• Title/Summary/Keyword: 3d Scan

Search Result 879, Processing Time 0.031 seconds

Development of the Automated Ultrasonic Testing System for Inspection of the flaw in the Socket Weldment (소켓 용접부 결함 검사용 초음파 자동 검사 장비 개발)

  • Lee, Jeong-Ki;Park, Moon-Ho;Park, Ki-Sung;Lee, Jae-Ho;Lim, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.275-281
    • /
    • 2004
  • Socket weldment used to change the flow direction of fluid nay have flaws such as lack of fusion and cracks. Liquid penetrant testing or Radiography testing have been applied as NDT methods for flaw detection of the socket weldment. But it is difficult to detect the flaw inside of the socket weldment with these methods. In order to inspect the flaws inside the socket weldment, a ultrasonic testing method is established and a ultrasonic transducer and automated ultrasonic testing system are developed for the inspection. The automated ultrasonic testing system is based on the portable personal computer and operated by the program based Windows 98 or 2000. The system has a pulser/receiver, 100MHz high speed A/D board, and basic functions of ultrasonic flaw detector using the program. For the automated testing, motion controller board of ISA interface type is developed to control the 4-axis scanner and a real time iC-scan image of the automated testing is displayed on the monitor. A flaws with the size of less than 1mm in depth are evaluated smaller than its actual site in the testing, but the flaws larger than 1mm appear larger than its actual size on the contrary. This tendency is shown to be increasing as the flaw size increases. h reliable and objective testing results are obtained with the developed system, so that it is expected that it can contribute to safety management and detection of repair position of pipe lines of nuclear power plants and chemical plants.

The Diagnosis and Treatment of Osteoporosis (골다공증의 진단과 치료)

  • Moon, Jun-Sung;Won, Kyu-Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2008
  • Osteoporosis, a disease characterized by low bone mass and microarchitectural deterioration of bone tissue leading to enhanced bone fragility and fracture risk, is a major public health problem. The diagnostic methods for osteoporosis include simple radiography, bone scan, DXA (Dual energy X-ray Absortiometry) and biochemical markers of bone turnover. Optimal treatment and prevention of osteoporosis require modification of risk factors, particularly smoking cessation, adequate physical activity, and attention to diet, in addition to pharmacologic intervention. The estrogens and raloxifene both prevent bone loss in postmenopausal women, and the estrogens probably also decrease the risk of first fracture. There is good evidence that raloxifene prevents further fractures in postmenopausal women who already have had fractures and some evidence that estrogen does as well. Bisphosphonate prevents bone loss and reduces fractures in healthy and osteoporotic postmenopausal women and in osteoporotic men as well. Risedronate is more potent and has fewer side effects than alendronate and reduces the incidence of fractures in osteoporotic women. Calcitonin increases bone mineral density in early postmenopausal women and men with idiopathic osteoporosis, and also reduces the risk of new fractures in osteoporotic women. All of the agents discussed above prevent bone resorption, whereas teriparatide and strontium increase bone formation and are effective in the treatment of osteoporotic women and men. New avenues for targeting osteoporosis will emerge as our knowledge of the regulatory mechanisms of bone remodeling increases, although issues of tissue specificity may remain to be addressed.

  • PDF

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Expert Opinion Questionnaire About Chest CT Scan Using A Negative Pressure Isolation Strecher in COVID-19 Patients: Image Quality and Infection Risk (COVID-19 환자에서 음압격리들것을 이용한 흉부 CT 검사에 대한 전문가 의견 설문: 영상품질과 감염위험)

  • Kwang Nam Jin;Bo Da Nam;Jaemin Shin;Sung Ho Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.891-899
    • /
    • 2023
  • Purpose To survey perceptions of certified physicians on the protocol of chest CT in patients with coronavirus (COVID-19) using a negative pressure isolation stretcher (NPIS). Materials and Methods This study collected questionnaire responses from a total of 27 certified physicians who had previously performed chest CT with NPIS in COVID-19 isolation hospitals. Results The nine surveyed hospitals performed an average of 116 chest CT examinations with NPIS each year. Of these, an average of 24 cases (21%) were contrast chest CT. Of the 9 pulmonologists we surveyed, 5 (56%) agreed that patients who showed abnormalities in serum D-dimer required contrast chest CT. All 9 surveyed radiologists agreed that the image quality of the chest CT with NPIS was sufficient for CT image interpretation regarding pneumonia or pulmonary embolism. Furthermore, in our 9 surveyed infectionologists, 5 (56%) agreed that a risk of secondary infection in the CT room after temporary opening of NPIS could be prevented through a process of disinfection. Conclusion Experienced physicians considered that the effects of NIPS on chest CT image quality was minimal in patients with COVID-19, and the risk of CT room contamination was easily controlled.

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

A study about sculpture characteristic of SKD61 tool steel fabricated by selective laser melting(SLM) process (SLM 공정으로 제작된 SKD61 공구강의 조형 특성에 관한 연구)

  • Yun, Jaecheol;Choe, Jungho;Kim, Ki-Bong;Yang, Sangsun;Yang, Dong-Yeol;Kim, Yong-Jin;Lee, Chang-Woo;Yu, Ji-Hun
    • Journal of Powder Materials
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2018
  • In this study, two types of SKD61 tool-steel samples are built by a selective laser melting (SLM) process using the different laser scan speeds. The characteristics of two kinds of SKD61 tool-steel powders used in the SLM process are evaluated. Commercial SKD61 tool-steel power has a flowability of 16.68 sec/50 g and its Hausner ratio is calculated to be 1.25 by apparent and tapped density. Also, the fabricated SKD61 tool steel powder fabricated by a gas atomization process has a flowability of 21.3 sec/50 g and its Hausner ratio is calculated to be 1.18. Therefore, we confirmed that the two powders used in this study have excellent flowability. Samples are fabricated to measure mechanical properties. The highest densities of the SKD61 tool-steel samples, fabricated under the same conditions, are $7.734g/cm^3$ (using commercial SKD61 powder) and $7.652g/cm^3$ (using fabricated SKD61 powder), measured with Archimedes method. Hardness is measured by Rockwell hardness testing equipment 5 times and the highest hardnesses of the samples are 54.56 HRC (commercial powder) and 52.62 HRC (fabricated powder). Also, the measured tensile strengths are approximately 1,721 MPa (commercial SKD61 powder) and 1,552 MPa (fabricated SKD61 powder), respectively.

Replacement of Obstructed Extracardiac Conduits with Autologous Tissue Reconstructions (Peel operation); Early and Midterm Results (심외도관 협착 환자에서 자가조직을 이용한 재수술(Peel 수술); 조기 및 중기성적)

  • Sung, Si-Chan;Chang, Yoon-Hee;Lee, Choong-Won;Park, Chin-Su;Lee, Hyoung-Doo;Ban, Ji-Eun;Choo, Ki-Seok
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.193-199
    • /
    • 2007
  • Background: Reoperation is usually required for a right ventricle to pulmonary artery conduit obstruction caused by valve degeneration, conduit peel formation or somatic growth of the patient. An autologous tissue reconstruction (peel operation), where a prosthetic roof is placed over the fibrotic tissue bed of the explanted conduit, has been used to manage conduit obstructions at our institute since May 2002. Herein, the early and midterm results are evaluated. Material and Method: Between May 2002 and July 2006, 9 patients underwent obstructed extracardiac conduit replacement with an autologous tissue reconstruction, at a mean of 5.1 years after a Rastelli operation. The mean age at reoperation was $7.5{\pm}2.4$ years, ranging from 2.9 to 10.1 years. The diagnoses included 6 pulmonary atresia with VSD, 2 truncus arteriosus and 1 transposition of the great arteries. The preoperative mean systolic gradient was $88.3{\pm}22.2mmHg$, ranging from 58 to 125 mmHg. The explanted conduits were all Polystan valved pulmonary conduit (Polystan, Denmark). A bioprosthetic valve was inserted in 8 patients, and a monocusp ventricular outflow patch (MVOP) was used in 1 patient. The anterior wall was constructed with a Gore-Tex patch (n=7), MVOP (n=1) and bovine pericardium (n=1). Pulmonary artery angioplasty was required in 5 patients and anterior aortopexy in 2. The mean cardiopulmonary bypass time . was 154 minutes, ranging from 133 to 181 minutes; an aortic crossclamp was not performed in all patients. The mean follow-up duration was 20 months, ranging from 1 to 51 months. All patients were evaluated for their right ventricular outflow pathway using a 3-D CT scan. Resuit: There was no operative mortality or late death. The mean pressure gradient, assessed by echocardiography through the right ventricular outflow tract, was 20.4 mmHg, ranging from 0 to 29.6 mmMg, at discharge and 26 mmHg, ranging from 13 to 36 mmHg, at the latest follow-up (n=7, follow-up duration >1 year). There were no pseudoaneurysms, strictures or thrombotic occlusions. Conclusion: A peel operation was concluded to be a safe and effective re-operative option for an obstructed extracardiac conduit following a Rastelli operation.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

THE EFFECT OF FLUORIDE VARNISH AND ACIDULATED PHOSPHATE FLUORIDE GEL ON ARTIFICIAL CARIES LESION - A MICROCOMPUTED TOMOGRAPHIC STUDY - (Fluoride Varnish와 Acidulated Phosphate Fluoride Gel이 인공우식 병소에 미치는 영향에 대한 미세전산화 단층 촬영을 이용한 연구)

  • Moon, Sung-Kwon;Lee, Jae-Cheoun;Kim, Young-Jae;Lee, Sang-Hoon;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.212-222
    • /
    • 2004
  • The application of acidulated phosphate fluoride gel(APF) and fluoride varnishes are the most common topical fluoride therapy. The purpose of this in vitro study was to compare the remineralization effects of two topical fluoride agents, APF gel and fluoride varnish with microtomograph and 3D image analyzer without sample preparation and chemical fixation. For the purpose of the study, the artificial caries lesion was caused on the caries-free permanent pre molar and 48 specimens were divided into three groups each containing 16 specimens No application was performed on group 1, which acted as control group. Group 2 was treated with APF gel and was removed after a minute. Group 3 was treated with the topical application of fluoride varnish and removed after 45 minutes. Each specimen was placed into a closed container with 50ml of a artificial saliva during three months and the 3D images of the remineralization area were taken using the SkyScan each month. Using the density-measuring program in V $works^{TM}$, the density value of the remineralization area was measured. The following results were obtained: 1. All groups demonstrated an increase in the density of artificial caries lesion with time. 2. The density was significantly higher in APF gel and fluoride varnish group than control group at 1 month, 2 months, 3 months after the treatment(P<0.05). 3. The difference of the density between that "prior to treatment" and that "1 month after treatment" in Group 2 and Group 3 was significantly higher than that of Group 1 and, the difference of the density between that "1 month after treatmen" and that "2 month after treatment" in Group 3 was significantly higher than that of Group 1 and 2(P<0.05). 4. The fluoride varnish was more effective after 2 and 3 months and continuous than the APF gel.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES (하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구)

  • Ku, Je-Hoon;Kim, Il-Kyu;Chang, Jae-Won;Yang, Jung-Eun;Sasikala, Balaraman;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.