• Title/Summary/Keyword: 3V

Search Result 24,240, Processing Time 0.059 seconds

Study on the Electrical Conductivity and Catalytic Property by Structural Change of 70V2O5-10Fe2O3-13P2O5-7B2O3 Glass with Crystallization

  • Jeong, Hwa-Jin;Cha, Jae-Min;Ryu, Bong-Ki
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.5
    • /
    • pp.406-412
    • /
    • 2017
  • $70V_2O_5-10Fe_2O_3-13P_2O_5-7B_2O_3$ glasses were prepared to study the electrical conductivity and catalytic properties of the structural change with crystallization. The structural changes were analyzed by determining the molecular volume from the sample density; using X-Ray Diffraction (XRD) analysis, which indicated that $V_2O_5$, $VO_2$ and $B_2O_3$ crystals in heat-treated more than 1h samples. Especially a new crystalline phase of non-stoichiometric $Fe_{0.12}V_2O_5$ was formed after 6 h heat treatment. The V-O bonding change after crystallization was analyzed by Fourier Transform Infrared Spectroscopy (FTIR); V ion change from $V^{5+}$ to $V^{4+}$ was shown by XPS. Conductivity and catalytic properties were examined based on the polaronic hopping of V and Fe ions, which exhibited different valence states with crystallization.

Threshold Voltage Control of Pentacene Thin-Film Transistor with Dual-Gate Structure

  • Koo, Jae-Bon;Ku, Chan-Hoe;Lim, Sang-Chul;Lee, Jung-Hun;Kim, Seong-Hyun;Lim, Jung-Wook;Yun, Sun-Jin;Yang, Yong-Suk;Suh, Kyung-Soo
    • Journal of Information Display
    • /
    • v.7 no.3
    • /
    • pp.27-30
    • /
    • 2006
  • This paper presents a comprehensive study on threshold voltage $(V_{th})$ control of organic thin-film transistors (OTFTs) with dual-gate structure. The fabrication of dual-gate pentacene OTFTs using plasma-enhanced atomic layer deposited (PEALD) 150 nm thick $Al_{2}O_{3}$ as a bottom gate dielectric and 300 nm thick parylene or PEALD 200 nm thick $Al_{2}O_{3}$ as both a top gate dielectric and a passivation layer was investigated. The $V_{th}$ of OTFT with 300 nm thick parylene as a top gate dielectric was changed from 4.7 V to 1.3 V and that with PEALD 200 nm thick $Al_{2}O_{3}$ as a top gate dielectric was changed from 1.95 V to -9.8 V when the voltage bias of top gate electrode was changed from -10 V to 10 V. The change of $V_{th}$ of OTFT with dual-gate structure was successfully investigated by an analysis of electrostatic potential.

Occurrence and Distribution of Viruses Infecting Pepper in Korea

  • Choi, Gug-Seoun;Kim, Jae-Hyun;Lee, Dong-Hyuk;Kim, Jeong-Soo;Ryu, Ki-Hyun
    • The Plant Pathology Journal
    • /
    • v.21 no.3
    • /
    • pp.258-261
    • /
    • 2005
  • We conducted a survey on pepper virus diseases in 31 regions in Korea from November 2001 to December 2004. Using electron microscopy, test plant reaction, rapid immuno-filter paper assay (RIPA), reverse transcription-polymerase chain reaction (RT-PCR) and/or analysis of viral nucleotide sequences, we found a number of viruses from 1,056 samples that we collected. These included Cucumber mosaic virus (CMV), Pepper mottle virus (PepMoV), Pepper mild mottle virus (PMMoV), Broad bean wilt virus 2 (BBWV2), Tobacco mild green mosaic virus (TMGMV), and Tomato spotted wilt virus (TSWV). Of the samples analyzed, $343(32.5\%)$ were infected with CMV, $209(19.8\%)$ with PepMoV, $141(13.4\%)$ with PMMoV, $12(1.1\%)$ with BBWV2, $40(3.8\%)$ with TMGMV, $5(0.5\%)$ with TSWV, $153(14.5\%)$ with CMV and PepMoV, $54 (5.1\%)$ with CMV and PMMoV, $31(2.9\%)$ with PepMoV and PMMoV, $3(0.3\%)$ with CMV and BBWV2, $1(0.1\%)$ with CMV, PepMoV and BBWV2, $8(0.8\%)$ with CMV, PepMoV and PMMoV, and $30 (2.8\%)$ samples were infected with viruses which were not identified. CMV was the most predominant virus in all inspected fields and the number of the samples infected with PMMoV was relatively low as compared PepMoV infection level in pepper. TMGMV was only found in the southern part of Korea, while TSWV was isolated in Anyang and Yesan. However, we did not encounter in this survey the Alfalfa mosaic virus (AMV), Potato virus Y (PVY), Tobacco mosaic virus (TMV), and Pepper vein chlorosis virus (PVCV).

A study on the analysis of rare earth elements by differential pulse anode stripping voltammetry (시차펄스 양극벗김 전압-전류법에 의한 희토류 원소의 분석에 관한 연구)

  • Kim, Jae-Kyun;Cha, Ki-Won
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.369-375
    • /
    • 2005
  • The differential pulse anode stripping voltammograms of some rare earth elements and their complexes with catechol have been investigated in various pH and electrolytes. In a 0.1 M LiCl and pH 5.3 solution, $Euv^{3+}$ and $Pr^{3+}$ showed a single oxidation peak at -0.2 V and the oxidation currents were linearly increased with the concentration of those ions. $Tm^{3+}$, $Tb^{3+}$, $Yb^{3+}$ and $Sm^{3+}$ showed two oxidation peaks at -0.5 V and -0.2 V and the oxidation currents at -0.5 V were increased with the concentration increase of those ions. The linear range of those calibration curves was in 1 ppm-10 ppm. In the case of voltammograms of catechol complexes of rare earth elements, $Tb^{3+}$-catechol and $Eu^{3+}$-catechol complex showed a single oxidation peak at -0.95 V and -0.65V, respectively and $Sm^{3+}$-catechol, $Pr^{3+}$-catechol, $Tm^{3+}$-catechol and $Yb^{3+}$-catechol complexes showed two oxidation peaks. The linear range of the calibration curves of those complex was 0.1 ppm~1.0 ppm.

Design of A 3.3V, 400 MBPS IEEE-1394 Physical Layer Transceiver (3.3V, 400MBPS IEEE-1394 물리층 트랜시버의 설계)

  • 황인철;한상찬송병준김수원
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.783-786
    • /
    • 1998
  • We designed a 3.3 V, 400 Mbps IEEE-1394 physical layer transeiver on 0.6um 1P3M CMOS process. The transceiver drives a twisted pair cable of which differential impedance is 110 $\Omega$ so that differential amplitude reaches 200 mV at 400 Mbps and restores this small signal to rail-to-rail. Also, the transceiver arbitrates the interface among nodes on a bus configuration and supports both synchronous interface and asynchronous interface.

  • PDF

Preparation and Electrical Properties of Electro-conducting Glasses Containing $\textrm{V}_{2}\textrm{O}_{5}$ ($\textrm{V}_{2}\textrm{O}_{5}$계 전자 전도성 유리의 제조 및 전기적 특성)

  • Kim, Il-Gu;Park, Hui-Chan;Son, Myeong-Mo;Lee, Heon-Su
    • Korean Journal of Materials Research
    • /
    • v.7 no.1
    • /
    • pp.81-88
    • /
    • 1997
  • Vanadate glasses using $B_2O_3$ as a network former and with CuO additive were mainly investigated in relation to electrical properties. Crystalline phases formed by heat-treatment in each composition were examined and dc electrical conductivity changes of the glasses were analyzed. Crystalline phases were identified as $V_3O_5,\;a-CuV_2O_6\;and\;{\beta}-CuV_2O_6$ by XRD analysis. Crystallization degrees of $V_2O_5$ and ${\beta}-CuV_2O_6$ were little changed with heat-treatment time, but those of ${\alpha}u-CuV_2O_6$ were changed sharply with heat-treatment time. The more crystallization of ${\alpha}u-CuV_2O_6$ occurred, the higher electrical conductivity was observed. Electrical conductivities with $10^{-2}~10^{-4}/{\Omega}/cm$ at room temperature(303K) could be obtained by controlling the glass compositions. The electrical conductivities were increased with increasing of $V_20_5$ content and decreasing of alkality($CuO/B_2O_3$). In this study, electron was proved to be charge carrier by seebeck coefficient measurement. Accordingly, the glasses are believed to be n-type semiconductor. Calculated activation energies for the conduction were in the range 0.098-0.124 eV. Electrical conduction mechanism was small polaron hopping without showing variable range hopping in the temperature range $30~200^{\circ}C$.

  • PDF

Studies on Electrocardiogram of the Normal Korean Native Goat II. Waveforms and Amplitudes of the Unipolar Precordial Chest Leads (정상적인 한국 흑염소의 심전도에 관한 연구 II. 담부단극유도의 파형과 전위)

  • 최인혁;김기주;윤여백;서석열;김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.338-348
    • /
    • 1997
  • The electrocardiographic (ECG) parameters on unipolar precordial chest leads in the normal Korean native goat of 343 heads as to CV$_{6}$LU, CV$_{6}$LL CV$_{6}$RU, CV$_{6}$RL and V10 have been measured with a 3-channel Elertrocardiograph and computed, analysed. All wave types as positive, negatives biphasic and flatting in the P and T waves appeared in all leads but any special wave type was not shown more than 60%. Average amplitudes with the highest frequent rate in P wave were 81.4$\pm$32.0 $\mu $V (52.3%), 59.6$\pm $ 27.5 $\mu $V (50.5 %) of Positive type in leads CV$_{6}$LU and CV$_{6}$LL, and -5fl.5$\pm $22.6 $\mu $V (44.0%) of negative type in leads VIO, and 51.3% and 44% of flatting type in leads CV$_{6}$RU and CV$_{6}$RL, but flatting type of clinic form appeared frequent rate between 53% and 77% in all leads. In T wave, average amplitudes with the highest frequent rate were 265.0$\pm $97.1 $\mu $V (54.0%) and 212.2$\pm $90.7 $\mu $V (57.0%) of positive type in leads CV$_{6}$LL and CV$_{6}$RL, and -252.8$\pm $90.7 $\mu $V (56.6%) of negative in lead V10, but amplitudes of T waves that positive and negative type appeared similarity frequent ra蛇 ware 208.7$\pm $99.7 $\mu $V (42.1%), -159.0$\pm $81.6 (43.8%) in lead CV$_{6}$LU and 153.2$\pm $139.0 $\mu $V (47.3%), -130.0$\pm $81.4 (43.2%) in lead CV$_{6}$RU, Amplitudes of QRS complex wave forms showed the highest frequent rate were 218.2$\pm $96.4 $\mu $V (47.8%), 308.3$\pm $135.2 $\mu $V (46.8 %), 232.8$\pm $126.5 $\mu $V (58.5%) and 225.3$\pm $89.6 $\mu $V (54.9%) of R type in the leeds CV$_{6}$LU, CV$_{6}$LL, CV$_{6}$RU and CV$_{6}$RL, and were -92.5$\pm $79.1 $\mu $V,479.0 $\pm $116.6 $\mu $V (33.2%) and 212.1 $\pm $86.7 $\mu $V (32.8%) of QR and 05 type in the lead V10. These results in the V10, CV$_{6}$RU, CV$_{6}$RL, CV$_{6}$LU, CV$_{6}$LL. may be not starve to purpose of unipolar precordial chest leads.

  • PDF

Study on Mo(V) Species, Location and Adsorbates Interactions in MoH-SAPO-34 by Employing ESR and Electron Spin-Echo Modulation Spectroscopies (ESR, ESEM을 이용한 이온 교환된 MoH-SAPO-34에 대한 Mo의 화학종, 위치 및 흡착상호작용에 관한 연구)

  • Back, Gern-Ho;Jang, Chang-Ki;Ru, Chang-Kuk;Cho, Young-Hwan;So, Hyun-Soo;Kevan, Larry
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.1
    • /
    • pp.26-36
    • /
    • 2002
  • A solid-state reaction of $MoO_3$ with as-synthesized H-SAPO-34 generated paramagnetic Mo(V) species. The dehydration resulted in weak Mo(V) species, and subsequent activation resulted in the formation of Mo(V) species such as $Mo(V)_{5c}$ and $Mo(V)_{6c}$ that are characterized by ESR. The data of ESR and ESEM show the oxomolybdenum species, to be $(MoO_2)^+$ or $(MoO)^{3+}$. The $(MoO_2)^+$ species seems to be more probable. Since H-SAPO-34 has a low framework negative charge, $(MoO)^{3+}$ with a high positive charge can not be easily stabilized. A solution reaction between the solution of silico-molybdic acid and calcined H-SAPO-34 resulted in only $(MoO_2)^+$ species. A rhombic ESR signal is observed on adsorption of $D_2O$, $CD_3OH$, $CH_3Ch_2OD$ and $ND_3$. The Location and coordination structure of Mo(V) species has been determined by three-pulse electron spin-echo modulation data and their simulations. After the adsorption of methanol, ethylene, ammonia, and water for MoH-SAPO-34, three molecules, one molecule, one and one molecule, respectively, are directly coordinated to $(MoO_2)^+)$.

LINEAR MAPPINGS ON LINEAR 2-NORMED SPACES

  • White Jr. Albert;Cho, Yeol-Je
    • Bulletin of the Korean Mathematical Society
    • /
    • v.21 no.1
    • /
    • pp.1-5
    • /
    • 1984
  • The notion of linear 2-normed spaces was introduced by S. Gahler ([8,9,10,11]), and these space have been extensively studied by C. Diminnie, R. Ehret, S. Gahler, K. Iseki, A. White, Jr, and others. For nonzero vectors x,y in X, let V(x,y) denote the subspace of X generated by x and y. A linear 2-normed space (X,v) is said to be strictly convex ([3]) if v(x+y,z)=v(x,z)+v(y+z) and z not.mem.V(x,y) imply that y=ax for some a>0. Some characterizations of strict convexity for linear 2-normed spaces are given in [1,3,4,5,12]. Also, a linear 2-normed space (X,v) is said to be strictly 2-convex ([6]) if v(x,y)=v(x,z)=v(y,z)=1/3v(x+z, y+z)=1 implies that z=x+y. These space have been studied in [2,4,6,13]. It is easy to see that every strictly convex linear 2-normed space is always strictly 2-convex but the converse is not necessarily true. Throughout this paper, let (X,v) denote a linear 2-normed space.

  • PDF

Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli (광 자극에 대한 향어의 심전도)

  • 양용림;김영기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The authors examined the response of electrocardiogram (ECG) of Mirror carp, Cyprinus carpio [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli (10, 100, and 400 lux) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes. The results which are divided into by day and by night and then analyzed by fishes conditions are as follows : 1. Mirror carps reached a stable condition 5 minutes after anesthesia. In this condition, the average heart rate was 64.9 beat/min by day and 65.3 beat/min by night. And the average action potential was 36.9 nV by day and 32.9 nV by night. 2. The average heart rate by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 68.7 beat/min by day and 46.0 beat/min by night, in case of 100 lux 53.4 beat/min by day and 44.1 beat/min by night, and in case of 400 lux 53.2 beat/min by day and 40.1 beat/min by night. 2) In a recovery condition, in case of 10 lux 67.9 beat/min by day and 57.2 beat/min by night, in case of 100 lux 68.8 beat/min by day and 61.0 beat/min by night, and in case of 400 lux 69.6 beat/min by day and 63.6 beat/min by night. 3. The average action potential by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 59.1 nV by day and 24.0 nV by night, in case of 100 lux 26.8 nV by day and 45.6 nV by night, and in case of 400 lux 71.7 nV by day and 14.4 nV by night. 2) In a recovery condition, in case of 10 lux 38.8 nV by day and 27.3 nV by night, in case of 100 lux 29.0 nV by day and 39.3 nV by night, and in case of 400 lux 66.4 nV by day and 21.4 nV by night.

  • PDF