• 제목/요약/키워드: 4G architecture

검색결과 365건 처리시간 0.03초

Green Building Design Strategies for Multiplex Housing

  • Park, Won Ho;Ahn, Yong Han;Choi, Young-Oh
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.21-30
    • /
    • 2016
  • Purpose: Energy saving in the built facilities is getting important due to energy crisis. The Korea government has been implemented several energy and green building policies and practices. The both of government and industry also developed green building strategies ant technologies to reduce energy consumption and carbon emission. The purpose of this research is to identify applicable green building strategies and technologies for that can be cost effective and applicable to a multiplex house. Method: This research identified appropriate green building strategies from analysing green building strategies from G-SEED certified apartment projects and popular green building strategies. This study also adopted a survey research method to find out the applicable green building strategies for a multiplex housing. In addition, this research also conduct cost estimating to identify initial cost premium of green building strategies. Results: The research outcomes in this study guide a building owner to know about initial cost premiums of green building strategies and technologies and an architect and contractor to identify appropriate and cost effective green building strategies that can be applicable to a multiplex house.

Plant Regeneration from Mesophyll Protoplasts Culture of Solanum sisymbriifolium

  • Kim Hag-Hyun;Shin Un-Dong
    • Journal of Plant Biotechnology
    • /
    • 제7권3호
    • /
    • pp.169-174
    • /
    • 2005
  • The optimal culture conditions were studied for plant regeneration from mesophyll protoplasts of Solanum sisymbriifolium. Axenic seedlings of S. sisymbriifolium were used as a explant for protoplast culture. Many viable protoplasts were isolated by incubating leaf slices in an enzyme solution containing 0.25% Meicerase and 0.05% Macerozyme for 16 hr at $25^{\circ}C$ without shaking. Protoplast density of $5.0{\times}10^4\;ml^{-1}$ in Kao medium containing 5.0 mg/L NAA, 1.0 mg/L 2,4-D and 1.0 mg/L BA was optimal for colony formation. Most colonies were formed when protoplasts were cultured at $25^{\circ}C$ after initial culture at $30^{\circ}C$ for one week. On the MS agar medium with 1.0 mg/L zeatin, 38.4% of protoplast-derived calli differentiated shoots. These shoots rooted on 1/2MS medium with 5.0 g/L sucrose and 2.5 g/L gellan gum, and developed into whole plants.

Numerical simulation of unsteady propeller force for a submarine in straight ahead sailing and steady diving maneuver

  • Pan, Yu-cun;Zhang, Huai-xin;Zhou, Qi-dou
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.899-913
    • /
    • 2019
  • In order to provide a complementary perspective to the effects of the maneuvering motions on the unsteady propeller performance, the numerical simulation of the flow field of the hull-rudder- propeller system is performed by Unsteady Reynolds-averaged Naiver-Stokes (URANS) method. Firstly, the flow fields around the submarine model without the presence of propeller in straight ahead motion and the steady diving maneuvers with submergence rudder deflections of 4°, 8° and 12° are predicted numerically. The non-uniformity characteristic of the nominal wake field is exacerbated with the increase submergence rudder angle. Then the flow field around the SUBOFF-G submarine fitted with the 4381 propeller is simulated. The axial, transverse and vertical unsteady propeller forces in different maneuvering conditions are compared. In general, as the submarine maneuvers more violently, the harmonic amplitudes of the unsteady force at the 2BPF and 3BPF increased more significantly than that at BPF.

국가지정입원격리병상의 시설별 면적구성에 관한 연구 - 2016년 국가지정입원격리병상 확충사업대상을 중심으로 (A Study on the Area Composition Analysis of the National Designated Isolation Unit Wards(NDIUs) - Focused on the NDIU wards issued in 2016)

  • 윤형진;권순정
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권2호
    • /
    • pp.73-82
    • /
    • 2017
  • Purpose: Since the facility guidelines for National Designated Isolation Unit wards(NDIUs) had been edited since 2016, all hospital who want to expand or install NDIU should adapt the new guidelines. Instead of providing area requirement, by the way, only essential or optional facility requirements are suggested except patient bedroom in the guidelines. So, as analyze area and area composition of the NDIUs, it could be expected that this study has a role as an area planing reference for not only NDIU but also another airborne infection isolation room. Methods: For the area analysis, 18 sample hospitals are selected among 2016 year applicants. All rooms in NDIUs are grouped as zones whether those are negative air pressurized or not and programed room or not. At the end, area of the zones are summarized and analysed a relationship between area increase and bed number by both correlation analysis and regression analysis. In addition, department usable and gross area per bed, N/G ratio, G/N ratio, and average area ratio of each zone is calculated. Results: First of all, rooms in none negative air pressurized zone of the NDIUs haven't shown a regular installation so that only those in negative air pressurized zone are targeted for the area analysis. Second of all, patient room unit(0.92) and support area(0.79), by correlation analysis, are correlated with total net area. Patient room unit(0.94) and total net area(0.79) are also shown a correlation with bed number. Department usable area($R^2=0.63$, y=36.278x + 102) and patient room unit area($R^2=0.89$, y= 27.993x - 0.8924) has a relationship with bed number by regression analysis. Average N/G is shown as 0.85 and G/N 1.36. Average area ratio of circulation, doffing area, patient room unit, and support area are 25.4%, 9.1%, 50.9%, and 14.6% in order. Implications: This study is a basic research for exploring the NDIUs guidelines to find resonable evidence to develop it for its practical use. Still, it is possibly expected that the guideline is to be developed by post occupancy evaluation in the area of where minimum requirement or facility grade needs to be defined, and by further studies with various perspectives.

도시 열섬현상 저감을 위한 MPCM 적용 축열도료 제조 및 열적성능 평가 (Preparation and Thermal Performance Evaluation of Heat Storage paint with MPCM for Reducing Urban Heat Island Effect)

  • 정수광;강유진;위승환;장성진;김수민
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.17-24
    • /
    • 2015
  • The formation of heat islands causes high energy demand for space cooling and peak cooling loads in conditioned buildings. High-temperature fluctuations on a building roof may cause mechanical stress and increase surface deterioration. Thermal energy storage (TES) systems using microencapsulated phase-change materials (MPCMs) have been recognized as one of the most advanced energy technologies for enhancing the energy efficiency and sustainability of buildings. In this study, we prepared MPCM/paint composites for mitigating the heat island effect and reducing peak temperature. In addition, we carried out thermal and physical analysis of prepared MPCM composite samples by means of SEM, FTIR spectroscopy, DSC, and TGA. Further, we evaluated the dynamic heat transfer performance of heat-storage tiles painted with 10 g of heat-storage paint. From the obtained results, we deduced that MPCM/hydrophilic paint composites are more applicable to various fields, including the building sector, than MPCM/hydrophobic paint composites. On the basis of SEM and FTIR spectroscopy results, we concluded that materials with hydrophilic properties are more compatible with MPCMs than those with hydrophobic properties. In addition, DSC analysis results revealed that MPCM/hydrophilic paint composites have better compatibility, higher latent heat capacity, and better thermal properties than other composites. TGA results showed that hydrophilic-paint-based composites have higher thermal durability than hydrophobic-paint-based composites. Finally, a lot of MPCM-loaded heat-storage tiles showed lower peak temperatures at all measurement positions.

차광정도가 곤달비의 토양변화, 생육상황 및 엽록소 함량에 미치는 영향 (Effect of Shading Levels on the Soil Properties, Growth Characteristics, and Chlorophyll Contents of Ligularia stenocephala)

  • 박병모;김창환;배종향;신중열
    • 생물환경조절학회지
    • /
    • 제20권4호
    • /
    • pp.352-356
    • /
    • 2011
  • 산업의 발달로 인하여 인구의 도시 집중화 현상 때문에 건물의 고층화 및 생활공간의 밀집화가 되고 있는 실정이다. 또한 휴식을 취할 수 있는 공간이 점차 축소되고 있으며 이러한 원인 때문에 보다 많은 녹지면적이 필요한 실정이다. 그러나 건물의 고층화로 인한 광부족과 환경오염으로 인한 대기의 조건 등이 식물생육에 아주 부적합하다. 특히 건물의 고층화 및 밀집화로 식물 생육에 지장을 주는 음지로 인하여 식물생육에 문제가 되기 때문에 음지에 강한 새로운 조경용 지피식물의 개발이 절실하다. 따라서 쌈채식물로 알려져 있는 곤달비를 30%, 50%, 80%의 차광에 재배를 하여 차광에 따른 토양환경의 변화, 식물생장, 엽록소 함량 등을 조사한 결과 다음과 같았다. 엽수는 50% 차광이 10.8개, 30% 차광이 8.4개로 무차광재배의 7.7개에 비하여 많았으며 엽폭도 50% 차광 재배에서 가장 우수 하여 음지성 지피식물로 식재가능 하였다. 생체중은 무처리구 90.43g에 비하여 모든 차광재배가 각각 31.63g, 43.39g, 19.40g로 증가 하였으며 특히 뿌리의 생육이 줄기의 생육에 비하여 30% 차광재배의 12.33g에 비하여 48.48g으로 많이 증가 하였다. 엽록소 합성은 50% 차광의 경우 46.2로 무차광재배의 41.9에 비하여 증가하였으며 기타 차광재배의 경우는 오히려 줄어드는 경향이었다. 곤달비의 차광재배의 결과 50% 차광처리가 지피식물로서 생육이 가장 양호하였다.

Improved Mesoporous Structure of High Surface Area Carbon Nanofiber for Electrical Double-Layer Capacitors

  • Lee, Young-Geun.;An, Geon-Hyoung;Ahn, Hyo-Jin
    • 한국재료학회지
    • /
    • 제27권4호
    • /
    • pp.192-198
    • /
    • 2017
  • Carbon nanofiber (CNF) is used as an electrode material for electrical double layer capacitors (EDLCs), and is being consistently researched to improve its electrochemical performance. However, CNF still faces important challenges due to the low mesopore volume, leading to a poor high-rate performance. In the present study, we prepared the unique architecture of the activated mesoporous CNF with a high specific surface area and high mesopore volume, which were successfully synthesized using PMMA as a pore-forming agent and the KOH activation. The activated mesoporous CNF was found to exhibit the high specific surface area of $703m^2g^{-1}$, total pore volume of $0.51cm^3g^{-1}$, average pore diameter of 2.9 nm, and high mesopore volume of 35.2 %. The activated mesoporous CNF also indicated the high specific capacitance of $143F\;g^{-1}$, high-rate performance, high energy density of $17.9-13.0W\;h\;kg^{-1}$, and excellent cycling stability. Therefore, this unique architecture with a high specific surface area and high mesopore volume provides profitable synergistic effects in terms of the increased electrical double-layer area and favorable ion diffusion at a high current density. Consequently, the activated mesoporous CNF is a promising candidate as an electrode material for high-performance EDLCs.

국내 건설현장 근로자의 불안전한 행동 분석 (The Analysis on the Unsafe Acts of Laborers at Domestic Construction Sites)

  • 한인혜;양기남;조홍규;정경환;김광희;신윤석
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.132-139
    • /
    • 2014
  • According to the increase of foreign laborers at domestic construction sites, it's necessary to research in terms of the unsafe acts of both Korean and foreign laborers in order to prevent construction disasters. The objective of this study is to clarify the characteristics and the improvement priority of the unsafe acts using IPA(Importance-Performance Analysis). The result of this study showed which items of unsafe acts are identify difference between Korean and foreign laborers. Moreover, the result of IPA also showed items of unsafe acts that needed the immediate improvement for each one. Especially there are two items, i.e. equipment malfunction and wrong handling of hand tools, which both Korean and foreign laborers think simultaneous those needs improvement. The results can be utilized to plan and to improve the safety management and education at a site considering the characteristics of foreign laborers.

인산 시비농도가 잎들깨의 생육, 결핍증상 및 무기원소 함량에 미치는 영향 (Growth, Deficiency Symptom and Tissue Nutrient Contents of Leaf Perilla (Perilla frutesens Britt) Influenced by Phosphorus Concentrations in Fertigation Solution)

  • 최종명;박종윤
    • 생물환경조절학회지
    • /
    • 제16권4호
    • /
    • pp.358-364
    • /
    • 2007
  • 시비농도를 인위적으로 조절하여 잎들깨를 관비재배하면서 인산의 시비수준이 생장과 결핍증상 발현에 미치는 영향을 구명하고, 생육을 우수하게 유지할 수 있는 식물체 및 토양의 한계농도를 밝히기 위하여 본 연구를 수행하였다. 인산이 결핍될 경우 전체 지상부 생육이 심하게 억제되었으며, 노엽에서 초기증상이 발현되고, 엽병과 엽신이 자주색을 띄는 특징을 보였다. 증상이 나타난 부위는 점차 갈변하고 괴사하였다. 본 연구의 인산 시비수준 내에서는 농도가 높아질수록 식물 생육이 증가하여 0, 0.5 및 4.0mM 시비구에서 생체중이 각각 0.48g, 9.289 및 25.5g였고, 건물중이 0.06g, 1.46g 및 4.13g으로 조사되었다. 생육이 가장 우수하였던 4.0mM 처리에서 지상부 인산함량과 엽병추출액의 인산 농도가 1.78% 및 $2,040mg{\cdot}kg^{-1}$였고, 이 보다 10%낮은 식물 생육을 최저 한계점으로 판단한다면 각각 0.3% 및 $900mg{\cdot}kg^{-1}$ 이상의 인산 농도를 유지하도록 시비해야 한다고 판단하였다. 정식 65일 후 인산 4.0mM 처리의 토양 인산 농도가 $1.26mg{\cdot}L^{-1}$였으며, 이 또한 수량감소를 방지하기 위해 $0.57mg{\cdot}L^{-1}$ 이상의 토양 농도를 유지하도록 시비해야 할 것으로 판단하였다.

축산관련차량 이동에 따른 도로의 에어로졸 발생량 분석 (Aerosol Emission from Road by Livestock Transport Vehicle Movement)

  • 서일환;이인복;황현섭;배연정;배승종;문운경
    • 농촌계획
    • /
    • 제19권4호
    • /
    • pp.137-147
    • /
    • 2013
  • Most of livestock houses are concentrated in certain area with mass rearing system resulting in rapid spread of infectious diseases such as HPAI (highly pathogenic avian influenza). The livestock-related vehicles which frequently travel between farms could be a major factor for disease spread by means of transmission of airborne aerosol including pathogens. This study was focused on the quantitative measurement of aerosol concentration by field experiment while vehicles were passing through the road. The TSP (total suspended particle) and PM10 (particle matter) were measured using air sampler with teflon filter installed downward the road with consideration of weather forecast and the direction of road. And aerosol spectrometer and video recorders were also used to measure the real-time distribution of aerosol concentration by its size. The results showed that PM2.5 was not considerable for transmission of airborne aerosol from the livestock-related vehicle. The mass generated from the road during the vehicle movement was measured and calculated to 241.4 ${\mu}g/m^3$ by means of the difference between TSP and PM2.5. The dispersion distance was predicted by 79.6 m from the trend curve.