• Title/Summary/Keyword: 3Door

Search Result 602, Processing Time 0.025 seconds

The Study on the Effect of Passenger Coach temperature When Aircurtains Installed At Electrical Rolling Stock At Entrance Door (전동차 출입문에 에어커튼 설치시 객실 온도 변화 연구)

  • Ahn Jong-Kon;Kim Chul-Ho;Park Duk-Sin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.489-496
    • /
    • 2004
  • The effect of airconditioning and heating system when aircurtains installed in subway electrical rolling stock at entrance door. It blocks cold/hot air of outside. It is good for health with its blocking effect against dusts exhaust fumes, odor bugs and smoke from outside. It always maintains clean and pleasant atmosphere inside. It helps you to have health with its ever-equal temperature distribution at inside. It saves lots of maintenance cost for heating/cooling (about 86$\%$) since it cuts the loss of hot air under heating as well as of cold air under air-conditionin. Customers can feel pleasant go in and out (better than before) with the door. It is an indispensable product for the employers to cut the cost. It makes customers feel pleasant near doors, since it isnt influenced by temperature difference of cold/hot air when the door opens/closes. In electrical rolling stock passenger temperature is a lot different from that the door opens/closes. One of the main aims is to create an acceptable thermal environment without draught problem. Temperature, gradients when aircurtains installed in subway electrical rolling stock at entrance door have been studied. And the temperature measured at 0.1, 0.5, 1.3, 1.7m above the floor. It has been found that temperature, with large fluctuations caused more draught influence.

  • PDF

Performance Evaluation on Blast-resistant of Gastight Door using Numerical Simulation (수치해석을 활용한 가스차단문의 폭발압력저항 성능평가)

  • Shin, Baegeun;Kim, Jiyu;Kim, Euisoo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.1
    • /
    • pp.27-33
    • /
    • 2022
  • As the scale of explosions diversifies along with the expansion of gas handling and storage facilities, studies on explosion-proof facilities in preparation for accidents is being actively conducted. The gastight door blocks the expansion pressure caused by blast waves or internal fires, and at the same time protects the personnel and equipment inside. For gastight doors, the regulations related to explosion-proof design are not clearly presented, and studies on the explosion pressure resistance performance evaluation of the facility are insufficient. In this study, the gastight door was modeled in a 3D shape with reference to the regulation ASTM regarding the gastight door standard. Afterwards, evaluation for blast-resistant performance of gastight door using Numerical simulation was evaluated by using ANSYS Explicit Dynamics to compare the deformation.

Experimental and Numerical Analyses of Unsteady Tunnel Flow in Subway Equiped with Platform Screen Door System (스크린도어가 설치된 지하철에서 열차운행에 의한 비정상유동의 실험 및 수치적 해석)

  • Kim Jung-Yup;Kim Kwang-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.103-111
    • /
    • 2006
  • To optimize the ventilation and smoke control systems in subway equipped with platform screen door, the technology to analyze the unsteady tunnel flow caused by running of train should be developed. The development of model experiment and numerical analysis technique with relation to unsteady flow of subway were presented. The pressure and air velocity changes in 1/20-scaling experiment unit were measured and results were comparied to those of 3-D unsteady numerical analysis applied with sharp interface method. The experimental and numerical results were quantitatively similar and it would be reasonable to apply sharp interface method to analyze the unsteady flow in subway equipped with platform screen door.

A Study on the Development of Progressive Die and Forming Process for Asymmetric Automotive Door Striker (자동차용 비대칭 스트라이커의 순차이송금형 및 공정 개발에 관한 연구)

  • Youn, Jae-Woong;Kim, Hong-Seok
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.167-174
    • /
    • 2012
  • For high production rate of parts requiring multiple operations such as punching, blanking, or other operations are generally done with progressive dies. However, progressive die is generally limited to use for sheet metal forming due to the technical difficulties in rod or bulk material. This study proposes a new technique of progressive die and forming process for asymmetric automotive door striker, which is conventionally manufactured with separate tandem processes using solid rod. In order to design forming process and die, FEM simulation was performed to divide proper intermediate processes and analyze its formability. As a result, Forming processes were divided into 3 stages with upper and side punches and also, workpiece feeding and location mechanism was designed and manufactured in this study. Finally, forming tryouts were carried out by using the manufactured progressive die to verify the forming quality and productivity.

Development of position correction system of door mounting robot based on point measure: Part ll-Measurement and implementation (특정점 측정에 근거한 도어 장착 로봇의 위치 보정 시스템 개발: Part II - 측정및 구현)

  • Byun, Sung Dong;Kang, Hee Jun;Kim, Sang Myung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.42-48
    • /
    • 1996
  • In this paper, a position correction system of industrial robot for door-chassis assembly tast is developed in connection with the position correction algorithm shown in Part I. Tow notches and a hole of auto chassis are selected as the reference measure points and a vision based error detection algorithm is devised to measure in accuracy of less than 0.07mm. And also, the transformation between base and tool coordinates of the robot is shown to send the suitable correction quantities caaording to robot's option. The obtained algorithms were satisfactorily implemented for a real door-chassis model such that the system could accomplish visually acceptable door-chassis assembly task.

  • PDF

THE COMPARATIVE STUDY OF ROOT COVERAGE EFFECT OF DIFFERENT CONNECTIVE TISSUE OBTAINING METHODS (결합조직 채득방법에 따른 치은퇴축 회복의 비교연구)

  • Choi, Yong-Suk;Yim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.146-152
    • /
    • 1995
  • A mucogingival grafting procedure has been developed to cover denuded root surfaces. The subepithelial connective tissue graft is composed of a free connective tissue graft and an overlying pedicle graft. The source of connective tissue graft were trap door approach and thining of a full thickness palatal flap. The purpose of this study was compare a two different connective tissue obtaining method. In this study, where palatal pocket was present, pocket elimination was performed, and the tissue normally discarded after thinning of the palatal flap was used as a grafting material. The results were as follows : 1. The mean difference between trap door approach and thinning procedure for root coverage were $2.1{\pm}O.lmm$, $2.2{\pm}O.2mm$. 2. The mean difference between trap door approach and thinning procedure for pocket depth change were $O.2{\pm}O.lmm$, $O.2{\pm}O.2mm$. 3. The mean difference between trap door approach and thinning procedure for attachment gain were $2.1{\pm}O.2mm$, $2.4{\pm}O.2mm$. 4. The esthetics in recipient site, both color match and tissue contour, were acceptable to the patient in all cases. 5. Therefore, thinning procedure were similar to trap door approach in root coverage effect.

  • PDF

Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door (굴뚝효과와 외부출입문 개방을 고려한 부속실 제연)

  • Yongkwang Kim;Zudal Son;Seoyoung Kim;Hasung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.1
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

Plastic Flow Prediction of Automobile Door-Handle Using Injection Molding Simulation Programs (플라스틱 유동해석 프로그램을 이용한 자동차 도어 핸들의 유동예측)

  • 한성렬;강철민;유호종;정영득
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.295-298
    • /
    • 2004
  • Automobile door-handle is assembled with three parts that are base, skin and cover. Over-molding processing makes assembly of the base and skin. The skin part that was made by PVC polymer has various thickness. Plastic injection molding simulation of part including significant changed thickness as skin is an inaccuracy comparing with real injection molding. To solve this problem, two commercial flow prediction software that are Moldflow MPI and MAPS 3D were used in this study. Simulations were conducted for three types mesh. Taguchi method was applied for simulation experiments. It will be need to compare with simulation results and real over-molding behavior in the near future.

  • PDF

A Analysis on the Usage Status and Promotion of Multimodal Transport Logistics Terms in Incoterms, 2010 (Incoterms, 2010의 복합운송물류조건의 이용실태 분석과 활성화)

  • Song, Gyeeui
    • Journal of Korea Port Economic Association
    • /
    • v.29 no.1
    • /
    • pp.123-141
    • /
    • 2013
  • The purpose of this paper is to suggest a plan on promoting use of multimodal transport logistics terms in Incoterms, 2010. This study deals with the terms of three promotion factors which are a user's subjective factors, a trade transport logistics environment factors, and a term content factors. According to analysis results of the factors, a user's subjective factors(3.87 score) are scored the most ones of promotion factors of using multimodal transport logistics terms in Incoterms, 2010, to be compared with a trade transport logistics environment factors(3.60 score). with a term content factors(3.74 score). Therefore, first of all, it is important to promoting use of multimodal transport logistics terms in Incoterms, 2010 through as follows, a user's subjective factors : (1) to understand correlation of door to door multimodal transport and terms of Incoterms, 2010, (2) to promote use of multimodal transport logistics terms in Incoterms, 2010 in door to door multimodal transport, (3) to restrain customary use of FOB, CFR, CIF terms. And, the next, we have to promote use of multimodal transport logistics terms in Incoterms, 2010 through considering a trade transport logistics environment factors and a term content factors.

Distribution of the Scatter Ray on Chest X-ray Examinations (흉부 X선 촬영 시 산란선 분포 연구)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.255-260
    • /
    • 2012
  • This study aims to examine the generation of scatter rays by dividing it into the presence of the subject at the chest X-ray examination, the X-ray tube and detector in the X-ray room, the front of the patient window, the outside of the entrance door of the patient waiting room, opening of the entrance door, the outside of the radiological technologist's entrance door, and the opening of the radiological technologist's entrance door, etc. When there is a subject, as the subject is thicker, more scatter rays occur at each of the spots for measurement. And when the entrance door is closed at the measurement, fewer scatter rays are generated.