• Title/Summary/Keyword: 3D 입체영상

Search Result 617, Processing Time 0.024 seconds

The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning (유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석)

  • Cho Jae Ho;Cho Kwang Hwan;Keum Kichang;Han Yongyih;Kim Yong Bae;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.82-93
    • /
    • 2003
  • Purpose : To reduce the Irradiation dose to the lungs and heart in the case of chest wail irradiation using an oppositional electron beam, we used an Individualized custom bolus, which was precisely designed to compensate for the differences In chest wall thickness. The benefits were evaluated by comparing the normal tissue complication probablilties (NTCPS) and dose statistics both with and without boluses. Materials and Methods : Boluses were made, and their effects evaluated in ten patients treated using the reverse hockey-stick technique. The electron beam energy was determined so as to administer 80% of the irradiation prescription dose to the deepest lung-chest wall border, which was usually located at the internal mammary lymph node chain. An individualized custom bolus was prepared to compensate for a chest wall thinner than the prescription depth by meticulously measuring the chest wall thickness at 1 emf intervals on the planning CT Images. A second planning CT was obtained overlying the individuailzed custom bolus for each patient's chest wall. 3-D treatment planning was peformed using ADAC-Pinnacle$^{3}$ for all patients with and without bolus. NTCPS based on 'the Lyman-Kutcher' model were analyzed and the mean, maximum, minimum doses, V$_{50}$ and V$_{95}$ for 4he heari and lungs were computed. Results .The average NTCPS in the ipsliateral lung showed a statistically significant reduction (p<0.01), from 80.2${\pm}$3.43% to 47.7${\pm}$4.61%, with the use of the individualized custom boluses. The mean lung irradiation dose to the ipsilateral iung was also significantly reduced by about 430 cGy, Trom 2757 cGy to 2,327 cGy (p<0.01). The V$_{50}$ and V$_{95}$ in the ipsilateral lung markedly decreased from the averages of 54.5 and 17.4% to 45.3 and 11.0%, respectively. The V$_{50}$ and V$_{95}$ In the heart also decreased from the averages of 16.8 and 6.1% to 9.8% and 2.2%, respectively. The NTCP In the contralateral lung and the heart were 0%, even for the cases with no bolus because of the small effective mean radiation volume values of 4.4 and 7.1%, respectively Conclusion : The use of an Individualized custom bolus in the radiotherapy of postrnastectorny chest wall reduced the NTCP of the ipsilateral lung by about 24.5 to 40.5%, which can improve the complication free cure probability of breast cancer patients.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Modernist painting style in Disney animation (디즈니 애니메이션에 나타난 모더니즘 회화스타일 : 색, 형태, 공간을 중심으로)

  • Moon, Jae-Cheol;Kim, Yu-Mi
    • Cartoon and Animation Studies
    • /
    • s.33
    • /
    • pp.31-53
    • /
    • 2013
  • In the early twentieth century, history of animation began by modern artists, they produced various experimental images with the newly invented film and cameras. Artists in the field of movie, photography, paintings and others manipulated images in motion. But as some animated movies won industrial success and popularity, they became the trend but experimental style of early animation preserved by so-called non-mainstreamers or experimental animators, counteracting commercialism. Disney animation also followed the trend by applying realistic Hollywood film style, the worse critics placed a low value on the animation and it tarnished the image, although it was profitable investment from a business standpoint. To make images realistic, they opened a drawing class that animators developed skills to imitate motions and forms from subjects in real life. Also some techniques and gizmos were used to mimic and simulate three dimensional objects and spaces, multiplane camera and compositing 3D CG images with 2D drawings. Moreover, they brought animation stories from fairly tales or folk tales, and Walt's personal interest in live-action movies, they applied Hollywood-film-like narratives and realistic visual, and harsh criticism ensued. On the surface early disney animations' potential seems to be weakened, but in reality it still exists by simplifying and exaggerating forms and color as modern arts. Disney animation employs concepts of the modernism paintings such as simplified shapes and colors to a character design, when their characters are placed together in a scene, that visual elements cause mental reaction. This modification gives a new internal experience to audiences. As conceptual colors in abstract paintings make images appeared to be flat, coloring characters with no shading make them look flat and comparing to them, background images are also appeared to be flat. On top of that, multi-perspective at background images recalls modernist paintings. This essay goes in details with the animation pioneers' works and how Disney animation developed its techniques to emulate real life and analyses color schemes, forms, and spaces in Disney animation compared with modern artists' works, in that the visual language of Disney animation reminds of impression from abstract paintings in the beginning of the twentieth centuries.

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

Development and Evaluation of the PBL Teaching/Learning Process Plan of 'Housing Culture and Practical Space Use' for Home Economics in Middle School (중학교 가정과 문제 중심 '주생활 문화와 주거 공간 활용' 교수·학습 과정안 개발과 평가)

  • Cho, Jiwon;Cho, Jaesoon
    • Journal of Korean Home Economics Education Association
    • /
    • v.32 no.2
    • /
    • pp.59-76
    • /
    • 2020
  • The purpose of this study was to develop and evaluate the teaching/learning process plan of 'housing culture and practical space use' for home economics in middle school according to the problem based learning(PBL) model. The plan consisting of 4-lessons has been developed and implemented following the steps of ADDIE model. Various activity materials (4 scenarios, 6 individual activity sheets, 10 reading texts, and 5 working resources) and visual materials (4 sets of ppt and 4 moving pictures) as well as questionnaire were developed for the 4-session lessons. The plans were implemented to a single class of 21 junior students at H middle school in rural area, Kyeongnam, from 1st to 12th of April, 2019. Students highly enjoyed and were satisfied with the whole 4-lessons in aspects such as understanding of the contents, adequacy of materials and activities, and usefulness in one's own daily life. Additionally, they have more actively participated in the lessons than usual and even interested in learning more of such lessons. Students also reported that they highly accomplished the goal of each lesson as well as overall objectives. They showed interest in the major part of PBL lesson such as scenario and group activities. And they engaged themselves in drawing the share housing space plan with '5D planner' web program which they described as the best part of the lessons. The teaching/learning process plan developed in this study may be used as a theme of maker education, which is emerging these days. It can be concluded that the PBL teaching/learning process plans for 'housing values and practical space use' would contribute to improving students' attitude on living with others and ability to manage one's individual life.

The Kinematic Analysis of Jumeok Jireugi in Taekwondo of Security Martial Arts (경호무도의 태권도 주먹 지르기 동작 운동학적 분석)

  • Lee, See-Hwan;Yang, Young-Mo
    • Korean Security Journal
    • /
    • no.31
    • /
    • pp.187-207
    • /
    • 2012
  • The purpose of this study was to analyze the punching movement at the horseback riding stance, one of the basic movements in Taekwondo, with 3D images and further the kinetic variables such as time, velocity, angle, angular velocity, and angular acceleration according to the types. It also aimed to examine the characteristics of each type and suggest instructional methods for the right punching movement. For those purposes, three members from the College Taekwondo Poomse Demonstration Squad were put to the test. The research findings led to the following conclusions: 1. Performance Time of the Punching Movement : In Section 1, Type 1 and 2 recorded $0.24{\pm}0.07s$ and $0.42{\pm}0.08s$, respectively, for the punching movement at the horseback riding stance. While Type 1 took less performance time in the punching movement, Type 2 took less time for take back according to each section's percentage in the total performance time. 2. Variables of Linear Velocity and Linear Acceleration : Each type recorded different linear velocity for each aspect, but the highest linear velocity represented the moment of impact for each type. Type 2 recorded the highest linear velocity in Aspect 4, which was the moment of impact. 3. Variable of Joint Angle : There were no big outer differences in the joint angle during the punching movement between Type 1 in the aspect of impact and Type 2, but the individuals assumed dynamic positions in the punching movement of Type 2 with more diverse changes to the joint angle. 4. Variables of Angular Velocity and Angular Acceleration During the punching movement of Type 1, the Aspect 3 in the moment of impact recorded angular velocity of $0.79{\pm}0.02deg/s$, $0.91{\pm}0.04deg/s$, and $5.24{\pm}0.09deg/s$ at the pelvis, shoulder, and wrist respectively. During the punching movement of Type 2, the Aspect 3 in the moment of impact recorded angular velocity of $1.32{\pm}0.03deg/s$, $0.21{\pm}0.03deg/s$, and $4.98{\pm}0.08deg/$ at the shoulder, wrist, and pelvis, respectively. In the Aspect 3 in the moment of impact in Type 2, the angular acceleration at the right wrist joint was $176.24{\pm}1.11deg/s^2$, which was bigger than that in the moment of impact in Type 1.

  • PDF

A Study on the morphologic characteristics of each constitution's trunk (체간부의 사상체질별 형태학적 특징에 관한 연구)

  • Hong, Suck-chull;Lee, Su-kyung;Lee, Eui-joo;Han, Gi-hwan;Chou, Yong-jin;Choi, Chang-seok;Koh, Byung-hee;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.101-142
    • /
    • 1998
  • 1. Objects The base of classification of Sasang Constitution was the different congenital formation of organs such as lungs, spleen, liver, kidneys, and it was expanded from the viscera region of lungs, spleen, liver, kidneys to the body shape of trunk. The researched about body shape of Sasang Constitution have had points of issues which derived by measurement with hands. But this study was measured the characteristics of body shape putting in importance of anatomical position with the computerized 3-Dimension scanner, which minimized the errors of measurement, and it was abled the cubic measurement such as volume, area of cross section as well as round length. 2. Materials & Method The examinee was healthy male 40 persons and female 20 persons from 20's to 40's, who was diagnosed by the specialist of Sasang Constitutional Medicine. The body shape was measured round length, area of cross section, and volume of 31 anatomical points and the 25 hypothesis with the Rapid 3D Color Scanner Model 3030 RGB/PS. And the characteristics of each constitution's body shape was derived. 3. Results & Concousion In female, Taeumin had the largest trunk and Soeumin had the smallest trunk compared to other constitution, but Soyangin had only the smallest neck. Soeumin has the smallest round length of nipple and the $CV_{12}$, and Soyangin has the smallest breadth of ASIS. Soyangin had the smallest volume from thyroid bone to the highest points of armpits and from sternum to nipple. Taeumin had the largest volume from sternum to the $CV_{12}$ and from sternum to xiphoid process. In male, Taeumin had the largest trunk and Soeumin had the smallest trunk from the level of thyroid bone to ASIS. Soyangin has the longest distance and Soeumin has the shortest distance from nipple to the lowest of breast. Taeumin had the largest volume of trunk and Soeumin had the smallest volume of trunk. In the ration of four-Cho, Taeumin had the longest distance from the highest points of armpits to nipple and Soyangin had the shortest distance of that. Soyangin had the smallest ratio of the height of upper middle cho. Soeumin had the smallest ratio from the $CV_{12}$ to navel among trunk. In the correlation among the four Cho, Taeumin had the negative correlation between the Upper-Cho and the Lower-Middle-Cho significantly.

  • PDF