• Title/Summary/Keyword: 5-Axis

Search Result 2,914, Processing Time 0.047 seconds

Growth and characterization ofZnIn$_2S_4$ single crystal thin film using hot wall epitaxy method (Hot Wall Epitaxy(HWE)에 의한 ZnIn$_2S_4$ 단결정 박막 성장과 특성)

  • 최승평;홍광준
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.4
    • /
    • pp.138-147
    • /
    • 2001
  • The stochiometric mixtures mixture of evaporating materials for the $ZnIn_{2}S_{4}$ single crystal thin film was prepared from horizontal furnace. To obtain the $ZnIn_{2}S_{4}$ single crystal thin film, $ZnIn_{2}S_{4}$ mixed crystal was deposited on throughly etched semi-insulting GaAs(100) in the Hot Wall Epitaxy(HWE) system. The sourceand substrate temperature were $610^{\circ}C$ and $450^{\circ}C$, respectively and the growth rate of the $ZnIn_{2}S_{4}$ single crystal thin film was about 0.5$\mu\textrm{m}$/hr. The crystalline structure of $ZnIn_{2}S_{4}$ single crystal thin film was investigated by photoluminescence and double crystal X-ray diffraction (DCXD) measurement. The carrier density and mobility of $ZnIn_{2}S_{4}$ single crystal thin film measured from Hal effect by van der Pauw method are $8.51{\times}10^{17}{\textrm}{cm}^{-3}$, 291$\textrm{cm}^2$/V.s at $293^{\circ}$K, respectively. From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the $ZnIn_{2}S_{4}$ single crystal thin film, we have found that the values of spin orbit splitting $\Delta$So and the crystal filed splitting DCr were 0.0148eV and 0.1678 eV at $10^{\circ}$K, respectively. From the photoluminescence measurement of $ZnIn_{2}S_{4}$ single crystal thin film, we observed free excition($E_{X}$) typically observed only in high quality crystal and neutral donor bound exicton ($D^{\circ}$, X) having very strong peak intensity. The full width at half maximum and binding energy of neutral donor bound excition were 9meV and 26meV, respectively. The activation energy of impurity measured by Haynes rule was 130meV.

  • PDF

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.

Immunohistochemical Expression of Nuclear Retinoid Receptor and CREB(cAMP Response Element Binding Protein) in Lung Cancers (폐암종에서 Nuclear Retinoid Receptor 및 CREB의 면역조직화학적 발현 양상)

  • Shin, Jong Wook;Gi, Seung-Seok;Paik, Kwang Hyun;Choi, Won;Park, In Won;Kim, Mi Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.6
    • /
    • pp.631-637
    • /
    • 2005
  • Background : Transcriptional factors of the CREB(cAMP Response Element Binding Protein) are involved in the regulation of gene expression in response to a variety of signaling pathways. Proteins produced by the CREB genes play key roles in many physiological processes, including memory and long-term potentiation. The retinoic acid receptor (RAR) axis mediates epithelial cell differentiation and proliferation in many tissues including the lung. Material and method : The RAR and CREB expression levels were examined in 60 adenocarcinomas and 60 squamous cell carcinomas of the lung using immunohistochemical staining. Results : 1) RAR protein expression was found in 58.3%(35/60) of adenocarcinomas and 36.7%(22/60) of squamous cell carcinomas(P<0.05). 2) RAR protein expression was found in 80%(16/20) of well differentiated adenocarcinomas, 60%(12/20) of moderately differentiated adenocarcinomas, and 35%(7/20) of poorly differentiated adenocarcinomas (P<0.01). 3) RAR protein expression was found in 45%(9/20) of well differentiated squamous cell carcinomas, 35%(7/20) of moderately differentiated squamous cell carcinomas, and 30%(6/20) of poorly differentiated squamous cell carcinomas (P>0.05). 4) CREB expression was found in 61.7%(37/60) of adenocarcinomas and 40%(24/60) of squamous cell carcinomas( P<0.05). 5) CREB expression was found in 85%(17/20) of well differentiated adenocarcinomas, 60%(12/20) of moderately differentiated adenocarcinomas, and 40%(8/20) of poorly differentiated adenocarcinomas (P<0.01). 6) CREB expression was found in 45%(9/20) of well differentiated squamous cell carcinomas, 35%(7/20) of moderately differentiated squamous cell carcinomas, and 35%(8/20) of poorly differentiated squamous cell carcinomas(P>0.05). 7) RAR and CREB expression was found in 68.5% of lung cancers, and there was a significant correlation between them(P<0.05). Conclusion : RAR and CREB expression can be used to indirectly determine the malignant potentiality of a cell.

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

Endocrine dysfunction and growth in children with medulloblastoma (소아 수모세포종 환자에서 치료 후의 내분비적 장애와 성장변화)

  • Yoon, In Suk;Seo, Ji Young;Shin, Choong Ho;Kim, Il Han;Shin, Hee Young;Yang, Sei Won;Ahn, Hyo Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.292-297
    • /
    • 2006
  • Purpose : In medulloblastoma, craniospinal radiation therapy combined with chemotherapy improves the prognosis of tumors but results in significant endocrine morbidities. We studied the endocrine morbidity, especially growth pattern changes. Methods : The medical records of 37 patients with medulloblastoma were reviewed retrospectively for evaluation of endocrine function and growth. We performed the growth hormone stimulation test in 16 patients whose growth velocity was lower than 4 cm/yr. Results : The height loss was progressive in most patients. The height standard deviation score (SDS) decreased from $-0.1{\pm}1.3$ initially to $-0.6{\pm}1.0$ after 1 year(P<0.01). Growth hormone deficiency(GHD) developed in 14 patients. During the 2 years of growth hormone(GH) treatment, the improvements of height gain or progressions of height loss were not observed. Twelve patients(32.4 percent) revealed primary hypothyroidism. One of six patients diagnosed with compensated hypothyroidism progressed to primary hypothyroidism. Primary and hypergonadotropic hypogonadism were observed in two and one patients respectively. There was no proven case of central adrenal insufficiency. Conclusion : Growth impairment developed frequently, irrespective of the presence of GHD in childhood survivors of medulloblastoma. GH treatment may prevent further loss of height. The impairment of the hypothalamic-pituitary-gonadal and hypothalamic-pituitary-thyroidal axis is less common, while central adrenal insufficiency was not observed.

Sedimentary Facies and Evolution of the Cretaceous Deep-Sea Channel System in Magallanes Basin, Southern Chile (마젤란 분지의 백악기 심해저 하도 퇴적계의 퇴적상 및 진화)

  • Choe, Moon-Young;Sohn, Young-Kwan;Jo, Hyung-Rae;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.26 no.3
    • /
    • pp.385-400
    • /
    • 2004
  • The Lago Sofia Conglomerate encased in the 2km thick hemipelagic mudstones and thinbedded turbidites of the Cretaceous Cerro Toro Formation, southern Chile, is a deposit of a gigantic submarine channel developed along a foredeep trough. It is hundreds of meters thick kilometers wide, and extends for more than 120km from north to south, representing one of the largest ancient submarine channels in the world. The channel deposits consist of four major facies, including stratified conglomerates (Facies A), massive or graded conglomerates (Facies B), normally graded conglomerates with intraformational megaclasts (Facies C), and thick-bedded massive sandstones (Facies D). Conglomerates of Facies A and B show laterally inclined stratification, foreset stratification, and hollow-fill structures, reminiscent of terrestrial fluvial deposits and are suggestive of highly competent gravelly turbidity currents. Facies C conglomerates are interpreted as deposits of composite or multiphase debris flows associated with preceding hyperconcentrated flows. Facies D sandstones indicate rapidly dissipating, sand-rich turbidity currents. The Lago Sofia Conglomerate occurs as isolated channel-fill bodies in the northern part of the study area, generally less than 100m thick, composed mainly of Facies C conglomerates and intercalated between much thicker fine-grained deposits. Paleocurrent data indicate sediment transport to the east and southeast. They are interpreted to represent tributaries of a larger submarine channel system, which joined to form a trunk channel to the south. The conglomerate in the southern part is more than 300 m thick, composed of subequal proportions of Facies A, B, and C conglomerates, and overlain by hundreds of m-thick turbidite sandstones (Facies D) with scarce intervening fine-grained deposits. It is interpreted as vertically stacked and interconnected channel bodies formed by a trunk channel confined along the axis of the foredeep trough. The channel bodies in the southern part are classified into 5 architectural elements on the basis of large-scale bed geometry and sedimentary facies: (1) stacked sheets, indicative of bedload deposition by turbidity currents and typical of broad gravel bars in terrestrial gravelly braided rivers, (2) laterally-inclined strata, suggestive of lateral accretion with respect to paleocurrent direction and related to spiral flows in curved channel segments around bars, (3) foreset strata, interpreted as the deposits of targe gravel dunes that have migrated downstream under quasi-steady turbidity currents, (4) hollow fills, which are filling thalwegs, minor channels, and local scours, and (5) mass-flow deposits of Facies C. The stacked sheets, laterally inclined strata, and hollow fills are laterally transitional to one another, reflecting juxtaposed geomorphic units of deep-sea channel systems. It is noticeable that the channel bodies in the southern part are of feet stacked toward the east, indicating eastward migration of the channel thalwegs. The laterally inclined strata also dip dominantly to the east. These features suggest that the trunk channel of the Lago Sofia submarine channel system gradually migrated eastward. The eastward channel migration is Interpreted to be due to tectonic forcing imposed by the subduction of an oceanic plate beneath the Andean Cordillera just to the west of the Lago Sofia submarine channel.

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF

Environmental Character and Catch Fluctuation of Set Net Ground in the Coastal Water of Hanlim in Cheju Island II. Fluctuation of Temperature, Salinity and Current (제주도 한림 연안 정치망 어장의 환경특성과 어획량 변동에 관한 연구 II. 수온 및 염분의 변동과 해수의 유동)

  • KIM Jun-Teck;JEONG Dong-Gun;RHO Hong-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.1
    • /
    • pp.98-104
    • /
    • 1999
  • To investigate the relationships between ocean environmental characteristics, the time-series data of temperature and salinity observed at a station near at Hanlim set net in 1995 and 1996 are analyzed, and the results are as follow ; 1. In hanlim set net, the diurnal range of temperature and salinity variation in summer is very large and the amplitude of short-period fluctuation of temperature and salinity is very large. That is, not only the water of the middle and bottom layers (low temperature and high salinity) but also the coalstal water (high temperature and low salinity) appears alternatively depending on the current direction 2. from the result of mooring for 22 days in Hanlim set net, the mean speed and direction of tidal current in neap tide were 9.1 cm/sec and south westward in ebb time, and 11.6 cm/sec and north or northeastward in flood time, respectively. The highest speed of the current was 15cm/sec in ebb time, and 22.6 cm/sec in flood time. The mean speed and direction of tidal current in spring tide were 10.4 cm/sec, and southwestward in ebb time, and 12.3 cm/sec, and north or northestward in flood time, respectively. The highest speed of the current was 19.4 cm/sec in ebb time, and 20 cm/sec in flood time respectively. The mean speed of the current in flood time was larger than that in ebb time. The velocity vector along the major axis of semidiurnal tide ($M_2$) component was 1.5 times larger than that of diurnal tide ($K_1$), The major directions of two compornants were northwestward and east-southeastward and residiual current were 3.25 cm/sec and northwestward-directed. Result of TGPS Buoy tracer for 3 days between Biyang-Do and Chgui-Do showed that the mean speed was 1.6 knot in ebb time and 1.3 knot in flood time. Direction of tidal was southwestward in ebb time and northeastward in flood time respectively. The maximum current speed was 4.8 knot in ebb time and 3.7 knot in flood time respectively. The mean speed and direction of tidal in of offshore were 1.7 knot and northwestward in flood time. The residual current appeared 0.3 knot northeastward.

  • PDF

Analysis of Mistakes in Photosynthesis Unit in Biology II Textbooks and Survey of Biology Teachers' Recognition on them (생물 II 교과서 광합성 단원의 오류 분석 및 생물 교사의 오류 인지 조사)

  • Park, Hae-Kyung;Yoon, Ki-Soon;Kwon, Duck-Kee
    • Journal of Science Education
    • /
    • v.32 no.1
    • /
    • pp.33-46
    • /
    • 2008
  • The purpose of this study was to know whether or not any wrongful description or simple errors were in photosynthesis unit of Biology II textbook under 7th national curriculum and if so, to know whether or not high school teachers recognized and corrected properly the mistakes. The mistakes in photosynthesis unit of text books were determined by the comparison with several reference books and through examination by three plant physiologists in 8 different Biology II textbooks. After the mistakes were analysed, the survey using contents of textbook containing the mistakes was conducted on high school teachers teaching Biology II. As a result, 48 mistakes were determined in 13 subjects. As many as four mistakes were found even in one subject in a certain textbook and a same mistake was found repeatedly in several textbooks. The survey result showed that the teachers who pointed exactly the mistakes out corrected properly, however, the percentage of these ones out of 35 teachers replied to survey was less than 50%. The ratios of correction out of total number of responses were high in question #6 (43%), #4-3 (40%), and #1-2 (32%) which were containing a simple mistake in graph, a wrong word and a wrong picture, respectively. But, no one pointed out and made correction in question #5-1 and #5-2 which were containing Z scheme of light reaction without the legend of vertical axis that should be explained as electron energy or standard reduction potential. The result indicates the possibility that the mistakes in photosynthesis unit of Biology II textbook can be corrected and teached properly by teachers may be low. In order to reduce the possibility that students may have misconceptions about photosynthesis, the list of print's errors should be provided to the teachers and/or the training program and/or workshop for in-service high school biology teachers was recommended.

  • PDF