• Title/Summary/Keyword: 3D motion

Search Result 2,044, Processing Time 0.026 seconds

A Study on XR Handball Sports for Individuals with Developmental Disabilities

  • Byong-Kwon Lee;Sang-Hwa Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.31-38
    • /
    • 2024
  • This study proposes a novel approach to enhancing the social inclusion and participation of individuals with developmental disabilities. Utilizing cutting-edge virtual reality (VR) technology, we designed and developed a metaverse simulator that enables individuals with developmental disabilities to safely and conveniently experience indoor handicapped handball sports. This simulator provides an environment where individuals with disabilities can experience and practice handball matches. For the modeling and animation of handball players, we employed advanced modeling and motion capture technologies to accurately replicate the movements required in handball matches. Additionally, we ported various training programs, including basic drills, penalty throws, and target games, onto XR (Extended Reality) devices. Through this research, we have explored the development of immersive assistive tools that enable individuals with developmental disabilities to more easily participate in activities that may be challenging in real-life scenarios. This is anticipated to broaden the scope of social participation for individuals with developmental disabilities and enhance their overall quality of life.

A Control Method for designing Object Interactions in 3D Game (3차원 게임에서 객체들의 상호 작용을 디자인하기 위한 제어 기법)

  • 김기현;김상욱
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.3
    • /
    • pp.322-331
    • /
    • 2003
  • As the complexity of a 3D game is increased by various factors of the game scenario, it has a problem for controlling the interrelation of the game objects. Therefore, a game system has a necessity of the coordination of the responses of the game objects. Also, it is necessary to control the behaviors of animations of the game objects in terms of the game scenario. To produce realistic game simulations, a system has to include a structure for designing the interactions among the game objects. This paper presents a method that designs the dynamic control mechanism for the interaction of the game objects in the game scenario. For the method, we suggest a game agent system as a framework that is based on intelligent agents who can make decisions using specific rules. Game agent systems are used in order to manage environment data, to simulate the game objects, to control interactions among game objects, and to support visual authoring interface that ran define a various interrelations of the game objects. These techniques can process the autonomy level of the game objects and the associated collision avoidance method, etc. Also, it is possible to make the coherent decision-making ability of the game objects about a change of the scene. In this paper, the rule-based behavior control was designed to guide the simulation of the game objects. The rules are pre-defined by the user using visual interface for designing their interaction. The Agent State Decision Network, which is composed of the visual elements, is able to pass the information and infers the current state of the game objects. All of such methods can monitor and check a variation of motion state between game objects in real time. Finally, we present a validation of the control method together with a simple case-study example. In this paper, we design and implement the supervised classification systems for high resolution satellite images. The systems support various interfaces and statistical data of training samples so that we can select the most effective training data. In addition, the efficient extension of new classification algorithms and satellite image formats are applied easily through the modularized systems. The classifiers are considered the characteristics of spectral bands from the selected training data. They provide various supervised classification algorithms which include Parallelepiped, Minimum distance, Mahalanobis distance, Maximum likelihood and Fuzzy theory. We used IKONOS images for the input and verified the systems for the classification of high resolution satellite images.

Dosimetric Comparison of One Arc & Two Arc VMAT Plan for Prostate cancer patients (Prostate Cancer 환자에 대한 One Arc와 Two Arc VMAT Plan의 선량 측정 비교 분석)

  • Kim, Byoung Chan;Kim, Jong Deok;Kim, Hyo Jung;Park, Ho Chun;Baek, Jeong Ok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.107-116
    • /
    • 2018
  • Purpose : Intensity-modulated radiation therapy(IMRT) has been widely used for radiation therapy of Prostate Cancer because it can reduce radiation adverse effects on normal tissues and deliver more dose to the Prostate than 3D radiation therapy. Volumetric modulated arc therapy(VMAT) has been widely used due to recent advances in equipment and treatment techniques. VMAT can reduce treatment time by up to 55 % compared to IMRT, minimizing motion error during treatment. Materials and Methods : In this study, compared the MU and DVH values of 10 patients with prostate cancer by classifying them into 4 groups with 5 LN-Prostate groups and 5 Only-Prostate. And DQA measurements were performed using ArcCHECK and MapCHECK. Results : The results of Target and OAR dose distribution of Prostate patients are as follows. $D_{max}$ was in the range of 100~110 % in 4 groups, and more than 110 % of hot spot was not seen. Only-Prostate ($P_1$, $P_2$) without LN had a satisfactory dose distribution for the target dose, but slightly better for 2 arc plan($P_2$) than 1 arc plan($P_1$). The target dose $D_{98%}$ distribution in the LN-Prostate ($P_{L1}$, $P_{L2}$) group showed better 2 arc plan($P_{L2}$) than 1 arc plan($P_{L1}$), But in the case of 1 arc plan($P_{L1}$), the target dose $D_{98%}$ value was not enough. In OAR, the dose distribution of 1 Arc($P_1$) Plan and 2 Arc($P_2$) Plan in the Only-Prostate ($P_1$, $P_2$) Group satisfied the prescribed dose value. But, The dose distribution of 1 arc($P_1$) was slightly higher. In LN-Prostate OAR, 1 Arc($P_{L1}$) Plan showed higher dose than the prescribed dose. The Gamma evaluation pass rate of ArcCHECK and MapCHECK calculated from the DQA measurements was slightly higher than 99 % and the mean error range of the point dose measurements using the CC04 ion chamber was less than 1 %. Conclusion : In this study, Only-Prostate ($P_1$, $P_2$) group, the dose of 2 Arc plan was better. However, considering the treatment time and MU value, 1 Arc treatment method was more suitable. In the LN-Prostate ($P_{L1}$, $P_{L2}$) group, 2 Arc($P_{L2}$) treatment method showed better results and satisfied with Target $D_{98%}$ and OAR prescription dose.

  • PDF

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

A Kinematical Analysis of Mae-ukemi (forward breakfall) in Judo (유도전방낙법의 운동학적 특성 분석[I])

  • Kim, Eui-Hwan;Kim, Ji-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.131-142
    • /
    • 2002
  • The purpose of this study was to analyze kinematic variables of a Mae-ukemi (forward breakfall :MU) in Judo through 3-D image analysis with five Judoka with over 2 years' career (2nd dan, 3rd dan). The kinematic variables include posture, and distance variables; the mean values and the standard deviations for each variable were obtained to analyze kinematic variables of a MU in Judo. From the data analysis and discussion, the following conclusions were drawn : 1) Posture variables : The angles of wrists during right before Mae-ukemi (RBU) were extended from the just MU position(MUP) and flexed from in the right after MU(RAU), and there was a difference in the displacement between the angles of the right and left wrists. The angles of elbows were flexed in the ready position from in the RAU. The angles of ankles were flexed from the ready position to that down position, extended from the down position to that transition, and flexed from the transition positiont to that RAU. 2) Distance variables : The distance height between the mat and shoulders in the RBU(32.2cm) to in the MUP(18.3cm) and in the RAU(20.5cm). during that height between the mat and hips in the RBU(48.0cm) to in the MUP(23.4cm), and in the RAU(30.6cm).

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

  • Eun-Bin Bae;Won-Tak Cho;Do-Hyun Park;Su-Hyun Hwang;So-Hyoun Lee;Mi-Jung Yun;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.3
    • /
    • pp.155-170
    • /
    • 2023
  • PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 ㎛ but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 ㎛ in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

3-D Kinematic Analysis According to Open Stance Patterns During Forehand Stroke in Tennis (테니스 포핸드 스트로크 동안 오픈스탠스 조건에 따른 3차원 운동학적 분석)

  • Choi, Ji-Young;Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.161-173
    • /
    • 2005
  • Recently among several tennis techniques forehand stroke has been greatly changed in the aspect of spin, grip and stance. The most fundamental factor among the three factors is the stance which consists of open, square and closed stance. The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle according to open stance patterns during forehand stroke in tennis. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVlEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and racket head angle were defined 1. In three dimensional maximum linear velocity of racket head the X axis showed $11.41{\pm}5.27m/s$ at impact, not the Y axis(horizontal direction) and the z axis(vertical direction) maximum linear velocity of racket head did not show at impact but after impact this will resulted influence upon hitting ball It could be suggest that Y axis velocity of racket head influence on ball direction and z axis velocity influence on ball spin after impact. the stance distance between right foot and left foot was mean $74.2{\pm}11.2m$. 2. The three dimensional anatomical angular displacement of shoulder joint showed most important role in forehand stroke. and is followed by wrist joints, in addition the movement of elbow joints showed least to the stroke. The three dimensional anatomical angular displacement of racket increased flexion/abduction angle until the impact. after impact, The angular displacement of racket changed motion direction as extension/adduction. 3. The three dimensional anatomical angular displacement of trunk in flexion-extension showed extension all around the forehand stroke. The angular displacement of trunk in adduction-abduction showed abduction at the backswing top and adduction around impact. while there is no significant internal-external rotation 4. The three dimensional anatomical angular displacement of hip joint and knee joint increased extension angle after minimum of knee joint angle in the forehand stroke, The three dimensional anatomical angular displacement of ankle joint showed plantar flexion, internal rotation and eversion in forehand stroke. it could be suggest that the plantar pressure of open stance during forehand stroke would be distributed more largely to the fore foot. and lateral side.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Alternative Transform Based on the Correlation of the Residual Signal (잔여 신호의 상관성에 기반한 선택 변환)

  • Lim, Sung-Chang;Kim, Dae-Yeon;Lee, Yung-Lyul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.3
    • /
    • pp.80-92
    • /
    • 2008
  • Many predominant video coding tools in terms of coding efficiency were adopted in the latest video coding standard, H.264/AVC. Regardless of development of these predominant video coding tools such as the variable block-size motion estimation/compensation, intra prediction based on various directions, and so on, the discrete cosine transform has been continuously used starting from the early video coding standards. Generally, the correlation coefficient of the residual signal is usually less than 0.5 when this residual signal is actually encoded. In this interval of correlation coefficient, the discrete cosine transform does not show the optimal coding gain, and the discrete sine transform which is a sub-optimal transform when the correlation coefficient is in the interval from -0.5 to 0.5 can be used in conjunction with the discrete cosine transform in the video coding. In this paper, an alternative transform that alternatively uses the discrete sine transform and integer cosine transform in H.264/AVC by using rate-distortion optimization is proposed. The proposed method achieves a BD-PSNR gain of up to 0.71 dB compared to H.264/AVC JM 10.2 at relatively high bitrates.