• Title/Summary/Keyword: 4 probe measurement

Search Result 310, Processing Time 0.027 seconds

Soft Tissue Measurement Method Using Radiopaque Material on Cone-beam Computed Tomography: An Ex Vivo Validation Study

  • Lee, Hae-Seok;Yun, Jeong-Ho;Lee, Dong-Won
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the validity and reproducibility of a method based on cone-beam computed tomography (CBCT) technology for the visualization and measurement of gingival soft-tissue dimensions. Material and Methods: A total of 66 selected points in soft-tissue of the ex vivo head of an adult pig were investigated in this study. For the measurement of radiographic thickness (RT), wet soft-tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken and DICOM files were assessed for soft-tissue thickness measurement at reference points. A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT). After flap elevation, actual thickness of soft-tissue (actual thickness, AT) was measured. Correlation analysis and intraclass correlation coefficients analysis (ICC) were performed for AT, TPT, and RT. Results: All variables were distributed normally. Strong significant correlations of AT with RT and TPT values were found. The two ICC values between TPT vs. AT and RT vs. AT differed significantly. Conclusion: Our results indicated that correlation of RT was stronger than that of TPT with AT. We concluded that soft tissue measurement with CBCT could be a reliable method, compared to the trans-gingival probing measurement method.

CHALLENGING APPLICATIONS FOR FT-NIR SPECTROSCOPY

  • Goode, Jon G.;Londhe, Sameer;Dejesus, Steve;Wang, Qian
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4112-4112
    • /
    • 2001
  • The feasibility of NIR spectroscopy as a quick and nondestructive method for quality control of uniformity of coating thickness of pharmaceutical tablets was investigated. Near infrared spectra of a set of pharmaceutical tablets with varying coating thickness were measured with a diffuse reflectance fiber optic probe connected to a Broker IFS 28/N FT-NIR spectrometer. The challenging issues encountered in this study included: 1. The similarity of the formulation of the core and coating materials, 2. The lack of sufficient calibration samples and 3. The non-linear relationship between the NIR spectral intensity and coating: thickness. A peak at 7184 $cm^{-1}$ was identified that differed for the coating material and the core material when M spectra were collected at 2 $cm^{-1}$ resolution (0.4 nm at 7184 $cm^{-1}$). The study showed that the coating thickness can be analyzed by polynomial fitting of the peak area of the selected peak, while least squares calibration of the same data failed due to the lack of availability of sufficient calibration samples. Samples of coal powder and solid pieces of coal were analyzed by FT-NIR diffuse reflectance spectroscopy with the goal of predicting their ash content, percentage of volatile components, and energy content. The measurements were performed on a Broker Vector 22N spectrometer with a fiber optic probe. A partial least squares model was constructed for each of the parameters of interest for solid and powdered sample forms separately. Calibration models varied in size from 4 to 10 PLS ranks. Correlation coefficients for these models ranged from 86.6 to 95.0%, with root-mean-square errors of cross validation comparable to the corresponding reference measurement methods. The use of FT-NIR diffuse reflectance measurement techniques was found to be a significant improvement over existing measurement methodologies in terms of speed and ease of use, while maintaining the desired accuracy for all parameters and sample forms.(Figure Omitted).

  • PDF

Study on terminal shape and pressure for contact type Ic measurement of long Bi-2223 tape (Bi-2223 초전도 테이프의 접촉식 Ic 측정을 위한 단자 형상 및 압력 조사)

  • Ha, D.W.;Yang, J.S.;Ha, H.S.;Oh, S.S.;Kwon, Y.K.;Ryu, K.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.25-28
    • /
    • 2002
  • Contact type Ic measurement system is needed to measure Ic continuously for long Bi-2223 tapes. Voltage and current terminals were designed several shapes for 4-probe method Ic measurement. Voltage terminals were made with brass and current terminals were made with Cu. We used 2 kinds of Bi-2223 tapes with different strength. When we measured Ic of Bi-2223 tape with Ag-Mg sheath, The proper weight was 0.3 kg and sharp pin type was better. according to voltage terminal shape and load. In case of Bi-2223 tape with Ag-Mn sheath, the proper terminal weight was 4 kg and sharp pin type was bad. It was possible to make continuous contact type Ic measurement system because We could get proper data - terminal shapes and loads - through these experiments.

  • PDF

A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry (실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • Moon, Sang-Joon;Kang, Young-June;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.

Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique (자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정)

  • Kim, Jung-Ho;Lee, Seung-Muk;Joo, Jin-Ho
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

A New Design of AFM Probe for Nanotribological Characterizations Measurement of Human Hair (모발의 나노 트라이볼러지 특성해명을 위한 원자현미경(Atomic Force Microscopy) 프로브의 개발)

  • Kweon, Hyun Kyu;Gao, Yan Wei
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • People are always pursuing the aesthetic feeling relentlessly. But some people have such problems with their hairs like alopecia, cancer chemotherapy, burns, and scalp injury. So the synthetic hair has played a very important role to make up for these deficiencies. But long term use can lead to adverse reactions or uncomfortable feeling. This is primarily caused by its properties differ with human hair. In particular, nanotribological characterizations (roughness, friction force and adhesive force) of synthetic hair surface are dissatisfy with the needs of normal hairs. This paper presents the experiments on nanotribological characterizations measurements of human hairs (coloring hair, permed hair and common hair) in shampooing condition or without shampooing condition. Using atomic force microscopy (AFM) to find out a range of synthetic hair nanotribological characterizations which can correspond with natural hair. The measurements of nanotribological characterizations focus on surface roughness, friction force and adhesive force, and a new design of AFM probe was used for measuring the nanotribological characterizations.

Effects of the Position of Potential Probe on Ground Resistance Measurements Using the Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전위보조전극 위치의 영향)

  • 이복희;어주홍;김성원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.97-104
    • /
    • 2001
  • The effects of the position of potential probe on the measurements of the ground resistance in the fa11-of-potential method are described. The ground resistance is theoretically calculated by applying the 61.8[%] rule, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring potential and current probes in on-site test might not be arranged on the straight line with adequate distance because there are building, roadblock construction and other establishments. Provided that the grounding electrode to be measured and the measuring potential probes are out of position on the straight line, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. In this work, measurements were focused on the grounding electrode system made by the ground rods of 2.4 m long. The measuring error was increased with increasing the angle which is made by the 3-points of the grounding electrode to be measured, the potential anti current probes, and it was a negative. That is, all of the measured ground resistances ware less than the true ground resistance.

  • PDF

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

Effects of Maximum Probe Spacing of Wenner Method on Substation Grounding (변전소 접지설계를 위한 대지저항율 측정시 전극간격이 해석결과에 미치는 영향)

  • Choi, J.K.;Kee, H.C.;Jung, G.J.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2355-2357
    • /
    • 1999
  • Estimating equivalent soil model which represents an actual soil structure and its electrical characteristics, is extremely improtant for good substation grounding system design and analysis. Since the equivalent soil model is deduced based on the measured apparent soil resistivity - generally obtained from Wenner's 4-point method, reasonable and accurate measuring technique and procedure guarantee good grounding system design and analysis. The paper aims to show the importance of reasonable enough probe spacing by presenting the influence of soil modelling to estimation and measurement of grounding resistance of substation grounding grid.

  • PDF

Development of an Automatic Tool Compensation System for M/C (머시닝센터용 자동공구보정시스템의 개발)

  • 정상화;신현성;김현욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.4
    • /
    • pp.48-54
    • /
    • 2001
  • The tool wear that is developed by long-term machining in mold manufacturing with machining center makes a severe influence to the accuracy and the surface roughness. in this reason, tool-wear supervising system which has guaranteed high accuracy and high speed is needed to improve the measurement quality. Touching probe and touch sensor are widely used to measure the tool profile at on-machine measurement. In this paper, using the newly developed electric touch point measuring system, the Automatic Tool Compensation System is developed to correct the error of tool diameter resulted from the wear, and the operating method of this system is also provided.

  • PDF