• Title/Summary/Keyword: 3D body scan

Search Result 189, Processing Time 0.024 seconds

Surface Flattening criterion of Female's Upper Front Shell Using Grid Method (Grid method에 의한 성인 여성 3차원 형상의 상반신 앞판에 대한 평면전개 기준 연구)

  • Choi, Young-Lim;Nam, Yun-Ja;Choi, Kueng-Mi;Cui, Ming-Hai;Han, Sul-Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.12
    • /
    • pp.1825-1836
    • /
    • 2008
  • Many applications in computer graphics require complex and highly detailed models. However it is often desirable to use approximations in place of excessively detailed models in order to control the processing time. Thus, we aim to develop a notion of optimal matrix to simplify surface which can rapidly obtain the high quality 2D patterns flattening 3D surface as follows. Firstly, two 3D bodies are modeled based on existing Size Korea data. Secondly, each model is divided by shell and block for its pattern draft. Thirdly, each block is flattened by grid and bridge method. Finally, we selected the optimal matrix and demonstrated the efficiency and quality of the proposed method. This proposed approach accommodates surfaces with darts, which are commonly used in the clothing industry to reduce the deformation of surface forming and flattening. The resulting optimal matrix could be an initiation of standardization for pattern flattening. It is expected that this method could facilitate much better approximation in both efficiency and precision.

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Effects of four dim vs high intensity red color light regimens on growth performance and welfare of broilers

  • Senaratna, D.;Samarakone, T.S.;Gunawardena, W.W.D.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.1
    • /
    • pp.149-156
    • /
    • 2018
  • Objective: Broilers show clear preference towards red color light (RL). However setting of an optimum light intensity is difficult since dim intensities that favor growth reduce welfare. This experiment was conducted to test the most effective RL intensity regimen (Dim [5 lux; DI] vs high [320 lux; HI]) in combination applied at different growth stages that favors for both performance and welfare. Methods: Complete randomize design was adopted with 6 replicates. Treatments were; T1 = early DI (8-21 d)+latter HI (22-35 d); T2 = early DI (8-28 d)+latter HI (29-35 d), T3 = early HI (8-21 d)+latter DI (22-35 d), T4 = early HI (8-28 d)+latter DI (29-35 d) and T5 = control (white light; WT) (8-35 d) at medium intensity (20 lux). Body weight (BW), weight gain (WG), water/feed intake and ratio, feed conversion ratios (FCR) were assessed. Common behaviours (15) were recorded by scan sampling method. Lameness, foot pad dermatitis, breast blisters, hock burning damage were assessed as welfare parameters. Fear reactions were tested using Tonic Immobility Test. Ocular and carcass evaluations were done. Meat and tibiae were analyzed for fat and bone ash respectively. Results: On 35 d, the highest BW ($2,155.72{\pm}176g$), WG ($1,967.78{\pm}174g$) were recorded by T2 compared to WT ($BW_{WT}=1,878.22{\pm}155$, $WG_{WT}=1,691.83{\pm}160$). But, application of RL, either DI, or HI during early/latter stage had no significant effect on FCR. Under HI, birds showed much higher active behaviours. DI encourages eating. Though LI changed from DI to HI, same trend could be seen even under HI. The highest leg strength ($218.5{\pm}120s$) was recorded by T2. The lowest leg strength ($64.58{\pm}33s$) and the highest ocular weight ($2.48{\pm}1g$) were recorded by T1. Significantly (p<0.05) the highest skin weight ($162.17{\pm}6g$) but the lowest fat% in meat ($13.03%{\pm}5%$) was recorded by T2. Conclusion: Early exposure to DI-RL up to 28 days followed by exposure to HI-RL is the most favorable lighting regimen for optimizing production, better welfare of broilers and improving health benefits of meat.

THE EFFECT OF INDOMETHACIN ON PROSTAGLANDINS IN 4-NITROQUINOLINE-N-OXIDE (4-NQO) INDUCED PALATAL CARCINOMA OF ALBINO RATS (Indomethacin이 4-Nitroquinoline-N-Oxide(4-NQO) 유도 백서 구개암 발암과정에서 prostaglandins에 미치는 영향에 관한 연구)

  • Kim, Young-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.187-202
    • /
    • 1989
  • This study was undertaken to investigate the effect of indomethacin on prostaglandins in 4-Nitroquinoline-N-Oxide (4-NQO) induced palatal carcinoma of albino rats. 128 Sprague-Dawley strain albino rats-about 100g in body weight-were used in this study, divided into as belows; 1. Normal group (16-albino rats) with no treatment, 2. Control group (16-albino rats) treated with prophylene application onto palatal mucosa 3 times a week. 3. Experimental group I (48-albino rats) treated with 0.5% 4-NQO in prophylene application onto palatal mucosa 3 times a week. 4. Experimental group II (48-albino rats) treated with 0.5% 4-NQO in prophylene application with administered $20{\mu}g/ml$ of indomethacin in drinking water ad. lib. Four animals were sacrificed 7th, 13th, 19th, and 25th week respectively in normal and control group, and 7th, 9th, 11th, 13th, 15th, 17th, 19th, 21st, 23rd, 25th, 27th and 29th week respectively in experimental group I and II at each time. The palatal and lingual tissues were excised and kept frozen at $-70^{\circ}C$. Densitometer scan and Beta-counting counter were used for the thin layer chromatography of the arachidonic acid metabolites. The obtained results were as belows; 1. In normal and control group, there was little change of the arachidonic acid metabolites during experiment period, and the tissue homogenates included prostaglandin $D_2$, 6-keto-prostaglandin $F_{1{\alpha}}$, prostaglandin $E_2$, thromboxane $B_2$, prostaglandin $F_{2{\alpha}}$ in that order of relative abundances. 2. In experimental group I, prostaglandin $D_2$, and prostaglandin $E_2$ were increased, while 6-keto-prostaglandin $F_{1{\alpha}}$ and thromboxane $B_2$ were decreased in relative abundances of arachidonic acid metabolites. And there was little change in prostaglandin $F_{1{\alpha}}$ 3. In experimental group II, prostaglandin $D_2$, and prostaglandin $E_2$ were increased, while 6-keto-prostaglandin $F_{1{\alpha}}$ and thromboxane $B_2$ were decreased in relative abundances of arachidonic acid metabolites. And there was little change in prostaglandin $F_{2{\alpha}}$ also. 4. In the range of increase in prostaglandin $D_2$, and prostaglandin $E_2$, and that of decrease in 6-keto-prostaglandin $F_{1{\alpha}}$ and thromboxane $B_2$, in relative abundances, there was wider in experimental group I than in group II. 5. In the range of increase in prostaglandin $D_2$, and prostaglandin $E_2$, and that of decrease in 6-keto-prostaglandin $F_{1{\alpha}}$ and thromboxane $B_2$, in relative abundances, there was wider in palatal mucosa than in lingual mucosa in experimental group I and II.

  • PDF

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT (PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가)

  • Choong-Woon Lee;Yeon-Wook You;Jong-Woon Mun;Yun-Cheol Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.47-54
    • /
    • 2023
  • Purpose PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 mm with matrix size 128×128, slice thickness 3.75 mm, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in Wilcoxon signed rank test results (P value<0.001). Conclusion PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

  • PDF

Clinical Significance of Serum Thyroglobulin Levels in Patients with Thyroid Cancer (갑상선암에서 혈청 Thyroglobulin치의 임상적 의의)

  • Park, Sung-Ki;Lee, Myung-Sik;Lee, Myung-Chul;Cho, Bo-Youn;Kim, Byung-Kook;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.17 no.2
    • /
    • pp.41-47
    • /
    • 1983
  • To evaluate the significance of assay of serum thyroglobulin(Tg) in monitoring the course of the thyroid cancer or its response to treatment, serum thyroglobulin levels were measured in 41 patients with thyroid cancer who visited Seoul National University Hospital from August, 1981 to August, 1982. The results were as follows: 1) Serum Tg levels $1\sim3$ months after thyroidectomy was $31{\pm}23$ ng/ml$(mean{\pm}S.D.)$ in 14 patients without metastasis, $66{\pm}41$ ng/ml in 21 patients with regional metastasis and $176{\pm}59$ ng/ml in 6 patients with distant metastasis and there were significant differences among three groups(p<0.01). 2) Serum Tg levels in 13 patients with metastasis before and after $^{131}I$ treatment were $134{\pm}62ng/ml$ and $67{\pm}52ng/ml$ respectively. 3) In the follow-up measurement of serum Tg levels every 3 months for about 1 year, almost all serum Tg levels were below 60 ng/ml in 12 patients without distant metastasis and serum Tg levels were elevated above 60 ng/ml in 5 of 6 patients with distant metastasis. 4) In 6 patients with distant metastasis, serum Tg levels were elevated in 5 patients and $^{131}I$ whole body scan showed definite metastatic evidence in 3 patients and suspicious evidence in 1 patient. From above results, we concluded that serum Tg level is very useful as an indicator of recurrence or metastasis in patients with thyroid cancer after operation.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Study on the Application of Artificial Intelligence Model for CT Quality Control (CT 정도관리를 위한 인공지능 모델 적용에 관한 연구)

  • Ho Seong Hwang;Dong Hyun Kim;Ho Chul Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.182-189
    • /
    • 2023
  • CT is a medical device that acquires medical images based on Attenuation coefficient of human organs related to X-rays. In addition, using this theory, it can acquire sagittal and coronal planes and 3D images of the human body. Then, CT is essential device for universal diagnostic test. But Exposure of CT scan is so high that it is regulated and managed with special medical equipment. As the special medical equipment, CT must implement quality control. In detail of quality control, Spatial resolution of existing phantom imaging tests, Contrast resolution and clinical image evaluation are qualitative tests. These tests are not objective, so the reliability of the CT undermine trust. Therefore, by applying an artificial intelligence classification model, we wanted to confirm the possibility of quantitative evaluation of the qualitative evaluation part of the phantom test. We used intelligence classification models (VGG19, DenseNet201, EfficientNet B2, inception_resnet_v2, ResNet50V2, and Xception). And the fine-tuning process used for learning was additionally performed. As a result, in all classification models, the accuracy of spatial resolution was 0.9562 or higher, the precision was 0.9535, the recall was 1, the loss value was 0.1774, and the learning time was from a maximum of 14 minutes to a minimum of 8 minutes and 10 seconds. Through the experimental results, it was concluded that the artificial intelligence model can be applied to CT implements quality control in spatial resolution and contrast resolution.

Designing of the Statistical Models for Imprinting Patterns of Quantitative Traits Loci (QTL) in Swine (돼지에 있어서 양적 형질 유전자좌(QTL) 발현 특성 분석을 위한 통계적 검정 모형 설정)

  • Yoon D. H.;Kong H. S.;Cho Y. M.;Lee J. W.;Choi I. S.;Lee H. K.;Jeon G. J.;Oh S. J.;Cheong I. C.
    • Journal of Embryo Transfer
    • /
    • v.19 no.3
    • /
    • pp.291-299
    • /
    • 2004
  • Characterization of quantitative trait loci (QTL) was investigated in the experimental cross population between Berkshire and Yorkshire breed. A total of 512 F$_2$ offspring from 65 matting of F$_1$ parents were phenotyped the carcass traits included average daily gain (ADG), average backfat thickness (ABF), tenth rip backfat thickness (TRF), loin eye area (LEA), and last rip backfat thickness (LRF). All animals were genotyped for 125 markers across the genome. Marker linkage maps were derived and used in QTL analysis based on line cross least squares regression interval mapping. A decision tree to identify QTL with imprinting effects was developed based on tests against the Mendelian mode of QTL expression. To set the evidence of QTL presence, empirical significance thresholds were derived at chromosome-wise and genome-wise levels using specialized permutation strategies. Significance thresholds derived by the permutation test were validated in the data set based on simulation of a pedigree and data structure similar to the Berkshire-Yorkshire population. Genome scan revealed significant evidences for 13 imprinted QTLs affecting growth and body compositions of which nine were identified to be QTL with paternally expressed inheritance mode. Four of QTLs in the loin eye area (LEA), and tenth rip backfat thickness (TRF), a maternally expressed QTL were found on chromosome 10 and 12. These results support the useful statistical models to analyse the imprinting far the QTLs related carcass trait.