• Title/Summary/Keyword: 6축

Search Result 1,831, Processing Time 0.033 seconds

Development of Five Axis Laser Cutting System for the Tangent Cutting Solid Freeform Fabrication System (임의형상가공시스템을 위한 레이저 5축 경사절단기 및 궤적생성 알고리즘의 개발)

  • 주영철;엄태준;이차훈;공용해;천인국;김승우;방재철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • A novel Solid Freeform Fabrication System, which makes prototype by cutting tapes at the boundary of object and accumulating the tapes, has been developed. In order to overcome the staircase shape at the surface of prototype, the laser beam is irradiated tangent to the surface. Five axis cutting system and the tangent cutting trajectory generation algorithm have been developed.

  • PDF

Three Axis Disk Spring Damper Containing Wedge System (웻지를 이용한 3축 방향 디스크 스프링 댐퍼에 관한 연구)

  • Choi, Myung-Jin;Jeong, Ji-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.1-8
    • /
    • 2009
  • This study pertains to damping device to reduce vibrational responses and shocks in multi-directions. To enhance the capability of disk spring damper which works for vertical vibration and shock, a multi-directional damper is proposed, which contains wedge system as well as disk spring stack. Wedge system converts horizontal load into vertical load. A mathematical model is proposed and investigated for the nonlinear behaviors of the disc spring damper containing wedge system. The results accord with the experimental results. Equivalent viscous damping in vertical and horizontal directions are found based upon energy dissipated.

  • PDF

Development of 6-axis force/moment sensor for an intelligent robot's foot (지능형 로봇 발을 위한 6 축 힘/모멘트센서 개발)

  • Kim, Gab-Soon;Shin, Hyi-Jun;Hu, Duk-Chan;Yoon, Jung-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1097-1102
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor for an intelligent robot's foot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to a humanoid robot's foot(ankle). They in the published paper already have some disadvantage in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to be gotten similar the rated output under each rated load. So, the sensing elements of the 6-axis force/moment sensor should get lots of design variables. Also, the size of 6- axis force/moment sensor is very important for mounting to robot's foot. In this paper, a 6-axis force/moment sensor for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using FEM (Finite Element Method) analysis. Then, the 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

  • PDF

Development of Humanoid Robot's Intelligent Foot with Six-axis Force/Moment Sensors (6축 힘/모멘트센서를 가진 인간형 로봇의 지능형 발 개발)

  • Kim, Gab-Soon;Kim, Hyeon-Min;Yoon, Jung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.96-103
    • /
    • 2009
  • This paper describes a humanoid robot's intelligent foot with two six-axis force/moment sensors. The developed humanoid robots didn't get the intelligent feet for walking on uneven surface safely. In order to walk on uneven surface safely, the robot should measure the reaction forces and moments applied on the sales of the feet, and they should be controlled with the measured the forces and moments. In this paper, an intelligent foot for a humanoid robot was developed. First, the body of foot was designed to be rotated the toe and the heel to all directions, second, the six-axis force/moment sensors were manufactured, third, the high-speed controller was manufactured using DSP(digital signal processor), fourth, the humanoid robot's intelligent foot was manufactured using the body of foot, two six-axis force/moment sensors and the high-speed controller, finally, the characteristic test of the intelligent foot was carried out. It is thought that the foot could be used for a humanoid robot.

Design of a Six-Axis Force/Moment Sensor using Analytical Method for Humanoid Robot Foot Module (인간형 로봇의 발 모듈 개발을 위한 분석적 방법의 6 축 힘 / 모멘트 센서 설계)

  • Yuan, Chao;Lim, Dong Hwan;Luo, Lu Ping;Han, Chang Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.4
    • /
    • pp.359-367
    • /
    • 2015
  • The forces and moments exerted on humanoid robot foot are important information for controlling or monitoring the robot. Multi-axis force/moment sensor can be installed under humanoid robot foot to measure forces and moments. The sensor should have large stiffness to support the robot weight and small size not to disturb the motion of the robot. In this paper, we designed a 6-aixs force/moment sensor which has good accuracy, large measuring range, and new compact structure. In addition, the proposed sensor is evaluated using analytical method and FEM(Finite Elements Method) method. Finally, it turned out that it has good performance.

Estimation of Sensitivity Axis Offset of an Accelerometer for Accurate Measurement of the 6 DOF Human Head Motion (인체 머리부 6 자유도 운동 측정의 신뢰성 향상을 위한 가속도계 감도축의 옵셋(offset) 추정)

  • Lee, Jeung-Hoon;Kim, Kwang-Joon;Jang, Han-Kee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.905-912
    • /
    • 2008
  • Notion sickness is well known to be caused by long time exposure to the very low frequency motion in the multiple axes of human body Since the vestibular system for the perception of low frequency motion is located in the head, accurate measurement of 6 degree of freedom head motion is of great importance. In this study, the measurement system consisting of a safety helmet and 9 translational accelerometers was constructed for the estimation of 3 translational and 3 rotational motions of human head. Since estimation errors of 3 rotational components can be significantly magnified even by small offset of the sensitivity axis from the geometric center of an accelerometer, accurate measurement of sensitivity axis must be preceded. The method for accurate estimation of the offset was proposed, and the effect of offset on the estimation of angular acceleration was investigated.

Design and evaluation of binocular type six-component load cell by using experimental technique (실험계획법을 이용한 쌍안경식 6축 로드셀의 설계 및 상호간섭 오차 평가)

  • Kang, Dae-Im;Kim, Gab-Sun;Jeong, Su-Yeon;Joo, Jin-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1921-1930
    • /
    • 1997
  • This paper presents the effective technique to design a six-axis load cell by using experimental design with an orthogonal array. A binocular structure is used as a basic sensing element for a load cell instead of the parallel plate structure. The finite element method is adopted to obtain strain distributions of the sensing element, and by doing the analysis of variances, its results are utilized in determining the factor which is more influential to the output strain. Calibration test results show that the developed six-axis loa cell with the maximum capacities of 196 N in forces and 19.6 N. m in moments is evaluated to be useful with the coupling error less than 2.5%.

Aerodynamic and Structural Design of 6kW Class Vertical-Axis Wind Turbine (6kW급 수직축 풍력발전기 형상 및 구조설계)

  • Kim, Dong-Hyun;Choi, Hyun-Chul;Lee, Jong-Wook;Ryu, Gyeong-Joong;Kim, Sung-Bok;Kim, Kwang-Won;Nam, Hyo-Woo;Lee, Myoung-Goo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • In this study, the design and verification of 6 kW class lift-type vertical-axis wind turbine (VAWT) has been conducted using advanced CAE technique based on computational fluid dynamics (CFD), finite element method (FEM), and computational structural dynamics (CSD). Designed aerodynamic performance of the VAWT model is tested using unsteady CFD method. Designed structural safety is also tested through the evaluation of maximum induced stress level and resonance characteristics using FEM and CSD methods. It is importantly shown that the effect of master eccentricity due to rotational inertia needs to be carefully considered to additionally investigate dynamic stress and deformation level of the designed VAWT system.

Structure Dynamic Analysis of 6kW Class Vertical-Axis Wind Turbine with Tower (타워를 포함한 6kW급 수직축 풍력발전기 구조진동해석)

  • Kim, Dong-Hyun;Ryu, Gyeong-Joong;Kim, Yo-Han;Kim, Sung-Bok;Kim, Kwang-Won;Nam, Hyo-Woo;Lee, Myoung-Goo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.663-670
    • /
    • 2011
  • In this study, the design and verification of 6kW class lift-type vertical-axis wind turbine (VAWT) has been conducted using advanced CAE technique based on computational fluid dynamics (CFD), finite element method (FEM), and computational structural dynamics (CSD). Designed aerodynamic performance of the VAWT model is tested using unsteady CFD method. Designed structural safety is also tested through the evaluation of maximum induced stress level and resonance characteristics using FEM and CSD methods. It is importantly shown that the effect of master eccentricity due to rotational inertia needs to be carefully considered to additionally investigate dynamic stress and deformation level of the designed VAWT system.

  • PDF

Effect of Inhaled Fluticasone Propionate on Hypothalamic-Pituitary-Adrenal Axis in Bronchial Asthma Patient (기관지 천식환자에서 Fluticasone Propionate 흡입제가 Hypothalamic-Pituitary-Adrenal Axis에 미치는 영향)

  • Hwang, Jun-Kyu;Lee, Ho-Meong;No, Yang-Won;Park, Gye-Young;Park, Chong-Wung;Park, Jae-Kyung;Jeong, Seong-Hwan;Nam, Gui-Hyun;Kim, Hong-Kyu;Park, Hye-Young;Kang, Moon-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.1
    • /
    • pp.25-34
    • /
    • 2001
  • Background : Inhaled glucocorticoids are the medical treatment of choice in asthma patients. Fluticasone propionate is one of the most effective inhaled corticosteroids and has been reported to have minimal effect on the hypothalamic-pituitary-adrenal axis at the recommended dose. However, reports of long-term trials characterizing their systemic safety with chronic use are rare. This study was designed to evaluate the long-term safety of inhaled fluticasone propionate to the hypothalamic-pituitary-adrenal axis. Method : This study was conducted on 21 patients to evaluate the adrenal response to rapid ACTH stimulation test after 6 months of treatment with fluticasone propionate from $200\;{\mu}g$ to $750\;{\mu}g$ daily. The serum cortisol levels was measured to assess its effect on the hypothalamic-pituitary-adrenal axis just prior to the injection, at 30 minutes and 60 minutes after an intramuscular injection of synthetic ACTH. Result : The mean dose of inhaled fluticasone propionate was $355\;{\mu}g$ per day(SD=$174\;{\mu}g$, range=$200\;{\mu}g$ to $750\;{\mu}g$). The mean serum cortisol levels of the patients was $11.0\;{\mu}g/d{\ell}$(SD=$6.4\;{\mu}g/d{\ell}$) prior to the injection, $20.0\;{\mu}g/d{\ell}$ (SD=$7.7\;{\mu}g/d{\ell}$) after 30 minutes, and $23.0\;{\mu}g/d{\ell}$(SD=$6.3\;{\mu}g/d{\ell}$) after 60 minutes. Sixteen patients of the 21 patients had a normal response(> $18\;{\mu}g/d{\ell}$), and 5 out of the 21 patients had serum cortisol levels below the normal range after the rapid ACTH stimulation test. Conclusion: Adrenal suppression occurred in 5 out of 21 patients with 6 months treatment with inhaled fluticasone propionate.

  • PDF