• Title/Summary/Keyword: 3D Master Model

Search Result 69, Processing Time 0.023 seconds

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

Development of Investment Casting Technique using R/P Master Model (R/P 마스터모델을 활용한 정밀주조 공정기술의 개발)

  • Im, Yong-Gwan;Chung, Sung-Il;Jeong, Hae-Do
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.52-57
    • /
    • 1999
  • Funtional metal prototypes are often required in numerous industrial applications. These components are typically needed in the early stage of a project to determine form, fit and function. Recent R/P(Rapid Prototyping) part are made of soft materials such as plastics, wax, paper, these master models cannot be employed durable test in real harsh working environment. Parts by direct metal rapid tooling method, such as laser sintering, by now are hard to get net shape, pores of the green parts of powder casting method must be infiltrated to get proper strength as tool, and new type of 3D direct tooling system combining fabrication welding arc and cutting process is reported by song etc. But a system which can build directly 3D parts of high performance functional material as metal part would need long period of system development, massive investment and other serious obstacles, such as patent. In this paper, through the rapid tooling process as silicon rubber molding using R/P master model, and fabricate wax pattern in that silicon rubber mold using vacuum casting method, then we tranlsated the wax patterns to numerous metal prototypes by new investment casting process combined conventional investment casting with rapid pototyping & rapid tooling process. with this wax-injection-mold-free investment casting, we developed new investment casting process of fabricating numerous functional metal prototypes from one master model, combined 3-D CAD, R/P and conventional investment casting and tried to expect net shape measuring total dimension shrinkage from R/P part to metal part.

  • PDF

DEVELOPMENT OF BUILDING INFORMATION MODEL FOR RESOURCES OPTIMIZATION IN CONSTRUCTION PROJECT

  • Gopal M. Naik;Rokhsareh Badamahgan
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.634-639
    • /
    • 2013
  • The aim of the study is to develop the 3D visualization of Building Information Model and integrated 4D model for optimization of resources in the construction project. This study discuss the process of methodology and creation of 4D model of the project and simulate it to monitor the workflow at the site. Different stages of the construction process and activities are generated by using Revit and MS Project. MS project has been used for creation of the schedules and these are linked with the Revit for 3D modeling. The time used as the fourth dimension and 4D model created by using Navisworks Time liner software. Narges shopping center is presented as a case study to realize the actual uses and benefits of Building Information Model (BIM). Narges shopping mall is located in Tehran, Iran. As a part of Hekmat master plan, Narges shopping center is an 11 stores building with a total area of 30000 Sq.m. This shopping and entertainment center is comprised of 150 retails and two multi-use public halls with a capacity of 400 persons each and underground parking with total 400 parking space. The main purpose of architecture was to create an urban public center along with its revolving, spiral like form and an ever changing continuous façade by means of different colors, materials, which is in harmony with the other building of the master plan. The approximate cost of the project is $17 million and duration of the project schedule is 30 months. The developed Building Information Model enabled us to identify the potential collisions or clashes between various structural and architectural systems. 4D model has been used for limiting the interaction between subcontractors installing the different systems so rework could be avoided and productivity maximized. It is also observed that the utility of BIM for construction stimulation and clash detection is the best suitable method. Clash detection before the implementation of work is highly recommended to avoid rework.

  • PDF

EFFECT OF IMPRESSION TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS (인상채득방법이 임플란트 주모형의 정확성에 미치는 영향)

  • Kim Young-Oh;Yang Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.238-247
    • /
    • 2004
  • Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on fxiture level (Group FIX-D), 2) indirect method on fixture level(Group FIX-I), 3) modified indirect method on fixture level(Group FIX-M), 4) direct method on abutment level(Group AB-D) and 5) indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^{(R)}$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results : The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2. In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error. Conclusion: An impression method have more effect on accuracy of master model than an impression level. A modified indirect method showed smallest vertical and horizontal error.

Evaluation of the marginal and internal fit of a single crown fabricated based on a three-dimensional printed model

  • Jang, Yeon;Sim, Ji-Young;Park, Jong-Kyoung;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2018
  • PURPOSE. To evaluate the fit of a crown produced based on a 3D printed model and to investigate its clinical applicability. MATERIALS AND METHODS. A master die was fabricated with epoxy. Stone dies were fabricated from conventional impressions (Conventional stone die group: CS, n=10). Digital virtual dies were fabricated by making digital impressions (Digital Virtual die group: VD, n=10). 3D data obtained from the digital impression was used to fabricate 3D printed models (DLP die group: DD, n=10, PolyJet die group: PD, n=10). A total of 40 crowns were fabricated with a milling machine, based on CS, VD, DD and PD. The inner surface of all crowns was superimposed with the master die files by the "Best-fit alignment" method using the analysis software. One-way and 2-way ANOVA were performed to identify significant differences among the groups and areas and their interactive effects (${\alpha}=.05$). Tukey's HSD was used for post-hoc analysis. RESULTS. One-way ANOVA results revealed a significantly higher RMS value in the 3D printed models (DD and PD) than in the CS and DV. The RMS values of PD were the largest among the four groups. Statistically significant differences among groups (P<.001) and between areas (P<.001) were further revealed by 2-way ANOVA. CONCLUSION. Although the fit of crowns fabricated based on the 3D printed models (DD and PD) was inferior to that of crowns prepared with CS and DV, the values of all four groups were within the clinically acceptable range (<$120{\mu}m$).

THE EFFECT OF IMMERSION DISINFECTION ON THE DIMENSIONAL STABILITY OF RUBBER IMPRESSION MATERIALS (침적 소독이 고무 인상재의 크기 안정성에 미치는 영향)

  • Min, Geun-Nam;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.496-505
    • /
    • 1998
  • The purpose of this study was to evalute the effect of immersion disinfection on the dimensional stability of rubber impression materials. The metallic master model was made in order to simulate the intraoral arch form. Impressions were made from four impression materials (Exaflex, Extrude, Reprosil, Impregum-F) and immersed in three disinfectant solutions (Wydex, Vi-Pon, Potadine). Casts from the impressions were measured according to the interpreparation distance. The A-B and The B-D abutment distance were compared with the control group and disinfected groups. The results were as follows; 1. The measurements of the stone cast increased relative to the master model and there was a significant difference (P<0.05). 2. The relative dimensional change of the stone cast as compared with master model ranged from 0.10% to 0.56% in the A-B distance and ranged from 0.04% to 0.27% in the B-D distance. 3. The dimensional change of the disinfected groups as compared with the control group was significantly different in the three impression materials except for Impregum-F (P<0.05). 4. The relative dimensional change of the disinfected groups compared with the control group ranged from 0% to 0.20% in the A-B distance and ranged from -0.09% to 0.11% in the B-D distance. These results suggest that immersion disinfection of rubber impression materials by chemical disinfectants causes very small dimensional change and the change is clinically acceptable for prothesis fabrication

  • PDF

Comparison of the accuracy of implant digital impression coping (임플란트 디지털 인상용 코핑의 정확성 비교)

  • Ahn, Gyo-Zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.29-40
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the accuracy of impression taking method using the encoded healing abutment, scan body and pick-up impression coping with different implant angulations. Materials and Methods: Master model was fabricated by 3D printer and three implants were placed into the model with 0°, 10° and 20° mesial angulation. The abutments were secured to each implants and master model was scanned to make a reference model. Group P model was fabricated using pick-up impression copings and model was scanned after securing the abutments. Encoded healing abutment (Group E) and scan body (Group S) were secured on the master model and digital impression was taken using intraoral scanner 15 times each. Each STL files of test groups were superimposed with reference model using best fit alignment and root mean square (RMS) value was analyzed. Results: The RMS values were lowest in Group P, followed by Group S and Group E. Group P showed significant difference with Group S and E (P < 0.05) while there was no significant difference between Group S and E. Correlation between implant angulation and RMS value was significant in Group E (P < 0.05). Conclusion: The pick-up impression coping method showed higher accuracy and there was no significant difference in accuracy between the healing abutment and the scan body. The clinical use of the encoded healing abutment is possible, but it should be used with caution in the case of angulated implant.

ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY (가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구)

  • Eom Sang-Ho;Oh Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.