• Title/Summary/Keyword: 3rd Harmonic

Search Result 119, Processing Time 0.025 seconds

A Study on Coupled Vibrations of Diesel Engine Propulsion Shafting (3rd Report : Vibration by Propeller Exciting and its Countermeasure) (디젤기관 추진 축계의 연성진동에 관한 연구 (제3보 : 프로펠러 기진에 의한 진동과 그 대책))

  • 전효중;이돈출;김의간;김정렬
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.173-179
    • /
    • 2001
  • The torsional or axial critical vibration of the order coinciding with the number of propeller blades is simultaneously excited by the harmonic tangential or radial forces acting on the crank shaft and by the harmonic of the same order from the propeller. The exciting torque of propeller is relatively small comparing with that of crank side, but the exciting force of propeller rather larger than that of crank shaft. With this situation, the exciting force of propeller cannot neglect if the axial vibration of propulsion shafting is calculated. With the propeller in its optimal angular position, i.e. its excitation effect opposed to that of the engine, the stresses at the critical revolution will largely cancel themselves out. In this paper, a method of optimizing the angular propeller position with regard to torsional and axial vibration is studied. The optimal relative angle is determined theoretically by calculation results of coupled torsional-axial vibration.

  • PDF

Design of Broadband 12GHz Active Frequency Multiplier (광대역 특성을 갖는 12GHz 능동 주파수 체배기 설계)

  • Jeon, Jong-Hwan;Kim, Tae-Yong;Choi, Won;Oh, Chung-Gyun;Koo, Kyung-Heon
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.72-76
    • /
    • 2003
  • In this paper, active frequency doubler with broadband characteristics and unconditional stability from 6GHz to 12GHz was designed and fabricated using PHEMT. The designed frequency multiplier has a bias point near pinch-off and a proposed RC circuit between bias line and input matching network for the improvement of stability. With 0dBm input power, second harmonic of 1.7dBm at 12GHz, - 27.5dBc suppression of 6GHz fundamental, -18dBc suppression of 18GHz 3rd harmonic and the output bandwidth of 1.8GHz have been measured.

  • PDF

Study about varying aspects of flicker indices by load fluctuating in electric railway system (전기철도환경하에서 부하변동에 따른 플리커지수의 변화양상에 대한 연구)

  • Lee Kang-Won;Kim Myung-Yong;Baik Kwang-Sun;Kim Won-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.655-659
    • /
    • 2005
  • The environment. of electric railway has, included both fast and slow load variation, which may occur in the office or maintenance factory or running electric train. This paper investigated flicker indices according to voltage fluctuations on three different situations; The base office in new subway in the daytime and night time, inside of electric train running in conventional subway. And also the variations of harmonic frequencies(2nd, 3rd, 5th) with rime were measured at the same time. Flicker index is a good tool for evaluating the voltage fluctuation quantitatively and show some relationship with even harmonic frequencies produced by the voltage fluctuation when the electric train is running on the railway.

  • PDF

A Hybrid Active Power Filter for Electric-Railway Systems Using Multi-Level Inverters (멀티레벨 인버터를 이용한 전기철도용 하이브리드 능동 전력필터)

  • 김윤호;김수홍;이강희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.339-344
    • /
    • 2004
  • This paper proposes transformerless power conversion system consisting of a single-phase diode rectifier and a shunt hybrid filter for the electric-railway system. The hybrid filter consists of a single tuned LC filter per a phase and a low-rated NPC type multi-level inverter. Compared with conventional active filters. transformers are not used. Also, LC filter works as not only a harmonic filter tuned at the 3rd harmonic frequency but also a switching-ripple filter. The rating of the active filter can be decreased by using a NPC type multi-level inverter. The simulation results confirm the validity of the system.

Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement (누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향)

  • Kil, Gyung-Suk;Han, Joo-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

Design of the 1.8GHz Strip-line Isolator with high attenuations at harmonic band (고조파 대역에서 높은 감쇄를 갖는 1,8GHz 대역 스트립라인 아이솔레이터 설계)

  • Yoo, Young-Cheol;Eom, Ki-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.795-802
    • /
    • 2011
  • In this paper, the detailed design procedure of the Y-junction stripline isolator self-contained the filter circuit in the center conductor in order to maximize attenuations below value of 30 dB at 3rd order harmonics is presented. The HFSS is used to simulate 1.8GHz band isolator and the results are compared with the measurement data. These results confirms that the designed stripline isolator is effective in achieving high attenuation above -30 dB at 3rd order harmonics. And it is obtained that the harmonic band of isolator using the ferrite of 0.16T is moved far from operating frequency more 1.2 GHz than one using the ferrite of 0.12T.

Development of a 2.14-GHz High Efficiency Class-F Power Amplifier (2.14-GHz 대역 고효율 Class-F 전력 증폭기 개발)

  • Kim, Jung-Joon;Moon, Jung-Hwan;Kim, Jang-Heon;Kim, Il-Du;Jun, Myoung-Su;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.873-879
    • /
    • 2007
  • We have implemented a highly efficient 2.14-GHz class-F amplifier using Freescale 4-W peak envelope power(PEP) RF Si lateral diffusion metal-oxide-semiconductor field effect transistor(LDMOSFET). Because the control of the all harmonic contents is very difficult, we have managed only the $2^{nd}\;and\;3^{rd}$ harmonics to obtain the high efficiency with simple harmonic control circuit. In order to design the harmonic control circuit accurately, we extracted the bonding wire inductance and drain-source capacitance which are dominant parasitic and package effect components of the device. And then, we have fabricated the class-F amplifier. The measured drain and power-added efficiency are 65.1 % and 60,3 %, respectively.

Characteristics analysis of PFC boost converter with soft switching for harmonics reduction (고조파 저감을 위한 소프트 스위칭 승압형 PFC컨버터의 특성해석)

  • 김봉규
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.150-154
    • /
    • 2000
  • This paper proposes PFC boost converter with soft switching for harmonics decrement and analyzes characteristics of PFC boost converter. In this technique power factor correction(PFC) is usually obtained by operating the PFC stage in the discontinuous current mode(DCM) Switching devices are operated for reducing current stress and electronical noise. As a result eliminate 3rd harmonic component and high power factor(PF) of the input line are verified by characteristics analysis and experimental results.

  • PDF

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.