• Title/Summary/Keyword: 5 Force Model

Search Result 1,110, Processing Time 0.091 seconds

Chatter in Plate Milling with a Face Mill (평판의 정면밀링 가공에서 발생하는 채터)

  • 이상민;이영수;주종남
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.5
    • /
    • pp.46-54
    • /
    • 2004
  • A cutting force model predicting the dynamic force induced by the axial vibration of it plate in face milling is introduced. When a plate face is milled, deformation in tool axial direction is considerable. Therefore, cutting forces are affected by not only inner-outer modulation in feed direction but also by axial deformation. A PTP (peak-to-peak) diagram made by the simulated dynamic force model is evaluated. The stability of the face milling process such as the chatter outset, and the stable cutting region can be simply estimated. Simulation results are compared with that of experiment.

Biomechanical Analysis of the Artificial Discs (인공디스크에 대한 생체역학적 분석)

  • Kim Young-Eun;Yun Sang-Seok;Jung Sang-Ki
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.907-910
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical change with its implantation was rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Two models implanted with artificial discs, SB $Charit\acute{e}$ or Prodisc, via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments and facet joint, and the stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400 N were compared. The implanted model showed increased flexion-extension range of motion and increased force in the vertically oriented ligaments, such as ligamentum flavum, supraspinous ligament and interspinous ligament. The increase of facet contact force on extension were greater in implanted models. The incresed stress distribution on vertebral endplate for implanted cases indicated that additinal bone growth around vertebral body and this is matched well with clinical observation. With axial rotation moment, relatively less axial rotation were observed in SB $Charit\acute{e}$ model than in ProDisc model.

  • PDF

Force control of the five-link robot using wrist force sensor (손목힘 센서를 이용한 5축 로봇의 힘제어)

  • 허영태;이장명
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.552-555
    • /
    • 1996
  • In this paper, we present a force control of a five-axes robot, using an impedance model. Tasks such as assembly, grinding, and deburring, which involve extensive contact with the environment, are better handled by controlling the forces of interaction between the manipulator and the environment. The five-link articulated robot is equipped with a wrist force sensor which consists of an array of strain gauges and can delineate the three components of the vector force along the three axes of the sensor coordinate frame, and the three components of the torque about these axes. For the precise control of the contact force, impedance models of a robot and the environment are defined. Experimental results are shown.

  • PDF

Estimation of External Prestressing Tendon Tension Using Sl Technique Based on Evolutionary Algorithm (진화 알고리즘기반의 SI기법을 이용한 외부 프리스트레싱으로 보강된 텐던의 장력 추정)

  • Jang, Han-Teak;Noh, Myung-Hun;Lee, Sang-Youl;Park, Tae-Hyo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.156-159
    • /
    • 2008
  • This paper introduces a remained tensile force estimation method using SI technique based on evolutionary algorithm for externally prestressed tendon. This paper applies the differential evolutionary scheme to SI technique. A virtual model test using ABAQUS 3 dimensional frame model has been made for this work The virtual model is added to the tensile force(28.5kN). Two set of frequencies are extracted respectively from the virtual test and the self-coding FEM 2 dimension model. The estimating tendon tension for the FEM model is 28.31kN. It is that the error in the tendon tension is 1% through the differential evolutionary algorithm. The errors between virtual model and the self-coding FEM model are assumed as the model error.

  • PDF

Estimation of Loads applied to a Rider using a static Biomechanical Model. (자전거를 탈때의 정적 생체역학 모형에 관한 연구)

  • 반영환;장필식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.197-204
    • /
    • 1997
  • Torques on each joint, the compression on L5/S1 disc, the force on hand of a rider are estimated using a static biomechnic model. Forces that the rider applies to the pedals, saddle and handle during starting and speeding are estimated using static mechanics. Physical stress is considered accroding to handle height and horizontal distance between handle and pedal. When handle height is higher in normal speeding, the force on handle and sum of torques on each joint decreases.

  • PDF

THE GROWTH OF RAT MANDIBLES FOLLOWING MANDIBULAR RETRACTIVE FORCE (백서 하악골 후방견인후의 하악골 성장에 관한 실험적 연구)

  • Kyung, Hee Moon
    • The korean journal of orthodontics
    • /
    • v.19 no.3
    • /
    • pp.15-33
    • /
    • 1989
  • The purpose of this study was to investigate changes of the mandible of a growing rat when they are subjected to a retractive force and those after removal of the retractive force. The experimental animals were Sprague-Dawley male rats of four weeks of age. A mandible was retracted with 50 grams of force on each side in the posterior and superior direction for 8 hours per day. The animals were sacrificed after 1 week, 2-week and 4-week force application, and after 4-week force application-4-week force removal period. The changes of rat mandibular growth following retractive force on the growing rat mandible were observed histologically and biometrically. The findings were as follows ; 1. Histologically, the thickness of the condylar cartilage was slightly reduced in the anterosuperior region with the retractive force. However, in the group of 4-week force application-4-week force removal, there was no significant difference in the thickness of the condylar cartilage. 2. There were no significant histological changes in the articular disk and glenoid fossa through the experimental period. 3. The length and anterior height of the mandible subjected to the retractive force were significantly smaller and greater than those of the control group. 4. There were no significant differences in the mandibular length between 4-week force application - 4-week force removal and the control group. 5. It was concluded that a mandibular retractive force produced inhibitory effects in the growth of the mandible, but that these effects were not sustained during mandibular growth in this experimental model.

  • PDF

A Basic Study on Wheel Flange Climbing using Model Wheelset

  • Nagumo, Yosuke;Tanifuji, Katsuya;Imai, Junichi
    • International Journal of Railway
    • /
    • v.3 no.2
    • /
    • pp.60-67
    • /
    • 2010
  • This paper deals with an experimental study on the wheel flange climbing of railway vehicles, which is a major factor leading to derailment. An experiment is carried out on a 1/5-scale model wheelset of a truck used on a standard-gauge track, which is placed on a roller rig. The lateral external force acting on the wheelset is ramped up until derailment occurs under the condition of a fixed attack angle and wheel-load unbalance ratio. Three parameters, the height of wheel lift, the lateral force, and the wheel load acting on the outer rail, are measured until derailment occurs. From these measurements, it is possible to observe the behavior of the wheelset and to elucidate how the attack angle, the wheel-load unbalance ratio and the lateral external force affect flange-climb derailment. Then, a numerical simulation is carried out using an analytical model based on a single wheelset. As a result, the flange-climb behavior observed in the experiment can be explained theoretically on the bases of the analytical results, although further improvement of the model is desired.

  • PDF

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Nonlinear Analysis of FRP Strengthened Reinforced Concrete Columns by Force-Based Finite Element Model (하중기반 유한요소모델에 의한 FRP 보강 철근콘크리트 기둥의 비선형 해석)

  • Cho, Chang-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.529-537
    • /
    • 2013
  • The aim of the current study is to develop a nonlinear isoparametric layered frame finite element (FE) analysis of FRP strengthened reinforced concrete (RC) beam or column members by a force-based FE formulation. In sections, concrete is modeled in the triaxial stress-strain relationship state and the FRP sheet is modeled as layered composite materials in two-dimension. The element stiffness matrix derived by the force-based FE has the force-interpolation functions without assuming the displacement shape functions. A lateral load test of RC column strengthened by GFRP sheets was analyzed by the developed force-based FE model. From comparative studies of the experimental and analysis results, it was shown to compare with the stiffness FE method that the force-based FE analysis could give more accurate predictions in the overall lateral load-deflection response as well as in nonlinear deformations and damages in the column plastic hinge region.

Improvement of Rolling Force Estimation by Modificaiton Function for Hot Steel Strip Rolling Process (보정함수를 이용한 강판의 열간 압연하중 예측 정도향상)

  • 문영훈;이경종;이필종;이준정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1193-1201
    • /
    • 1993
  • A new deformation resistance model for hot steel strip rolling process was formulated to improve the accuracy of roll force estimation. To improve the existing deformation resistance model more precisely, a modification function was introduced in this study. For the modification function, several factors considering material and operational conditions have been investigated and the optimal modification function was determined under the principle of minimum variability. The newly formulated modification function was applied to the deformation resistance model for ultra-low carbon steel and showed improved accuracy with about 30% decrease in terms of standard deviation of predicted roll force values against measured ones.