• Title/Summary/Keyword: 6개 지점

Search Result 1,203, Processing Time 0.033 seconds

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF

Evaluation of Dark Spots Formated on the High Temperature Metal Filter Elements (고온 금속필터 element 표면에 생성된 반점에 대한 평가)

  • Park, Seung-Chul;Hwang, Tae-Won;Moon, Chan-Kook
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Metal filter elements were newly introduced to the high temperature filter(HTF) system in the low- and intermediate-level radioactive waste vitrification plant. In order to evaluate the performance of various metal materials as filter media, elements made of AISI 316L, AISI 904L, and Inconel 600 were included to the test set of filter elements. At the visual inspection to the elements performed after completion of each test, a few dark spots were observed on the surface of some elements. Especially they were found much more at the AISI 316L elements than others. To check the dark spots are the corrosion phenomena or not, two kinds of analyses were performed to the tested filter elements. Firstly, the surfaces or the cross sections of filter specimens cut out from both normal area and dark spot area of elements were analyzed by SEM/EDS. The results showed that the dark spots were not evidences of corrosion but the deposition of sodium, sulfur and silica compounds volatilized from waste or molten glass. Secondly, the ring tensile strength were analyzed for the ring-shape filter specimens cut out from each kind of element. The result obtained from the strength tested showed no evidence of corrosion as well. Conclusionally, depending on the two kinds of analysis, no evidences of corrosion were found at the tested metal filter elements. But the dark spots formed on the surface could reduce the effective filtering area and increase the overall pressure drop of HTF system. Thus, continuous heating inside filter housing up to dew point will be required normally. And a few long-period test should be followed for the exact evaluation of corrosion of the metal filter elements.

  • PDF

Soil Environmental Characteristics Assessment of the Namsan Park in Seoul (서울남산의 토양환경특성 평가)

  • Kim, Ik-Soo;Lee, Jai-Young;Kim, Gyeo-Bung;Eom, Seok-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.22-29
    • /
    • 2008
  • To understand environmental characteristics and contamination assessment of the Namsan Park soil in Seoul, we divided the Namsan map into 33 sectors and sampled mixed soil in depth 0${\sim}$15 cm, in 5${\sim}$10 points at the sites. We analyzed soil samples collected at 21 sectors twice on May and September. The results were as follows. The hue color ranges of the Namsan soil were 2.5YR${\sim}$10YR, the value ranges were 1${\sim}$4, the water rates were 3.1${\sim}$22.3 and the Ignition losses were 3.4${\sim}$10.4%. The average concentration of Cu and Pb were determined 3.374 and 15.000 mg/kg, Cd and As showed very low level. The mean concentrations of Zn and Ni were showed 103.290 and 11.649 mg/kg and this amount is not different from the nationalwide mean in 2005. The mean pH showed 5.41. The Zn, Ni and Cd in the soil of the circular road of Namsan showed 1.33, 1.48, 1.46 times higher than the other sector of the Namsan soil. The corelation coefficient between water rate and ignition loss were 0.720 and the correlation coefficient between Cu and Pb, Cu and Zn showed 0.827, 0.694 respectively. There was weak corelationship between pH and Zn. The Uniformity coefficient (Uc) of all the survey sites was determined below 5 in the range of 1.5${\sim}$4.4.

Analysis on the Influence of Moment Distribution Shape on the Effective Moment of Inertia of Simply Supported Reinforced Concrete Beams (철근콘크리트 단순보의 유효 단면2차모멘트에 대한 모멘트 분포 형상의 영향 분석)

  • Park, Mi-Young;Kim, Sang-Sik;Lee, Seung-Bae;Kim, Chang-Hyuk;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.93-103
    • /
    • 2009
  • The concept of the effective moment of inertia has been generally used for the deflection estimation of reinforced concrete flexural members. The KCI design code adopted Branson's equation for simple calculation of deflection, in which a representative value of the effective moment of inertia is used for the whole length of a member. However, the code equation for the effective moment of inertia was formulated based on the results of beam tests subjected to uniformly distributed loads, which may not effectively account for those of members under different loading conditions. Therefore, this study aimed to verify the influences of moment shapes resulting from different loading patterns by experiments. Six beams were fabricated and tested in this study, where primary variables were concrete compressive strengths and loading distances from supports, and test results were compared to the code equation and other existing approaches. A method utilizing variational analysis for the deflection estimation has been also proposed, which accounts for the influences of moment shapes to the effective moment of inertia. The test results indicated that the effective moment of inertia was somewhat influenced by the moment shape, and that this influence of moment shape to the effective moment of inertia was not captured by the code equation. Compared to the code equation, the proposed method had smaller variation in the ratios of the test results to the estimated values of beam deflections. Therefore, the proposed method is considered to be a good approach to take into account the influence of moment shape for the estimation of beam deflection, however, the differences between test results and estimated deflections show that more researches are still required to improve its accuracy by modifying the shape function of deflection.

Statistical Optimization of Production Medium for Enhanced Production of Itaconic Acid Biosynthesized by Fungal Cells of Aspergillus terreus (Aspergillus terreus에 의해 생합성되는 이타콘산의 생산성 증가를 위한 통계적 생산배지 최적화)

  • Jang, Yong-Man;Shin, Woo-Shik;Lee, Do-Hoon;Kim, Sang-Yong;Park, Chul-Hwan;Jeong, Yong-Seob;Chun, Gie-Taek
    • KSBB Journal
    • /
    • v.24 no.1
    • /
    • pp.30-40
    • /
    • 2009
  • Statistical optimization of the production medium was carried out in order to find an optimal medium composition in itaconic acid fermentation process. Itaconic acid utilized in the manufacture of various synthetic resins is a dicarboxylic acid biosynthesized by fungal cells of Aspergillus terreus in a branch of the TCA cycle via decarboxylation of cis-aconitate. Through OFAT (one factor at a time) experiments, six components (glucose, fructose, sucrose, soluble starch, soybean meal and cottonseed flour) were found to have significant effects on itaconic production among various carbon- and nitrogen-sources. Hence, using these six factors, interactive effects were investigated via fractional factorial design, showing that the initial concentrations of sucrose and cottonseed flour should be high for enhanced production of itaconic acid. Furthermore, through full factorial design (FFD) experiments, negative effects of $KH_2PO_4$ and $MgSO_4$ on itaconic acid biosynthesis were demonstrated, when excess amounts of the each component were initially added. Based on the FFD analysis, further statistical experiments were conducted along the steepest ascent path, followed by response surface method (RSM) in order to obtain optimal concentrations of the constituent nutrients. As a result, optimized concentrations of sucrose and cottonseed flour were found to be 90.4g/L and 53.8g/L respectively, with the corresponding production level of itaconic acid to be 4.36 g/L (about 7 fold higher productivity as compared to the previous production medium). From these experimental results, it was assumed that optimum ratio of the constituent carbon (sucrose) and nitrogen (cottonseed flour) sources was one of the most important factors for the enhanced production of itaconic acid.

Hypofractionated Radiation Therapy for Early Glottic Cancer - Preliminary Results - (초기 성문암 환자에서의 소분할 조사법을 이용한 방사선치료 - 예비적 결과 -)

  • Wu Hong-Gyun;Hong Semie;Shin Seong Soo;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.301-305
    • /
    • 2001
  • Purpose : This study was peformed for the evaluation of the feasibility and toxicity of hypofractionated radiation therapy for early glottic cancer Methods and Materials : From February 1999 to February 2000, 20 patients with Histologically confirmed Stage I, II glottic cancer were enrolled into this study. There were 18 males and 2 females, the median age of the patients was 59 years. The distribution of stage distribution was as fellows; T1aN0-16 patients, T1bN0-1 patient, T2N0-3 patients. Eighteen patients underwent laryngomicroscopic biopsy only, and two patients underwent laser cordectomy. All patients received radical radiation therapy (2.5 Gy per fraction, 24 fractions, total 60 Gy). Median duration of treatment was 36 days (range $31\~45\;days$). Results : Radiation therapy were well tolerated. Most common acute reactions were odynophagia and hoarseness, and these reactions resolved after radiation therapy. There were one case of RTOG grade 3 odynophagia $(5\%)$, six cases of grade 3 hoarseness $(30\%)$. Response of radiation therapy was evaluated one month after completion of treatment. All patients revealed complete response. During follow up, total three cases of treatment failure were detected. two cases were local recurrence in 10 and 13 months of radiation therapy and one case was local recurrence and distant metastasis in 2 months of radiation therapy. Conclusion : This hypofractionated radiation therapy schedule was feasible and effective for control of early glottic cancer But longer follow up time would be required to assess the long-term disease control and the late complication by shortening radiation therapy duration.

  • PDF

Dynamics of Inorganic Nutrients and Phytoplankton in Shihwa Reservoir (시화호에서 무기영양염과 식물플랑크톤의 동태)

  • Kim, Dong-Sup;Cho, Kyung-Je;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.2 s.90
    • /
    • pp.109-118
    • /
    • 2000
  • The dynamics of inorganic nutrients and phytoplankton population were examined at eight stations of Shihwa Reservoir, which situated near the cities newly constructed and the industrial complex of West-sea in Korea, from January to December 1999. Among environmental factors, average concentration of $NH_4$, SRP and SRSi were $522.7\;{\mu}g\;N/l$, $9.8\;{\mu}g\;N/l$ and $0.26\;{\mu}g\;Si/l$, respectively. Water quality was extremely deteriorated by a great amount of pollutants load into inner reservoir after the event of rainfall. Nutrients concentration was suddenly decreased toward the lower part. While $NO_3$ concentration did not much varied among stations, but it was relatively high in winter season. Chlorophyll-a concentration was high at the upper part of the reservoir, with average of $37.2\;{\mu}/l$, and closely related to the fluctuation of $NH_4$, SRP and SRSi concentrations. The phytoplankton development in the water column was dominated by diatom (autumn), prasinoid (winter) and dinoflagellate (summer). Dominant phytoplankton were composed to Skeletonema costatum of diatom, Prorocentrum minimum of dinoflagellate, Chroomonas spp. of cryptomonad, Eutreptiella gymnastica of euglenoid and Pyramimonas spp. of prasinoid. The large bloom of phytoplankton at the upper zone of the Shihwa Reservoir after inflow of a seawater were consistently observed. In consequence, water quality management of the inlet stream was assessed to be very important and urgent.

  • PDF

Ventilation at Supra-Optimal Temperature Leading High Relative Humidity Controls Powdery Mildew, Silverleaf Whitefly, Mite and Inhibits the Flowering of Korean Melon in a Greenhouse Cultivation (참외 시설 재배 시 고온에서의 환기 처리에 의한 상대습도 상승과 흰가루병, 담배가루이, 응애 방제 및 개화 억제)

  • Seo, Tae Cheol;Kim, Jin Hyun;Kim, Seung Yu;Cho, Myeong Whan;Choi, Man Kwon;Ryu, Hee Ryong;Shin, Hyun Ho;Lee, Choung Keun
    • Journal of Bio-Environment Control
    • /
    • v.31 no.1
    • /
    • pp.43-51
    • /
    • 2022
  • This study was conducted to investigate the effect of ventilation at high temperature on the control of powdery mildew, silverleaf whitefly two-spotted spider mite occurred at Korean melon cultivation greenhouse, and on leaf rolling and flowering of the plant in summer season. 'Alchanggul' grafted onto 'Hidden Power' rootstock was planted on soil bed with the distance of 40 cm. Three ventilation temperatures of 45℃, 40℃, and 35℃ as set points were compared. Ventilation treatment was done by control of side window operation from 18th June to 13th July when silverleaf whitefly, mite, and powdery mildew were occurred in all greenhouses. The temperature inside greenhouse was increased up to the set temperature point on sunny days and maintained for about 9 hours with high relative humidity at 45℃ condition. The differences of day maximum air temperature and day minimum RH were the highest at 45℃ treatment. After 11 days of treatments, the damage by powdery mildew and two-spotted spider mite was almost recovered at 45℃ treatment but not at 40 and 35℃. The population of silverleaf whitefly and two-spotted spider mite were significantly decreased at 45℃ treatment at 14 days after treatment, while powdery mildew symptom was not significantly decreased. Leaf rolling was observed at high temperature but not severe at 45℃ treatment. After 26 days of treatments, female flowers did not bloom at all at 45℃ treatment, and the number of male flowers was 1.2 among 15 nodes of newly grown shoots. As the result, it indicates that ventilation at the high temperature of 45℃ for about 2 to 3 weeks can be an applicable method to control above mentioned pests and disease, and to recover the vegetative growth of Korean melon by reducing flowering of the plant.

Bioacoustics and Habitat Environment Analysis of Cicadas in Taebaeksan National Park (태백산국립공원에 서식하는 매미류의 생물음향 및 서식환경 분석)

  • Kim, Yoon-Jae;Jung, Tae-Jun;Ki, Kyong-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.6
    • /
    • pp.664-676
    • /
    • 2019
  • This study aimed to analyze the bioacoustics and habitat environment of the cicadas inhabiting Taebaeksan National Park, an sub-alpine region in Korea. The mating calls of the cicadas were recorded for approximately 3 months, between July and September of 2018. The recording devices were installed in Daedeoksan valley and Baekcheon valley, inside Taebaeksan National Park, and the sounds were recorded 24 hours a day. In order to obtain the habitat distribution data of the cicadas, the sounds were recorded from 111 spots located in the Taebaeksan National Park trail in August 2018. The daily weather data was obtained from the Taebaek city weather center. The results of the study demonstrated that 5 species of cicadas inhabit Taebaeksan National Park, namely, Leptosemia takanonis, Lyristes intermedius, Kosemia yezoensis, Hyalessa fuscata, and Meimuna opalifera. The time of appearance for L. takanonis was early July to mid-July, and that for L. intermedius, K. yezoensis, H. fuscata, and M. opalifera was mid-July to early September. Analysis of the circadian rhythm revealed that L. intermedius, K. yezoensis, and H. fuscata started producing mating calls between 6:00 and 7:00, which ended at around 19:00 for all the three species. The peak time for producing mating calls was 11:00 for L. intermedius, 12:00 for H. fuscata, and around 13:00 to 14:00 for K. yezoensis. The environmental factors influencing the mating calls of the cicadas inhabiting Taebaeksan National Park were analyzed by logistic regression. The results showed that the probability of producing mating calls increased by 1.192 and 1.279 times in L. intermedius and K. yezoensis, respectively, when the average temperature increased by one degree. When the duration of sunlight increased by one hour, the probability of producing mating calls increased by 4.366 and 2.624 times in L. intermedius and H. fuscata, respectively. Analysis of the interspecific effects revealed that when H. fuscata produced a single mating call, the probability of producing mating calls increased by 14.620 and 2.784 times in L. intermedius and K. yezoensis, respectively. When K. yezoensis and L. intermedius produced mating calls, the probability of producing mating calls in H. fuscata increased by 11.301 and 2.474 times, respectively. L. intermedius and K. yezoensis did not have any effects on each other with respect to the production of mating calls. Analysis of the habitat environment of each species revealed that their habitats were located at altitudes of 1,046 m (780~1,315 m) for L. intermedius, 1,072 m (762~1,361 m) for K. yezoensis, and 976 m (686~1,245 m) for H. fuscata. Unlike H. fuscata, which was found at a low altitude, K. yezoensis and L. intermedius were not found at altitudes lower than 700 m. Analysis of the average aspect of the habitats of each of the cicada species revealed that L. intermedius was found at 166° (125~207°), K. yezoensis was found at 100° (72~128°), and H. fuscata was found at 173° (118~228°). Examination of the distribution of each of the cicada species revealed that they were predominantly distributed in the ridges and slopes located in the southeastern region of Munsubong in Taebaeksan. In summary, L. intermedius and K. yezoensis was found to inhabit higher altitudes in Taebacksan National Park than H. fuscata, which was found throughout the Korean peninsula. Additionally, the main aspect of the cicada habitat was found to be the southeastern region (100~173°), which has good access to daylight.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF