Printers (3D 프린터를 이용한 Customized Bolus 제작에 관한 연구)

  • Jung, Sang Min;Yang, Jin Ho;Lee, Seung Hyun;Kim, Jin Uk;Yeom, Du Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.61-71
    • /
    • 2015
  • Purpose : 3D Printers are used to create three-dimensional models based on blueprints. Based on this characteristic, it is feasible to develop a bolus that can minimize the air gap between skin and bolus in radiotherapy. This study aims to compare and analyze air gap and target dose at the branded 1 cm bolus with the developed customized bolus using 3D printers. Materials and Methods : RANDO phantom with a protruded tumor was used to procure images using CT simulator. CT DICOM file was transferred into the STL file, equivalent to 3D printers. Using this, customized bolus molding box (maintaining the 1 cm width) was created by processing 3D printers, and paraffin was melted to develop the customized bolus. The air gap of customized bolus and the branded 1 cm bolus was checked, and the differences in air gap was used to compare $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$ and $V_{95%}$ in treatment plan through Eclipse. Results : Customized bolus production period took about 3 days. The total volume of air gap was average $3.9cm^3$ at the customized bolus. And it was average $29.6cm^3$ at the branded 1 cm bolus. The customized bolus developed by the 3D printer was more useful in minimizing the air gap than the branded 1 cm bolus. In the 6 MV photon, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 102.8%, 88.1%, 99.1%, 95.0%, 94.4% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 101.4%, 92.0%, 98.2%, 95.2%, 95.7%, respectively. In the proton, at the customized bolus, $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of GTV were 104.1%, 84.0%, 101.2%, 95.1%, 99.8% and the $D_{max}$, $D_{min}$, $D_{mean}$, $D_{95%}$, $V_{95%}$ of branded 1cm bolus were 104.8%, 87.9%, 101.5%, 94.9%, 99.9%, respectively. Thus, in treatment plan, there was no significant difference between the customized bolus and 1 cm bolus. However, the normal tissue nearby the GTV showed relatively lower radiation dose. Conclusion : The customized bolus developed by 3D printers was effective in minimizing the air gap, especially when it is used against the treatment area with irregular surface. However, the air gap between branded bolus and skin was not enough to cause a change in target dose. On the other hand, in the chest wall could confirm that dose decrease for small the air gap. Customized bolus production period took about 3 days and the development cost was quite expensive. Therefore, the commercialization of customized bolus developed by 3D printers requires low-cost 3D printer materials, adequate for the use of bolus.

  • PDF

Treatment Result of Ovarian Dysgerminoma (난소 미분화배세포종에 대한 방사선치료 결과)

  • Shin Seong Soo;Park Suk Won;Shin Kyung Hwan;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.379-385
    • /
    • 1997
  • Purpose : Ovarian dysgerminoma is a highly radiosensitive malignant tumor occurring in young age group. The conventional treatment was total abdominal hysterectomy and bilateral salpingo-oophorectomy followed by radiotherapy. We retrospectively analyzed the treatment results of Patients who had received radiotherapy in the era before chemotherapy was widely used. Material and Method : Twenty two patients with ovarian dysgerminoma were treated at the Department of Therapeutic Radiology, Seoul National University Hospital between August, 1980 and May, 1991. Four patients were excluded from this study, because three patients received incomplete treatment and one received combined chemotherapy. Sixteen patients received postoperative radiotherapy and two patients had radical radiotherapy as tumor was unresectable. Median follow-up period was 99 months (range, 51-178) Median age was 22 years (range, 11-42). Among the postoperatively treated patients, three Patients were in stage IA, eight in stage IC, two in stage II, and three in stage III. One patient had Turner's syndrome. Radiotherapy was performed with high energy photon (telecobalt unit or linear accelerator, either 6MV or 10MV), The radiation dose to the whole abdomen was 1950-2100cGy (median, 2000) and 1050-2520cGy was added to the whole pelvis, the total dose to the whole pelvis was 3000-4500cGy (median, 3500). Prophylactic Paraaortic area irradiation was done in six Patients (dose range, 900-1500cGy). One patient who had positive Paraaortic node, received radiation dose of 1620cGy, followed by additional 900cGy to the gross mass with shrinking field. Total dose to the paraaortic node was 4470cGy. Six patients, including one who had paraaortic node metastasis, received Prophylactic irradiation to mediastinum and supraclavicular area (2520cGy). Of the two patients with unresectable tumors who received radical radiotherapy, one was in stage III and the other was in stage IV with left supraclavicular lymph node metastasis. The stage III patient received radiation to the whole abdomen (2000cGy), followed by boost to whole pelvis (2070cGy) and paraaortic area (2450cGy). Stage IV patient received radiation to the whole abdomen (2000cGy), followed by radiation to the whole pelvis and paraaortic area (2400cGy), mediastinum (2520cGy) , and left supraclavicular area (3550cGy) .Results : The 5 year local control rate was $100\%$ in patients who received postoperative adiuvant radiotherapy after total abdominal hysterectomy and bilateral salpingo-oophorectomy. Only one patient in stage III who did not receive prophylactic irradiation to mediastinum developed mediastinal metastasis. but was salvaged by chemotherapy. So. the 5 year overall survival rate uras also $100\%$. Two patients who received radiation only, are alive without disease at 112 and 155 months. Conclusion : Postoperntive adjuvant radiotherapy as well as radical radiotherapy in unresectable ovarian dysgerminoma was very effective. aut chemotherapy is also an effective treatment modality We now recomrneifd chemotherapy for Patients who need to save their ovarian functien and reserve radiotherapv fov chemo-resistant tumor or recurrence alter che motherapy.

  • PDF

Evaluation of superficial dose for Postmastectomy using several treatment techniques (유방전절제술을 시행한 환자에서 치료기법에 따른 피부선량 평가)

  • Song, Yong Min;Choi, Ji Min;Kim, Jin Man;Kwon, Dong Yeol;Kim, Jong Sik;Cho, Hyun Sang;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.225-232
    • /
    • 2014
  • Purpose : The purpose of this study was to evaluate the surface and superficial dose for patients requiring postmastectomy radiation therapy(PMRT) with different treatment techniques. Materials and Methods : Computed tomography images were acquired for the phantom(I'mRT, IBA) consisting of tissue equivalent material. Hypothetical chestwall and lung were outlined and modified. Five treatment techniques(Wedged Tangential; WT, 4-field IMRT, 7-field IMRT, TOMO DIRECT, TOMO HELICAL) were evaluated using only 6MV photon beam. GafChromic EBT3 film was used for dose measurements at the surface and superficial dose. Surface dose profiles around the phantom were obtained for each treatment technique. For superficial dose measurements, film were used inside the phantom and analyzed superficial region for depth from 1-6mm. Results : TOMO DIRECT showed the highest surface dose by 47~70% of prescribed dose, while 7-field IMRT showed the lowest by 35~46% of prescribed dose. For the WT, 4-field IMRT and 7-field IMRT, superficial dose were measured over 60%, 70%, and 80% for 1mm, 2mm, and 5mm depth, respectively. In case of TOMO DIRECT and TOMO HELICAL, over 75%, 80%, and 90% of prescribed dose was measured, respectively. Surface and superficial dose range were uniform in overall chestwall for the 7-field IMRT and TOMO HELICAL. In contrast, Because of the dose enhancement effect with oblique incidence, The dose was gradually increased toward the obliquely tangential angle for the WT and TOMO DIRECT. Conclusion : For PMRT, TOMO DIRECT and TOMO HELICAL deliver the higher surface and superficial doses than treatment techniques based linear accelerator. It showed adequate dose(over 75% of prescribed dose) at 1mm depth in skin region.

The Role of Postoperative External Irradiation for the Incompletely Resected Meningiomas (불완전절제된 수막종에서 수술 후 방사선치료의 역할)

  • Kim Tae-Hyun;Yang Dae-Sik;Kim Chul-Young;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2000
  • Purpose : The aim of this study is to look for the possible efficacy of postoperative external irradiation for incompletely resected meningiomas. Methods and Materials : From August 198: to January 1997, forty-four patients with intracranial meningioma were treated by postoperative external irradiation. Of the 44 meningiomas, 18 transitional, 13 meningotheliomatous, 6 hemangiopericytic, 4 atypical, 2 fibroblastic and 1 malignant meningioma were identified. We classified all patients into two groups by the histology. The benign group was consisted of the meningotheliomatous, transitional and fibroblastic types. The malignant group was consisted of the atypical, hemangiopericytic and malignat types. In the means of surgery, 37 patients were resected incompletely and 7 patients were managed by biopsy only. After surgery, all patients were received postoperative external irradiation. Radiotherapy was deliverd using Co-60 or 4 MV photon beam to a total dose of 50 to 65 Gy (mean dose 57.4 Gy) with a 1.8 to 2 Gy per fraction. The median follow-up was 48 months (range : 21 $\~$ 101 months). Multivariate analysis of the Influence by age, sex, location, histology and radiation dose on local control has been done using Cox's proportional hazard model. Results : 5-year local control rate was 93.8$\%$ for the benign histology and 51.8$\%$ for the malignant histology (p=0.0110) and overall local control rate at 5 years was 87.4$\%$. The analysis of the prognostic factors, such as age, sex, location, and radiation dose were not significant except for the histology. Conclusion : Adjuvant postoperative external irradiation appears to be significantly improved local control in the patients with incompletely resected meningiomas.

  • PDF

Evaluation of Dosimetric Characteristics of Small Field in Cone Versus Square Fields Based on Linear Accelerators(LINAC) for Stereotactic Radiosugery(SRS) (선형가속기를 기반으로 한 뇌정위 방사선 수술 시 전용 콘과 정방형 소조사면의 선량 특성에 관한 고찰)

  • Yoon, Joon;Lee, Gui-Won;Park, Byung-Moon
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • In this paper we evaluated small field dose characteristics of exclusive cone fields versus square fields for stereotactic radiosugery (SRS) which is based on linear accelerators (LINAC). For this test, we used a small beam detector (stereotactic fields detector : SFD) with a 6 MV photon beam and a water phantom system (IBA, Germany). Percentage depth dose (PDD) was measured for different field sets (cones : ${\Phi}1\;cm$, ${\Phi}2\;cm$, ${\Phi}3\;cm$ ; square fields : $1{\times}1\;cm^2$, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$) at a source skin distance (SSD) of 100 cm. We measured the point depths at 1.5 cm, 5 cm, 10 cm, 20 cm, and 30 cm. The output factors were measured under the same geometrical conditions of the PDD and normalized at the maximum dose depth. To analyze the penumbra, we measured the dose profile with 95 cm of SSD, 5 cm of depth for each field sizes (${\Phi}1\;cm$, ${\Phi}3\;cm$, $1{\times}1\;cm^2$, and $3{\times}3\;cm^2$) using SFD. We obtained the values for every 1 mm interval in the physical field (90%) and 0.5 mm interval in the penumbra region (20 to 80%). The PDD variation of exclusive cones and square fields were 4.3 to 7.9% lesser than the standard field size ($10{\times}10\;cm^2$. The variation of PDD was reduced while the field size was increased. To compare the beam quality, we analyzed the $PDD_{20,10}$ and the results showed under the 1% of variations for all experiments except for ${\Phi}1\;cm$ cone and $1{\times}1\;cm^2$ fields. Output factors of exclusive cone were increased 3.1~4.6% than the square fields, and the penumbra region of exclusive cone was reduced 20% as compared to the square fields. As the previous researches report, it is very important for SRS and SFD that precise dosimetry in small beam fields. In this paper, we showed the effectiveness of exclusive cone, compared to square field. And we will study on the various detector characteristics for small beam fields.

Dose Effect of Tissue Compensator for 6 MV X-Ray (두경부 방사선조사시 3차원조직보상체에 의한 피부선량)

  • Lee, Ho-Jun;Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 1992
  • It is ideal thing to compensate tissue deficit without skin contamination in curvatured irradiation field of high energy photon beam. The 3-dimensional compensating technique utilizing tissue equivalent materials to ensure an adequate dose distribution and skin sparing effect was described. This compensator was made of paraffin ($70\%$) and stearin wax ($30\%$) compound. The parameters for evaluation of the effect on skin dose in application of compensator were considered in the size of the field, the thickness of the compensator and the source-to-axis distance. The results are as follows; the skin doses were not changed even though application of the compensator, but depended on the field size and the source-to-axis distance, and the skin doses were only slightly changed within $1\%$ relative errors as increasing the thickness of the compensator in these experiments.

  • PDF

Estimation of Fetal Dose during Radiation Therapy of Pregnant Patient (임산부의 방사선치료 시 태아선량 평가)

  • Jung, Chi-Hoon;Kim, Chan-Yong;Kim, Bo-Gyum;Seo, Suk-Jin;Yoo, Sook-Hyun;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Purpose: To evaluate the effectiveness of a simple and practical shielding device to reduce the fetal dose for a pregnant patient undergoing radiation therapy of brain metastasis. Materials and Methods: The dose to the fetus was evaluated by simulating the treatments using the anthropomorphic phantom. The prescription dose at mid-brain is $300cGy{\times}10$ fractions with 6 MV photon with $18{\times}22cm^2$ field size. The additional shielding devices to reduce the fetal dose are a shielding wall, cerrobend plates and lead (Pb) sheets over acrylic bridge. Various points of measurement with off-field distance were detected by using ion-chamber (30, 40, 50, and 60 cm) with and without the shielding devices and TLD (30, 40, 50, 60, and 70 cm) only with the shielding devices. Results: The doses to the fetus without shielding were 3.20, 3.21, 1.44, 0.90 cGy at the distances of 30, 40, 50, and 60 cm from the treatment field edge. With shielding, the doses were reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy (70 cm). The total dose to the fetus was expected to be under 1 cGy during the entire treatment. Conclusion: The essential point during radiation therapy of pregnant patient would be minimizing the fetal dose. 10 cGy to 20 cGy is the threshold dose for fetal radiation effects. Our newly developed device reduced the fetal dose far below the safe level. Therefore, our additional shielding devices are useful and effective to reduce the fetal dose.

  • PDF

Long-term Results of Radiotherapy for Subfoveal Choroidal Neovascularization (CNV) in Age-related Macular Degeneration (ARMD) (연령관련 황반하 맥락막 신생혈관증에서 방사선의 장기적 치료 결과)

  • Kim, Bo-Kyong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.63-69
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: We performed this prospective randomized study to evaluate the efficacy and the complications of radiotherapy for Subfoveal CNV in ARMD and to compare the treatment results at two dosages (14.4 Gy and 19.8 Gy). $\underline{Materials\;and\;Methods}$: 60 eyes of 55 patients were enrolled, and randomized into 14.4 Gy (31 eyes) or 19.8 Gy (29 eyes) groups. CT was used to plan the radiotherapy. All patients received radiotherapy with a 1.8 Gy daily dose using 4 MV photon. We categorized treatment results as improved, stable, or deteriorated based on visual acuity changes of more than 2 lines on the ETDRS chart. $\underline{Results}$: Median follow-up period was 33.5 months. At 12 months, visual acuity improved in 9 (16.7%), stable in 41 (75.9%), and aggravated in 4 (7.4%) of 54 evaluated eyes. At 24 months, 49 eyes (81.7%) were evaluated. Visual acuity improved in 6 (12.2%), was stable in 33 (67.4%), and deteriorated in 10 (20.4%). At 36 months, 37 eyes were evaluated. Six (16.2%) eyes were improved, 21 (56.8%) stable, and 10 (27.0%) deteriorated. No significant difference in response was observed between the 14.4 Gy and 19.8 Gy groups (Mantel-Haenszel $x^2=0.4756$). The proportion of eyes with a vision of $20/100{\leq}increased$ from 28.3% initially to 32.7% after 24 months of radiotherapy. There were no severe acute or chronic complications. $\underline{Conclusion}$: External beam radiotherapy with doses of 14.4 or 19.8 Gy may be an effective treatment for subfoveal CNV in ARMD. No dose-response relationships with respect to treatment response or toxicity were observed between the 14.4 Gy and 19.8 Gy groups.

Radiation Therapy in Elderly Skin Cancer (노령의 피부암에서 방사선치료)

  • Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.113-117
    • /
    • 2008
  • Purpose: To evaluate the long term results(local control, survival, failure, and complications) after radiation therapy for skin cancer in elderly patients. Material and Methods: The study spanned from January 1990 to October 2002. Fifteen elderly patients with skin cancer were treated by radiotherapy at the Keimyung University Dongsan Medical Center. The age distribution of the patients surveyed was 72 to 95 years, with a median age of 78.8 years. The pathologic classification of the 15 patients included squamous cell carcinoma(10 patients), basal cell carcinoma(3 patients), verrucous carcinoma(1 patient) and skin adnexal origin carcinoma(1 patient). The most common tumor location was the head(13 patients). The mean tumor diameter was 4.9 cm(range 2 to 9 cm). The radiation dose was delivered via an electron beam of 6 to 15 MeV. The dose range was adjusted to the tumor diameter and depth of tumor invasion. The total radiation dose ranged from $50{\sim}80$ Gy(mean: 66 Gy) with a 2 Gy fractional dose prescribed to the 80% isodose line once a day and 5 times a week. One patient with lymph node metastasis was treated with six MV photon beams boosted with electron beams. The length of the follow-up periods ranged from 10 to 120 months with a median follow-up period of 48 months. Results: The local control rates were 100%(15/15). In addition, the five year disease free survival rate(5YDFS) was 80% and twelve patients(80%) had no recurrence and skin cancer recurrence occurred in 3 patients(20%). Three patients have lived an average of 90 months($68{\sim}120$ months) without recurrence or metastasis. A total of 9 patients who died as a result of other causes had a mean survival time of 55.8 months after radiation therapy. No severe acute or chronic complications were observed after radiation therapy. Only minor complications including radiation dermatitis was treated with supportive care. Conclusion: The results suggest that radiation therapy is an effective and safe treatment method for the treatment of skin cancer in elderly patients who achieved a good survival rate and few minor complications.

The Evaluation of the dose calculation algorithm(AAA)'s Accuracy in Case of a Radiation Therapy on Inhomogeneous tissues using FFF beam (FFF빔을 사용한 불균질부 방사선치료 시 선량계산 알고리즘(AAA)의 정확성 평가)

  • Kim, In Woo;Chae, Seung Hoon;Kim, Min Jung;Kim, Bo Gyoum;Kim, Chan Yong;Park, So Yeon;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.321-327
    • /
    • 2014
  • Purpose : To verify the accuracy of the Ecilpse's dose calculation algorithm(AAA:Analytic anisotropic algorithm) in case of a radiation treatment on Inhomogeneous tissues using FFF beam comparing dose distribution at TPS with actual distribution. Materials and Methods : After acquiring CT images for radiation treatment by the location of tumors and sizes using the solid water phantoms, cork and chest tumor phantom made of paraffin, we established the treatment plan for 6MV photon therapy using our radiation treatment planning system for chest SABR, Ecilpse's AAA(Analytic anisotropic algorithm). According to the completed plan, using our TrueBeam STx(Varian medical system, Palo Alto, CA), we irradiated radiation on the chest tumor phantom on which EBT2 films are inserted and evaluated the dose value of the treatment plan and that of the actual phantom on Inhomogeneous tissue. Results : The difference of the dose value between TPS and measurement at the medial target is 1.28~2.7%, and, at the side of target including inhomogeneous tissues, the difference is 2.02%~7.40% at Ant, 4.46%~14.84% at Post, 0.98%~7.12% at Rt, 1.36%~4.08% at Lt, 2.38%~4.98% at Sup, and 0.94%~3.54% at Inf. Conclusion : In this study, we discovered the possibility of dose calculation's errors caused by FFF beam's characteristics and the inhomogeneous tissues when we do SBRT for inhomogeneous tissues. SBRT which is most popular therapy method needs high accuracy because it irradiates high dose radiation in small fraction. So, it is supposed that ideal treatment is possible if we minimize the errors when planning for treatment through more study about organ's characteristics like Inhomogeneous tissues and FFF beam's characteristics.