• Title/Summary/Keyword: 3D beam

Search Result 1,687, Processing Time 0.031 seconds

Rectal Complication Following Radical Radiotherapy in Carcinoma of the Uterine Cervix (자궁경부암에서 근치적 방사선치료 후의 직장 합병증)

  • Kim Won-Dong;Park Woo-Yoon
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.44-50
    • /
    • 2006
  • Puroose: This study evaluated the late rectal complications in cervix cancer patients following treatment with external beam radiotherapy (EBRT) and high dose rate intracavitary radiation (HDR ICR). The factors affecting the risk of developing late rectal complications and its incidence were analyzed and discussed. Materials and Methods: The records of 105 patients with cervix cancer who were treated with radical radiotherapy using HDR ICR between July, 1995 and December, 2001 were retrospectively reviewed. The median dose of EBRT was 50.4Gy $(41.4{\sim}56.4 Gy)$ with a daily fraction size of 1.8Gy. A total of $5{\sim}7$ (median: 6) fractions of HDR ICR were given twice weekly with a fraction size of $4{\sim}5 Gy$ (median: 4Gy) to A point using an Ir (Iridium)-192 source. The median dose of ICR was 24 Gy $(20{\sim}35 Gy)$. During HDR ICR, the rectal dose was measured in vivo by a semiconductor dosimeter. The median follow-up period was 32 months, ranging from 5 to 84 months. Results: Of the 105 patients, 12 patients (11%) developed late rectal complications: 7 patients with grade 1 or 2, 4 patients with grade 3 and 1 patient with grade 4. Rectal bleeding was the most frequent chief complaint. The complications usually began to occur $5{\sim}32$ (median: 12) months after the completion of radiotherapy. Multivariate analysis revealed that the measured cumulative rectal BED over 115 Gy3 (Deq over 69 Gy) and the depth (D) of a 5 Gy isodose volume more than 50 mm were the independent predictors for late rectal complications. Conclusion: With evaluating the cumulative rectal BED and the depth of a 5 Gy isodose volume as predictors, we can individualize treatment planning to reduce the probability of late rectal complications.

General Activity and Stress Response of Rats Following Removal of the Mamillary Bodies (유두체를 떼어버린 흰쥐의 일반활동 및 스트레스에 대한 반응)

  • Kim, Chul;Choi, Hyun;Kim, Chung-Chin;Kim, Jong-Kyu;Kim, Myung-Suk
    • The Korean Journal of Physiology
    • /
    • v.2 no.1
    • /
    • pp.79-88
    • /
    • 1968
  • For the purpose of assessing the influence of the mamillary bodies on the general activity and stress response, mamillary body·damaged rats(mamillary body group), operated control rats, and normal control animals were prepared and 2 experiments were carried out. The mamillary bodies. were damaged electrolytically by passing 0.3 ma d.c. current through stereotaxically implanted electrodes. The operated control group received the same treatment except passage of current. In the 1st experiment, each subject belonging to the mamillary body group .(9 rats) or the operated control group (13 animals) was put individually into an activity cage across which an infrared beam traversed. The number of beam interruptions by the movement of the subject in the cage was. recorded hourly for 48 hours and was regarded as an index of general activity. In the 2nd experiment, each of the mamillary body group (52 animals), the operated control group (45 rats), and the normal control group (37 animals) was further divided into 4 subgroups and the adrenal ascorbic acid content of one of the 4 subgroups was measured before, another subgroup immediately after, a third subgroup 2 hours after, and the remaining subgroup 4 hours after termination of a cold stress ($-10^{\circ}C$ for 1 hour). Following results were obtained: 1. Though the total activities in 48 hours of the mamillary body group and the operated control group were not significantly different, the activities of the malnillary body group for a few hours. at the beginning of the measurement and also in the evenings of both the 1st and the 2nd experimental days were significantly greater than those of the operated control group. 2. Judged by the significant reduction in adrenal ascorbic acid content, the stress response of the mamillary body group was as marked as that of the operated control or the normal control group-immediately after termination of cold exposure. Recovery from the stress was accelerated significantly in the mamillary body group and insignificantly in the operated control group compared with that of the normal control group, the intergroup difference of the former two groups being insignificant. It was inferred from the above results that the mamillary bodies may exert an inconspicuous inhibitory influence upon the central mechanism of general activity, and that the mamillaryies bodies may not be the main seat of the stress mechanism, although more works are desirable to confirm the results.

  • PDF

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Analysis of the Causes of Subfrontal Recurrence in Medulloblastoma and Its Salvage Treatment (수모세포종의 방사선치료 후 전두엽하방 재발된 환자에서 원인 분석 및 구제 치료)

  • Cho Jae Ho;Koom Woong Sub;Lee Chang Geol;Kim Kyoung Ju;Shim Su Jung;Bak Jino;Jeong Kyoungkeun;Kim Tae_Gon;Kim Dong Seok;Choi oong-Uhn;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.165-176
    • /
    • 2004
  • Purpose: Firstly, to analyze facto in terms of radiation treatment that might potentially cause subfrontal relapse in two patients who had been treated by craniospinal irradiation (CSI) for medulloblastoma, Secondly, to explore an effective salvage treatment for these relapses. Materials and Methods: Two patients who had high-risk disease (T3bMl, T3bM3) were treated with combined chemoradiotherapy CT-simulation based radiation-treatment planning (RTP) was peformed. One patient who experienced relapse at 16 months after CSI was treated with salvage surgery followed by a 30.6 Gy IMRT (intensity modulated radiotherapy). The other patient whose tumor relapsed at 12 months after CSI was treated by surgery alone for the recurrence. To investigate factors that might potentially cause subfrontal relapse, we evaluated thoroughly the charts and treatment planning process including portal films, and tried to find out a method to give help for placing blocks appropriately between subfrotal-cribrifrom plate region and both eyes. To salvage subfrontal relapse in a patient, re-irradiation was planned after subtotal tumor removal. We have decided to treat this patient with IMRT because of the proximity of critical normal tissues and large burden of re-irradiation. With seven beam directions, the prescribed mean dose to PTV was 30.6 Gy (1.8 Gy fraction) and the doses to the optic nerves and eyes were limited to 25 Gy and 10 Gy, respectively. Results: Review of radiotherapy Portals clearly indicated that the subfrontal-cribriform plate region was excluded from the therapy beam by eye blocks in both cases, resulting in cold spot within the target volume, When the whole brain was rendered in 3-D after organ drawing in each slice, it was easier to judge appropriateness of the blocks in port film. IMRT planning showed excellent dose distributions (Mean doses to PTV, right and left optic nerves, right and left eyes: 31.1 Gy, 14.7 Gy, 13.9 Gy, 6.9 Gy, and 5.5 Gy, respectively. Maximum dose to PTV: 36 Gy). The patient who received IMRT is still alive with no evidence of recurrence and any neurologic complications for 1 year. Conclusion: To prevent recurrence of medulloblastoma in subfrontal-cribriform plate region, we need to pay close attention to the placement of eye blocks during the treatment. Once subfrontal recurrence has happened, IMRT may be a good choice for re-irradiation as a salvage treatment to maximize the differences of dose distributions between the normal tissues and target volume.

Diagnosis of Real Condition and Distribution of Protected Trees in Changwon-si, Korea (창원시 보호수의 분포현황과 실태진단)

  • You, Ju-Han;Park, Kyung-Hun;Lee, Young-Han
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.1
    • /
    • pp.59-70
    • /
    • 2011
  • The purpose of this study is to present raw data to systematically and rationally manage the protected trees located in Changwon-si, Korea. This study investigated about the present condition and the information of location, individual, management, health and soil. The results are as follows. The protected trees were located in 26 spots, and species of trees were 9 taxa; Zelkova serrata, Celtis sinensis, Aphananthe aspera, Ginkgo biloba, Carpinus tschonoskii, Pinus densiflora for. multicaulis, Quercus variabilis, Pinus densiflora and Salix glandulosa. In protected tree types, shade trees were the most, and the majority of theirs were 200 years or more in age. The range of altitude was 14~173m, and the number of trees located in flat fields was the most. For location types, village and field and mountain were presented in the order and, in land use, land for building was the most. The range of height was 8.0~30.0m, 0.6~5.1m in crown height, 240~700cm in diameter of breast and 210~800cm in diameter of root. In case of crown area, Zelkova serrata of No.5 was most large. The status boards were mostly installed except No.23 and No.26. The sites with fence were 9 spots, and the site with stonework were 14 spots. The sites with the support beam were 5 spots, and most sites were not covered up with soil. The materials of bottom were soil, gravel and vegetation in the order. The range of withering branch rate was 0~40%, and peeled bark rate was 0~60%. The sites made holes were 23 spots, and the hole size of Aphananthe aspera of No.12 was the largest. The sites disturbed by human trampling were 7 spots, the sites by disease and insects of 2 spots, the sites by injury of 23 spots and the sites by exposed roots of 13 spots. In the results of soil analysis, there showed that acidity was pH 4.5~8.0, organic matter content of 3.5~69.8g/kg, electrical conductivity(EC) of 0.11~2.87dS/m, available $P_2O_5$ of 3.0~490.6mg/kg, exchangeable K of 0.10~1.05cmol+/kg, exchangeable Ca of 1.41~16.45cmol+/kg, exchangeable Mg of 0.37~1.96cmol+/kg, exchangeable Na of 0.25~2.41cmol+/kg and cation exchange capacity(C.E.C) of 8.35~26.55cmol+/kg.

Effects of thickness of GIZO active layer on device performance in oxide thin-film-transistors

  • Woo, C.H.;Jang, G.J.;Kim, Y.H.;Kong, B.H.;Cho, H.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.137-137
    • /
    • 2009
  • Thin-film transistors (TFTs) that can be prepared at low temperatures have attracted much attention due to the great potential for flexible electronics. One of the mainstreams in this field is the use of organic semiconductors such as pentacene. But device performance of the organic TFTs is still limited by low field effect mobility or rapidly degraded after exposing to air in many cases. Another approach is amorphous oxide semiconductors. Amorphous oxide semiconductors (AOSs) have exactly attracted considerable attention because AOSs were fabricated at room temperature and used lots of application such as flexible display, electronic paper, large solar cells. Among the various AOSs, a-IGZO was considerable material because it has high mobility and uniform surface and good transparent. The high mobility is attributed to the result of the overlap of spherical s-orbital of the heavy pest-transition metal cations. This study is demonstrated the effect of thickness channel layer from 30nm to 200nm. when the thickness was increased, turn on voltage and subthreshold swing were decreased. a-IGZO TFTs have used a shadow mask to deposit channel and source/drain(S/D). a-IGZO were deposited on SiO2 wafer by rf magnetron sputtering. using power is 150W, working pressure is 3m Torr, and an O2/Ar(2/28 SCCM) atmosphere at room temperature. The electrodes were formed with Electron-beam evaporated Ti(30nm) and Au(70nm) structure. Finally, Al(150nm) as a gate metal was evaporated. TFT devices were heat treated in a furnace at $250^{\circ}C$ in nitrogen atmosphere for an hour. The electrical properties of the TFTs were measured using a probe-station to measure I-V characteristic. TFT whose thickness was 150nm exhibits a good subthreshold swing(S) of 0.72 V/decade and high on-off ratio of 1E+08. Field effect mobility, saturation effect mobility, and threshold voltage were evaluated 7.2, 5.8, 8V respectively.

  • PDF

Anomalous Effect of Hydrogenation on the Optical Characterization $In_{0.5}Ga_{0.5}As$ Quantum Dot Infrared Photodetectors (MBE로 성장된 $In_{0.5}Ga_{0.5}As/GaAs$ 양자점 원적외선 수광소자의 수소화 처리가 광학적 특성에 미치는 특이영향)

  • Lim J.Y.;Song J.D.;Choi W.J.;Cho W.J.;Lee J.I.;Yang H.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.223-230
    • /
    • 2006
  • We have investigated the characteristics of hydrogen (H) plasma treated quantum dot infrared photodetectors (QDIPs). The structure used in this study consists of 3 stacked, self assembled $In_{0.5}Ga_{0.5}As/GaAs$ QD layer separated by GaAs barrier layers that were grown by molecular beam epitaxy. Optical characteristics of QDIPs, such as photoluminescence (PL) spectra and photocurrent spectra, have been studied and compared with each other for the as grown and H plasma treated QDIPs. H plasma treatment, resulted in the splitting of PL peak, which can be attributed to the redistribution of the size of QDs. The activation energies estimated from the temperature dependence of integrated PL intensity for as grown and H plasma treated QDIPs are found to be in good agreement with those determined from corresponding peaks of photocurrent spectra. It is also noted that photocurrent is detected up to 130 K for the H plasma treated QDIP, suggesting the future possibility for the development of infrared photodetectors with high temperature operation.

Patterns of Failure According to Radiation Treatment Technique in the Parotid Gland Cancer (이하선암의 술후 방사선치료시 방사선치료 방법에 따른 치료 실패 양상 분석)

  • Lee Sang-Wook;Lee Chang-Geol;Keum Ki-Chang;Park Cheong-Soo;Choi Eun-Chang;Shin Hyun-Soo;Chu Sung-Sil;Lee Suk;Cho Kwang-Hwan;Suh Chang-Ok;Kim Gwi-Eon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.167-171
    • /
    • 2000
  • Objectives: To compare the outcomes of treatment with a focus on the effectiveness of the two primary techniques of radiation used for treating parotid gland malignancies. Materials and Methods: A retrospective analysis of 70 patients with parotid gland cancer treated between 1981-1997. Radiation was delivered through an ipsilateral field of high energy electron and photon in 37 patients(52.9%). Two wedge paired photon was used to treat in 33 patients(47.1%). The median dose was 60 Gy, typically delivered at 1.8-2.0Gy per fraction. The median follow-up times for surviving patients was 60 months. Results: The overall and disease free 5 year survival rates were 71.6% and 69.5%, respectively. Wedge paired photon and photon-electron treatment disease tree 5 year survival rates were 61.1% and 80.5%, respectively. Overall local failure rate was 18.6%. Local failure rate of wedge paired photon technique was higher than that of mixed beam technique. Late complication rate was 37.1%, but most of them were mild grade. Conclusion: Techniques of radiation were associated with local control. The technique of using an ipsilateral field encompassing the parotid bed and treated with high energy electrons often mixed photons was effective with minimal severe late toxicity. To irradiate deep sited tumors, we consider 3-D conformal treatment plan for well encompassing the target volume.

  • PDF

Tele-metering

  • Hearte, L.O.
    • 전기의세계
    • /
    • v.2
    • /
    • pp.6-14
    • /
    • 1949
  • Telemetering may be described as the art of metering at a considerable distance those quantities which are ordinarily encountered in industry, and in the generation of electric power. It is in the production of electric power that telemetering is particularly important, for it permits the system operator, or load dispatcher, to have before him at all times a continuous graphic record of the power output of each individual generating station together with an automatically made continuous graphic record of the total system output. There desired individual graphic records may be obtained showing power flow in or out, on important tie lines, etc. Such arrangements have the very great advantage that loads may be assigned to each generating station so that the best over-all system economy may be obtained and the system operator at all times may see with his own eyes that loads scheduled are actually held at the various stations. Moreover, with such equipment, in the event of system or station trouble the load dispatcher can see exactly what station, or stations, are affected and to what extent, without having to get in touch with anyone by telephone. Decisions can, therefore, be quickly reached for rescheduling the load. One of the most accurate and reliable telemetering systems is based on the use of potentiometric circuits, the fundamentals of which are discussed below. A member of such telemetering systems have been installed for the Boston Edicon Co., Boston, Massachusetts, the Consolidated Edison Co. of New York City. The Public Service Gas & Electric Co. of Newark, new Jersey. The Philadelphia Electric Co. for Philadelphia, Pennsylvania, and the Pennsylvania Railroad Co. for their electrified zone between New York and Washington a distance of over 200 miles. The scale of the totalizing recorder for the New York area is 3,000,00 KW. That of the totalizing recorder for the Philadelphia area is 2,000,000 KW. The initial installation using this type of equipment described was placed in service for the Philadelphia Electric Co. in 1923. All of the original recording instruments are still in service, later instruments have been added to take care of additions to the power system and naturally these later recorders have incorporated in those refinements in design made since the earlier ones were manufactured. Many other installations of similar equipment have been made in the United States in various locations such as at St. Louis, on the West Coast, at Baltimore and in Washington, D.C. While the use of these basic potentiometric circuits involves the use of continuous metallic circuits of good insulation resistance and free of grounds, nevertheless, intermediate transmission links, involving and impulse method suitable for use on telephone Morse carrier channels is available. This same method may be employed on power line carrier systems and is also suitable for use on beam type microwave transmission. Many impulse type units are also used as a link in these potantiometric methods. For the sake of brevity a description is given only of these basic potentiometric circuits. If there is sufficient interest in Korea, a further paper can be given covering those impulse circuits also.

  • PDF

Pushover Analysis of an Unbraced 5-Story Steel Framed Structure for Arrangement of Semi-Rigid Connection (반강접 접합부 배치에 따른 비가새 5층 철골골조구조물의 비탄성 정적해석)

  • Kang, Suk-Bong;Kim, Sin-Ae
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.4
    • /
    • pp.325-334
    • /
    • 2010
  • In this study, an unbraced five-story steel-framed structure was designed in accordance with KBC2005 to understand the features of structural behavior for the arrangement of semi-rigid connections. A pushover analysis of the structural models was performed, wherein all the connections were idealized as fully rigid and semi-rigid. Additionally, horizontal and vertical arrangements of the semi-rigid connection were adopted for the models. A fiber model was utilized for the moment-curvature relationship of the steel beam and the column, and a three-parameter power model was adopted for the moment-rotation angle of the semi-rigid connection. The top displacement, base-shear force, required ductility for the connection, sequence of the plastic hinge, and design factors such as the overstrength factor, ductility factor, and response modification coefficient were investigated using the pushover analysis of a 2D structure subjected to the equivalent static lateral force of KBC2005. The partial arrangement of the semi-rigid connection was found to have secured higher strength and lateral stiffness than that of the A-Semi frame, and greater ductility than the A-Rigid frame. The TSD connection was found suitable for use for economy and safety in the sample structure.