• Title/Summary/Keyword: 3D-SPACE

Search Result 3,600, Processing Time 0.033 seconds

Ultra-high Temperature EM Wave Absorption Behavior for Ceramic/Sendust-aluminosilicate Composite in X-band (X-Band 영역에서의 세라믹/샌더스트-알루미노실리케이트 복합재의 초고온 전자파 흡수 거동)

  • Choi, Kwang-Sik;Sim, Dongyoung;Choi, Wonwoo;Shin, Joon-Hyung;Nam, Young-Woo
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.201-215
    • /
    • 2022
  • This paper presents the development of thin and lightweight ultra-high temperature radar-absorbing ceramic composites composed of an aluminosilicate ceramic matrix-based geopolymer reinforced ceramic fiber and sendust magnetic nanoparticles in X-band frequency range (8.2~12.4 GHz). The dielectric properties with regard to complex permittivity of ceramic/sendust-aluminosilicate composites were proportional to the size of sendust magnetic nanoparticle with high magnetic characteristic properties as flake shape and its concentrations in the target frequency range. The characteristic microstructures, element composition, phase identification, and thermal stability were examined by SEM, EDS, VSM and TGA, respectively. The fabricated total thicknesses of the proposed single slab ultra-high temperature radar absorber correspond to 1.585 mm, respectively, exhibiting their excellent EM absorption performance. The behavior of ultra-high temperature EM wave absorption properties was verified to the developed free-space measurement system linked with high temperature furnace for X-band from 25℃ to 1,000℃.

Program Development and Field Application for the use of the Integration Map of Underground Spatial Information (지하공간통합지도 활용을 위한 프로그램 개발 및 현장 적용)

  • Kim, Sung Gil;Song, Seok Jin;Cho, Hae Yong;Heo, Hyun Min
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.483-490
    • /
    • 2021
  • Due to the recent increase in various problems from underground development in urbanized areas, accurate underground facility information management is highly needed. Therefore, in this study, in order to utilize the Integration Map of Underground Goespatial Information in real time on-site, the function of comparing the mutual location of the GPR (Ground Penetration Radar) sensing data and the Integration Map of Underground Goespatial Information, and function of analyze underground facilities, and function of converting surveying data into a shape file through position correction & attribute editing in a 3D space, and the function of submitting the shape file to the Integration Map of Underground Goespatial Information mobile center was defined and developed as a program. In addition, for the on-site application test of the development program, scenarios used at the underground facility real-time survey site and GPR exploration site were derived, and four sites in Seoul were tested to confirm that the use scenario worked properly. Through this, the on-site utilization of the program developed in this study could be confirmed, and it would contribute to the confirmation of the quality of Shape-file and the "update automation" of "Integration Map of Underground Goespatial Information". In addition, it is expected that the development program will be further applied to the Underground Facility Map's Accuracy Improvement Diffusion Project' promoted by the MOLIT (Ministry of Land, Infrastructure, and Transport).

Constrution and Application of Underground Facilities Survey System using the 3D Integration Map of Underground Geospatial Information (3차원 지하공간통합지도를 활용한 지하시설물 현장 측량 시스템 구축 및 적용)

  • SONG, Seok-Jin;CHO, Hae-Yong;HEO, Hyun-Min;KIM, Sung-Gil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.164-173
    • /
    • 2021
  • Recently, as underground space safety issues such as sink hole, ground subsidence and damage to old underground facilities have been increasing in urban areas, the precise management of underground facilities ins more required. Thus, this study developed a function to that, visualize on Integration Map of Underground Geospatial Information a real-time survey data of underground facilities acquired on site or underground facility survey data acquired through on-site survey after underground facility exploration and developed a function convert to surveying-results. In addition, using the on-site survey performance utilization function in connection with the Integration Map of Underground Geospatial Information developed through this study, the surveying -results obtained with the Total-station at the water pipeline burial construction site in Eunpyeong-gu, Seoul are visualized on the Integration Map of Underground Geospatial Information and On-site verification was performed by converting spatial-information performance files and transmitting the Integration Map of Underground Geospatial Information to the mobile center. Based on this, it was possible to verify the work procedure using the surveying-results in the area where the Integration Map of Underground Geospatial Information was built, and to review the direction of future improvement directions.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Synthesis of Fully Dehydrated Partially Cs+-exchanged Zeolite Y (FAU, Si/Al = 1.56), |Cs45Na30|[Si117Al75O384]-FAU and Its Single-crystal Structure

  • Seo, Sung-Man;Kim, Ghyung-Hwa;Lee, Seok-Hee;Bae, Jun-Seok;Lim, Woo-Taik
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.1285-1292
    • /
    • 2009
  • Large single crystals of zeolite, |$Na_{75}$|[$Si_{117}Al_{75}O_{384}$]-FAU (Na-Y, Si/Al = 1.56), were synthesized from gels with composition of 3.58Si$O_2$ : 2.08NaAl$O_2$ : 7.59NaOH : 455$H_2$O : 5.06TEA : 2.23TCl. One of these, a colorless single-crystal was ion exchanged by allowing aqueous 0.02 M CsOH to flow past the crystal at 293 K for 3 days, followed by dehydration at 673 K and 1 ${\times}\;10^{-6}$ Torr for 2 days. The crystal structure of fully dehydrated partially $Cs^+$-exchanged zeolite Y, |$Cs_{45}Na_{30}$|[$Si_{117}Al_{75}O_{384}$]-FAU per unit cell (a = 24.9080(10) $\AA$) was determined by single-crystal X-ray diffraction technique in the cubic space group Fd $\overline{3}$ m at 294(1) K. The structure was refined using all intensities to the final error indices (using only the 877 reflections with $F_o\;>\;4{\sigma}(F_o))\;R_1$ = 0.0966 (Based on F) and $R_2\;=\;0.2641\;(Based\;on\;F^2$). About forty-five $Cs^+$ ions per unit cell are found at six different crystallographic sites. The 2 $Cs^+$ ions occupied at site I, at the centers of double 6-ring (D6Rs, Cs-O = 2.774(10) $\AA$ and O-Cs-O = 88.9(3) and 91.1(3)$^o$). Two $Cs^+$ ions are found at site I’ in the sodalite cavity; the $Cs^+$ ions were recessed 2.05 $\AA$ into the sodalite cavity from their 3-oxygen plane (Cs-O = 3.05(3) $\AA$ and O-Cs-O = 77.4(13)$^o$). Site-II’ positions (opposite single 6-rings in the sodalite cage) are occupied by 7 $Cs^+$ ions, each of which extends 2.04 $\AA$ into the sodalite cage from its 3-oxygen plane (Cs-O = 3.067(11) $\AA$ and O-Cs-O = 80.1(3)$^o$). The 26 $Cs^+$ ions are nearly three-quarters filled at site II in the supercage, being recessed 2.34 $\AA$ into the supercage (Cs-O = 3.273(8) $\AA$ and O-Cs-O = 74.3(3)$^o$). The 4 $Cs^+$ ions are found at site III deep in the supercage (Cs-O = 3.321(19) and 3.08(3) $\AA$), and 4 $Cs^+$ ions at another site III’ (Cs-O = 2.87(4) and 3.38(4) $\AA$). About 30 $Na^+$ ions per unit cell are found at one crystallographic site; The $Na^+$ ions are located at site I’ in the sodalite cavity opposite double 6-rings (Na-O = 2.578(11) $\AA$ and O-Na-O = 97.8(4)$^o$).

Acute and Chronic Eosinophilic Pneumonia; Clinical and Laboratory Findings (급성 및 만성 호산구성 폐렴의 임상적 고찰)

  • Hyun, D.S.;Yeo, D.S.;Kim, J.W.;Lee, S.H.;Lee, S.Y.;Kim, S.C.;Seo, J.Y.;Song, S.H.;Kim, C.H.;Moon, H.S.;Song, J.S.;Park, S.H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.795-804
    • /
    • 1998
  • Background: Chronic eosinophilic pneumonia(CEP) is interstitial lung disease characterized by multiple infiltration on radiographic study, accumulation of eosinophils in the alveolar space and interstitium of the lung, chronic persistent symptoms and possible relapse. Acute eosinophilic pneumonia(AEP) is a recently described illness, characterized by rapid clinical course, acute respiratory insufficiency and no relapse. Method : To better characterize acute and chronic eosinophilic pneumonia, we studied the clinical and laboratory features of 16 patients(AEP : 7 patients, CEP : 9 patients), which were clinico-pathohistologically diagnosed and not to be associated with organic disorders producing peripheral blood eosinophilia. Results: The mean age was higher for patients with CEP than for patients with AEP ($55.4{\pm}15.1$ vs. $24.6{\pm}7.9$ years, p<0.05). High fever(above $38^{\circ}C$) was presented in all patients of AEP and in one patient(11%) of CEP. All patients of AEP and eight patients (89%) of CEP showed bilateral pulmonary infiltrates, and 6 patients(86%) of AEP and 2 patients(22%) of CEP showed pleural effusion in chest radiograph. The mean white blood cell count of AEP and CEP were $17,186/mm^3$ and $12,867/mm^3$, respectively. The mean peripheral blood eosinophil count of AEP and CEP were $939/mm^3$ and $2,104/mm^3$, respectively. The mean eosinophil fraction of BAL fluid of AEP and CEP were 32.4% (range: 18~47%) and 35.8% (range: 15.3~88.2%), respectively. The mean $PaO_2$ was lower for patients with AEP than for patients with CEP ($44.1{\pm}15.5$ vs. $62.7{\pm}6.9$mmHg, p<0.05). All patients of AEP and CEP were initially treated with antibiotics. All patients of CEP and one patients of AEP were finally required systemic steroid therapy. 6 patients of AEP were improved without steroid therapy. Relapse was observed in 3 patients(33%) of CEP. Conclusion : Compair with of chronic eosinophilic pneumonia, acute eosinophilic pneumonia was characterized by relatively young age, acute onset, high fever, severe hypoxemia, diffuse pulmonary infiltrates with pleural effusion, steroid therapy is effective but spontaneous improvement with conservative therapy was frequent.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Studies on Inheritance and Ecological Variation of the Culm Length and Its Related Characters in Short-Statured Rice Varieties (수도단간품종의 간장 및 관련형질의 유전과 생태적 변이에 관한 연구)

  • Sung-Ho Bea
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.13
    • /
    • pp.1-40
    • /
    • 1973
  • These studies were aimed at clarification of genetic and ecological variation in culm length, panicle length and plant height of the $\textrm{F}_2$ plants in some selected crosses made between semi-dwarf rice varieties and tall Japonica ones. One Indica semi-dwarf, Taichung Native 1, one Indica $\times$ Japonica hybrid, IE51 and one Japonica semi-dwarf, Tankanbaekmang were used as short-gene donors while two of medium maturity varieties, Jinheung and Kwanok and one late veriety, Palkweng were used as the corresponding counterpart of respective dwarf varieties in a series of crosses. Five different crosses, Kwanok $\times$ Tankanbaekmang, Palkweng $\times$ Tankanbaekmang, Jinheung $\times$ T(N)1, Kwanok $\times$ T(N)1 and Kwanok $\times$ IE51, were made among the above six varieties. The $\textrm{F}_2$ plants of these crosses together with the concerned parental varieties were grown under several different conditions including three levels of each nitrogen and planting space, three planting seasons and three locations in 1968, to investigate variation in length of culm and panicle, and plant height. On the other hand, the F$_3$ progenies which were derived from the shortest 10 percent of the plants of three $\textrm{F}_2$ populations, Kwanok $\times$ T(N)1, Jinheung $\times$ T(N) 1 and Kwanok $\times$ IE51 grown in the previous year, were compared each other on the basis of selection efficiency in culm length. The experimental results could be summarized as follows; 1. Genetic behavior A. It was revealed that Tankanbaekmang, one of Japonica dwarf has a simple recessive gene responsible for short culm expression, showing a typical segregation ratio of three tall to one short culm plants in $\textrm{F}_2$ generation of the crosses either with Kwanok or Palkweng. B. In the both combinations, segregation pattern of the panicle length was exactly same as that of culm length. It seems that the same gene controls both culm length and panicle length. C. No difference between segregation of culm length and plant height in the above crosses was observed. D. T(N)1, one of Indica semi-dwarf did not show such a simple genetic behavior as detected from the crosses with Tankanbaekmang in segregation of culm length but formed a continuous and normal distribution curve. Therefore, some nonallelic genic actions might be involved in expression of culm length of the counterpart varieties of T(N)1. In particular, a transgressive segregation appeared toward the direction of longer culm length in case of Jinheung $\times$ T(N)1. The genetic behavior of panicle length and plant height generally coincided with that of culm length in all the cases. E. IE51 demonstrated exactly the same genetic behavior as that of T(N)1 when this variety was crossed with Kwanok. It was clearly clarified that the simple recessive gene controlling dwarfism from T(N)1 was well incorporated into this variety. 2. Ecological variation A. In general, there was a decreasing tendency in culm length and plant height of rice plant as seeding delayed while it was not so noticeable in panicle length. The decreasing magnitude varied from variety to variety and from cross to cross. Genetic behavior of the culm length and related characters of these materials was not disturbed by the variation of seeding season, nitrogen level, planting space and experimental location. E. The elongation mode of the upper three internodes was very similar to the segregation mode of culm length, panicle length and plant height in $\textrm{F}_2$ populations of . all the crosses investigated in this study. Accordingly, this result confirmed that the roles of the upper three internodes are very important in manifesting plant stature in rice. C. The effect of nitrogen on culm length and the related other two characters seemed to be meager. However, it was true to show an increasing tendency of those characters as nitrogen level got increased from 4 kg to 12kg per l0a, with different magnitude depending upon variety or cross. D. Also, the effect of planting space on culm length, panicle length and plant height was relatively small in all the cases. Those characters varied again depending upon variety or cross. However, a general increasing tendency was detected in manifestation of those traits under denser planting space condition. E. All the parental varieties produced shorter culm, panicle and plant height when they were grown at the lower latitude locations. It might be attributed to the fact that their reproductive growth accelerated with increased temperature prevailing at the lower latitude locations such as Iri and Mi1yang. On the countrary, $\textrm{F}_2$ population reacted differently to the different locations from the parental varieties. All the $\textrm{F}_2$ plants produced the longest culm, panicle and plant at Milyang. 3. Selection efficiency A. The heritability of culm length in Kwanok $\times$ T(N)1, Kwanok $\times$ IE51 and Jinheung$\times$T(N)1 was 92 percent, 74 percent and 55 percent, respectively. B. The actual genetic advance for culm length obtained from the progeny lines of the selected plants(10 precent) from the $\textrm{F}_2$ generation, was comparable to the expected advance calculated from the original $\textrm{F}_2$ populations. As compared with the $\textrm{F}_2$ population, the $\textrm{F}_3$ plants of Kwanok $\times$ T(N)l shortened on the average by 20.8cm, those of Kwanok $\times$ IE51 did 8.7cm and those of Jinheung$\times$T(N)1 20.0cm, respectively. C. Panicle length of the populations was differently affected from one cross to another by the selection based upon culm length in $\textrm{F}_2$ Kwanok $\times$ T(N)1 did not show any noticeable shortening of its culm length due to the selection pressure. On the other hand, both Kwanok $\times$ IE51 and Jinheung $\times$ T(N)1 showed a considerable shortening of their panicles in case of selection for culm length. Based upon the above results, it could be concluded that the ecological variation in culm length, panicle length and plant height was relatively small and fallen within the range of genetic variation. Considering from the fact that the simple recessive gene governing short height of Tankanbaekmang always accompanied with some undesirable characters such as short panicle and extremely small grain, the short gene of T(N)1 seemed to be more useful as dwarf gene source since it did not carry short gene together with such undesirable traits.

  • PDF

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.

Efficacious Pleurodesis with OK-432 Plus Autoblood or OK-432 Against the Pneumothorax with Persistent Air Leak (지속성 기흉에서 OK-432와 자가혈액을 이용한 흉막 유착술의 효과)

  • Kim, Hyoung Soo;Choi, Goang Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.1
    • /
    • pp.72-75
    • /
    • 2006
  • Background : This report reviews our experience with persistent air leaks in the peumothorax that were not considered candidates for surgical treatment in order to evaluate the efficacy and risks of the OK-432 plus autoblood or OK-432 pleurodesis. Material & Methods : From March 2004 to July 2005, 8 consecutive patients who had an air leak in the pneumothorax over 5 days and had been treated with OK-432 plus autoblood or OK-432 pleurodesis. The patients were not considered candidates for surgical treatments because the chest CT findings revealed severe chronic lung disease with multiple bullae and/or bullous changes. A prolonged air leak with/without dead space was treated with either OK-432 plus autoblood or OK-432 pleurodesis. The efficacy and side effects of OK-432 pleurodesis were assessed by determining the duration of the air leak, the number of pleurodesis, the patients' symptoms, measurements of the white blood cell count and the c-reactive protein level. Results : All of eight patients were male and the mean age was $72.4{\pm}8.5$. The mean number of pleurodesis was $1.9{\pm}1.1$ and the mean duration of the air leak was $4.6{\pm}4.6days$ after pleurodesis. Side effects after pleurodesis were encountered in 7 patients, which included a chilling sensation in 7 cases, chest pain in 5 cases, headache in 3 cases, local heat sensation in 2 cases, and fever in 1 case. Leukocytosis was observed in 6 patients, and the mean of WBC count and CRP were $14500{\pm}2100$ and $21.9{\pm}11.4mg/dL$, respectively. Conclusion : Either OK-432 plus autoblood or OK-432 pleurodesis has acceptable side effects, and can be considered a treatment option for persistent air leaks in the pneumothorax that are not candidates for surgical treatment.