• Title/Summary/Keyword: 46S40

Search Result 1,252, Processing Time 0.034 seconds

Evaluation of Contrast-detail Characteristics of an A-Se Based Digital X-ray Imaging System (A-Se 기반 디지털 X-선 영상장치의 Contrast-detail 특성 평가)

  • Hyun, Hye-Kyung;Park, So-Hyun;Kim, Keun-Young;Cho, Hee-Moon;Cho, Hyo-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.11-16
    • /
    • 2007
  • In this study, we have performed contrast-detail analysis for an amorphous selenium(a-Se) based digital X-ray imaging system by using a contrast-detail phantom(CDRAD 2.0) to test its low contrast performance. The X-ray imaging system utilizes an 500-mm-thick a-Se semiconductor X-ray absorber coated over an amorphous silicon(a-Si) TFT(thin-film transistor) detector matrix with a $139mm{\times}139mm$ pixel size and a $46.7cm{\times}46.7cm$ active area. In the measurement of contrast-detail curves we first acquired X-ray images of the CDRAD 2.0 phantom at given test conditions(i.e., 40, 50, 60, 70, 80 kVp, and 16 mA.s), and then evaluated the contrast-detail characteristics of the imaging system from each phantom image by using an image quality factor called the image-quality-figure-inverse(IQFinv). The IQFinv values for the imaging system gradually improved with the photon fluence, indicating the improvement of image visibility: 24.4, 35.3, 39.2, 41.5, and 43.4 at photon fluences of $1.8{\times}105$, $5.9{\times}105$, $11.3{\times}105$, $19.4{\times}105$, and $29.4{\times}105$ photons/$mm^2$, respectively.

  • PDF

Study on Extraction of Mucopolysaccharide-protein Containing Chondroitin Sulfate from Chicken Keel Cartilage

  • Shin, S.C.;You, S.J.;An, B.K.;Kang, C.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.4
    • /
    • pp.601-604
    • /
    • 2006
  • The objective of this study was to investigate technical methods for extraction of mucopolysachharide-protein containing chondroitin sulfate from keel cartilage of chickens. The chemical composition of chicken keel cartilage was determined. For the preparation of mucopolysaccharide-protein from lyophilized chicken keel cartilage, hot water extraction and alcalase hydrolysis methods were examined. Results showed that the optimum condition of hot water extraction was incubation for 120 min with a yield of 40.09% and chondroitin sulfate content of 28.46%. For alcalase hydrolysis, the most effective condition was 2% alcalase in 10 volumes of distilled water for 120 min. The yield of hydrolysate was 75.87%, and chondroitin sulfate content was 26.61%. For further separation of chondroitin sulfate from the alcalase hydrolysate, which has a higher yield than that of hot water, 60% ethanol precipitation was performed. The yield of the ethanol precipitate was 21.41% and its chondroitin sulfate content was 46.31%. The hot water extract, alcalase hydrolysate and ethanol precipitate showed similar electrophoretic migration with standard chondroitin sulfate (chondroitin sulfate A), using cellulose acetate membrane electrophoresis. These results indicated that a significant amount of mucopolysaccharide-protein containing chondroitin sulfate could be acquired form chicken keel cartilage. Therefore, keel cartilage in chicken may provide an inexpensive source of chondroitin sulfate for commercial purposes.

Collection characteristics of electro-static multi-staged impaction system for air pollutants removal of marine diesel engines (박용디젤기관의 대기오염 저감을 위한 전기 다단 임팩션 시스템의 집진특성)

  • YOA, Seok-Jun;KWON, Jun-Hyeong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.4
    • /
    • pp.545-552
    • /
    • 2015
  • The main object of this study is to investigate the collection characteristics of an electro-static multi-staged impaction system, experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as the inlet velocity, stage number, applied voltage and shape of discharge electrode, etc. In results, the pressure drop is shown below $148mmH_2O$ lower than that of the conventional bag filter at inlet velocity 3.46 m/s and 5 stage. For 5 stage, the collection efficiencies are to be 97.4, 99.0% with the applied voltage 0 kV at the inlet velocity 2.07, 3.46 m/s, while 98.4, 99.9% with 40 kV of a sharp edge discharge electrode. Additionally, the present system is to be considered as an effective compact system for a removal of particulate pollutants from marine diesel engines due to much higher collection efficiency and appropriate pressure drop.

Cavitation Test at High Reynolds Number Using a Partial Propeller Blade Model (부분 프로펠러 날개 모형을 이용한 높은 레이놀즈 수에서의 공동시험)

  • Choi, Gil-Hwan;Chang, Bong-Jun;Cho, Dae-Seung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.6
    • /
    • pp.569-577
    • /
    • 2009
  • As the scale factor of model propellers utilized in cavitation test is about 40, it is difficult to find out practical countermeasures against the small area erosions on the blade tip region throughout model erosion tests. In this study, a partial propeller blade model was used for the observation of cavitation pattern for the eroded propeller. A partial propeller blade model was manufactured from 0.7R to tip with expanded profile and with adjustable device of angle of attack. Reynold's number of a partial propeller blade model is 7 times larger than that of a model propeller. Also, anti-singing edge and application of countermeasures to partial propeller blade model which produced in large scale can be more practical than a model propeller. For the observation of cavitation at high Reynold's number, high speed cavitation tunnel was used. To find out the most severe erosive blade position during a revolution, cavitation observation tests were carried out at 5 blade angle positions.

Effect of Flooding Treatment on the Desalting Efficiency and the Growth of Soiling and Forage Crops in a Sandy Soil of the Iweon Reclaimed Tidal Land in Korea (이원간척지 사질 염류토양의 담수제염처리가 제염효과와 녹비.사료작물의 생육에 미치는 영향)

  • Sohn, Yong-Man;Kim, Hyun-Tea;Jeon, Geon-Yeong;Song, Jae-Do;Lee, Jae-Hwang;Park, Moo-Eon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.1
    • /
    • pp.16-24
    • /
    • 2010
  • Effect of flooding on the desalting efficiency and the growth of sudan grass, barnyard grass, sesbania and corn was studied in a sandy soil of the Iweon reclaimed tidal land. Flooding plots were treated by 400 (one time flooding), 800 (two times flooding), and 1,200 mm(three times flooding) of water, respectively, and then soil salinities of the treated plots were compared with salinity of the control plot (not flooded) for estimation of desalting effect. Desalting ratio of 1,200 mm treatment was 78.3% for depth 0-20 cm, 70.5% for depth 20-40 cm and 60.8% for depth 40-60 cm, and then the soil salinity reached at 3~6 dS $m^{-1}$. Consequently, it was considered that sandy saline soil was satisfactorily desalted for upland crops to be cultivated by 1,200 mm flooding, but insufficiently desalted by 400 mm and 800 mm flooding because of high salinity ranged 5~14 dS $m^{-1}$ even after flooding treatment. In addition, it was estimated that soil salinity should be controled lower than 7.7 dS $m^{-1}$ in order to obtain more than 80%of crop emergence when four crops are simultaneously cultivated by inter- or mixed cropping in a field. Dry matter yields (kg $10a^{-1}$) was 1,068 for sudan grass, 696for barnyard grass, 1,426 for sesbania, and 1,164 for corn by 1,200 mm flooding treatment, but only 46.8~74.3% by 800 mm flooding treatment and 2.9~25.5% by 400 mm flooding treatment. Therefore, it is concluded that the flooding treatment more than 1,200 mm is necessary for satisfactory desalinization in order for the low salt tolerance crops to be cultivated in the sandy reclaimed tidal land.

A Study on the Changes in Spatial Composition Ratio of National Rental Houses - Focused on the Jangseong-gun Jeollanam-do Province - (국민임대주택의 평면구성비 변화에 관한 연구 -전라남도 장성군을 중심으로 -)

  • Kim, Hong-Bae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • This study aims to investigate the changes in area ratios by space through floor plans of national leasing houses constructed by the LH in Jangseong-gun, particularly focusing on the floor plans of public leasing housing complexes built during the 1970s-80s and those during the 2010s. The results are as follows: First, according to the composition ratio of floor plans by period, the type of Bedroom> Livingroom> Common Area> Kitchen+Dining> Multi-purpose room> Bathroom> or the type of Bedroom> Livingroom> Kitchen/Dining> Common Area> Bathroom> Multi-purpose room were found to be high during the 1970s. Whereas, the type of Common Area>Living room(Kitchen/Dining included)>Bedroom>Bathroom>Front Entrance was found to be high during the 2010. It can be concluded that the ratio of Bedroom and Living room was found to be high during the 1970s, but after 2010s, the spacial composition ratio of Common Space, Living room, and Bedroom is getting higher in the order. Second, in terms of the composition ratio of floor plans by the area of unit household, among the floor plan of C-1, B-2, B-3, C-2 which were used since 2010s, the spatial ratio of Bedroom was maintained in the range of 20%; while during the 1970s, the Bedroom space of A-1(46%), A-2(46%), and A-3(41%) was found to be higher than 40%. It can be concluded that the size of bedroom space has doubled over time. In terms of the changes in the spatial ratio of Living room, A-1(15%), A-2(22%), and A-3(23%) were found during the 1970s. Compared to the recent floor plans of C-1(28%), B-2(25%), B-3(33%), and C-2(34%) which are applied in Jangseong-gun, Jeollanam-do province, no big changes have been found, particularly in the small floor plans (20% range).

Fatigue-Decreased Proficiency(FDP) Boundary for Whole-Body Vibration Exposure in Passenger Car Driver (승용차 운전자의 전신진동노출에 대한 피로-감소숙달 경계)

  • Jeung ae Yeal;Lee Ki-Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.6
    • /
    • pp.1211-1216
    • /
    • 2002
  • To evaluate whole-body vibration(WBV) exposure and fatigue-decreased proficiency(FDP) boundary in passenger car driver, several roads in Busan were divided into 3 types by the condition of road surface; Road 1 was partially damaged, Road 2 was normal without damage, and Road 3 was better than Road 2. The results were following: The highest passenger driver's exposures to whole-body vibration acceleration and fatigue-decreased proficiency boundary at 40km/h were 0.108m/s² and about 2099 minutes in Road 2 for xh axis, 0.134m/s² and about 1585 minutes in Road 2 for yh axis, and 0.183m/s² and about 1053 minutes in Road 2 for zh axis, respectively. The highest passenger driver's exposures to whole-body vibration acceleration and fatigue-decreased proficiency boundary at 80km/h were 0.219m/s² and about 830 minutes in Road 3 xh axis, 0.203m/s² and about 918 minutes in Road 3 for yh axis, and 0.622m/s² and about 195 minutes in Road 1 for zh axis, respectively. The highest vector sums of whole-body vibration exposure at 40km/h and 804km/h were 0.328m/s² in Road 2 and 0.730m/s² in Road 1, respectively. The highest crest factors at 40km/h were 4.25 in Road 1 for xh, 4.51 in Road 3 for yh, and 5.81 in Road 2 for zh, respectively. The highest crest factors at 80km/h were 5.57 in Road 1 for xh, 5.60 in Road 2 for yh, and 6.46 in Road 3 for zh, respectively. The highest transmissibilities of whole-body vibration from floor to seat at 40km/h and 80km/h were 0.89 in Road 3 and 0.82 in Road 3 for xh axis, 0.83 in Road 3 and 0.87 in Road 1 and 2 for yh, and 0.80 in Road 2 and 0.92 in Road 1 tor zh axis, respectively. The highest fatigue-decreased proficiency boundaries for whole-body vibration exposure of passenger car driver in floor and seat were 457 minutes in Road 3 and 583 minutes in Road 3 at 40km/h and 159 minutes in Road 2 and 251 minutes in Road 2 at 80km/h, respectively.

Period changes in the Intermediate Polar MU Camelopardalis

  • Park, Jiwon;Yoon, Jho-Na;Kim, Yonggi;Andronov, I.L.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.89.1-89.1
    • /
    • 2015
  • Period changes found in the 10 years CCD BVR photometry data (2005 - 2014) of the Intermediate Polar MU Cam will be discussed. The timings of extrema of the data are determined and the new ephemeris for the spin period and orbital period have been calculated by using multi-periodic approximation as follows: BJD(orb)=2454085.46(19)+0.19664 $10(26){\cdot}E$ and BJD(spin)=2454085.50725(91)+0.013740942(13) ${\cdot}$ $E-1.51(10){\times}10^{-12}{\cdot}E^2$. The O-C diagram shows an increasing of the spin period as $P=-2.20(14){\cdot}10^{-12}s/s$. It is also found in MU Cam that the white dwarf's rotation seems to be switched from a state of spin-down to spin-up by the white dwarf's equilibrium spin period in 2005.

  • PDF

Basic Study on Flashover Characteristics of Power Lines by Forest Fire(I) (산불화재에 의한 전력선 섬락사고 기초연구(I))

  • Kim, C.N.;Lee, S.W.;Lee, K.S.;Kim, I.S.;Lee, D.I.;Park, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.387-390
    • /
    • 2001
  • The experiments were performed in model conductors under the application of ac and dc high-voltages. The results of an experimental investigation into the flashover characteristics of air dielectric strength in the presence of oil/gas flame are reported. It is demonstrated that flame can reduce by more than half, 80% in maximum the breakdown voltage of a model line. Taking a horizontal model line with a k=0.5, it can be seen from the results that the reduction of flashover levels, in comparison with the no-flame case, are 78.7[%] for h=0[cm], 59.6[%] for h=3[cm], 46.4[%] for h=6[cm], 40.4[%] for h=9[cm] and 23.2[%] for h=12[cm] when ac voltage is applied.

  • PDF

Studies on the Viability of Frozen Removed Seminal Plasma by Saline(RSP-S) and Tris-buffer(RSP-T) Semen of Small Spcies Dogs (소형 개 RSP-S와 RSP-T 정액의 동결 융해후의 생존성에 관한 연구)

  • 김상근
    • Korean Journal of Animal Reproduction
    • /
    • v.25 no.3
    • /
    • pp.269-275
    • /
    • 2001
  • This study was carried out to investigate the general characteristics such as volume, sperm concentration, sperm motility, sperm abnormality on whole semen, RSP-S and RSP-T semen and fractional semen of small size dogs, and the effect of temperature and preservation time and cryoproservation on motility of whole and RSP-S and RSP-T semen. Multiple ejaculates were collected from small dogs by the digital manipulation of penis. 1. The volume per ejaculate semen, sperm of concentration and motility and abnormal sperm rate of 1st fractional semen were 0.65$\pm$0.09 $m\ell$, 4.52$\pm$0.35$\times$10$^{6}$ cells/$m\ell$, 15.64$\pm$3.85% and 5.50$\pm$0.62%. Also, 2nd fractional semen were 1.25$\pm$0.20$m\ell$, 3.35$\pm$0.48$\times$10$^{6}$ cells/$m\ell$, 96.25$\pm$4.65% and 4.24$\pm$0.46%. And 3rd fractional semen were 1.45$\pm$0.21$m\ell$, 3.55$\pm$0.52$\times$10$^{6}$ cells/$m\ell$, 92.82$\pm$4.24% and 4.66 $\pm$0.58%, respectively. 2. The sperm of concentration and motility and abnormal sperm rates of whole, RSP-S and RSP-T semen were 5.45$\pm$0.82$\times$10$^{6}$ cells/$m\ell$, 95.55 $\pm$4.65%, 4.58$\pm$0.45% and 4.82$\pm$0.36$\times$10$^{6}$ cells/$m\ell$, 90.10$\pm$3.42%, 6.48$\pm$0.68% and 4.55$\pm$0.45$\times$10$^{6}$ cells/$m\ell$, 93.25$\pm$3.85%, 4.82$\pm$0.58%, respectively. 3. The motility of whole, RSP-S and RSP-T semen were higher at 4$^{\circ}C$ than at 38$^{\circ}C$. When preservation temperature was at 4$^{\circ}C$, survival rates of RSP-S and RSP-T sperm were 97.54~6.25% at 1~72 hrs, 97.40~5.62% at 1~100 hrs, respectively. 4. The survival rates of slow and rapid frozen 2nd fraction, RSP-S and RSP-T semen were 67.3$\pm$4.45%, 88.8$\pm$4.46% and 46.4$\pm$3.84%, 74.4$\pm$4.20%, respectively. Survival rates was significantly higher in frozen RSP-S and RSP-T semen than that in control group(8.5$\pm$2.12%).

  • PDF