• 제목/요약/키워드: 3D Coordinates

검색결과 617건 처리시간 0.032초

적응형 윈도우를 이용한 스테레오 내시경에서의 깊이추출 연구 (Depth Extraction from Stereo Endoscope Using Adaptive Window)

  • 황도식;김정훈;안종식;이성재;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.265-266
    • /
    • 1998
  • This paper describes a depth extraction algorithm in the stereo endoscopic images using adaptive window. First, The relation between the 3D coordinates in the world and the 2D coordinates in the image plane is estimated using camera calibration. Next, stereo matching is performed to find the conjugate pairs in the left and right images. To improve the precision of the matching result, adaptive window which can be varied on the shape as well as on the size according to the area characteristics is used. Finally, the result from the stereo matching and that of camera modeling are combined to extract the real depth information.

  • PDF

Geo-referenced 영상 획득을 위한 휴대용 멀티센서 시스템 구축 및 정확도 평가 (Development of a Portable Multi-sensor System for Geo-referenced Images and its Accuracy Evaluation)

  • 이지훈;최경아;이임평
    • 한국측량학회지
    • /
    • 제28권6호
    • /
    • pp.637-643
    • /
    • 2010
  • 본 연구에서는 비디오카메라와 GPS/MEMS IMU, UMPC를 결합하여 영상과 위치/자세 데이터를 획득하는 휴대용 멀티센서 시스템을 구축하였다. 구축된 시스템을 통해 획득된 데이터를 이용하여 지상기준점을 이용하지 않고 광속조정법 기반의 영상 geo-referencing을 수행하고 정확도 검증을 통해 시스템의 효용성을 평가하였다. 정확도 검증 결과, 지상점의 상대좌표 정확도는 RMSE가수 cm내외로 상당히 정확함을 확인할 수 있었다. 구축된 시스템은 대상 객체의 3차원 모델과 상대좌표를 획득하는데 있어서 충분히 활용 가능하다고 판단된다. 향후에는 시스템 및 카메라의 엄밀한 보정을 통해 절대좌표의 정확도를 개선할 예정이다.

애니메이션을 위한 통계적 모델에 기반을 둔 3D 얼굴모델링 (3D Face Modeling based on Statistical Model for Animation)

  • 오두식;김재민;조성원;정선태
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국지능시스템학회 2008년도 춘계학술대회 학술발표회 논문집
    • /
    • pp.435-438
    • /
    • 2008
  • 본 논문에서는 애니메이션을 위해서 얼굴의 특징표현(Action Units)의 조합하는 방법으로 얼굴 모델링을 하기 위한 3D대응점(3D dense correspondence)을 찾는 방법을 제시한다. AUs는 표정, 감정, 발음을 나타내는 얼굴의 특징표현으로 통계적 방법인 PCA (Principle Component Analysis)를 이용하여 만들 수 있다. 이를 위해서는 우선 3D 모델상의 대응점을 찾는 것이 필수이다. 2D에서 얼굴의 주요 특징 점은 다양한 알고리즘을 이용하여 찾을 수 있지만 그것만으로 3D상의 얼굴 모델을 표현하기에는 적합하지 않다. 본 논문에서는 3D 얼굴 모델의 대응점을 찾기 위해 원기둥 좌표계 (Cylinderical Coordinates System)을 이용하여 3D 모델을 2D로 투사(Projection)시켜서 만든 2D 이미지간의 워핑(Warping) 을 통한 대응점을 찾아 역으로 3D 모델간의 대응점을 찾는다. 이것은 3D 모델 자체를 변환하는 것보다 적은 연산량으로 계산할 수 있고 본래 형상의 변형이 없다는 장점을 가지고 있다.

  • PDF

PSCAD/EMTDC를 이용한 태양광발전(PV) 모델링에 관한 연구 (The PV System Modeling Based on the PSCAD/EMTDC)

  • 전진택;노대석;김찬혁;왕용필
    • 한국융합학회논문지
    • /
    • 제2권3호
    • /
    • pp.15-23
    • /
    • 2011
  • 본 논문에서는 태양광발전의 3상 인버터의 동작특성을 해석하기 위하여, d-q좌표변환을 통하여 상태방정식을 유도하고, 출력제어를 위한 PI제어기를 갖은 전류제어 알고리즘과 인버터 설계에 대한 Sinusoidal PWM방식의 이론적 알고리즘 제시하였다. 이를 바탕으로 배전계통의 상용소프트웨어인 PSCAD/EMTDC를 이용하여 태양광발전의 모델링을 수행하였다. 그리고 시뮬레이션 결과와 이론적인 수치해석과의 비교, 분석을 통하여 본 연구에서 제시한 모델링의 유효성을 확인하였다.

Stereo Vision System Using Relative Stereo Disparity with Subpixel Resolution

  • Kim, Chi-Yen;Ahn, Cheol-Ki;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.407-407
    • /
    • 2000
  • For acquisition of 3-Dimensional information in real space, stereo vision system is suitable. In the stereo system, 3D real world position is derived from translation of coordinates between cameras and world. Thus, to use stereo vision, it is needed to construct a precise system which provides kinematically precise translation between camera and world coordinate, in spite of intricacy and hardness. So much cost and time should be spent to build the system. In this paper, facilely to solve previous problem, a method which can easily obtain 3D informations using reference objects and RSD(Relative Stereo Disparity) is proposed. Instead of direct computation of position with translation of coordinates, only relative stereo disparity in stereo pair of image is used to find the reference depth of objects, and real 3D position is computed with initial condition of reference objects. In computation, subpixel resolution is involved to find the display for accuracy. To find the RSD, corresponding points are calculated in subpixel resolution. So the result in experiemnt will be shown that subpixel resolution is more accurate than 1 pixel resolution.

  • PDF

비디오 시스템과 영상매칭에 의한 운동물체의 거동측정 (Measurements of the Trajectories of Moving Objects with Video System and Image Matching)

  • 이창경;조우석
    • 한국측량학회지
    • /
    • 제20권3호
    • /
    • pp.331-341
    • /
    • 2002
  • 평면 이미지로부터 3차원 정보를 구하기 위해서는 스테레오 이미지가 필요하고, 움직이는 물체의 거동을 3차원적으로 측정하기 위해서는 스테레오 이미지의 정확한 동기가 필수적이다. 또한, 연속적인 거동측정을 위해서는 동시 촬영한 연속 스테레오 이미지가 필요하고, 위치추적의 자동화를 위해서는 영상 매칭이 그 해결책이다. 본 연구에서는 한 대의 비디오 카메라로 움직이는 물체의 연속 스테레오 이미지를 촬영하여, 영상 매칭에 의해 동일 대상물 및 동일 측점의 중심위치를 결정하고, DLT에 의해 3차원 위치를 해석하는 방법을 제시하였다.

Use of spherical coordinates to evaluate three-dimensional facial changes after orthognathic surgery

  • Yoon, Suk-Ja;Wang, Rui-Feng;Ryu, Sun-Youl;Hwang, Hyeon-Shik;Kang, Byung-Cheol;Lee, Jae-Seo;Palomo, Juan M.
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose: This study aimed to assess the three-dimensional (3D) facial changes after orthognathic surgery by evaluating the spherical coordinates of facial lines using 3D computed tomography (CT). Materials and Methods: A 19-year-old girl was diagnosed with class III malocclusion and facial asymmetry. Orthognathic surgery was performed after orthodontic treatment. Facial CT scans were taken before and after orthognathic surgery. The patient had a menton deviation of 12.72 mm before surgery and 0.83 mm after surgery. The spherical coordinates of four bilateral facial lines (ramal height, ramal lateral, ramal posterior and mandibular body) were estimated from CT scans before and after surgery on the deviated and opposite side. Results: The spherical coordinates of all facial lines changed after orthognathic surgery. Moreover, the bilateral differences of all facial lines changed after surgery, and no bilateral differences were zero. Conclusion: The spherical coordinate system was useful to compare differences between the presurgical and postsurgical changes to facial lines.

3차원 기선벡터망 조정기법에 의한 국가기본점의 성과산정(KTRF94) (Adjustment Computation of the National Fundamental Stations Using 3-D Baseline Vectors(KTRF94))

  • 이영진
    • 한국측량학회지
    • /
    • 제16권1호
    • /
    • pp.85-94
    • /
    • 1998
  • 국립지리원에서는 정밀측지망측량 사업의 일환으로 국가기본망의 구축을 위한 사업에 착수하였으며, 1996년도에는 전국 31점 규모의 GPS망을 관측한바 있다. 이 망은 변장 40 km-120 km(평균 67.4 km) 인 220개의 기선으로서 구성되었다. 본 연구에서는 3차원 기선벡터로 조합된 3차원망을 최소제곱법에 의해 조정하고 산정된 한국측지 기준좌표계94(KTRF94)성과를 제시하였다. VLBI관측점과의 편심관측에 의해 결정된 경위도원점의 ITRF94 좌표를 고정점으로 사용하였으며 조정정확도는 수평위치 1 cm, 높이 3 cm 인 것으로 분석되었다. 아울러 WGS84좌표와 KGS95좌표와의 차이에 대해서도 분석되었다.

  • PDF

Perceived color shift of ceramics according to the change of illuminating light with spectroradiometer

  • Cha, Hyun-Suk;Yu, Bin;Lee, Yong-Keun
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.262-269
    • /
    • 2013
  • PURPOSE. Perceived color of ceramics changes by the spectral power distribution of ambient light. This study aimed to quantify the amount of shifts in color and color coordinates of clinically simulated seven all-ceramics due to the switch of three ambient light sources using a human vision simulating spectroradiometer. MATERIALS AND METHODS. CIE color coordinates, such as $L^*$, $a^*$ and $b^*$, of ceramic specimens were measured under three light sources, which simulate the CIE standard illuminant D65 (daylight), A (incandescent lamp), and F9 (fluorescent lamp). Shifts in color and color coordinate by the switch of lights were determined. Influence of the switched light (D65 to A, or D65 to F9), shade of veneer ceramics (A2 or A3), and brand of ceramics on the shifts was analyzed by a three-way ANOVA. RESULTS. Shifts in color and color coordinates were influenced by three factors (P<.05). Color shifts by the switch to A were in the range of 5.9 to 7.7 ${\Delta}E{^*}_{ab}$ units, and those by the switch to F9 were 7.7 to 10.2; all of which were unacceptable (${\Delta}E{^*}_{ab}$ > 5.5). When switched to A, CIE $a^*$ increased (${\Delta}a^*$: 5.6 to 7.6), however, CIE $b^*$ increased (${\Delta}b^*$: 4.9 to 7.8) when switched to F9. CONCLUSION. Clinically simulated ceramics demonstrated clinically unacceptable color shifts according to the switches in ambient lights based on spectroradiometric readings. Therefore, shade matching and compatibility evaluation should be performed considering ambient lighting conditions and should be done under most relevant lighting condition.

폐곡선의 수에 따른 3차원 물체의 좌표 복원 정확도 관계 도출 (A Derivation of the Accuracy Relationship between the Reconstruction of 3D Object Coordinates and the Number of Closed Curves)

  • 이덕우
    • 한국멀티미디어학회논문지
    • /
    • 제20권7호
    • /
    • pp.1004-1013
    • /
    • 2017
  • This paper presents a relationship between the number of curves and geometric parameters of a 3D object. Once the relationship is established, the number of closed curves that can reliably represent 3D object is derived. Inspired by Shannon-Nyquist Sampling Theorem, in this paper, approach for sampling rate (defined as the minimum number of curves) for 3D reconstruction is proposed. The relationship is straightforward, is suitable for application to 3D object overlaid with closed-continuous curves, and can achieve efficient 3D reconstruction system in practice. To substantiate the proposed approach, simulation results are provided and the results show that the number of curves can be decreased without loss of generality of characteristics of a target 3D object.